-
1
-
-
0031681194
-
4 based on a chemically modified screen-printed NADH sensor
-
DOI 10.1016/S0003-2670(98)00368-7, PII S0003267098003687
-
Abass A. K., Hart J. P., Cowell D. C., Chappell A., Development of an amperometric assay for NH4+ based on a chemically modified screen-printed NADH sensor Analytica Chimica Acta 1998 373 1 1 8 (Pubitemid 28428896)
-
(1998)
Analytica Chimica Acta
, vol.373
, Issue.1
, pp. 1-8
-
-
Abass, A.K.1
Hart, J.P.2
Cowell, D.C.3
Chappell, A.4
-
2
-
-
1342264309
-
Solid-state ammonia sensor based on Berthelot's reaction
-
Lau K. T., Edwards S., Diamond D., Solid-state ammonia sensor based on Berthelot's reaction Sensors and Actuators B 2004 98 1 12 17
-
(2004)
Sensors and Actuators B
, vol.98
, Issue.1
, pp. 12-17
-
-
Lau, K.T.1
Edwards, S.2
Diamond, D.3
-
3
-
-
20344394451
-
Continuous colorimetric determination of trace ammonium in seawater with a long-path liquid waveguide capillary cell
-
DOI 10.1016/j.marchem.2004.12.001, PII S0304420304003135
-
Li P. Q., Zhang J. Z., Millero F. J., Hansell D. A., Continuous colorimetric determination of trace ammonium in seawater with a long-path liquid waveguide capillary cell Marine Chemistry 2005 96 1-2 73 85 (Pubitemid 40778409)
-
(2005)
Marine Chemistry
, vol.96
, Issue.1-2
, pp. 73-85
-
-
Li, Q.P.1
Zhang, J.-Z.2
Millero, F.J.3
Hansell, D.A.4
-
4
-
-
51649112599
-
Fluorescence sensors for trace monitoring of dissolved ammonia
-
Waich K., Mayr T., Klimant I., Fluorescence sensors for trace monitoring of dissolved ammonia Talanta 2008 77 1 66 72
-
(2008)
Talanta
, vol.77
, Issue.1
, pp. 66-72
-
-
Waich, K.1
Mayr, T.2
Klimant, I.3
-
5
-
-
42949163400
-
Characterization of ammonium ion - Sensitive membranes in solution with electrochemical impedance spectroscopy
-
DOI 10.1016/j.msec.2007.10.081, PII S0928493107002378
-
Zougar S., Morakchi K., Zazoua K., Saad S., Kherrat R., Renault N. J., Characterization of ammonium ion-sensitive membranes in solution with electrochemical impedance spectroscopy Materials Science and Engineering C 2008 28 5-6 1020 1023 (Pubitemid 351608290)
-
(2008)
Materials Science and Engineering C
, vol.28
, Issue.5-6
, pp. 1020-1023
-
-
Zougar, S.1
Morakchi, K.2
Zazoua, A.3
Saad, S.4
Kherrat, R.5
Jaffrezic-Renault, N.6
-
6
-
-
34047240004
-
Ammonia toxicity and tolerance in the brain of the African sharptooth catfish, Clarias gariepinus
-
DOI 10.1016/j.aquatox.2007.02.015, PII S0166445X07000793
-
Wee N. L. J., Tng Y. Y. M., Cheng H. T., Lee S. M. L., Chew S. F., Ip Y. K., Ammonia toxicity and tolerance in the brain of the African sharptooth catfish, Clarias gariepinus Aquatic Toxicology 2007 82 3 204 213 (Pubitemid 46533862)
-
(2007)
Aquatic Toxicology
, vol.82
, Issue.3
, pp. 204-213
-
-
Wee, N.L.J.1
Tng, Y.Y.M.2
Cheng, H.T.3
Lee, S.M.L.4
Chew, S.F.5
Ip, Y.K.6
-
7
-
-
41549104498
-
Purge-and-trap ion chromatography for the determination of trace ammonium ion in high-salinity water samples
-
Wang P. Y., Wu J. Y., Chen H. J., Lin T. Y., Wu C. H., Purge-and-trap ion chromatography for the determination of trace ammonium ion in high-salinity water samples Journal of Chromatography A 2008 1188 2 69 74
-
(2008)
Journal of Chromatography A
, vol.1188
, Issue.2
, pp. 69-74
-
-
Wang, P.Y.1
