-
1
-
-
0031952417
-
Aortic and hepatic peak enhancement at CT: Effect of contrast medium injection rate - Pharmacokinetic analysis and experimental porcine model
-
K.T. Bae, J.P. Heiken, and J.A. Brink Aortic and hepatic peak enhancement at CT: effect of contrast medium injection rate - pharmacokinetic analysis and experimental porcine model Radiology 206 2 1998 455 464 (Pubitemid 28112962)
-
(1998)
Radiology
, vol.206
, Issue.2
, pp. 455-464
-
-
Bae, K.T.1
Heiken, J.P.2
Brink, J.A.3
-
2
-
-
0033969237
-
Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography
-
D. Fleischmann, G.D. Rubin, A.A. Bankier, and K. Hittmair Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography Radiology 214 2 2000 363 371 (Pubitemid 30077690)
-
(2000)
Radiology
, vol.214
, Issue.2
, pp. 363-371
-
-
Fleischmann, D.1
Rubin, G.D.2
Bankier, A.A.3
Hittmair, K.4
-
3
-
-
0035140219
-
Biphasic and discontinuous injection of contrast material for thin-section helical ct angiography of the whole aorta and iliac arteries
-
Y.H. Choe, L.H. Phyun, and B.K. Han Biphasic and discontinuous injection of contrast material for thin-section helical ct angiography of the whole aorta and iliac arteries AJR Am J Roentgenol 176 2 2001 454 456
-
(2001)
AJR Am J Roentgenol
, vol.176
, Issue.2
, pp. 454-456
-
-
Choe, Y.H.1
Phyun, L.H.2
Han, B.K.3
-
4
-
-
0346218104
-
Effect of Contrast Material Injection Duration and Rate on Aortic Peak Time and Peak Enhancement at Dynamic CT Involving Injection Protocol with Dose Tailored to Patient Weight
-
DOI 10.1148/radiol.2301021008
-
K. Awai, K. Hiraishi, and S. Hori Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight Radiology 230 1 2004 142 150 (Pubitemid 37549795)
-
(2004)
Radiology
, vol.230
, Issue.1
, pp. 142-150
-
-
Awai, K.1
Hiraishi, K.2
Hori, S.3
-
5
-
-
0032458498
-
Optimization of contrast delivery for pulmonary CT angiography
-
DOI 10.1016/S0899-7071(98)00068-0, PII S0899707198000680
-
D.F. Yankelevitz, D. Shaham, A. Shah, J. Rademacker, and C.I. Henschke Optimization of contrast delivery for pulmonary CT angiography Clin Imaging 22 6 1998 398 403 (Pubitemid 29050861)
-
(1998)
Clinical Imaging
, vol.22
, Issue.6
, pp. 398-403
-
-
Yankelevitz, D.F.1
Shaham, D.2
Shah, A.3
Rademacker, J.4
Henschke, C.I.5
-
6
-
-
0030825080
-
Thoracic spiral CT: Delivery of contrast material pushed with injectable saline solution in a power injector
-
K.D. Hopper, T.J. Mosher, C.J. Kasales, T.R. TenHave, D.A. Tully, and J.S. Weaver Thoracic spiral CT: delivery of contrast material pushed with injectable saline solution in a power injector Radiology 205 1 1997 269 271 (Pubitemid 27415160)
-
(1997)
Radiology
, vol.205
, Issue.1
, pp. 269-271
-
-
Hopper, K.D.1
Mosher, T.J.2
Kasales, C.J.3
TenHave, T.R.4
Tully, D.A.5
Weaver, J.S.6
-
7
-
-
0034112337
-
Reduction of contrast material dose and artifacts by a saline flush using a double power injector in helical CT of the thorax
-
