메뉴 건너뛰기




Volumn 46, Issue 5, 2011, Pages 566-573

Is oral temperature an accurate measurement of deep body temperature? A systematic review

Author keywords

Core temperature; Exertional heat stroke; Hyperthermia

Indexed keywords

BODY TEMPERATURE; DIMENSIONAL MEASUREMENT ACCURACY; FEVER; HEAT STROKE; HUMAN; METHODOLOGY; MOUTH; RECTUM; REVIEW; THERMOMETRY;

EID: 81855191562     PISSN: 10626050     EISSN: None     Source Type: Journal    
DOI: 10.4085/1062-6050-46.5.566     Document Type: Review
Times cited : (57)

References (27)
  • 1
    • 0033763404 scopus 로고    scopus 로고
    • Accuracy of digital tympanic, oral, axillary, and rectal thermometers compared with standard rectal mercury thermometers
    • Jensen BN, Jensen FS, Madsen SN, Lossl K. Accuracy of digital tympanic, oral, axillary, and rectal thermometers compared with standard rectal mercury thermometers. Eur J Surg. 2000;166(11):848-851.
    • (2000) Eur J Surg. , vol.166 , Issue.11 , pp. 848-851
    • Jensen, B.N.1    Jensen, F.S.2    Madsen, S.N.3    Lossl, K.4
  • 3
    • 0026720474 scopus 로고
    • The effect of ambient temperature extremes on tympanic and oral temperatures
    • Doyle F, Zehner WJ, Terndrup TE. The effect of ambient temperature extremes on tympanic and oral temperatures. Am J Emerg Med. 1992;10(4):285-289.
    • (1992) Am J Emerg Med. , vol.10 , Issue.4 , pp. 285-289
    • Doyle, F.1    Zehner, W.J.2    Terndrup, T.E.3
  • 5
    • 0036657598 scopus 로고    scopus 로고
    • National Athletic Trainers' Association position statement: Exertional heat illnesses
    • Binkley HM, Beckett J, Casa DJ, Kleiner DM, Plummer PE. National Athletic Trainers' Association position statement: exertional heat illnesses. J Athl Train. 2002;37(3):329-343.
    • (2002) J Athl Train. , vol.37 , Issue.3 , pp. 329-343
    • Binkley, H.M.1    Beckett, J.2    Casa, D.J.3    Kleiner, D.M.4    Plummer, P.E.5
  • 6
    • 75849161501 scopus 로고    scopus 로고
    • Current knowledge, attitudes, and practices of certified athletic trainers regarding recognition and treatment of exertional heat stroke
    • Mazerolle SM, Scruggs IC, Casa DJ, et al. Current knowledge, attitudes, and practices of certified athletic trainers regarding recognition and treatment of exertional heat stroke. J Athl Train. 2010;45(2):170-180.
    • (2010) J Athl Train. , vol.45 , Issue.2 , pp. 170-180
    • Mazerolle, S.M.1    Scruggs, I.C.2    Casa, D.J.3
  • 7
    • 35148883727 scopus 로고    scopus 로고
    • Athletic trainers' knowledge and behavior regarding the prevention, recognition and treatment of exertional heat stroke at the high school level [abstract]
    • Dombek PM, Casa DJ, Yeargin SW, et al. Athletic trainers' knowledge and behavior regarding the prevention, recognition and treatment of exertional heat stroke at the high school level [abstract]. J Athl Train. 2006;41(2 suppl):S-47.
    • (2006) J Athl Train. , vol.41 , Issue.2 SUPPL.
    • Dombek, P.M.1    Casa, D.J.2    Yeargin, S.W.3
  • 8
    • 0024983753 scopus 로고
    • Oral temperature measurement using Craftemp
    • Steen T. [Oral temperature measurement using Craftemp.] Nord Med. 1990;105(10):266-267.
    • (1990) Nord Med. , vol.105 , Issue.10 , pp. 266-267
    • Steen, T.1
  • 9
    • 0026420802 scopus 로고