Wu, J.Y.2
Chen, H.J.3
Lin, T.Y.4
Wu, C.H.5
-
8
-
-
43449109158
-
Green synthesis of silver nanoparticles for ammonia sensing
-
Dubas S. T., Pimpan V., Green synthesis of silver nanoparticles for ammonia sensing Talanta 2008 76 1 29 33
-
(2008)
Talanta
, vol.76
, Issue.1
, pp. 29-33
-
-
Dubas, S.T.1
Pimpan, V.2
-
9
-
-
18544374276
-
Amperometric determination of ammonium with bienzyme/poly(carbamoyl) sulfonate hydrogel-based biosensor
-
DOI 10.1016/j.snb.2004.11.028, PII S0925400504007798
-
Kwan R. C. H., Hon P. Y. T., Renneberg R., Amperometric determination of ammonium with bienzyme/poly(carbamoyl) sulfonate hydrogel-based biosensor Sensors and Actuators B 2005 107 2 616 622 (Pubitemid 40655001)
-
(2005)
Sensors and Actuators, B: Chemical
, vol.107
, Issue.2
, pp. 616-622
-
-
Kwan, R.C.H.1
Hon, P.Y.T.2
Renneberg, R.3
-
10
-
-
33947545110
-
Capillary electrophoretic determination of ammonia using headspace single-drop microextraction
-
Pranaityte B., Jermak S., Naujalis E., Padarauskas A., Capillary electrophoretic determination of ammonia using headspace single-drop microextraction Microchemical Journal 2007 86 1 48 52
-
(2007)
Microchemical Journal
, vol.86
, Issue.1
, pp. 48-52
-
-
Pranaityte, B.1
Jermak, S.2
Naujalis, E.3
Padarauskas, A.4
-
11
-
-
0035127596
-
Ammonium in nervous tissue: Transport across cell membranes, fluxes from neurons to glial cells, and role in signalling
-
DOI 10.1016/S0301-0082(00)00043-5, PII S0301008200000435
-
Marcaggi P., Coles J. A., Ammonium in nervous tissue: transport across cell membranes, fluxes from neurons to glial cells, and role is signalling Progress in Neurobiology 2001 64 2 157 183 (Pubitemid 32195411)
-
(2001)
Progress in Neurobiology
, vol.64
, Issue.2
, pp. 157-183
-
-
Marcaggi, P.1
Coles, J.A.2
-
12
-
-
0030199404
-
Flow injection gas-diffusion amperometric determination of trace amounts of ammonium ions with a cupric hexacyanoferrate
-
DOI 10.1016/0039-9140(96)01858-9
-
Liu R., Sun B., Liu D., Sun A., Flow injection gas-diffusion amperometric determination of trace amounts of ammonium ions with a cupric hexacyanoferrate Talanta 1996 43 7 1049 1054 (Pubitemid 26351832)
-
(1996)
Talanta
, vol.43
, Issue.7
, pp. 1049-1054
-
-
Liu, R.1
Sun, B.2
Liu, D.3
Sun, A.4
-
13
-
-
0033365076
-
ISFET microsensors for the detection of pollutants in liquid media
-
DOI 10.1016/S0925-4005(99)00213-0
-
Renault N. J., Senillou A., Martelet C., Wan K., Chovelon J. M., ISFET microsensors for the detection of pollutants in liquid media Sensors and Actuators B 1999 59 2 154 164 (Pubitemid 30523274)
-
(1999)
Sensors and Actuators, B: Chemical
, vol.59
, Issue.2
, pp. 154-164
-
-
Jaffrezic-Renault, N.1
Senillou, A.2
Martelet, C.3
Wan, K.4
Chovelon, J.M.5
-
14
-
-
0030058210
-
Study of the performance of an optochemical sensor for ammonia
-
DOI 10.1016/0003-2670(95)00540-4
-
Trinkel M., Trettnak W., Reininger F., Benes R., O'Leary P., Wolfbeis O. S., Study of the performance of an optochemical sensor for ammonia Analytica Chimica Acta 1996 320 2-3 235 243 (Pubitemid 26070103)
-
(1996)
Analytica Chimica Acta
, vol.320
, Issue.2-3
, pp. 235-243
-
-
Trinkel, M.1
Trettnak, W.2
Reininger, F.3
Benes, R.4
O'Leary, P.5
Wolfbeis, O.S.6
-
15
-
-
0032825450