P. Haage, T. Schmitz-Rode, D. Hubner, W. Piroth, and R.W. Gunther Reduction of contrast material dose and artifacts by a saline flush using a double power injector in helical CT of the thorax AJR Am J Roentgenol 174 4 2000 1049 1053 (Pubitemid 30180001)
-
(2000)
American Journal of Roentgenology
, vol.174
, Issue.4
, pp. 1049-1053
-
-
Haage, P.1
Schmitz-Rode, T.2
Hubner, D.3
Piroth, W.4
Gunther, R.W.5
-
8
-
-
1842450677
-
Improvement of parenchymal and vascular enchancement using saline flush and power injection for multiple-detector-row abdominal CT
-
DOI 10.1007/s00330-003-2085-3
-
H. Schoellnast, M. Tillich, and H.A. Deutschmann Improvement of parenchymal and vascular enhancement using saline flush and power injection for multiple-detector-row abdominal CT Eur Radiol 14 4 2004 659 664 (Pubitemid 38444580)
-
(2004)
European Radiology
, vol.14
, Issue.4
, pp. 659-664
-
-
Schoellnast, H.1
Tillich, M.2
Deutschmann, H.A.3
Stessel, U.4
Deutschmann, M.J.5
Schaffler, G.J.6
Schoellnast, R.7
Uggowitzer, M.M.8
-
9
-
-
53849098569
-
Dual-energy CT angiography of the lung in patients with suspected pulmonary embolism: Initial results
-
C. Fink, T.R. Johnson, and H.J. Michaely Dual-energy CT angiography of the lung in patients with suspected pulmonary embolism: initial results Rofo 180 10 2008 879 883
-
(2008)
Rofo
, vol.180
, Issue.10
, pp. 879-883
-
-
Fink, C.1
Johnson, T.R.2
Michaely, H.J.3
-
10
-
-
56349165548
-
Dual energy CT for the assessment of lung perfusion - Correlation to scintigraphy
-
S.F. Thieme, C.R. Becker, M. Hacker, K. Nikolaou, M.F. Reiser, and T.R. Johnson Dual energy CT for the assessment of lung perfusion - correlation to scintigraphy Eur J Radiol 68 3 2008 369 374
-
(2008)
Eur J Radiol
, vol.68
, Issue.3
, pp. 369-374
-
-
Thieme, S.F.1
Becker, C.R.2
Hacker, M.3
Nikolaou, K.4
Reiser, M.F.5
Johnson, T.R.6
-
11
-
-
31444454089
-
First performance evaluation of a dual-source CT (DSCT) system
-
DOI 10.1007/s00330-005-2919-2
-
T.G. Flohr, C.H. McCollough, and H. Bruder First performance evaluation of a dual-source CT (DSCT) system Eur Radiol 16 2 2006 256 268 (Pubitemid 43149624)
-
(2006)
European Radiology
, vol.16
, Issue.2
, pp. 256-268
-
-
Flohr, T.G.1
McCollough, C.H.2
Bruder, H.3
Petersilka, M.4
Gruber, K.5
Suss, C.6
Grasruck, M.7
Stierstorfer, K.8
Krauss, B.9
Raupach, R.10
Primak, A.N.11
Kuttner, A.12
Achenbach, S.13
Becker, C.14
Kopp, A.15
Ohnesorge, B.M.16
-
12
-
-
34249023378
-
Dose performance of a 64-channel dual-source CT scanner
-
DOI 10.1148/radiol.2433061165
-
C.H. McCollough, A.N. Primak, and O. Saba Dose performance of a 64-channel dual-source CT scanner Radiology 243 3 2007 775 784 (Pubitemid 46799432)
-
(2007)
Radiology
, vol.243
, Issue.3
, pp. 775-784
-
-
McCollough, C.H.1
Primak, A.N.2
Saba, O.3
Bruder, H.4
Stierstorfer, K.5
Raupach, R.6
Suess, C.7
Schmidt, B.8
Ohnesorge, B.M.9
Flohr, T.G.10
-
13
-
-
34248673159
-
Material differentiation by dual energy CT: Initial experience
-
DOI 10.1007/s00330-006-0517-6
-
