메뉴 건너뛰기




Volumn 160, Issue 1, 2011, Pages 1450-1457

Preparation and electrochemical characteristics of electrodeposited acetaminophen on ruthenium oxide nanoparticles and its role as a sensor for simultaneous determination of ascorbic acid, dopamine and N-acetyl-l-cysteine

Author keywords

Acetaminophen; Ascorbic acid; Dopamine; N Acetyl l cysteine; Ruthenium oxide nanoparticles

Indexed keywords

ACETAMINOPHEN; ASCORBIC ACIDS; DOPAMINE; N-ACETYL L-CYSTEINE; RUTHENIUM OXIDE NANOPARTICLES;

EID: 81155131774     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2011.10.012     Document Type: Article
Times cited : (35)

References (54)
  • 1
    • 62649152294 scopus 로고    scopus 로고
    • Copper nanoparticles-modified carbon paste transducer as a biosensor for determination of acetylcholine
    • H. Heli, M. Hajjizadeh, A. Jabbari, and A. Moosavi-Movahedi Copper nanoparticles-modified carbon paste transducer as a biosensor for determination of acetylcholine Biosens. Bioelectron. 24 2009 2328 2333
    • (2009) Biosens. Bioelectron. , vol.24 , pp. 2328-2333
    • Heli, H.1    Hajjizadeh, M.2    Jabbari, A.3    Moosavi-Movahedi, A.4
  • 2
    • 77956490319 scopus 로고    scopus 로고
    • Nanoparticle modified electrodes: Surface coverage effects in voltammetry showing the transition from convergent to linear diffusion. The reduction of aqueous chromium (III) at silver nanoparticle modified electrodes
    • Y.G. Zhou, F.W. Campbell, S.R. Belding, and R.G. Compton Nanoparticle modified electrodes: surface coverage effects in voltammetry showing the transition from convergent to linear diffusion. The reduction of aqueous chromium (III) at silver nanoparticle modified electrodes Chem. Phys. Lett. 497 2010 200 204
    • (2010) Chem. Phys. Lett. , vol.497 , pp. 200-204
    • Zhou, Y.G.1    Campbell, F.W.2    Belding, S.R.3    Compton, R.G.4
  • 3
    • 79953285982 scopus 로고    scopus 로고
    • Directed self-assembly of gold nanoparticles on graphene-ionic liquid hybrid for enhancing electrocatalytic activity
    • M.H. Yang, B.G. Choi, H. Park, T.J. Park, W.H. Hong, and S.Y. Lee Directed self-assembly of gold nanoparticles on graphene-ionic liquid hybrid for enhancing electrocatalytic activity Electroanalysis 23 2011 850 857
    • (2011) Electroanalysis , vol.23 , pp. 850-857
    • Yang, M.H.1    Choi, B.G.2    Park, H.3    Park, T.J.4    Hong, W.H.5    Lee, S.Y.6
  • 4
    • 79551572385 scopus 로고    scopus 로고
    • Preparation of Pt-shell-Pd-core nanoparticle with electroless deposition of copper for polymer electrolyte membrane fuel cell
    • I. Choi, S.H. Ahn, J.J. Kim, and O.J. Kwon Preparation of Pt-shell-Pd-core nanoparticle with electroless deposition of copper for polymer electrolyte membrane fuel cell Appl. Catal. B 102 2011 608 613
    • (2011) Appl. Catal. B , vol.102 , pp. 608-613
    • Choi, I.1    Ahn, S.H.2    Kim, J.J.3    Kwon, O.J.4
  • 5
    • 52549109259 scopus 로고    scopus 로고
    • Electro-deposition of platinum nanoparticles on 4-mercaptobenzene- functionalized multi-walled carbon nanotubes
    • J. Shi, X.S. Li, Y.Q. Hu, and Y.X. Hua Electro-deposition of platinum nanoparticles on 4-mercaptobenzene-functionalized multi-walled carbon nanotubes J. Solid State Electrochem. 12 2008 1555 1559
