1
-
-
35148827727
-
Validity of devices that assess body temperature during outdoor exercise in the heat
-
Casa DJ, Becker SM, Ganio MS, et al. Validity of devices that assess body temperature during outdoor exercise in the heat. J Athl Train. 2007;42(3):333-342. (Pubitemid 47535676)
-
(2007)
Journal of Athletic Training
, vol.42
, Issue.3
, pp. 333-342
-
-
Casa, D.J.1
Becker, S.M.2
Ganio, M.S.3
Brown, C.M.4
Yeargin, S.W.5
Roti, M.W.6
Siegler, J.7
Blowers, J.A.8
Glaviano, N.R.9
Huggins, R.A.10
Armstrong, L.E.11
Maresh, C.M.12
-
2
-
-
0036657598
-
National Athletic Trainers' Association position statement: Exertional heat illnesses
-
Binkley HM, Beckett J, Casa DJ, Kleiner DM, Plummer PE. National Athletic Trainers' Association position statement: Exertional heat illnesses. J Athl Train. 2002;37(3):329-343.
-
(2002)
J Athl Train
, vol.37
, Issue.3
, pp. 329-343
-
-
Binkley, H.M.1
Beckett, J.2
Casa, D.J.3
Kleiner, D.M.4
Plummer, P.E.5
-
3
-
-
35148883727
-
Athletic trainers' knowledge and behavior regarding the prevention, recognition and treatment of exertional heat stroke at the high school level
-
abstract
-
Dombek PM, Casa D, Yeargin SW, et al. Athletic trainers' knowledge and behavior regarding the prevention, recognition and treatment of exertional heat stroke at the high school level [abstract]. J Athl Train. 2006;41(2 suppl):S-47.
-
(2006)
J Athl Train
, vol.41
, Issue.2 SUPPL.
-
-
Dombek, P.M.1
Casa, D.2
Yeargin, S.W.3
-
4
-
-
0034265163
-
A comparative study on accuracy of liquid crystal forehead, digital electronic axillary, infrared tympanic with glass-mercury rectal thermometer in infants and young children
-
Kongpanichkul A, Bunjongpak S. A comparative study on accuracy of liquid crystal forehead, digital electronic axillary, infrared tympanic with glass-mercury rectal thermometer in infants and young children. J Med Assoc Thai. 2000;83(9):1068-1076.
-
(2000)
J Med Assoc Thai
, vol.83
, Issue.9
, pp. 1068-1076
-
-
Kongpanichkul, A.1
Bunjongpak, S.2
-
5
-
-
3042830642
-
When body temperature changes, does rectal temperature lag?
-
Greenes DS, Fleisher GR. When body temperature changes, does rectal temperature lag? J Pediatr. 2004;144(6):824-826.
-
(2004)
J Pediatr
, vol.144
, Issue.6
, pp. 824-826
-
-
Greenes, D.S.1
Fleisher, G.R.2
-
7
-
-
0025035774
-
Does forehead liquid crystal temperature accurately reflect "core" temperature?
-
Allen GC, Horrow JC, Rosenberg H. Does forehead liquid crystal temperature accurately reflect "core" temperature? Can J Anaesth. 1990;37(6):659-662.
-
(1990)
Can J Anaesth
, vol.37
, Issue.6
, pp. 659-662
-
-
Allen, G.C.1
Horrow, J.C.2
Rosenberg, H.3
-
8
-
-
0033763404
-
Accuracy of digital tympanic, oral, axillary, and rectal thermometers compared with standard rectal mercury thermometers
-
Jensen BN, Jensen FS, Madsen SN, Lossl K. Accuracy of digital tympanic, oral, axillary, and rectal thermometers compared with standard rectal mercury thermometers. Eur J Surg. 2000;166(11):848-851.
-
(2000)
Eur J Surg
, vol.166
, Issue.11
, pp. 848-851
-
-
Jensen, B.N.1
Jensen, F.S.2
Madsen, S.N.3
Lossl, K.4
-
9
-
-
0033848554
-
Core temperature measurement during supine exercise: Esophageal, rectal, and intestinal temperatures
-
Lee SM, Williams WJ, Fortney Schneider SM. Core temperature measurement during supine exercise: esophageal, rectal, and intestinal temperatures. Aviat Space Environ Med. 2000;71(9):939-945.
