메뉴 건너뛰기




Volumn 66, Issue 6, 2011, Pages 1788-1797

A flexible 32-channel receive array combined with a homogeneous transmit coil for human lung imaging with hyperpolarized 3He at 1.5 T

Author keywords

hyperpolarization; lung; parallel imaging; receive array

Indexed keywords

BIOLOGICAL ORGANS; BIOMEDICAL SIGNAL PROCESSING; MAGNETIC RESONANCE IMAGING; RESPIRATORY SYSTEM;

EID: 81355138902     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.22962     Document Type: Article
Times cited : (19)

References (22)
  • 2
    • 0030982409 scopus 로고    scopus 로고
    • Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
    • Sodickson DK, Manning WJ,. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med 1997; 38: 591-603.
    • (1997) Magn Reson Med , vol.38 , pp. 591-603
    • Sodickson, D.K.1    Manning, W.J.2
  • 5
    • 33646455297 scopus 로고    scopus 로고
    • Advantages of parallel imaging in conjunction with hyperpolarized helium-A new approach to MRI of the lung
    • Lee RF, Johnson G, Grossmann RI, Stoeckel B, Trampel R, McGuiness G,. Advantages of parallel imaging in conjunction with hyperpolarized helium-a new approach to MRI of the lung. Magn Reson Med 2006; 55: 1132-1141.
    • (2006) Magn Reson Med , vol.55 , pp. 1132-1141
    • Lee, R.F.1    Johnson, G.2    Grossmann, R.I.3    Stoeckel, B.4    Trampel, R.5    McGuiness, G.6
  • 6
    • 36849088522 scopus 로고    scopus 로고
    • Sparse MRI: The application of compressed sensing for rapid MR imaging
    • Lustig M, Donoho D, Pauly JM,. Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 2007; 58: 1182-1195.
    • (2007) Magn Reson Med , vol.58 , pp. 1182-1195
    • Lustig, M.1    Donoho, D.2    Pauly, J.M.3
  • 8
    • 32544455772 scopus 로고    scopus 로고
    • Signal-to-noise considerations for parallel imaging with hyperpolarized noble gases
    • Miami Beach
    • Mugler JP III, Brookeman JR,. Signal-to-noise considerations for parallel imaging with hyperpolarized noble gases. In: Proceedings of the 13th Annual Meeting of ISMRM, Miami Beach, 2005. p 485.
    • (2005) Proceedings of the 13th Annual Meeting of ISMRM , pp. 485
    • Mugler III, J.P.1    Brookeman, J.R.2
  • 12
    • 0036201635 scopus 로고    scopus 로고
    • K-space filtering in 2D gradient-echo breath-hold hyperpolarized 3He MRI: Spatial resolution and signal-to-noise ratio
    • Wild JM, Paley MNJ, Viallon M, Schreiber WG, van Beek EJR, Griffiths PD,. k-space filtering in 2D gradient-echo breath-hold hyperpolarized 3He MRI: spatial resolution and signal-to-noise ratio. Magn Reson Med 2002; 47: 687-695.
    • (2002) Magn Reson Med , vol.47 , pp. 687-695
    • Wild, J.M.1    Paley, M.N.J.2    Viallon, M.3    Schreiber, W.G.4    Van Beek, E.J.R.5    Griffiths, P.D.6
  • 16
    • 0000714697 scopus 로고    scopus 로고
    • A novel method to reduce the signal coupling of surface coils for MRI
    • New York
    • Wang J,. A novel method to reduce the signal coupling of surface coils for MRI. In: Proceedings of the 4th Annual Meeting of ISMRM, New York, 1996. p 1434.
    • (1996) Proceedings of the 4th Annual Meeting of ISMRM , pp. 1434
    • Wang, J.1
  • 17
    • 0009603343 scopus 로고    scopus 로고
    • Ladder networks for capacitive decoupling in phased-array coils
    • Glasgow
    • Jevtic J,. Ladder networks for capacitive decoupling in phased-array coils. In: Proceedings of the 9th Annual Meeting of ISMRM, Glasgow, 2001. p 17.
    • (2001) Proceedings of the 9th Annual Meeting of ISMRM , pp. 17
    • Jevtic, J.1
  • 19
    • 81355152489 scopus 로고    scopus 로고
    • Concentrically shielded surface coils-A new method for decoupling phased array elements
    • Seattle
    • Lanz T, Griswold M,. Concentrically shielded surface coils-a new method for decoupling phased array elements. In: Proceedings of the 14th Annual Meeting of ISMRM, Seattle, 2006. p 217.
    • (2006) Proceedings of the 14th Annual Meeting of ISMRM , pp. 217
    • Lanz, T.1    Griswold, M.2
  • 21
    • 27644527486 scopus 로고    scopus 로고
    • Image reconstruction in SNR units: A general method for SNR measurement
    • Kellman P, McVeigh ER,. Image reconstruction in SNR units: a general method for SNR measurement. Magn Reson Med 2005; 54: 1439-1447
    • (2005) Magn Reson Med , vol.54 , pp. 1439-1447
    • Kellman, P.1    McVeigh, E.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.