    • (2008) J. Solid State Electrochem. , vol.12 , pp. 1555-1559
    • Shi, J.1    Li, X.S.2    Hu, Y.Q.3    Hua, Y.X.4
  • 6
    • 33745646788 scopus 로고    scopus 로고
    • Electrocatalytic oxidation of formic acid on platinum nanoparticle electrode deposited on the nichrome substrate
    • Z. Wang, and K. Qiu Electrocatalytic oxidation of formic acid on platinum nanoparticle electrode deposited on the nichrome substrate Electrochem. Commun. 8 2006 1075 1081
    • (2006) Electrochem. Commun. , vol.8 , pp. 1075-1081
    • Wang, Z.1    Qiu, K.2
  • 7
    • 18844431828 scopus 로고    scopus 로고
    • Silver nanoparticle assemblies supported on glassy-carbon electrodes for the electro-analytical detection of hydrogen peroxide
    • C. Welch, C. Banks, A. Simm, and R. Compton Silver nanoparticle assemblies supported on glassy-carbon electrodes for the electro-analytical detection of hydrogen peroxide Anal. Bioanal. Chem. 382 2005 12 21
    • (2005) Anal. Bioanal. Chem. , vol.382 , pp. 12-21
    • Welch, C.1    Banks, C.2    Simm, A.3    Compton, R.4
  • 8
    • 78751616763 scopus 로고    scopus 로고
    • Methanol electrooxidation at mesoporous Pt and Pt-Ru electrodes: A comparative study with carbon supported materials
    • G. Garcia, J. Florez-Montano, A. Hernandez-Creus, E. Pastor, and G.A. Planes Methanol electrooxidation at mesoporous Pt and Pt-Ru electrodes: a comparative study with carbon supported materials J. Power Sources 196 2011 2979 2986
    • (2011) J. Power Sources , vol.196 , pp. 2979-2986
    • Garcia, G.1    Florez-Montano, J.2    Hernandez-Creus, A.3    Pastor, E.4    Planes, G.A.5
  • 9
    • 0035665727 scopus 로고    scopus 로고
    • Size control of polymer-stabilized ruthenium nanoparticles by polyol reduction
    • X. Yan, H. Liu, and K.Y. Liew Size control of polymer-stabilized ruthenium nanoparticles by polyol reduction J. Mater. Chem. 11 2001 3387 3391
    • (2001) J. Mater. Chem. , vol.11 , pp. 3387-3391
    • Yan, X.1    Liu, H.2    Liew, K.Y.3
  • 10
    • 77952881740 scopus 로고    scopus 로고
    • Electrochemical sensing of NADH based on Meldola Blue immobilized silver nanoparticle-conducting polymer electrode
    • A. Balamurugan, K.C. Ho, S.M. Chen, and T.Y. Huang Electrochemical sensing of NADH based on Meldola Blue immobilized silver nanoparticle-conducting polymer electrode Colloids Surf. A 362 2010 1 7
    • (2010) Colloids Surf. A , vol.362 , pp. 1-7
    • Balamurugan, A.1    Ho, K.C.2    Chen, S.M.3    Huang, T.Y.4
  • 11
    • 33749633788 scopus 로고
    • Electro-oxidation of CO and methanol on graphite-based platinum electrodes combined with oxide-supported ultrafine gold particles
    • P. Biswas, Y. Nodasaka, M. Enyo, and M. Haruta Electro-oxidation of CO and methanol on graphite-based platinum electrodes combined with oxide-supported ultrafine gold particles J. Electroanal. Chem. 381 1995 167 177
    • (1995) J. Electroanal. Chem. , vol.381 , pp. 167-177
    • Biswas, P.1    Nodasaka, Y.2    Enyo, M.3    Haruta, M.4
  • 12
    • 77952956922 scopus 로고    scopus 로고