-
Flow spectrophotometric determination of ammonium ion
-
DOI 10.1016/S0003-2670(99)00384-0, PII S0003267099003840
-
Icardo M. C., Torro I. G., Zamora L. L., Calatayud J. M., Flow spectrophotometric determination of ammonium ion Analytica Chimica Acta 1999 398 2-3 311 318 (Pubitemid 29472486)
-
(1999)
Analytica Chimica Acta
, vol.398
, Issue.2-3
, pp. 311-318
-
-
Icardo, M.C.1
Torro, I.G.2
Zamora, L.L.3
Calatayud, J.M.4
-
16
-
-
0037162988
-
Solvent extraction-Spectrophotometric determination of trace amounts of ammonium, barium and potassium in a mixture by dicyclohexyl-18-crown-6 and orange II
-
Parham H., Mobarakzadeh M., Solvent extraction-Spectrophotometric determination of trace amounts of ammonium, barium and potassium in a mixture by dicyclohexyl-18-crown-6 and orange II Talanta 2002 58 2 281 287
-
(2002)
Talanta
, vol.58
, Issue.2
, pp. 281-287
-
-
Parham, H.1
Mobarakzadeh, M.2
-
17
-
-
25844476797
-
2O mixed electrolyte system
-
DOI 10.1016/j.jelechem.2005.07.012, PII S0022072805003761
-
Deyhimi F., Choobar B. G., Potentiometric determination of activity coefficients for NH 4 Cl in the ternary NH 4 Cl/LiCl/H 2 O mixed electrolyte system Journal of Electroanalytical Chemistry 2005 584 2 141 146 (Pubitemid 41394188)
-
(2005)
Journal of Electroanalytical Chemistry
, vol.584
, Issue.2
, pp. 141-146
-
-
Deyhimi, F.1
Ghalami-Choobar, B.2
-
18
-
-
0035910665
-
Novel solid-state ammonium ion potentiometric sensor based on zirconium titanium phosphate ion exchanger
-
Hassan S. S. M., Marei S. A., Badr I. H., Arida H. A., Novel solid-state ammonium ion potentiometric sensor based on zirconium titanium phosphate ion exchanger Analytica Chimica Acta 2001 427 1 21 28
-
(2001)
Analytica Chimica Acta
, vol.427
, Issue.1
, pp. 21-28
-
-
Hassan, S.S.M.1
Marei, S.A.2
Badr, I.H.3
Arida, H.A.4
-
19
-
-
0035098194
-
A flow injection-fluorometric method for the determination of ammonium in fresh and saline waters with a view to in situ analyses
-
DOI 10.1016/S0043-1354(00)00429-2, PII S0043135400004292
-
Aminot A., Kerouel R., Birot D., A flow injection-fluorometric method for the determination of ammonium in fresh and saline waters with a view to in situ analyses Water Research 2001 35 7 1777 1785 (Pubitemid 32201487)
-
(2001)
Water Research
, vol.35
, Issue.7
, pp. 1777-1785
-
-
Aminot, A.1
Kerouel, R.2
Birot, D.3
-
20
-
-
0029138062
-
Ammonium-oxidation at low pH by a chemolithotrophic bacterium belonging to the genus Nitrosospira
-
Boer W. D., Gunnewiek P. A. K., Laanbroek H. J., Ammonium-oxidation at low pH by a chemolithotrophic bacterium belonging to the genus Nitrosospira Soil Biology Biochemistry 1995 27 2 127 132
-
(1995)
Soil Biology Biochemistry
, vol.27
, Issue.2
, pp. 127-132
-
-
Boer, W.D.1
Gunnewiek, P.A.K.2
Laanbroek, H.J.3
-
21
-
-
0030659840
-
Kinetics of ammonium removal with suspended and immobilized nitrifying bacteria in different reactor systems
-
DOI 10.1016/S0045-6535(97)00341-X, PII S004565359700341X
-
Strotmann U. J., Windecker G., Kinetics of ammonium removal with suspended and immobilized nitrifying bacteria in different reactor systems Chemosphere 1997 35 12 2939 2952 (Pubitemid 27507354)
-
(1997)
Chemosphere
, vol.35
, Issue.12
, pp. 2939-2952
-
-
