메뉴 건너뛰기




Volumn 19, Issue 23, 2011, Pages 23249-23257

Self consistent, absolute calibration technique for photon number resolving detectors

Author keywords

[No Author keywords available]

Indexed keywords

CALIBRATION; DETECTORS; QUANTUM OPTICS; QUANTUM THEORY;

EID: 80755167704     PISSN: None     EISSN: 10944087     Source Type: Journal    
DOI: 10.1364/OE.19.023249     Document Type: Article
Times cited : (50)

References (54)
  • 1
    • 72449202040 scopus 로고    scopus 로고
    • Single-photon detectors for optical quantum information applications
    • and ref.s therein
    • R. H. Hadfield, "Single-photon detectors for optical quantum information applications," Nature Photon. 3, 696- 705 (2009) and ref.s therein.
    • (2009) Nature Photon. , vol.3 , pp. 696-705
    • Hadfield, R.H.1
  • 2
    • 36248977169 scopus 로고    scopus 로고
    • Detecting quantum light
    • and ref.s therein
    • C. Silberhorn, "Detecting quantum light," Contemp. Phys. 48, 143-156 (2007) and ref.s therein.
    • (2007) Contemp. Phys. , vol.48 , pp. 143-156
    • Silberhorn, C.1
  • 3
    • 77957864518 scopus 로고    scopus 로고
    • Photometry, radiometry and 'the candela': Evolution in the classical and quantum world
    • J. C. Zwinkels, E. Ikonen, N. P. Fox, G. Ulm, and M. L. Rastello, "Photometry, radiometry and 'the candela': Evolution in the classical and quantum world," Metrologia 47, R15-R32 (2010).
    • (2010) Metrologia , vol.47
    • Zwinkels, J.C.1    Ikonen, E.2    Fox, N.P.3    Ulm, G.4    Rastello, M.L.5
  • 4
    • 77955697349 scopus 로고    scopus 로고
    • Super-resolution at the shot-noise limit with coherent states and photon-number-resolving detectors
    • Y. Gao, P. M. Anisimov, C. F. Wildfeuer, J. Luine, H. Lee, and J. P. Dowling, "Super-resolution at the shot-noise limit with coherent states and photon-number-resolving detectors," J.Opt. Soc. Am. B 27, A170-A174 (2010).
    • (2010) J.Opt. Soc. Am. B , vol.27
    • Gao, Y.1    Anisimov, P.M.2    Wildfeuer, C.F.3    Luine, J.4    Lee, H.5    Dowling, J.P.6
  • 5
    • 19844373529 scopus 로고    scopus 로고
    • Research on hidden variable theories: A review of recent progresses
    • and ref.s therein
    • M. Genovese, "Research on hidden variable theories: A review of recent progresses," Phys. Rep. 413, 319-396 (2005) and ref.s therein.
    • (2005) Phys. Rep. , vol.413 , pp. 319-396
    • Genovese, M.1
  • 6
    • 77950503271 scopus 로고    scopus 로고
    • Experimental realization of sub-shot-noise quantum imaging
    • G. Brida, M. Genovese, and I. Ruo Berchera, "Experimental realization of sub-shot-noise quantum imaging," Nature Photon. 4, 227-230 (2010).
    • (2010) Nature Photon. , vol.4 , pp. 227-230
    • Brida, G.1    Genovese, M.2    Ruo Berchera, I.3
  • 7
    • 67649535645 scopus 로고    scopus 로고
    • Standardization of quantum key distribution and the ETSI standardization initiative ISG-QKD
    • and ref.s therein
    • T. Laenger, and G. Lenhart, "Standardization of quantum key distribution and the ETSI standardization initiative ISG-QKD," New J. Phys. 11, 055051 (2009) and ref.s therein.
    • (2009) New J. Phys. , vol.11 , pp. 055051
    • Laenger, T.1    Lenhart, G.2
  • 8
    • 72449144135 scopus 로고    scopus 로고
    • Photonic quantum technologies
    • and ref.s therein
    • J. L. O'Brien, A. Furusawa, and J. Vučković, "Photonic quantum technologies," Nature Photon. 3, 687-695 (2009) and ref.s therein.
