메뉴 건너뛰기




Volumn 15, Issue 6, 2011, Pages 1001-1006

Accuracy of templates for navigated implantation made by rapid prototyping with DICOM datasets of cone beam computer tomography (CBCT)

Author keywords

CBCT; Dental implant; DICOM; Rapid prototyping

Indexed keywords

BIOMEDICAL AND DENTAL MATERIALS; POLYCARBONATE; POLYCARBOXYLATE CEMENT;

EID: 80955132899     PISSN: 14326981     EISSN: 14363771     Source Type: Journal    
DOI: 10.1007/s00784-010-0468-9     Document Type: Article
Times cited : (12)

References (33)
  • 2
    • 0032240404 scopus 로고    scopus 로고
    • A new volumetric ct machine for dental imaging based on the cone-beam technique: preliminary results
    • Mozzo P, Procacci C, Tacconi A, Martini PT, Andreis IA (1998) A new volumetric ct machine for dental imaging based on the cone-beam technique: preliminary results. Eur Radiol 8(9): 1558-1564.
    • (1998) Eur Radiol , vol.8 , Issue.9 , pp. 1558-1564
    • Mozzo, P.1    Procacci, C.2    Tacconi, A.3    Martini, P.T.4    Andreis, I.A.5
  • 3
    • 17144396303 scopus 로고    scopus 로고
    • Evaluation of transversal slice imaging in the diagnosis of tooth displacement with special consideration of the upper canines
    • Broer N, Fuhrmann A, Bremert S, Schulze D, Kahl-Nieke B (2005) Evaluation of transversal slice imaging in the diagnosis of tooth displacement with special consideration of the upper canines. J Orofac Orthop 66(2): 94-109.
    • (2005) J Orofac Orthop , vol.66 , Issue.2 , pp. 94-109
    • Broer, N.1    Fuhrmann, A.2    Bremert, S.3    Schulze, D.4    Kahl-Nieke, B.5
  • 4
    • 0037743401 scopus 로고    scopus 로고
    • A new low-dose ct examination compared with standard-dose CT in the diagnosis of acute sinusitis
    • Hagtvedt T, Aalokken TM, Notthellen J, Kolbenstvedt A (2003) A new low-dose ct examination compared with standard-dose CT in the diagnosis of acute sinusitis. Eur Radiol 13(5): 976-980.
    • (2003) Eur Radiol , vol.13 , Issue.5 , pp. 976-980
    • Hagtvedt, T.1    Aalokken, T.M.2    Notthellen, J.3    Kolbenstvedt, A.4
  • 5
    • 0642310337 scopus 로고    scopus 로고
    • Dosimetry of two extraoral direct digital imaging devices: NewTom cone beam CT and orthophos plus DS panoramic unit
    • Ludlow JB, Davies-Ludlow LE, Brooks SL (2003) Dosimetry of two extraoral direct digital imaging devices: NewTom cone beam CT and orthophos plus DS panoramic unit. Dentomaxillofac Radiol 32(4): 229-234.
    • (2003) Dentomaxillofac Radiol , vol.32 , Issue.4 , pp. 229-234
    • Ludlow, J.B.1    Davies-Ludlow, L.E.2    Brooks, S.L.3
  • 6
    • 45949102819 scopus 로고    scopus 로고
    • Comparative dosimetry of dental CBCT devices and 64-slice ct for oral and maxillofacial radiology
    • Ludlow JB, Ivanovic M (2008) Comparative dosimetry of dental CBCT devices and 64-slice ct for oral and maxillofacial radiology. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 106(1): 106-114.
    • (2008) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.106 , Issue.1 , pp. 106-114
    • Ludlow, J.B.1    Ivanovic, M.2
  • 9
    • 19044400459 scopus 로고    scopus 로고
    • Clinical application of stereolithographic surgical guides for implant placement: preliminary results
    • Di Giacomo GA, Cury PR, de Araujo NS, Sendyk WR, Sendyk CL (2005) Clinical application of stereolithographic surgical guides for implant placement: preliminary results. J Periodontol 76(4): 503-507.
    • (2005) J Periodontol , vol.76 , Issue.4 , pp. 503-507