Strotmann, U.J.1
Windecker, G.2
-
22
-
-
33645234721
-
Nitrite production by Nitrosomonas europaea and Nitrosospira sp. AV in soils at different solution concentrations of ammonium
-
Taylor A. E., Bottomley P. J., Nitrite production by Nitrosomonas europaea and Nitrosospira sp. AV in soils at different solution concentrations of ammonium Soil Biology Biochemistry 2006 38 4 828 836
-
(2006)
Soil Biology Biochemistry
, vol.38
, Issue.4
, pp. 828-836
-
-
Taylor, A.E.1
Bottomley, P.J.2
-
23
-
-
34548864408
-
A multi-commuted flow injection system with a multi-channel propulsion unit placed before detection: Spectrophotometric determination of ammonium
-
DOI 10.1016/j.aca.2007.01.019, PII S0003267007000773
-
Oliveira S. M., Lopes T. I. M. S., Toth I. V., Rangel A. O. S. S., A multi-commuted flow injection system with a multi-channel propulsion unit placed before detection: spectrophotometric determination of ammonium Analytica Chimica Acta 2007 600 1-2 29 34 (Pubitemid 47445419)
-
(2007)
Analytica Chimica Acta
, vol.600
, Issue.SPEC. ISS.
, pp. 29-34
-
-
Oliveira, S.M.1
Lopes, T.I.M.S.2
Toth, I.V.3
Rangel, A.O.S.S.4
-
24
-
-
22344451435
-
Fluorometric determination of ammonium ion by ion chromatography using postcolumn derivatization with o-phthaldialdehyde
-
Kuo C. T., Wang P. Y., Wu C. H., Fluorometric determination of ammonium ion by ion chromatography using postcolumn derivatization with o-phthaldialdehyde Journal of Chromatography A 2005 1085 1 91 97
-
(2005)
Journal of Chromatography A
, vol.1085
, Issue.1
, pp. 91-97
-
-
Kuo, C.T.1
Wang, P.Y.2
Wu, C.H.3
-
25
-
-
15744398969
-
Improved detection limit for ammonium/ammonia achieved by Berthelot's reaction by use of solid-phase extraction coupled to diffuse reflectance spectroscopy
-
Martinez Y. M., Hernandez R. H., Falco P. C., Improved detection limit for ammonium/ammonia achieved by Berthelot's reaction by use of solid-phase extraction coupled to diffuse reflectance spectroscopy Analytica Chimica Acta 2005 534 2 327 334
-
(2005)
Analytica Chimica Acta
, vol.534
, Issue.2
, pp. 327-334
-
-
Martinez, Y.M.1
Hernandez, R.H.2
Falco, P.C.3
-
26
-
-
0030071879
-
FET-based sensors with robust photosensitive polymer membranes for detection of ammonium ions and urea
-
DOI 10.1016/0956-5663(96)88412-0
-
Kazanskaya N., Kukhtin A., Manenkova M., Reshetilov N., Yarysheva L., Arzhakova O., Volynskii A., Bakeyev N., FET-based sensors with robust photosensitive polymer membranes for detection of ammonium ions and urea Biosensors and Bioelectronics 1996 11 3 253 261 (Pubitemid 26042804)
-
(1996)
Biosensors and Bioelectronics
, vol.11
, Issue.3
, pp. 253-261
-
-
Kazanskaya, N.1
Kukhtin, A.2
Manenkova, M.3
Reshetilov, N.4
Yarysheva, L.5
Arzhakova, O.6
Volynskii, A.7
Bakeyev, N.8
-
27
-
-
0032173130
-
A miniaturized ammonium sensor based on the integration of both ammonium and reference FETs in a single chip
-
DOI 10.1016/S0928-4931(98)00037-X, PII S092849319800037X
-
Senillou A., Renault N. J., Martelet C., Griffe F., A miniaturized ammonium sensor based on the integration of both ammonium and reference FETs in a single chip Materials Science and Engineering C 1998 6 1 59 63 (Pubitemid 29122944)
-
(1998)
Materials Science and Engineering C