    • (2009) Nature Photon. , vol.3 , pp. 687-695
    • O'Brien, J.L.1    Furusawa, A.2    Vučković, J.3
  • 9
    • 34248369425 scopus 로고    scopus 로고
    • Quantum communication
    • and ref.s therein
    • N. Gisin and R. Thew, "Quantum communication," Nature Photon. 1, 165-171 (2007) and ref.s therein.
    • (2007) Nature Photon. , vol.1 , pp. 165-171
    • Gisin, N.1    Thew, R.2
  • 10
    • 34347328290 scopus 로고    scopus 로고
    • Photon-number-resolving detector with 10 bits of resolution
    • L. A. Jiang, E. A. Dauler, and J. T. Chang, "Photon-number-resolving detector with 10 bits of resolution," Phys. Rev. A 75, 062325 (2007).
    • (2007) Phys. Rev. A , vol.75 , pp. 062325
    • Jiang, L.A.1    Dauler, E.A.2    Chang, J.T.3
  • 13
    • 4544285204 scopus 로고    scopus 로고
    • Photon-number resolution using time-multiplexed single-photon detectors
    • M. J. Fitch, B. C. Jacobs, T. B. Pittman, and J. D. Franson, "Photon-number resolution using time-multiplexed single-photon detectors," Phys. Rev. A 68, 043814 (2003).
    • (2003) Phys. Rev. A , vol.68 , pp. 043814
    • Fitch, M.J.1    Jacobs, B.C.2    Pittman, T.B.3    Franson, J.D.4
  • 14
    • 4944224880 scopus 로고    scopus 로고
    • Counting photoelectrons in the response of a photomultiplier tube to single picosecond light pulses
    • G. Zambra, M. Bondani, A. S. Spinelli, F. Paleari, and A. Andreoni, "Counting photoelectrons in the response of a photomultiplier tube to single picosecond light pulses," Rev. Sci. Instrum. 75, 2762 (2004).
    • (2004) Rev. Sci. Instrum. , vol.75 , pp. 2762
    • Zambra, G.1    Bondani, M.2    Spinelli, A.S.3    Paleari, F.4    Andreoni, A.5
  • 15
    • 76649086133 scopus 로고    scopus 로고
    • Light statistics by non-calibrated linear photodetectors
    • M.Bondani, A. Allevi, and A. Andreoni, "Light Statistics by Non-Calibrated Linear Photodetectors," Advanced Science Letters 2, 463-468 (2009).
    • (2009) Advanced Science Letters , vol.2 , pp. 463-468
    • Bondani, M.1    Allevi, A.2    Andreoni, A.3
  • 18
    • 0005586932 scopus 로고    scopus 로고
    • Multiphoton detection using visible light photon counter
    • J. Kim, S. Takeuchi, Y. Yamamoto, and H. H. Hogue, "Multiphoton detection using visible light photon counter," Appl. Phys. Lett. , 74, 902 (1999).
    • (1999) Appl. Phys. Lett. , vol.74 , pp. 902
    • Kim, J.1    Takeuchi, S.2    Yamamoto, Y.3    Hogue, H.H.4
  • 21
    • 77949628890 scopus 로고    scopus 로고
    • Enhancing image contrast using coherent states and photon number resolving detectors
    • A. J. Pearlman, A. Ling, E. A. Goldschmidt, C. F. Wildfeuer, J. Fan, and A. Migdall, "Enhancing image contrast using coherent states and photon number resolving detectors," Opt. Express 18, 6033-6039 (2010).
