메뉴 건너뛰기




Volumn 14, Issue 4, 2004, Pages 659-664

Improvement of parenchymal and vascular enchancement using saline flush and power injection for multiple-detector-row abdominal CT

Author keywords

Abdomen; Comparative study; Contrast media; Spiral CT

Indexed keywords

NONIONIC CONTRAST MEDIUM; SODIUM CHLORIDE;

EID: 1842450677     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00330-003-2085-3     Document Type: Article
Times cited : (71)

References (21)
  • 2
    • 0027987144 scopus 로고
    • Hepatic CT enhancement. Part II. Alterations in contrast material volume and rate of injection within the same patients
    • Chambers TP, Baron RL, Lush RM (1994) Hepatic CT enhancement. Part II. Alterations in contrast material volume and rate of injection within the same patients. Radiology 193:518-522
    • (1994) Radiology , vol.193 , pp. 518-522
    • Chambers, T.P.1    Baron, R.L.2    Lush, R.M.3
  • 3
    • 0027960919 scopus 로고
    • Hepatic CT enhancement, Part I. Alterations in the volume of contrast material within the same patients
    • Chambers TP, Baron RL, Lush RM (1994) Hepatic CT enhancement, Part I. Alterations in the volume of contrast material within the same patients. Radiology 193:513-517
    • (1994) Radiology , vol.193 , pp. 513-517
    • Chambers, T.P.1    Baron, R.L.2    Lush, R.M.3
  • 4
    • 0034668332 scopus 로고    scopus 로고
    • Prediction of optimal injection protocol for tumor detection in contrast-enhanced dynamic hepatic CT using simulation of lesion-to-liver contrast difference
    • Kim S, Kim JH, Han JK, Lee KH, Min BG (2000) Prediction of optimal injection protocol for tumor detection in contrast-enhanced dynamic hepatic CT using simulation of lesion-to-liver contrast difference. Comput Med Imaging Graph 24:317-327
    • (2000) Comput. Med. Imaging Graph , vol.24 , pp. 317-327
    • Kim, S.1    Kim, J.H.2    Han, J.K.3    Lee, K.H.4    Min, B.G.5
  • 6
    • 0029878125 scopus 로고    scopus 로고
    • Patient allergies: Role in selective use of nonionic contrast material
    • Halpern JD, Hopper KD, Arredondo MG, Trautlein JJ (1996) Patient allergies: Role in selective use of nonionic contrast material. Radiology 199:359-362
    • (1996) Radiology , vol.199 , pp. 359-362
    • Halpern, J.D.1    Hopper, K.D.2    Arredondo, M.G.3    Trautlein, J.J.4
  • 7
    • 0030094692 scopus 로고    scopus 로고
    • With helical CT, is nonionic contrast a better choice than ionic contrast for rapid and large IV bolus injections?
    • Hopper KD (1996) With helical CT, is nonionic contrast a better choice than ionic contrast for rapid and large IV bolus injections? Am J Roentgenol 166:715
    • (1996) Am. J. Roentgenol. , vol.166 , pp. 715
    • Hopper, K.D.1
  • 8
    • 0028316946 scopus 로고
    • Dose requirements for a nonionic contrast agent for spiral computed tomography of the liver in rabbits
    • Bluemke DA, Fishman EK, Anderson JH (1994) Dose requirements for a nonionic contrast agent for spiral computed tomography of the liver in rabbits. Invest Radiol 29:195-200
    • (1994) Invest. Radiol. , vol.29 , pp. 195-200
    • Bluemke, D.A.1    Fishman, E.K.2    Anderson, J.H.3
  • 9
    • 0029152751 scopus 로고
    • Hepatic helical CT: Effect of reduction of iodine dose of intravenous contrast material on hepatic contrast enhancement
    • Freeny PC, Gardner JC, von Ingersleben G, Heyano S, Nghiem HV, Winter TC (1995) Hepatic helical CT: Effect of reduction of iodine dose of intravenous contrast material on hepatic contrast enhancement. Radiology 197:89-93
    • (1995) Radiology , vol.197 , pp. 89-93
    • Freeny, P.C.1    Gardner, J.C.2    von Ingersleben, G.3    Heyano, S.4    Nghiem, H.V.5    Winter, T.C.6
  • 13
    • 0343517484 scopus 로고    scopus 로고