    • Electrodeposited nano-scale islands of ruthenium oxide as a bifunctional electrocatalyst for simultaneous catalytic oxidation of hydrazine and hydroxylamine
    • H.R. Zare, S.H. Hashemi, and A. Benvidi Electrodeposited nano-scale islands of ruthenium oxide as a bifunctional electrocatalyst for simultaneous catalytic oxidation of hydrazine and hydroxylamine Anal. Chim. Acta 668 2010 182 187
    • (2010) Anal. Chim. Acta , vol.668 , pp. 182-187
    • Zare, H.R.1    Hashemi, S.H.2    Benvidi, A.3
  • 13
    • 61449157789 scopus 로고    scopus 로고
    • Renewable-surface sol-gel derived carbon ceramic-modified electrode fabricated by a newly synthesized polypyridil and phosphine Ru (II) complex and its application as an amperometric sensor for hydrazine
    • A. Abbaspour, M. Shamsipur, A. Siroueinejad, R. Kia, and P.R. Raithby Renewable-surface sol-gel derived carbon ceramic-modified electrode fabricated by a newly synthesized polypyridil and phosphine Ru (II) complex and its application as an amperometric sensor for hydrazine Electrochim. Acta 54 2009 2916 2923
    • (2009) Electrochim. Acta , vol.54 , pp. 2916-2923
    • Abbaspour, A.1    Shamsipur, M.2    Siroueinejad, A.3    Kia, R.4    Raithby, P.R.5
  • 14
    • 29244449022 scopus 로고    scopus 로고
    • Anodically formed oxide films and oxygen reduction on electrodeposited ruthenium in acid solution
    • M. Metikos-Hukovic, R. Babic, F. Jovic, and Z. Grubac Anodically formed oxide films and oxygen reduction on electrodeposited ruthenium in acid solution Electrochim. Acta 51 2006 1157 1164
    • (2006) Electrochim. Acta , vol.51 , pp. 1157-1164
    • Metikos-Hukovic, M.1    Babic, R.2    Jovic, F.3    Grubac, Z.4
  • 15
    • 77953924015 scopus 로고    scopus 로고
    • Glutathione reductase is inhibited by acetaminophen-glutathione conjugate in vitro
    • T. Roušar, P. Pařík, O. Kučear, M. Bartoš, and Z. Červinková Glutathione reductase is inhibited by acetaminophen-glutathione conjugate in vitro Physiol. Res. 59 2010 225 232
    • (2010) Physiol. Res. , vol.59 , pp. 225-232
    • Roušar, T.1    Pařík, P.2    Kučear, O.3    Bartoš, M.4    Červinková, Z.5
  • 17
    • 29544448331 scopus 로고    scopus 로고
    • Intracellular signaling mechanisms of acetaminophen-induced liver cell death
    • H. Jaeschke, and M.L. Bajt Intracellular signaling mechanisms of acetaminophen-induced liver cell death Toxicol. Sci. 89 2006 31 41
    • (2006) Toxicol. Sci. , vol.89 , pp. 31-41
    • Jaeschke, H.1    Bajt, M.L.2
  • 18
    • 51649099721 scopus 로고    scopus 로고
    • A nutrient mixture prevents acetaminophen hepatic and renal toxicity in ICR mice
    • M.W. Roomi, T. Kalinovsky, V. Ivanov, M. Rath, and A. Niedzwiecki A nutrient mixture prevents acetaminophen hepatic and renal toxicity in ICR mice Hum. Exp. Toxicol. 27 2008 223 230
    • (2008) Hum. Exp. Toxicol. , vol.27 , pp. 223-230
    • Roomi, M.W.1    Kalinovsky, T.2    Ivanov, V.3    Rath, M.4    Niedzwiecki, A.5
  • 19
    • 33845406305 scopus 로고    scopus 로고
    • Silymarin modulates cisplatin-induced oxidative stress and hepatotoxicity in rats
    • H.H. Mansour, H.F. Hafez, and N.M. Fahmy Silymarin modulates cisplatin-induced oxidative stress and hepatotoxicity in rats J. Biochem. Mol. Biol. 39 2006 656 661