    • (2010) Opt. Express , vol.18 , pp. 6033-6039
    • Pearlman, A.J.1    Ling, A.2    Goldschmidt, E.A.3    Wildfeuer, C.F.4    Fan, J.5    Migdall, A.6
  • 23
    • 77950896687 scopus 로고    scopus 로고
    • Sub-shot-noise-limit discrimination of on-off keyed coherent signals via a quantum receiver with a superconducting transition edge sensor
    • K. Tsujino, D. Fukuda, G. Fujii, S. Inoue, M. Fujiwara, M. Takeoka, and M. Sasaki, "Sub-shot-noise-limit discrimination of on-off keyed coherent signals via a quantum receiver with a superconducting transition edge sensor," Opt. Express 18, 8107-8114 (2010).
    • (2010) Opt. Express , vol.18 , pp. 8107-8114
    • Tsujino, K.1    Fukuda, D.2    Fujii, G.3    Inoue, S.4    Fujiwara, M.5    Takeoka, M.6    Sasaki, M.7
  • 24
    • 0032613362 scopus 로고    scopus 로고
    • Correlated-photon metrology without absolute standards
    • and ref.s therein
    • A. Migdall, "Correlated-photon metrology without absolute standards," Phys. Today 52, 41-46 (1999) and ref.s therein.
    • (1999) Phys. Today , vol.52 , pp. 41-46
    • Migdall, A.1
  • 25
    • 34147200139 scopus 로고    scopus 로고
    • Twin-photon techniques for photo-detector calibration
    • and ref.s therein
    • G. Brida, M. Genovese, and M. Gramegna, "Twin-photon techniques for photo-detector calibration," Laser Physics Lett. 3, 115-123 (2006) and ref.s therein.
    • (2006) Laser Physics Lett. , vol.3 , pp. 115-123
    • Brida, G.1    Genovese, M.2    Gramegna, M.3
  • 26
    • 67651224986 scopus 로고    scopus 로고
    • Quantum radiometry
    • and ref.s therein
    • S. V. Polyakov, and A. L. Migdall, "Quantum radiometry," J. Mod. Opt. 56, 1045-1052 (2009) and ref.s therein.
    • (2009) J. Mod. Opt. , vol.56 , pp. 1045-1052
    • Polyakov, S.V.1    Migdall, A.L.2
  • 27
    • 0002033379 scopus 로고
    • Observation of simultaneity in parametric production of optical photon pairs
    • D. C. Burnham and D. L. Weinberg, "Observation of Simultaneity in Parametric Production of Optical Photon Pairs," Phys. Rev. Lett. 25, 84-87 (1970).
    • (1970) Phys. Rev. Lett. , vol.25 , pp. 84-87
    • Burnham, D.C.1    Weinberg, D.L.2
  • 28
    • 0001357124 scopus 로고
    • Utilization of vacuum fluctuations as an optical brightness standard
    • D. N. Klyshko, "Utilization of vacuum fluctuations as an optical brightness standard," Sov. J. Quantum Electron. 7, 591 (1977).
    • (1977) Sov. J. Quantum Electron. , vol.7 , pp. 591
    • Klyshko, D.N.1
  • 29
    • 0028421022 scopus 로고
    • Absolute efficiency and timeresponse measurement of single-photon detectors
    • P. G. Kwiat, A. M. Steinberg, R. Y. Chiao, P. H. Eberhard, and M. D. Petroff, "Absolute efficiency and timeresponse measurement of single-photon detectors," Appl. Opt. 33, 1844-1853 (1994).
    • (1994) Appl. Opt. , vol.33 , pp. 1844-1853
    • Kwiat, P.G.1    Steinberg, A.M.2    Chiao, R.Y.3    Eberhard, P.H.4    Petroff, M.D.5
  • 30
    • 0040924633 scopus 로고    scopus 로고
    • Measuring absolute infrared spectral radiance with correlated photons: New arrangements for improved uncertainty and extended IR range
    • E. Dauler, A. L. Migdall, N. Boeuf, R. U. Datla, A. Muller, and A. Sergienko, "Measuring absolute infrared spectral radiance with correlated photons: New arrangements for improved uncertainty and extended IR range," Metrologia 35, 295 (1998).