    • Di Giacomo, G.A.1    Cury, P.R.2    de Araujo, N.S.3    Sendyk, W.R.4    Sendyk, C.L.5
  • 11
    • 1242264925 scopus 로고    scopus 로고
    • Implant imaging for the dentist
    • Mupparapu M, Singer SR (2004) Implant imaging for the dentist. J Can Dent Assoc 70(1): 32.
    • (2004) J Can Dent Assoc , vol.70 , Issue.1 , pp. 32
    • Mupparapu, M.1    Singer, S.R.2
  • 13
    • 44349108848 scopus 로고    scopus 로고
    • A new method for printer calibration and contour accuracy manufacturing with 3D-print technology
    • Stopp S, Wolff T, Irlinger F, Lueth T (2008) A new method for printer calibration and contour accuracy manufacturing with 3D-print technology. Rapid Prototyping J 14(3): 167-172.
    • (2008) Rapid Prototyping J , vol.14 , Issue.3 , pp. 167-172
    • Stopp, S.1    Wolff, T.2    Irlinger, F.3    Lueth, T.4
  • 14
    • 44349131686 scopus 로고    scopus 로고
    • Manufacturing drill templates for dental implantology using a 3D printer
    • 1st edn., W. Freysinger, S. Weber, and M. Caversaccio (Eds.), Innsbruck: Pro-Business
    • Stopp S, Deppe H, Lueth T (2007) Manufacturing drill templates for dental implantology using a 3D printer. In: Freysinger W, Weber S, Caversaccio M (eds) Computer aided surgery around the head cas-h 2007, 1st edn. Pro-Business, Innsbruck, pp 144-146.
    • (2007) Computer Aided Surgery around the Head Cas-H 2007 , pp. 144-146
    • Stopp, S.1    Deppe, H.2    Lueth, T.3
  • 15
    • 68549115350 scopus 로고    scopus 로고
    • A systematic review on the accuracy and the clinical outcome of computer-guided template-based implant dentistry
    • Schneider D, Marquardt P, Zwahlen M, Jung RE (2009) A systematic review on the accuracy and the clinical outcome of computer-guided template-based implant dentistry. Clin Oral Implants Res 20(Suppl 4): 73-86.
    • (2009) Clin Oral Implants Res , vol.20 , Issue.SUPPL. 4 , pp. 73-86
    • Schneider, D.1    Marquardt, P.2    Zwahlen, M.3    Jung, R.E.4
  • 16
    • 0035487689 scopus 로고    scopus 로고
    • Clinical application of a new compact CT system to assess 3-D images for the preoperative treatment planning of implants in the posterior mandible a case report
    • Ito K, Gomi Y, Sato S, Arai Y, Shinoda K (2001) Clinical application of a new compact CT system to assess 3-D images for the preoperative treatment planning of implants in the posterior mandible a case report. Clin Oral Implants Res 12(5): 539-542.
    • (2001) Clin Oral Implants Res , vol.12 , Issue.5 , pp. 539-542
    • Ito, K.1    Gomi, Y.2    Sato, S.3    Arai, Y.4    Shinoda, K.5
  • 17
    • 68949085280 scopus 로고    scopus 로고
    • Cone-beam CT for preoperative implant planning in the posterior mandible: visibility of anatomic landmarks
    • Lofthag-Hansen S, Grondahl K, Ekestubbe A (2009) Cone-beam CT for preoperative implant planning in the posterior mandible: visibility of anatomic landmarks. Clin Implant Dent Relat Res 11(3): 246-255.
    • (2009) Clin Implant Dent Relat Res , vol.11 , Issue.3 , pp. 246-255
    • Lofthag-Hansen, S.1    Grondahl, K.2    Ekestubbe, A.3
  • 18
    • 3042557818 scopus 로고    scopus 로고
    • Clinical application of a new cone-beam computerized tomography system to assess multiple two-dimensional images for the preoperative treatment planning of maxillary implants: case reports