    • (2006) J. Biochem. Mol. Biol. , vol.39 , pp. 656-661
    • Mansour, H.H.1    Hafez, H.F.2    Fahmy, N.M.3
  • 20
    • 33846362170 scopus 로고    scopus 로고
    • Voltammetric investigation of the interactions between superoxide ion and some sulfur amino acids
    • G. Feroci, and A. Fini Voltammetric investigation of the interactions between superoxide ion and some sulfur amino acids Inorg. Chim. Acta 360 2007 1023 1031
    • (2007) Inorg. Chim. Acta , vol.360 , pp. 1023-1031
    • Feroci, G.1    Fini, A.2
  • 21
    • 0032823875 scopus 로고    scopus 로고
    • Induction of cyclin-dependent kinase inhibitors and G1 prolongation by the chemopreventive agent N-acetylcysteine
    • M. Liu, N.M. Wikonkal, and D.E. Brash Induction of cyclin-dependent kinase inhibitors and G1 prolongation by the chemopreventive agent N-acetylcysteine Carcinogenesis 20 1999 1869 1872
    • (1999) Carcinogenesis , vol.20 , pp. 1869-1872
    • Liu, M.1    Wikonkal, N.M.2    Brash, D.E.3
  • 22
    • 33747762642 scopus 로고    scopus 로고
    • Protective effect of N-acetyl-l-cysteine on amyloid [beta]-peptide- induced learning and memory deficits in mice
    • A.L. Fu, Z.H. Dong, and M.J. Sun Protective effect of N-acetyl-l-cysteine on amyloid [beta]-peptide-induced learning and memory deficits in mice Brain Res. 1109 2006 201 206
    • (2006) Brain Res. , vol.1109 , pp. 201-206
    • Fu, A.L.1    Dong, Z.H.2    Sun, M.J.3
  • 23
    • 9244257382 scopus 로고    scopus 로고
    • HIV-associated dementia, mitochondrial dysfunction, and oxidative stress
    • V. Valcour, and B. Shiramizu HIV-associated dementia, mitochondrial dysfunction, and oxidative stress Mitochondrion 4 2004 119 129
    • (2004) Mitochondrion , vol.4 , pp. 119-129
    • Valcour, V.1    Shiramizu, B.2
  • 26
    • 21644456953 scopus 로고    scopus 로고
    • Flow injection spectrophotometric system for N-acetyl-l-cysteine determination in pharmaceuticals
    • A.L. de Toledo Fornazari, W.T. Suarez, H.J. Vieira, and O. Fatibello-Filho Flow injection spectrophotometric system for N-acetyl-l-cysteine determination in pharmaceuticals Acta Chim. Slov. 52 2005 164 167
    • (2005) Acta Chim. Slov. , vol.52 , pp. 164-167
    • De Toledo Fornazari, A.L.1    Suarez, W.T.2    Vieira, H.J.3    Fatibello-Filho, O.4
  • 27
    • 0032562463 scopus 로고    scopus 로고
    • Analysis of cysteine and N-acetylcysteine in human plasma by high-performance liquid chromatography at the basal state and after oral administration of N-acetylcysteine
    • D. Tsikas, J. Sandmann, M. Ikic, J. Fauler, D.O. Stichtenoth, and J.C. Frölich Analysis of cysteine and N-acetylcysteine in human plasma by high-performance liquid chromatography at the basal state and after oral administration of N-acetylcysteine J. Chromatogr. B: Biomed. Sci. Appl. 708 1998 55 60
    • (1998) J. Chromatogr. B: Biomed. Sci. Appl. , vol.708 , pp. 55-60
    • Tsikas, D.1    Sandmann, J.2    Ikic, M.3    Fauler, J.4    Stichtenoth, D.O.5    Frölich, J.C.6
  • 28
    • 0037205954 scopus 로고    scopus 로고
    • Fluorimetric determination of some thiol compounds in their dosage forms