    • (1998) Metrologia , vol.35 , pp. 295
    • Dauler, E.1    Migdall, A.L.2    Boeuf, N.3    Datla, R.U.4    Muller, A.5    Sergienko, A.6
  • 31
    • 0034470783 scopus 로고    scopus 로고
    • Towards an uncertainty budget in quantum-efficiency measurements with parametric fluorescence
    • G. Brida, S. Castelletto, I. P. Degiovanni, M. Genovese, C. Novero, and M. L. Rastello, "Towards an uncertainty budget in quantum-efficiency measurements with parametric fluorescence," Metrologia 37, 629 (2000).
    • (2000) Metrologia , vol.37 , pp. 629
    • Brida, G.1    Castelletto, S.2    Degiovanni, I.P.3    Genovese, M.4    Novero, C.5    Rastello, M.L.6
  • 32
    • 0000641958 scopus 로고
    • Absolute measurement of detector quantum efficiency using parametric downconversion
    • J. G. Rarity, K. D. Ridley, and P. R. Tapster, "Absolute measurement of detector quantum efficiency using parametric downconversion," Appl. Opt. 26, 4616-4619 (1987).
    • (1987) Appl. Opt. , vol.26 , pp. 4616-4619
    • Rarity, J.G.1    Ridley, K.D.2    Tapster, P.R.3
  • 33
    • 0038803445 scopus 로고    scopus 로고
    • Evaluation of statistical noise in measurements based on correlated photons
    • S. Castelletto, I. P. Degiovanni, and M. L. Rastello, "Evaluation of statistical noise in measurements based on correlated photons," J. Opt. Soc. Am. B 19, 1247-1258 (2002).
    • (2002) J. Opt. Soc. Am. B , vol.19 , pp. 1247-1258
    • Castelletto, S.1    Degiovanni, I.P.2    Rastello, M.L.3
  • 35
    • 0037140627 scopus 로고    scopus 로고
    • Intercomparison of a correlated-photon- based method to measure detector quantum efficiency
    • A. L. Migdall, S. Castelletto, I. P. Degiovanni, and M. L. Rastello, "Intercomparison of a Correlated-Photon- Based Method to Measure Detector Quantum Efficiency," Appl. Opt. 41, 2914-2922 (2002).
    • (2002) Appl. Opt. , vol.41 , pp. 2914-2922
    • Migdall, A.L.1    Castelletto, S.2    Degiovanni, I.P.3    Rastello, M.L.4
  • 36
    • 33847240527 scopus 로고    scopus 로고
    • High accuracy verification of a correlated-photon-based method for determining photoncounting detection efficiency
    • S.V. Polyakov and A.L. Migdall, "High accuracy verification of a correlated-photon-based method for determining photoncounting detection efficiency," Opt. Express 15, 1390-1407 (2007).
    • (2007) Opt. Express , vol.15 , pp. 1390-1407
    • Polyakov, S.V.1    Migdall, A.L.2
  • 37
    • 84894395935 scopus 로고    scopus 로고
    • Low optical power reference detector implemented in the validation of two independent techniques for calibrating photon-counting detectors
    • submitted
    • J. Y. Cheung, C. J. Chunnilall, G. Porrovecchio, M. Smid, E. Theocharous, "Low optical power reference detector implemented in the validation of two independent techniques for calibrating photon-counting detectors," Opt. Express (submitted).
    • Opt. Express
    • Cheung, J.Y.1    Chunnilall, C.J.2    Porrovecchio, G.3    Smid, M.4    Theocharous, E.5
  • 38
    • 33751205898 scopus 로고    scopus 로고
    • Possibility of absolute calibration of analog detectors by using parametric downconversion: A systematic study
    • G. Brida, M. Genovese, I. Ruo-Berchera, M. Chekhova, and A. Penin, "Possibility of absolute calibration of analog detectors by using parametric downconversion: A systematic study," J. Opt. Soc. Am. B 23, 2185-2193 (2006).