-
(2000)
Aviat Space Environ Med
, vol.71
, Issue.9
, pp. 939-945
-
-
Lee, S.M.1
Williams, W.J.2
Fortney Schneider, S.M.3
-
10
-
-
0037348764
-
Temperature measurement in intensive care patients: Comparison of urinary bladder, oesophageal, rectal, axillary, and inguinal methods versus pulmonary artery core method
-
Lefrant JY, Muller L, de La Coussaye JE, et al. Temperature measurement in intensive care patients: Comparison of urinary bladder, oesophageal, rectal, axillary, and inguinal methods versus pulmonary artery core method. Intensive Care Med. 2003;29(3):414-418. (Pubitemid 36379443)
-
(2003)
Intensive Care Medicine
, vol.29
, Issue.3
, pp. 414-418
-
-
Lefrant, J.-Y.1
Muller, L.2
Emmanuel Coussaye, J.3
Benbabaali, M.4
Lebris, C.5
Zeitoun, N.6
Mari, C.7
Saissi, G.8
Ripart, J.9
Eledjam, J.-J.10
-
11
-
-
3042615721
-
Comparison of axillary temperature with rectal or oral temperature and determination of optimum placement time in children
-
Chaturvedi D, Vilhekar KY, Chaturvedi P, Bharambe MS. Comparison of axillary temperature with rectal or oral temperature and determination of optimum placement time in children. Indian Pediatr. 2004;41(6):600-603. (Pubitemid 38843580)
-
(2004)
Indian Pediatrics
, vol.41
, Issue.6
, pp. 600-603
-
-
Chaturvedi, D.1
Vilhekar, K.Y.2
Chaturvedi, P.3
Bharambe, M.S.4
-
12
-
-
33745181975
-
Exertional heat stroke in competitive athletes
-
Casa DJ, Armstrong LE, Ganio MS, Yeargin SW. Exertional heat stroke in competitive athletes. Curr Sports Med Rep. 2005;4(6):309-317.
-
(2005)
Curr Sports Med Rep
, vol.4
, Issue.6
, pp. 309-317
-
-
Casa, D.J.1
Armstrong, L.E.2
Ganio, M.S.3
Yeargin, S.W.4
-
13
-
-
0027934685
-
Assessing core temperature in collapsed athletes: What's the best method?
-
Roberts WO. Assessing core temperature in collapsed athletes: what's the best method? Physician Sportsmed. 1994;22(8):49-55.
-
(1994)
Physician Sportsmed
, vol.22
, Issue.8
, pp. 49-55
-
-
Roberts, W.O.1
-
14
-
-
0036448190
-
Core temperature measurement: Methods and current insights
-
Moran DS, Mendal L. Core temperature measurement: methods and current insights. Sports Med. 2002;32(14):879-885. (Pubitemid 35440608)
-
(2002)
Sports Medicine
, vol.32
, Issue.14
, pp. 879-885
-
-
Moran, D.S.1
Mendal, L.2
-
15
-
-
0010569403
-
Considerations for the medical staff: Preventing, identifying, and treating exertional heat illnesses
-
Armstrong LE, ed. Champaign, IL: Human Kinetics
-
Casa DJ, Roberts WO. Considerations for the medical staff: Preventing, identifying, and treating exertional heat illnesses. In: Armstrong LE, ed. Exertional Heat Illnesses. Champaign, IL: Human Kinetics; 2003:169-196.
-
(2003)
Exertional Heat Illnesses
, pp. 169-196
-
-
Casa, D.J.1
Roberts, W.O.2
-
16
-
-
0020287616
-
The effect of head cooling on deep body temperature and thermal comfort in man
-
Brown GA, Williams GM. The effect of head cooling on deep body temperature and thermal comfort in man. Aviat Space Environ Med. 1982;53(6):583-586. (Pubitemid 12014602)
-
(1982)
Aviation Space and Environmental Medicine
, vol.53
, Issue.6
, pp. 583-586
-
-
Brown, G.A.1
Williams, G.M.2
-
17
-
-
0020639077
-
Effect of cold exposure on various sites of core temperature measurements
-
Livingstone SD, Grayson J, Frim J, Allen CL, Limmer RE. Effect of cold exposure on various sites of core temperature measurements. J Appl Physiol. 1983;54(4):1025-1031.