    • Only rectal temperature measurements are suitable for routine temperature measurement
    • Jensen BN, Jeppesen LJ, Mortensen BB. [Only rectal temperature measurements are suitable for routine temperature measurement.] Ugeskr Laeger. 1991;153(50):3346-3549.
    • (1991) Ugeskr Laeger. , vol.153 , Issue.50 , pp. 3346-3549
    • Jensen, B.N.1    Jeppesen, L.J.2    Mortensen, B.B.3
  • 10
    • 0024969051 scopus 로고
    • Can measurement of oral or axillary temperature replace rectal temperature measurements?
    • Gote H, Rasmussen S, Norskov B, Schilichting P. [Can measurement of oral or axillary temperature replace rectal temperature measurements?] Ugeskr Laeger. 1989;151(33):2085-2087.
    • (1989) Ugeskr Laeger. , vol.151 , Issue.33 , pp. 2085-2087
    • Gote, H.1    Rasmussen, S.2    Norskov, B.3    Schilichting, P.4
  • 11
    • 0026420798 scopus 로고
    • Oral versus rectal measurement of body temperature
    • Nielsen TG, Bakholdt VT. [Oral versus rectal measurement of body temperature.] Ugeskr Laeger. 1991;153(50):3541-3543.
    • (1991) Ugeskr Laeger. , vol.153 , Issue.50 , pp. 3541-3543
    • Nielsen, T.G.1    Bakholdt, V.T.2
  • 12
    • 0026420784 scopus 로고
    • Oral measurement of body temperature: Clinical use of an electronic thermometer (Craftemp)
    • Hansen UM. [Oral measurement of body temperature: clinical use of an electronic thermometer (Craftemp).] Ugeskr Laeger. 1991;153(50):3535-3537.
    • (1991) Ugeskr Laeger. , vol.153 , Issue.50 , pp. 3535-3537
    • Hansen, U.M.1
  • 13
    • 0030425191 scopus 로고    scopus 로고
    • Mesures comparatives des temperatures buccales et rectales chez 224 malades hospitalises
    • Couilliet D, Meyer P, Grosshans E. [Comparative measurements of oral and rectal temperatures in 224 hospitalized patients.] Ann Med Interne (Paris). 1996;147(8):536-538. (Pubitemid 27165473)
    • (1996) Annales de Medecine Interne , vol.147 , Issue.8 , pp. 536-538
    • Couilliet, D.1    Meyer, P.2    Grosshans, E.3
  • 15
    • 66349132197 scopus 로고    scopus 로고
    • Validity and reliability of devices that assess body temperature during indoor exercise in the heat
    • Ganio MS, Brown CM, Casa DJ, et al. Validity and reliability of devices that assess body temperature during indoor exercise in the heat. J Athl Train. 2009;44(2):124-135.
    • (2009) J Athl Train. , vol.44 , Issue.2 , pp. 124-135
    • Ganio, M.S.1    Brown, C.M.2    Casa, D.J.3
  • 16
    • 84872153813 scopus 로고    scopus 로고
    • PEDro Scale, Accessed February 8, 2009
    • PEDro Scale. Physiotherapy Evidence Database. http://www.pedro.fhs. usyd.edu.au/. Accessed February 8, 2009.
    • Physiotherapy Evidence Database
  • 17
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • PII S0140673686908378
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1(8476):307-310. (Pubitemid 16134762)
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 18
    • 0024978528 scopus 로고
    • Should electronic mouth thermometers be used in routine everyday hospital practice? Usefulness of mouth thermometers
    • Jensen BN, Andreasen H, Kjaergaard B, Glavind K. [Should electronic mouth thermometers be used in routine everyday hospital practice? Usefulness of mouth thermometers.] Ugeskr Laeger. 1989;151(39):2514-2516.
    • (1989) Ugeskr Laeger. , vol.151 , Issue.39 , pp. 2514-2516