    • (2006) J. Opt. Soc. Am. B , vol.23 , pp. 2185-2193
    • Brida, G.1    Genovese, M.2    Ruo-Berchera, I.3    Chekhova, M.4    Penin, A.5
  • 39
    • 50049122417 scopus 로고    scopus 로고
    • Analysis of the possibility of analog detectors calibration by exploiting stimulated parametric down conversion
    • G. Brida, M. Chekhova, M. Genovese, and I. Ruo-Berchera, "Analysis of the possibility of analog detectors calibration by exploiting stimulated parametric down conversion," Opt. Express 16, 12550-12558 (2008).
    • (2008) Opt. Express , vol.16 , pp. 12550-12558
    • Brida, G.1    Chekhova, M.2    Genovese, M.3    Ruo-Berchera, I.4
  • 40
    • 77957978949 scopus 로고    scopus 로고
    • Detection of multimode spatial correlation in PDC and application to the absolute calibration of a CCD camera
    • G. Brida, I. P. Degiovanni, M. Genovese, M. L. Rastello, and I. Ruo Berchera, "Detection of multimode spatial correlation in PDC and application to the absolute calibration of a CCD camera," Opt. Express 18, 20572-20584 (2010).
    • (2010) Opt. Express , vol.18 , pp. 20572-20584
    • Brida, G.1    Degiovanni, I.P.2    Genovese, M.3    Rastello, M.L.4    Ruo Berchera, I.5
  • 43
    • 40349100279 scopus 로고    scopus 로고
    • Counting near-infrared single-photons with 95% efficiency
    • A.E. Lita, A. J. Miller,and S. W. Nam, "Counting near-infrared single-photons with 95% efficiency," Opt. Express 16, 3032-3040 (2008).
    • (2008) Opt. Express , vol.16 , pp. 3032-3040
    • Lita, A.E.1    Millerand, A.J.2    Nam, S.W.3
  • 47
    • 36448999994 scopus 로고
    • An application of electrothermal feedback for high resolution cryogenic particle detection
    • K. D. Irwin, "An application of electrothermal feedback for high resolution cryogenic particle detection," Appl. Phys. Lett. 66, 1998 (1995).
    • (1995) Appl. Phys. Lett. , vol.66 , pp. 1998
    • Irwin, K.D.1
  • 50
    • 0034470888 scopus 로고    scopus 로고
    • Theoretical aspects of photon number measurement
    • S. Castelletto, I. P. Degiovanni, M. L. Rastello, "Theoretical aspects of photon number measurement," Metrologia 37, 613-616 (2000).
    • (2000) Metrologia , vol.37 , pp. 613-616
    • Castelletto, S.1    Degiovanni, I.P.2    Rastello, M.L.3
  • 51
    • 0003492099 scopus 로고
    • Guide to the expression of uncertainty in measurement
    • Guide to the Expression of Uncertainty in Measurement, ISO (1995).
    • (1995) ISO
  • 53
    • 33847240527 scopus 로고    scopus 로고
    • Incidentally, if one wants to provide a precise estimate of the naked TES based detector quantum efficiency ç it is necessary a careful estimation of the optical transmittance ô , accounting for the coupling efficiency in the optical fiber and the optical losses in the non-linear crystal. According to the results of Ref.s
    • Incidentally, if one wants to provide a precise estimate of the naked TES based detector quantum efficiency ç it is necessary a careful estimation of the optical transmittance ô , accounting for the coupling efficiency in the optical fiber and the optical losses in the non-linear crystal. According to the results of Refs [S.V. Polyakov, A.L. Migdall, Opt. Express 15, 1390 (2007);
    • (2007) Opt. Express , vol.15 , pp. 1390
    • Polyakov, S.V.1    Migdall, A.L.2
  • 54
    • 0039363922 scopus 로고    scopus 로고
    • (submitted)], one could provide an estimate of this parameter with a less than 1% uncertainty
    • J. Y. Cheung et al., Appl. Opt. (submitted)], one could provide an estimate of this parameter with a less than 1% uncertainty.
    • Appl. Opt.
    • Cheung, J.Y.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.