-
(1983)
J Appl Physiol
, vol.54
, Issue.4
, pp. 1025-1031
-
-
Livingstone, S.D.1
Grayson, J.2
Frim, J.3
Allen, C.L.4
Limmer, R.E.5
-
18
-
-
0025872699
-
The impact of moderate ambient temperature variance on the relationship between oral, rectal, and tympanic membrane temperatures
-
Zehner WJ, Terndrup TE. The impact of moderate ambient temperature variance on the relationship between oral, rectal, and tympanic membrane temperatures. Clin Pediatr (Phila). 1991;30(4 suppl):61-72.
-
(1991)
Clin Pediatr (Phila)
, vol.30
, Issue.4 SUPPL.
, pp. 61-72
-
-
Zehner, W.J.1
Terndrup, T.E.2
-
19
-
-
0002756941
-
Tympanic temperature should not be used to assess exercise induced hyperthermia
-
Deschamps A, Levy RD, Cosio MG, Marliss EB, Magder S. Tympanic temperature should not be used to assess exercise induced hyperthermia. Clin J Sport Med. 1992;2(1):27-32.
-
(1992)
Clin J Sport Med
, vol.2
, Issue.1
, pp. 27-32
-
-
Deschamps, A.1
Levy, R.D.2
Cosio, M.G.3
Marliss, E.B.4
Magder, S.5
-
20
-
-
0018333422
-
Natural selective cooling of the human brain: Evidence of its occurrence and magnitude
-
Cabanac M, Caputa M. Natural selective cooling of the human brain: evidence of its occurrence and magnitude. J Physiol. 1979;286(1):255-264. (Pubitemid 9085482)
-
(1979)
Journal of Physiology
, vol.VOL. 286
, pp. 255-264
-
-
Cabanac, M.1
Caputa, M.2
-
21
-
-
0023746479
-
Independence of brain and tympanic temperatures in an unanesthetized human
-
Shiraki K, Sagawa S, Tajima F, Yokota A, Hashimoto M, Brengelmann GL. Independence of brain and tympanic temperatures in an unanesthetized human. J Appl Physiol. 1988;65(1):482-486. (Pubitemid 18192885)
-
(1988)
Journal of Applied Physiology
, vol.65
, Issue.1
, pp. 482-486
-
-
Shiraki, K.1
Sagawa, S.2
Tajima, F.3
Yokota, A.4
Hashimoto, M.5
Brengelmann, G.L.6
-
22
-
-
0001560453
-
Validation of a temperature telemetry system during moderate and strenuous exercise
-
DOI 10.1016/0306-4565(93)90004-D
-
Kolka MA, Quigley MD, Blanchard LA, Toyota DA, Stephenson LA. Validation of a temperature telemetry system during moderate and strenuous exercise. J Therm Biol. 1993;18(4):203-210. (Pubitemid 223039246)
-
(1993)
Journal of Thermal Biology
, vol.18
, Issue.4
, pp. 203-210
-
-
Kolka, M.A.1
Quigley, M.D.2
Blanchard, L.A.3
Toyota, D.A.4
Stephenson, L.A.5
-
24
-
-
0019226183
-
Measurement of cardiorespiratory fitness and body composition in the clinical setting
-
Pollock ML, Schmidt DH, Jackson AS. Measurement of cardiorespiratory fitness and body composition in the clinical setting. Compr Ther. 1980;6(9):12-27. (Pubitemid 11191936)
-
(1980)
Comprehensive Therapy
, vol.6
, Issue.9
, pp. 12-27
-
-
Pollack, M.L.1
Schmidt, D.H.2
Jackson, A.S.3
-
26
-
-
0022654816
-
Perceptual and physiological responses during exercise in cool and cold water
-
Toner MM, Drolet LL, Pandolf KB. Perceptual and physiological responses during exercise in cool and cold water. Percept Mot Skills. 1986;62(1):211-220. (Pubitemid 16136111)
-
(1986)
Perceptual and Motor Skills
, vol.62
, Issue.1
, pp. 211-220
-
-
Toner, M.M.1
Drolet, L.L.2
Pandwolf, K.B.3
-
27
-
-
0031790628
-
Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine
-
DOI 10.2165/00007256-199826040-00002
-