    • Sato S, Arai Y, Shinoda K, Ito K (2004) Clinical application of a new cone-beam computerized tomography system to assess multiple two-dimensional images for the preoperative treatment planning of maxillary implants: case reports. Quintessence Int 35(7): 525-528.
    • (2004) Quintessence Int , vol.35 , Issue.7 , pp. 525-528
    • Sato, S.1    Arai, Y.2    Shinoda, K.3    Ito, K.4
  • 19
    • 34347361565 scopus 로고    scopus 로고
    • Immediately loaded CAD-CAM manufactured fixed complete dentures using flapless implant placement procedures: a cohort study of consecutive patients
    • Sanna AM, Molly L, van Steenberghe D (2007) Immediately loaded CAD-CAM manufactured fixed complete dentures using flapless implant placement procedures: a cohort study of consecutive patients. J Prosthet Dent 97(6): 331-339.
    • (2007) J Prosthet Dent , vol.97 , Issue.6 , pp. 331-339
    • Sanna, A.M.1    Molly, L.2    van Steenberghe, D.3
  • 20
    • 58149175475 scopus 로고    scopus 로고
    • CAD/CAM fabrication and clinical application of surgical template and bone model in oral implant surgery
    • Sohmura T, Kusumoto N, Otani T, Yamada S, Wakabayashi K, Yatani H (2009) CAD/CAM fabrication and clinical application of surgical template and bone model in oral implant surgery. Clin Oral Implants Res 20(1): 87-93.
    • (2009) Clin Oral Implants Res , vol.20 , Issue.1 , pp. 87-93
    • Sohmura, T.1    Kusumoto, N.2    Otani, T.3    Yamada, S.4    Wakabayashi, K.5    Yatani, H.6
  • 21
    • 20744446711 scopus 로고    scopus 로고
    • A computed tomographic scan-derived customized surgical template and fixed prosthesis for flapless surgery and immediate loading of implants in fully edentulous maxillae: a prospective multicenter study
    • van Steenberghe D, Glauser R, Blomback U, Andersson M, Schutyser F, Pettersson A, Wendelhag I (2005) A computed tomographic scan-derived customized surgical template and fixed prosthesis for flapless surgery and immediate loading of implants in fully edentulous maxillae: a prospective multicenter study. Clin Implant Dent Relat Res 7(Suppl 1): S111-S120.
    • (2005) Clin Implant Dent Relat Res , vol.7 , Issue.SUPPL. 1
    • van Steenberghe, D.1    Glauser, R.2    Blomback, U.3    Andersson, M.4    Schutyser, F.5    Pettersson, A.6    Wendelhag, I.7
  • 24
    • 33745077052 scopus 로고    scopus 로고
    • Advances in three dimensional printing-state of the art and future perspectives
    • Dimitrov D, Schreve K, de Beer N (2006) Advances in three dimensional printing-state of the art and future perspectives. Rapid Prototyping J 12(3): 136-147.
    • (2006) Rapid Prototyping J , vol.12 , Issue.3 , pp. 136-147
    • Dimitrov, D.1    Schreve, K.2    de Beer, N.3
  • 25
    • 31544443892 scopus 로고    scopus 로고
    • Investigating the achievable accuracy of three dimensional printing
    • Dimitrov D, van Wijck W, Schreve K, de Beer N (2006) Investigating the achievable accuracy of three dimensional printing. Rapid Prototyping J 12(1): 42-52.
    • (2006) Rapid Prototyping J , vol.12 , Issue.1 , pp. 42-52
    • Dimitrov, D.1    van Wijck, W.2    Schreve, K.3    de Beer, N.4
  • 26
    • 67349248556 scopus 로고    scopus 로고
    • Generation of three-dimensional prototype models based on cone beam computed tomography
    • Lambrecht JT, Berndt DC, Schumacher R, Zehnder M (2009) Generation of three-dimensional prototype models based on cone beam computed tomography. Int J Comput Assist Radiol Surg 4(2): 175-180.
    • (2009) Int J Comput Assist Radiol Surg , vol.4 , Issue.2 , pp. 175-180