    • Jensen, B.N.1    Andreasen, H.2    Kjaergaard, B.3    Glavind, K.4
  • 19
    • 0015583896 scopus 로고
    • Elevation in set point for body temperature regulation after prolonged exercise
    • Haight JSJ, Keatinge WR. Elevation in set point for body temperature regulation after prolonged exercise. J Physiol. 1973;229(1):77-85.
    • (1973) J Physiol. , vol.229 , Issue.1 , pp. 77-85
    • Haight, J.S.J.1    Keatinge, W.R.2
  • 20
    • 0016691985 scopus 로고
    • Effect of head skin temperature on tympanic and oral temperature in man
    • McCaffrey TV, McCook RD, Wurster RD. Effect of head skin temperature on tympanic and oral temperature in man. J Appl Physiol. 1975;39(1): 114-118.
    • (1975) J Appl Physiol. , vol.39 , Issue.1 , pp. 114-118
    • McCaffrey, T.V.1    McCook, R.D.2    Wurster, R.D.3
  • 22
    • 0020662959 scopus 로고
    • An evaluation of body temperature measurement
    • Isley AH, Rutten AJ, Runciman WB. An evaluation of body temperature measurement. Anaesth Intens Care. 1983;11(1):31-39. (Pubitemid 13139198)
    • (1983) Anaesthesia and Intensive Care , vol.11 , Issue.1 , pp. 31-39
    • Ilsley, A.H.1    Runciman, W.B.2
  • 23
    • 0033848554 scopus 로고    scopus 로고
    • Core temperature measurement during supine exercise: Esophageal, rectal, and intestinal temperatures
    • Lee SM, Williams WJ, Fortney Schneider SM. Core temperature measurement during supine exercise: esophageal, rectal, and intestinal temperatures. Aviat Space Environ Med. 2000;71(9):939-945.
    • (2000) Aviat Space Environ Med. , vol.71 , Issue.9 , pp. 939-945
    • Lee, S.M.1    Williams, W.J.2    Fortney, S.S.M.3
  • 24
    • 3042615721 scopus 로고    scopus 로고
    • Comparison of axillary temperature with rectal or oral temperature and determination of optimum placement time in children
    • Chaturvedi D, Vilhekar KY, Chaturvedi P, Bharambe MS. Comparison of axillary temperature with rectal or oral temperature and determination of optimum placement time in children. Indian Pediatr. 2004;41(6):600-603. (Pubitemid 38843580)
    • (2004) Indian Pediatrics , vol.41 , Issue.6 , pp. 600-603
    • Chaturvedi, D.1    Vilhekar, K.Y.2    Chaturvedi, P.3    Bharambe, M.S.4
  • 26
    • 81855211932 scopus 로고    scopus 로고
    • Evidence-based practice and the recognition and treatment of exertional heat stroke, Part I: A perspective from the educator
    • Mazerolle SM, Ruiz RC, Casa DJ, et al. Evidence-based practice and the recognition and treatment of exertional heat stroke, part I: a perspective from the educator. J Athl Train. 2011;46(5):523-532
    • (2011) J Athl Train. , vol.46 , Issue.5 , pp. 523-532
    • Mazerolle, S.M.1    Ruiz, R.C.2    Casa, D.J.3
  • 27
    • 81855185782 scopus 로고    scopus 로고
    • Evidence-based medicine and the recognition and treatment of exertional heat stroke, Part Ii: A perspective from the clinical athletic trainer
    • Mazerolle SM, Pinkus DP, Casa DJ, et al. Evidence-based medicine and the recognition and treatment of exertional heat stroke, part II: a perspective from the clinical athletic trainer. J Athl Train. 2011;46(5):533-542
    • (2011) J Athl Train. , vol.46 , Issue.5 , pp. 533-542
    • Mazerolle, S.M.1    Pinkus, D.P.2    Casa, D.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.