Atkinson G, Nevill AM. Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine. Sports Med. 1998;26(4):217-238. (Pubitemid 28505200)
-
(1998)
Sports Medicine
, vol.26
, Issue.4
, pp. 217-238
-
-
Atkinson, G.1
Nevill, A.M.2
-
28
-
-
33750718153
-
The validity and reliability of intestinal temperature during intermittent running
-
DOI 10.1249/01.mss.0000233800.69776.ef
-
Gant N, Atkinson G, Williams C. The validity and reliability of intestinal temperature during intermittent running. Med Sci Sports Exerc. 2006;38(11):1926-1931. (Pubitemid 44707796)
-
(2006)
Medicine and Science in Sports and Exercise
, vol.38
, Issue.11
, pp. 1926-1931
-
-
Gant, N.1
Atkinson, G.2
Williams, C.3
-
29
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
PII S0140673686908378
-
Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1(8476): 307-310. (Pubitemid 16134762)
-
(1986)
Lancet
, vol.1
, Issue.8476
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
30
-
-
0028926373
-
Calculating correlation coefficients with repeated observations, part I: Correlation within subjects
-
Bland JM, Altman DG. Calculating correlation coefficients with repeated observations, part I: correlation within subjects. BMJ. 1995;310(6977):446.
-
(1995)
BMJ
, vol.310
, Issue.6977
, pp. 446
-
-
Bland, J.M.1
Altman, D.G.2
-
31
-
-
0020607930
-
Oral temperature as an index of core temperature during heat transients
-
Mairiaux P, Sagot JC, Candas V. Oral temperature as an index of core temperature during heat transients. Eur J Appl Physiol Occup Physiol. 1983;50(3):331-341.
-
(1983)
Eur J Appl Physiol Occup Physiol
, vol.50
, Issue.3
, pp. 331-341
-
-
Mairiaux, P.1
Sagot, J.C.2
Candas, V.3
-
33
-
-
0032884749
-
Measuring agreement in method comparison studies
-
DOI 10.1191/096228099673819272
-
Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res. 1999;8(2):135-160. (Pubitemid 29425900)
-
(1999)
Statistical Methods in Medical Research
, vol.8
, Issue.2
, pp. 135-160
-
-
Bland, J.M.1
Altman, D.G.2
-
34
-
-
33746806902
-
Reliability of an infrared forehead skin thermometer for core temperature measurements
-
DOI 10.1080/03091900600711381, PII W81566L21355P888
-
Kistemaker JA, Den Hartog EA, Daanen HA. Reliability of an infrared forehead skin thermometer for core temperature measurements. J Med Eng Technol. 2006;30(4):252-261. (Pubitemid 44177380)
-
(2006)
Journal of Medical Engineering and Technology
, vol.30
, Issue.4
, pp. 252-261
-
-
Kistemaker, J.1
Den Hartog, E.2
Daanen, H.3
-
35
-
-
0031452987
-
Use of an ingestible telemetry sensor to measure core temperature under chemical protective clothing
-
DOI 10.1016/S0306-4565(97)00032-6, PII S0306456597000326
-
Kolka MA, Levine L, Stephenson LA. Use of an ingestible telemetry system to measure core temperature under chemical protective clothing. J Therm Biol. 1997;22(4-5):343-349. (Pubitemid 28034877)
-
(1997)
Journal of Thermal Biology
, vol.22
, Issue.4-5
, pp. 343-349
-
-
Kolka, M.A.1
Levine, L.2
Stephenson, L.A.3
-
36
-
-
33646172633
-
Core temperature and percentage of dehydration in professional football linemen and backs during preseason practices
-
Godek SF, Bartolozzi AR, Burkholder R, Sugarman E, Dorshimer G. Core temperature and percentage of dehydration in professional football linemen and backs during preseason practices. J Athl Train. 2006;41(1):8-17.