    • Lambrecht, J.T.1    Berndt, D.C.2    Schumacher, R.3    Zehnder, M.4
  • 27
    • 77958093300 scopus 로고    scopus 로고
    • Accuracy and surgical feasibility of a CBCT-based stereolithographic surgical guide aiding autotransplantation of teeth: In vitro validation
    • doi: 10. 1111/j. 1365-2842. 2010. 02107. x
    • Shahbazian M, Jacobs R, Wyatt J, Willems G, Pattijn V, Dhoore E, C VANL, Vinckier F (2010) Accuracy and surgical feasibility of a CBCT-based stereolithographic surgical guide aiding autotransplantation of teeth: in vitro validation. J Oral Rehabil. doi: 10. 1111/j. 1365-2842. 2010. 02107. x.
    • (2010) J Oral Rehabil
    • Shahbazian, M.1    Jacobs, R.2    Wyatt, J.3    Willems, G.4    Pattijn, V.5    Dhoore, E.6    Vanl, C.7    Vinckier, F.8
  • 28
    • 0036977871 scopus 로고    scopus 로고
    • Precision of transfer of preoperative planning for oral implants based on cone-beam CT-scan images through a robotic drilling machine
    • Fortin T, Champleboux G, Bianchi S, Buatois H, Coudert JL (2002) Precision of transfer of preoperative planning for oral implants based on cone-beam CT-scan images through a robotic drilling machine. Clin Oral Implants Res 13(6): 651-656.
    • (2002) Clin Oral Implants Res , vol.13 , Issue.6 , pp. 651-656
    • Fortin, T.1    Champleboux, G.2    Bianchi, S.3    Buatois, H.4    Coudert, J.L.5
  • 29
    • 74049104809 scopus 로고    scopus 로고
    • Loma Linda guide: a stereolithographically designed surgical template: technique paper
    • Kleinman A, Leyva F, Lozada J, Patel RD (2009) Loma Linda guide: a stereolithographically designed surgical template: technique paper. J Oral Implantol 35(5): 238-244.
    • (2009) J Oral Implantol , vol.35 , Issue.5 , pp. 238-244
    • Kleinman, A.1    Leyva, F.2    Lozada, J.3    Patel, R.D.4
  • 30
    • 38949083108 scopus 로고    scopus 로고
    • The management of a severely resorbed edentulous maxilla using a bone graft and a CAD/CAM-guided immediately loaded definitive implant prosthesis: a clinical report
    • Cheng AC, Tee-Khin N, Siew-Luen C, Lee H, Wee AG (2008) The management of a severely resorbed edentulous maxilla using a bone graft and a CAD/CAM-guided immediately loaded definitive implant prosthesis: a clinical report. J Prosthet Dent 99(2): 85-90.
    • (2008) J Prosthet Dent , vol.99 , Issue.2 , pp. 85-90
    • Cheng, A.C.1    Tee-Khin, N.2    Siew-Luen, C.3    Lee, H.4    Wee, A.G.5
  • 32
    • 84861813549 scopus 로고    scopus 로고
    • Deformation of stereolithographically produced surgical guides: An observational case series report
    • doi: 10. 1111/j. 1708-8208. 2010. 00268. x
    • Stumpel LJ (2010) Deformation of stereolithographically produced surgical guides: an observational case series report. Clin Implant Dent Relat Res. doi: 10. 1111/j. 1708-8208. 2010. 00268. x.
    • (2010) Clin Implant Dent Relat Res
    • Stumpel, L.J.1
  • 33
    • 77953132558 scopus 로고    scopus 로고
    • Rehabilitation of totally atrophied maxilla by means of four zygomatic implants and fixed prosthesis: a 6-40-month follow-up
    • Stievenart M, Malevez C (2010) Rehabilitation of totally atrophied maxilla by means of four zygomatic implants and fixed prosthesis: a 6-40-month follow-up. Int J Oral Maxillofac Surg 39(4): 358-363.
    • (2010) Int J Oral Maxillofac Surg , vol.39 , Issue.4 , pp. 358-363
    • Stievenart, M.1    Malevez, C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.