T.R. Johnson, B. Krauss, and M. Sedlmair Material differentiation by dual energy CT: initial experience Eur Radiol 17 6 2007 1510 1517 (Pubitemid 46767599)
-
(2007)
European Radiology
, vol.17
, Issue.6
, pp. 1510-1517
-
-
Johnson, T.R.C.1
Krauss, B.2
Sedlmair, M.3
Grasruck, M.4
Bruder, H.5
Morhard, D.6
Fink, C.7
Weckbach, S.8
Lenhard, M.9
Schmidt, B.10
Flohr, T.11
Reiser, M.F.12
Becker, C.R.13
-
14
-
-
0037743441
-
Peripheral pulmonary arteries: Identification at multi-slice spiral CT with 3D reconstruction
-
E. Coche, S. Pawlak, S. Dechambre, and B. Maldague Peripheral pulmonary arteries: identification at multi-slice spiral CT with 3D reconstruction Eur Radiol 13 4 2003 815 822 (Pubitemid 36790566)
-
(2003)
European Radiology
, vol.13
, Issue.4
, pp. 815-822
-
-
Coche, E.1
Pawlak, S.2
Dechambre, S.3
Maldague, B.4
-
15
-
-
0036153994
-
Subsegmental pulmonary emboli: Improved detection with thin-collimation multi-detector row spiral CT
-
U.J. Schoepf, N. Holzknecht, and T.K. Helmberger Subsegmental pulmonary emboli: improved detection with thin-collimation multi-detector row spiral CT Radiology 222 2 2002 483 490 (Pubitemid 34106123)
-
(2002)
Radiology
, vol.222
, Issue.2
, pp. 483-490
-
-
Schoepf, U.J.1
Holzknecht, N.2
Helmberger, T.K.3
Crispin, A.4
Hong, C.5
Becker, C.R.6
Reiser, M.F.7
-
16
-
-
0033837007
-
Multiphasic injection method for uniform prolonged vascular enhancement at CT angiography: Pharmacokinetic analysis and experimental porcine model
-
K.T. Bae, H.Q. Tran, and J.P. Heiken Multiphasic injection method for uniform prolonged vascular enhancement at CT angiography: pharmacokinetic analysis and experimental porcine model Radiology 216 3 2000 872 880 (Pubitemid 30660868)
-
(2000)
Radiology
, vol.216
, Issue.3
, pp. 872-880
-
-
Bae, K.T.1
Tran, H.Q.2
Heiken, J.P.3
-
17
-
-
0031010385
-
Peripheral pulmonary arteries: Optimization of the spiral CT acquisition protocol
-
M. Remy-Jardin, J. Remy, D. Artaud, F. Deschildre, and A. Duhamel Peripheral pulmonary arteries: optimization of the spiral CT acquisition protocol Radiology 204 1 1997 157 163 (Pubitemid 27281725)
-
(1997)
Radiology
, vol.204
, Issue.1
, pp. 157-163
-
-
Remy-Jardin, M.1
Remy, J.2
Artaud, D.3
Deschildre, F.4
Duhamel, A.5
-
18
-
-
0036149482
-
Optimal scan delay in spiral CT for the diagnosis of acute pulmonary embolism
-
DOI 10.1097/00004728-200201000-00004
-
I.J. Hartmann, R.T. Lo, J. Bakker, W. de Monye, P.F. van Waes, and P.M. Pattynama Optimal scan delay in spiral CT for the diagnosis of acute pulmonary embolism J Comput Assist Tomogr 26 1 2002 21 25 (Pubitemid 34075841)
-
(2002)
Journal of Computer Assisted Tomography
, vol.26
, Issue.1
, pp. 21-25
-
-
Hartmann, I.J.C.1
Lo, R.T.H.2
Bakker, J.3
De Monye, W.4
Van Waes, P.F.G.M.5
Pattynama, P.M.T.6
-
19
-
-
30444433392
-
Saline chasing technique with dual-syringe injector systems for multi-detector row computed tomographic angiography: Rationale, indications, and protocols
-
DOI 10.1067/j.cpradiol.2005.10.001, PII S0363018805000617
-