    • S.M. Al-Ghannam, A. El-Brashy, and B. Al-Farhan Fluorimetric determination of some thiol compounds in their dosage forms Farmaco 57 2002 625 629
    • (2002) Farmaco , vol.57 , pp. 625-629
    • Al-Ghannam, S.M.1    El-Brashy, A.2    Al-Farhan, B.3
  • 29
    • 18444400579 scopus 로고    scopus 로고
    • Electrocatalytic oxidation of N-acetyl-l-cysteine by acetylferrocene at glassy carbon electrode
    • Z.N. Gao, J. Zhang, and W.Y. Liu Electrocatalytic oxidation of N-acetyl-l-cysteine by acetylferrocene at glassy carbon electrode J. Electroanal. Chem. 580 2005 9 16
    • (2005) J. Electroanal. Chem. , vol.580 , pp. 9-16
    • Gao, Z.N.1    Zhang, J.2    Liu, W.Y.3
  • 30
    • 51349154548 scopus 로고    scopus 로고
    • Palladized aluminum electrode covered by Prussian blue film as an effective transducer for electrocatalytic oxidation and hydrodynamic amperometry of N-acetyl-cysteine and glutathione
    • M. Pournaghi-Azar, and F. Ahour Palladized aluminum electrode covered by Prussian blue film as an effective transducer for electrocatalytic oxidation and hydrodynamic amperometry of N-acetyl-cysteine and glutathione J. Electroanal. Chem. 622 2008 22 28
    • (2008) J. Electroanal. Chem. , vol.622 , pp. 22-28
    • Pournaghi-Azar, M.1    Ahour, F.2
  • 31
    • 33644977519 scopus 로고    scopus 로고
    • Voltammetric determination of N-acetylcysteine using a carbon paste electrode modified with copper (II) hexacyanoferrate (III)
    • W.T. Suarez, L.H. Marcolino Jr., and O. Fatibello-Filho Voltammetric determination of N-acetylcysteine using a carbon paste electrode modified with copper (II) hexacyanoferrate (III) Microchem. J. 82 2006 163 167
    • (2006) Microchem. J. , vol.82 , pp. 163-167
    • Suarez, W.T.1    Marcolino, Jr.L.H.2    Fatibello-Filho, O.3
  • 32
    • 77955709669 scopus 로고    scopus 로고
    • Catechol as an electrochemical indicator for voltammetric determination of N-acetyl-l-cysteine in aqueous media at the surface of carbon paste electrode
    • J. Raoof, R. Ojani, M. Amiri-Aref, and F. Chekin Catechol as an electrochemical indicator for voltammetric determination of N-acetyl-l-cysteine in aqueous media at the surface of carbon paste electrode J. Appl. Electrochem. 40 2010 1357 1363
    • (2010) J. Appl. Electrochem. , vol.40 , pp. 1357-1363
    • Raoof, J.1    Ojani, R.2    Amiri-Aref, M.3    Chekin, F.4
  • 33
    • 72249102117 scopus 로고    scopus 로고
    • Fabrication of nanocomposite containing naphthoquinone and nanogold supported on poly (2,6-pyridinedicarboxylic acid) film for voltammetric determination of N-acetyl-l-cysteine
    • J.B. Raoof, R. Ojani, F. Chekin, M. Jahanshahi, and S. Rashid Nadimi Fabrication of nanocomposite containing naphthoquinone and nanogold supported on poly (2,6-pyridinedicarboxylic acid) film for voltammetric determination of N-acetyl-l-cysteine Electroanalysis 21 2009 2674 2679
    • (2009) Electroanalysis , vol.21 , pp. 2674-2679
    • Raoof, J.B.1    Ojani, R.2    Chekin, F.3    Jahanshahi, M.4    Rashid Nadimi, S.5
  • 34
    • 0017242220 scopus 로고
    • Probing brain chemistry with electroanalytical techniques