, vol.6
, Issue.1
, pp. 59-63
-
-
Senillou, A.1
Jaffrezic-Renault, N.2
Martelet, C.3
Griffe, F.4
-
28
-
-
61449095823
-
A novel reagentless biosensor based on self-assembled HRP and Nile Blue premixed with poly(styrenesulfonate) architectures
-
Yang S., Chen Z., Li Y., Jiang X., Lin X., A novel reagentless biosensor based on self-assembled HRP and Nile Blue premixed with poly(styrenesulfonate) architectures Canadian Journal of Analytical Sciences and Spectroscopy 2006 51 3 174 179
-
(2006)
Canadian Journal of Analytical Sciences and Spectroscopy
, vol.51
, Issue.3
, pp. 174-179
-
-
Yang, S.1
Chen, Z.2
Li, Y.3
Jiang, X.4
Lin, X.5
-
29
-
-
0042433507
-
Purification and characterization of alanine dehydrogenase from a marine bacterium, Vibrio proteolyticus
-
DOI 10.1016/S1381-1177(03)00101-2
-
Kato S. I., Ohshima T., Galkin A., Kulakova L., Yoshimura T., Esaki N., Purification and characterization of alanine dehydrogenase from a marine bacterium, Vibrio proteolyticus Journal of Molecular Catalysis B 2003 23 26 373 378 (Pubitemid 37011213)
-
(2003)
Journal of Molecular Catalysis B: Enzymatic
, vol.23
, Issue.2-6
, pp. 373-378
-
-
Kato, S.-I.1
Ohshima, T.2
Galkin, A.3
Kulakova, L.4
Yoshimura, T.5
Esaki, N.6
-
30
-
-
0031768514
-
L-alanine fermentation by an alanine racemase-deficient mutant of the DL-alanine hyperproducing bacterium Arthrobacter oxydans HAP-1
-
DOI 10.1016/S0922-338X(99)89009-6
-
Hashimoto S. I., Katsumata R., L-alanine fermentation by an alanine racemase-deficient mutant of the DL-alanine hyperproducing bacterium Arthrobacter oxydans HAP-1 Journal of Fermentation and Bioengineering 1998 86 4 385 390 (Pubitemid 28530015)
-
(1998)
Journal of Fermentation and Bioengineering
, vol.86
, Issue.4
, pp. 385-390
-
-
Hashimoto, S.-I.1
Katsumata, R.2
-
31
-
-
4143144860
-
A novel archaeal alanine dehydrogenase homologous to ornithine cyclodeaminase and μ-crystallin
-
DOI 10.1128/JB.186.22.7680-7689.2004
-
Schroder I., Vadas A., Johnson E., Lim S., Monbouquette H. G., A novel archeal alanine dehydrogenase homologous to ornithine cyclodeaminase and -crystalin The Journal of Bacteriology 2004 186 22 7680 7689 (Pubitemid 39463734)
-
(2004)
Journal of Bacteriology
, vol.186
, Issue.22
, pp. 7680-7689
-
-
Schroder, I.1
Vadas, A.2
Johnson, E.3
Lim, S.4
Monbouquette, H.G.5
-
32
-
-
0030032074
-
Amperometric ammonium ion and urea determination with enzyme-based probes
-
Bertocchi P., Compagnone D., Amperometric ammonium ion and urea determination with enzyme-based probes Biosensors and Bioelectronics 1996 11 1-2 1 10
-
(1996)
Biosensors and Bioelectronics
, vol.11
, Issue.12
, pp. 1-10
-
-
Bertocchi, P.1
Compagnone, D.2
-
33
-
-
0018702816
-
Purification and properties of alanine dehydrogenase from Bacillus sphaericus
-
DOI 10.1111/j.1432-1033.1979.tb02030.x
-
Ohashima T., Soda K., Purification and properties of alanine dehydrogenase from Bacillus sphaericus European Journal of Biochemistry 1979 100 1 29 39 (Pubitemid 10237736)
-
(1979)
European Journal of Biochemistry
, vol.100
, Issue.1
, pp. 29-39
-
-
Ohashima, T.1
Soda, K.2
-
34
-
-
0037048720
-
Influence of pH and ionic strength on heat-induced formation and rheological properties of soy protein gels in relation to denaturation and their protein compositions