M.A. Auler, T. Heagy, L. Aganovic, R. Brothers, P. Costello, and U.J. Schoepf Saline chasing technique with dual-syringe injector systems for multi-detector row computed tomographic angiography: rationale, indications, and protocols Curr Probl Diagn Radiol 35 1 2006 1 11 (Pubitemid 43071932)
-
(2006)
Current Problems in Diagnostic Radiology
, vol.35
, Issue.1
, pp. 1-11
-
-
Auler, M.A.1
Heagy, T.2
Aganovic, L.3
Brothers, R.4
Costello, P.5
Schoepf, U.J.6
-
20
-
-
35349026173
-
Management of suspected acute pulmonary embolism in the era of CT angiography: A statement from the Fleischner Society
-
DOI 10.1148/radiol.2452070397
-
M. Remy-Jardin, M. Pistolesi, and L.R. Goodman Management of suspected acute pulmonary embolism in the era of CT angiography: a statement from the Fleischner Society Radiology 245 2 2007 315 329 (Pubitemid 47612510)
-
(2007)
Radiology
, vol.245
, Issue.2
, pp. 315-329
-
-
Remy-Jardin, M.1
Pistolesi, M.2
Goodman, L.R.3
Gefter, W.B.4
Gottschalk, A.5
Mayo, J.R.6
Sostman, H.D.7
-
21
-
-
1642458217
-
CT Angiography for Diagnosis of Pulmonary Embolism: State of the Art
-
DOI 10.1148/radiol.2302021489
-
U.J. Schoepf, and P. Costello CT angiography for diagnosis of pulmonary embolism: state of the art Radiology 230 2 2004 329 337 (Pubitemid 38133787)
-
(2004)
Radiology
, vol.230
, Issue.2
, pp. 329-337
-
-
Schoepf, U.J.1
Costello, P.2
-
22
-
-
55349095807
-
Lung perfusion with dual-energy multidetector-row CT (MDCT): Feasibility for the evaluation of acute pulmonary embolism in 117 consecutive patients
-
F. Pontana, J.B. Faivre, and M. Remy-Jardin Lung perfusion with dual-energy multidetector-row CT (MDCT): feasibility for the evaluation of acute pulmonary embolism in 117 consecutive patients Acad Radiol 15 12 2008 1494 1504
-
(2008)
Acad Radiol
, vol.15
, Issue.12
, pp. 1494-1504
-
-
Pontana, F.1
Faivre, J.B.2
Remy-Jardin, M.3
-
23
-
-
33750523207
-
Utility of triple channel injection of contrast material with mixture of saline, with acquisition in the cephalic direction for arterial trees in the thorax using multislice computed tomography
-
DOI 10.1016/j.ijcard.2005.07.079, PII S016752730501137X
-
N. Funabashi, H. Sato, M. Asano, T. Nakayama, and I. Komuro Utility of triple channel injection of contrast material with mixture of saline, with acquisition in the cephalic direction for arterial trees in the thorax using multislice computed tomography Int J Cardiol 113 1 2006 97 103 (Pubitemid 44660080)
-
(2006)
International Journal of Cardiology
, vol.113
, Issue.1
, pp. 97-103
-
-
Funabashi, N.1
Sato, H.2
Asano, M.3
Nakayama, T.4
Komuro, I.5
-
24
-
-
44449151565
-
Right heart: Split-bolus injection of diluted contrast medium for visualization at coronary CT angiography
-
J.M. Kerl, J.G. Ravenel, and S.A. Nguyen Right heart: split-bolus injection of diluted contrast medium for visualization at coronary CT angiography Radiology 247 2 2008 356 364
-
(2008)
Radiology
, vol.247
, Issue.2
, pp. 356-364
-
-
Kerl, J.M.1
Ravenel, J.G.2
Nguyen, S.A.3
|