    • R.N. Adams Probing brain chemistry with electroanalytical techniques Anal. Chem. 48 1976 1126A 1138A
    • (1976) Anal. Chem. , vol.48
    • Adams, R.N.1
  • 35
    • 33645856159 scopus 로고    scopus 로고
    • Voltammetric studies of an oracet blue modified glassy carbon electrode and its application for the simultaneous determination of dopamine, ascorbic acid and uric acid
    • H.R. Zare, N. Rajabzadeh, N. Nasirizadeh, and M. Mazloum Ardakani Voltammetric studies of an oracet blue modified glassy carbon electrode and its application for the simultaneous determination of dopamine, ascorbic acid and uric acid J. Electroanal. Chem. 589 2006 60 69
    • (2006) J. Electroanal. Chem. , vol.589 , pp. 60-69
    • Zare, H.R.1    Rajabzadeh, N.2    Nasirizadeh, N.3    Mazloum Ardakani, M.4
  • 36
    • 16344378453 scopus 로고    scopus 로고
    • Development of a sensor based on tetracyanoethylenide (LiTCNE)/poly-l-lysine (PLL) for dopamine determination
    • R.C.S. Luz, F.S. Damos, A.B. Oliveira, J. Beck, and L.T. Kubota Development of a sensor based on tetracyanoethylenide (LiTCNE)/poly-l-lysine (PLL) for dopamine determination Electrochim. Acta 50 2005 2675 2683
    • (2005) Electrochim. Acta , vol.50 , pp. 2675-2683
    • Luz, R.C.S.1    Damos, F.S.2    Oliveira, A.B.3    Beck, J.4    Kubota, L.T.5
  • 37
    • 38349096689 scopus 로고    scopus 로고
    • Electrocatalytic oxidation and voltammetric determination of dopamine at a Nafion/carbon-coated iron nanoparticles-chitosan composite film modified electrode
    • G.S. Lai, H.L. Zhang, and D.Y. Han Electrocatalytic oxidation and voltammetric determination of dopamine at a Nafion/carbon-coated iron nanoparticles-chitosan composite film modified electrode Microchim. Acta 160 2008 233 239
    • (2008) Microchim. Acta , vol.160 , pp. 233-239
    • Lai, G.S.1    Zhang, H.L.2    Han, D.Y.3
  • 38
    • 14544297799 scopus 로고    scopus 로고
    • Electrochemical properties of a tetrabromo-p-benzoquinone modified carbon paste electrode. Application to the simultaneous determination of ascorbic acid, dopamine and uric acid
    • H. Zare, N. Nasirizadeh, and M. Mazloum Ardakani Electrochemical properties of a tetrabromo-p-benzoquinone modified carbon paste electrode. Application to the simultaneous determination of ascorbic acid, dopamine and uric acid J. Electroanal. Chem. 577 2005 25 33
    • (2005) J. Electroanal. Chem. , vol.577 , pp. 25-33
    • Zare, H.1    Nasirizadeh, N.2    Mazloum Ardakani, M.3
  • 39
    • 37449009570 scopus 로고    scopus 로고
    • Poly (4-amino-1-1′-azobenzene-3,4′-disulfonic acid) coated electrode for selective detection of dopamine from its interferences
    • S.A. Kumar, C.F. Tang, and S.M. Chen Poly (4-amino-1-1′-azobenzene- 3,4′-disulfonic acid) coated electrode for selective detection of dopamine from its interferences Talanta 74 2008 860 866
    • (2008) Talanta , vol.74 , pp. 860-866
    • Kumar, S.A.1    Tang, C.F.2    Chen, S.M.3
  • 40
    • 81155155895 scopus 로고    scopus 로고
    • Comparison of N-acetylcysteine and ascorbic acid in prevention of renal dysfunction after coronary angioplasty