-
DOI 10.1021/jf020061b
-
Renkema J. M. S., Gruppen H., Vliet T. V., Influence of pH and ionic strength on heat-induced formation and rheological properties of soy protein gels in relation to denaturation and their protein compositions Journal of Agricultural and Food Chemistry 2002 50 21 6064 6071 (Pubitemid 35155336)
-
(2002)
Journal of Agricultural and Food Chemistry
, vol.50
, Issue.21
, pp. 6064-6071
-
-
Renkema, J.M.S.1
Gruppen, H.2
Van Vliet, T.3
-
35
-
-
0000912120
-
Purification and partial characterization of alanine dehydrogenase from Streptomyces aureofaciens
-
Curova I. V., Cura A. V., Volc J. R., Zzil J. R. N., Flieger M., Rova G. B., Behal V., Purification and partial characterization of alanine dehydrogenase from Streptomyces aureofaciens Archives of Microbiology 2004 150 5 438 440
-
(2004)
Archives of Microbiology
, vol.150
, Issue.5
, pp. 438-440
-
-
Curova, I.V.1
Cura, A.V.2
Volc, J.R.3
Zzil, J.R.N.4
Flieger, M.5
Rova, G.B.6
Behal, V.7
-
36
-
-
4544380472
-
Amperometric biosensor for rapid determination of alanine
-
DOI 10.1016/j.aca.2004.07.019, PII S000326700400858X
-
Kwan R. C. H., Hon P. Y. T., Renneberg R., Amperometric biosensor for rapid determination of alanine Analytica Chimica Acta 2004 523 1 81 88 (Pubitemid 39214936)
-
(2004)
Analytica Chimica Acta
, vol.523
, Issue.1
, pp. 81-88
-
-
Kwan, R.C.H.1
Hon, P.Y.T.2
Renneberg, R.3
-
37
-
-
0023441129
-
Immobilization of glucose oxidase in poly(2-hydroxyethyl methacrylate) membranes
-
Arica Y., Hasirci V. N., Immobilization of glucose oxidase in poly(2-hydroxyethyl methacrylate) membranes Biomaterials 1987 8 6 489 495
-
(1987)
Biomaterials
, vol.8
, Issue.6
, pp. 489-495
-
-
Arica, Y.1
Hasirci, V.N.2
-
38
-
-
33244497817
-
A chemical sensor for trace V(V) ion determination based on fatty hydroxamic acid immobilized in polymethylmethacrylate
-
DOI 10.1016/j.snb.2005.06.007, PII S0925400505005216
-
Isha A., Yusof N. A., Musa A., Suhendra D., Yunus W. M. Z. W., Zainal Z., A chemical sensor for trace V(V) ion determination based on fatty hydroxamic acid immobilized in polymethylmethacrylate Sensors and Actuators B 2006 114 1 344 349 (Pubitemid 43276198)
-
(2006)
Sensors and Actuators, B: Chemical
, vol.114
, Issue.1
, pp. 344-349
-
-
Isha, A.1
Yusof, N.A.2
Ahmad, M.3
Suhendra, D.4
Yunus, W.M.Z.W.5
Zainal, Z.6
-
39
-
-
0345352783
-
Covalent immobilisation of invertase onto a reactive film composed of 2-hydroxyethyl methacrylate and glycidyl methacrylate: Properties and application in a continuous flow system
-
DOI 10.1016/S1369-703X(02)00170-5, PII S1369703X02001705
-
Bayramoglu G., Akgol S., Bulut A., Denizli A., Arica M. Y., Covalent immobilisation of invertase onto a reactive film composed of 2-hydroxyethyl methacrylate and glycidyl methacrylate: properties and application in a continuous flow system Biochemical Engineering Journal 2003 14 2 117 126 (Pubitemid 36457281)
-
(2003)
Biochemical Engineering Journal
, vol.14
, Issue.2
, pp. 117-126
-
-
Bayramoglu, G.1
Akgol, S.2
Bulut, A.3
Denizli, A.4
Arica, M.Y.5
-
41
-
-
0004142037
-
-
7th New York, NY, USA McGraw-Hill
-
Chang R., Chemistry 2002 7th New York, NY, USA McGraw-Hill
-
(2002)
Chemistry
-
-
Chang, R.1
|