-
(2006)
J Athl Train
, vol.41
, Issue.1
, pp. 8-17
-
-
Godek, S.F.1
Bartolozzi, A.R.2
Burkholder, R.3
Sugarman, E.4
Dorshimer, G.5
-
37
-
-
33644833531
-
Thermoregulatory observations in soccer match play: Professional and recreational level applications using an intestinal pill system to measure core temperature
-
DOI 10.1136/bjsm.2005.021980
-
Edwards AM, Clark NA. Thermoregulatory observations in soccer match play: professional and recreational level applications using an intestinal pill system to measure core temperature. Br J Sports Med. 2006;40(2):133-138. (Pubitemid 43362457)
-
(2006)
British Journal of Sports Medicine
, vol.40
, Issue.2
, pp. 133-138
-
-
Edwards, A.M.1
Clark, N.A.2
-
38
-
-
34347338772
-
Temporal thermometry fails to track body core temperature during heat stress
-
DOI 10.1249/mss.0b013e318050ca3e, PII 0000576820070700000001
-
Low DA, Vu A, Brown M, et al. Temporal thermometry fails to track body core temperature during heat stress. Med Sci Sports Exerc. 2007;39(7):1029-1035. (Pubitemid 47014129)
-
(2007)
Medicine and Science in Sports and Exercise
, vol.39
, Issue.7
, pp. 1029-1035
-
-
Low, D.A.1
Vu, A.2
Brown, M.3
Davis, S.L.4
Keller, D.M.5
Levine, B.D.6
Crandall, C.G.7
-
39
-
-
34147201241
-
The ingestible telemetric body core temperature sensor: A review of validity and exercise applications
-
DOI 10.1136/bjsm.2006.026344
-
Byrne C, Lim CL. The ingestible telemetric body core temperature sensor: a review of validity and exercise applications. Br J Sports Med. 2007;41(3):126-133. (Pubitemid 46579892)
-
(2007)
British Journal of Sports Medicine
, vol.41
, Issue.3
, pp. 126-133
-
-
Byrne, C.1
Lim, C.L.2
-
40
-
-
0029877451
-
Reexamination of tympanic membrane temperature as a core temperature
-
Sato KT, Kane NL, Soos G, Gisolfi CV, Kondo N, Sato K. Reexamination of tympanic membrane temperature as a core temperature. J Appl Physiol. 1996;80(4):1233-1239. (Pubitemid 26118526)
-
(1996)
Journal of Applied Physiology
, vol.80
, Issue.4
, pp. 1233-1239
-
-
Sato, K.T.1
Kane, N.L.2
Soos, G.3
Gisolfi, C.V.4
Kondo, N.5
Sato, K.6
-
41
-
-
0010600007
-
Interpretation of aural temperatures during exercise, hyperthermia, and cooling therapy
-
Armstrong LE, Maresh CM, Crago AE, Adams R, Roberts WO. Interpretation of aural temperatures during exercise, hyperthermia, and cooling therapy. Med Exerc Nutr Health. 1994;3(1): 9-16.
-
(1994)
Med Exerc Nutr Health
, vol.3
, Issue.1
, pp. 9-16
-
-
Armstrong, L.E.1
Maresh, C.M.2
Crago, A.E.3
Adams, R.4
Roberts, W.O.5
-
43
-
-
0029796389
-
Agreement between rectal and tympanic membrane temperatures in marathon runners
-
Roth RN, Verdile VP, Grollman LJ, Stone DA. Agreement between rectal and tympanic membrane temperatures in marathon runners. Ann Emerg Med. 1996;28(4):414-417. (Pubitemid 26327639)
-
(1996)
Annals of Emergency Medicine
, vol.28
, Issue.4
, pp. 414-417
-
-
Roth, R.N.1
Verdile, V.P.2
Grollman, L.J.3
Stone, D.A.4
-
44
-
-
0030249857
-
Comparison of esophageal, tympanic, and forehead skin temperatures in adult patients
-
DOI 10.1016/0952-8180(96)00103-1
-
Patel N, Smith CE, Pinchak AC, Hagen JF. Comparison of esophageal, tympanic, and forehead skin temperatures in adult patients. J Clin Anesth. 1996;8(6):462-468. (Pubitemid 26282658)
-
(1996)
Journal of Clinical Anesthesia
, vol.8
, Issue.6
, pp. 462-468
-
-
Patel, N.1
Smith, C.E.2
Pinchak, A.C.3
Hagen, J.F.4
|