    • K. Aghasadeghi, and V. Akbari Comparison of N-acetylcysteine and ascorbic acid in prevention of renal dysfunction after coronary angioplasty J. Renovasc. Dis. 6 2008 1 5
    • (2008) J. Renovasc. Dis. , vol.6 , pp. 1-5
    • Aghasadeghi, K.1    Akbari, V.2
  • 41
    • 73149122926 scopus 로고    scopus 로고
    • Simultaneous determination of ascorbic acid, adrenaline and uric acid at a hematoxylin multi-wall carbon nanotube modified glassy carbon electrode
    • H.R. Zare, and N. Nasirizadeh Simultaneous determination of ascorbic acid, adrenaline and uric acid at a hematoxylin multi-wall carbon nanotube modified glassy carbon electrode Sens. Actuators B: Chem. 143 2010 666 672
    • (2010) Sens. Actuators B: Chem. , vol.143 , pp. 666-672
    • Zare, H.R.1    Nasirizadeh, N.2
  • 42
    • 70349860004 scopus 로고    scopus 로고
    • Differential pulse voltammetric simultaneous determination of noradrenalin and acetaminophen using a hematoxylin biosensor
    • N. Nasirizadeh, and H.R. Zare Differential pulse voltammetric simultaneous determination of noradrenalin and acetaminophen using a hematoxylin biosensor Talanta 80 2009 656 663
    • (2009) Talanta , vol.80 , pp. 656-663
    • Nasirizadeh, N.1    Zare, H.R.2
  • 43
    • 18644377007 scopus 로고    scopus 로고
    • Norepinephrine-modified glassy carbon electrode for the simultaneous determination of ascorbic acid and uric acid
    • H.R. Zare, F. Memarzadeh, M.M. Ardakani, M. Namazian, and S. Golabi Norepinephrine-modified glassy carbon electrode for the simultaneous determination of ascorbic acid and uric acid Electrochim. Acta 50 2005 3495 3502
    • (2005) Electrochim. Acta , vol.50 , pp. 3495-3502
    • Zare, H.R.1    Memarzadeh, F.2    Ardakani, M.M.3    Namazian, M.4    Golabi, S.5
  • 44
    • 33645135623 scopus 로고    scopus 로고
    • Electrochemical evaluation of coumestan modified carbon paste electrode: Study on its application as a NADH biosensor in presence of uric acid
    • H.R. Zare, N. Nasirizadeh, S.M. Golabi, M. Namazian, M. Mazloum-Ardakani, and D. Nematollahi Electrochemical evaluation of coumestan modified carbon paste electrode: study on its application as a NADH biosensor in presence of uric acid Sens. Actuators B: Chem. 114 2006 610 617
    • (2006) Sens. Actuators B: Chem. , vol.114 , pp. 610-617
    • Zare, H.R.1    Nasirizadeh, N.2    Golabi, S.M.3    Namazian, M.4    Mazloum-Ardakani, M.5    Nematollahi, D.6
  • 45
    • 0034954294 scopus 로고    scopus 로고
    • Electrocatalytic reduction and determination of dissolved oxygen at a poly (nile blue) modified electrode
    • H. Ju, and C. Shen Electrocatalytic reduction and determination of dissolved oxygen at a poly (nile blue) modified electrode Electroanalysis 13 2001 789 793
    • (2001) Electroanalysis , vol.13 , pp. 789-793
    • Ju, H.1    Shen, C.2
  • 46
    • 49249148639 scopus 로고
    • General expression of the linear potential sweep voltammogram in the case of diffusionless electrochemical systems
    • E. Laviron General expression of the linear potential sweep voltammogram in the case of diffusionless electrochemical systems J. Electroanal. Chem. 101 1979 19 28
    • (1979) J. Electroanal. Chem. , vol.101 , pp. 19-28
    • Laviron, E.1
  • 47
    • 0024681727 scopus 로고
    • Electrocatalytic reactions on carbon fibre electrodes modified by hemine II. Electro-oxidation of hydrazine
    • S. Antoniadou, A. Jannakoudakis, and E. Theodoridou Electrocatalytic reactions on carbon fibre electrodes modified by hemine II. Electro-oxidation of hydrazine Synth. Met. 30 1989 295 304
    • (1989) Synth. Met. , vol.30 , pp. 295-304
    • Antoniadou, S.1    Jannakoudakis, A.2    Theodoridou, E.3
  • 48
    • 0008862607 scopus 로고
    • Heterogeneous (chemically modified electrodes, polymer electrodes) vs. homogeneous catalysis of electrochemical reactions
    • C. Andrieux, and J. Saveant Heterogeneous (chemically modified electrodes, polymer electrodes) vs. homogeneous catalysis of electrochemical reactions J. Electroanal. Chem. Interfac. Electrochem. 93 1978 163 168
    • (1978) J. Electroanal. Chem. Interfac. Electrochem. , vol.93 , pp. 163-168
    • Andrieux, C.1    Saveant, J.2
  • 51
    • 47649128031 scopus 로고    scopus 로고
    • Differential pulse voltammetric determination of N-acetylcysteine by the electrocatalytic oxidation at the surface of carbon nanotube-paste electrode modified with cobalt salophen complexes
    • S. Shahrokhian, Z. Kamalzadeh, A. Bezaatpour, and D.M. Boghaei Differential pulse voltammetric determination of N-acetylcysteine by the electrocatalytic oxidation at the surface of carbon nanotube-paste electrode modified with cobalt salophen complexes Sens. Actuators B: Chem. 133 2008 599 606
    • (2008) Sens. Actuators B: Chem. , vol.133 , pp. 599-606
    • Shahrokhian, S.1    Kamalzadeh, Z.2    Bezaatpour, A.3    Boghaei, D.M.4
  • 52
    • 4344571685 scopus 로고    scopus 로고
    • Electrocatalytic detection of thiols using an edge plane pyrolytic graphite electrode
    • R.R. Moore, C.E. Banks, and R.G. Compton Electrocatalytic detection of thiols using an edge plane pyrolytic graphite electrode Analyst 129 2004 755 758
    • (2004) Analyst , vol.129 , pp. 755-758
    • Moore, R.R.1    Banks, C.E.2    Compton, R.G.3
  • 53
    • 0141494426 scopus 로고    scopus 로고
    • Electrocatalytic and voltammetric determination of sulfhydryl compounds through iron nitroprusside modified graphite paste electrode
    • D.R. Carmo, R.M. Silva, and N.R. Stradiotto Electrocatalytic and voltammetric determination of sulfhydryl compounds through iron nitroprusside modified graphite paste electrode J. Braz. Chem. Soc. 14 2003 616 620
    • (2003) J. Braz. Chem. Soc. , vol.14 , pp. 616-620
    • Carmo, D.R.1    Silva, R.M.2    Stradiotto, N.R.3
  • 54
    • 76949096289 scopus 로고    scopus 로고
    • Ultrasensitive sensing of N-acetyl-l-cysteine using an electrocatalytic transducer of nanoparticles of iron (III) oxide core-cobalt hexacyanoferrate shell
    • H. Heli, S. Majdi, and N. Sattarahmady Ultrasensitive sensing of N-acetyl-l-cysteine using an electrocatalytic transducer of nanoparticles of iron (III) oxide core-cobalt hexacyanoferrate shell Sens. Actuators B: Chem. 145 2010 185 193
    • (2010) Sens. Actuators B: Chem. , vol.145 , pp. 185-193
    • Heli, H.1    Majdi, S.2    Sattarahmady, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.