    • Detection of focal liver lesions at biphasic spiral CT: Randomized double-blind study of the effect of iodine concentration in contrast materials
    • Hanninen EL, Vogl TJ, Felfe R, Pegios W, Balzer J, Clauss W, Felix R (2000) Detection of focal liver lesions at biphasic spiral CT: randomized double-blind study of the effect of iodine concentration in contrast materials. Radiology 216:403-409
    • (2000) Radiology , vol.216 , pp. 403-409
    • Hanninen, E.L.1    Vogl, T.J.2    Felfe, R.3    Pegios, W.4    Balzer, J.5    Clauss, W.6    Felix, R.7
  • 14
    • 0028832165 scopus 로고
    • Use of contrast material for spiral CT of the abdomen: Comparison of hepatic enhancement and vascular attenuation for three different contrast media at two different delay times
    • Herts BR, Paushter DM, Einstein DM, Zepp R, Friedman RA, Obuchowski N (1995) Use of contrast material for spiral CT of the abdomen: Comparison of hepatic enhancement and vascular attenuation for three different contrast media at two different delay times. Am J Roentgenol 164:327-331
    • (1995) Am. J. Roentgenol. , vol.164 , pp. 327-331
    • Herts, B.R.1    Paushter, D.M.2    Einstein, D.M.3    Zepp, R.4    Friedman, R.A.5    Obuchowski, N.6
  • 15
    • 0033005486 scopus 로고    scopus 로고
    • Pancreatic CT imaging: Effects of different injection rates and doses of contrast material
    • Kim T, Murakami T, Takahashi S, Okada A, Hori M, Narumi Y, Nakamura H (1999) Pancreatic CT imaging: Effects of different injection rates and doses of contrast material. Radiology 212:219-225
    • (1999) Radiology , vol.212 , pp. 219-225
    • Kim, T.1    Murakami, T.2    Takahashi, S.3    Okada, A.4    Hori, M.5    Narumi, Y.6    Nakamura, H.7
  • 16
    • 0028362884 scopus 로고
    • Contrast-enhanced spiral CT of the liver: Effect of different amounts and injection rates of contrast material on early contrast enhancement
    • Small WC, Nelson RC, Bernardino ME, Brummer LT (1994) Contrast-enhanced spiral CT of the liver: Effect of different amounts and injection rates of contrast material on early contrast enhancement. Am J Roentgenol 163:87-92
    • (1994) Am. J. Roentgenol. , vol.163 , pp. 87-92
    • Small, W.C.1    Nelson, R.C.2    Bernardino, M.E.3    Brummer, L.T.4
  • 17
    • 0033848915 scopus 로고    scopus 로고
    • Abdominal helical CT: Evaluation of optimal doses of intravenous contrast material: A prospective randomized study
    • Yamashita Y, Komohara Y, Takahashi M, Uchida M, Hayabuchi N, Shimizu T, Narabayashi I (2000) Abdominal helical CT: Evaluation of optimal doses of intravenous contrast material: A prospective randomized study. Radiology 216:718-723
    • (2000) Radiology , vol.216 , pp. 718-723
    • Yamashita, Y.1    Komohara, Y.2    Takahashi, M.3    Uchida, M.4    Hayabuchi, N.5    Shimizu, T.6    Narabayashi, I.7
  • 18
    • 0034885355 scopus 로고    scopus 로고
    • Optimization of automatic bolus tracking for timing of the arterial phase of helical liver CT
    • Sandstede JJ, Tschammler A, Beer M, Vogelsang C, Wittenberg G, Hahn D (2001) Optimization of automatic bolus tracking for timing of the arterial phase of helical liver CT. Eur Radiol 11:1396-1400
    • (2001) Eur. Radiol. , vol.11 , pp. 1396-1400
    • Sandstede, J.J.1    Tschammler, A.2    Beer, M.3    Vogelsang, C.4    Wittenberg, G.5    Hahn, D.6
  • 19
    • 0030825080 scopus 로고    scopus 로고
    • Thoracic spiral CT: Delivery of contrast material pushed with injectable saline solution in a power injector
    • Hopper KD, Mosher TJ, Kasales CJ, TenHave TR, Tully DA, Weaver JS (1997) Thoracic spiral CT: Delivery of contrast material pushed with injectable saline solution in a power injector. Radiology 205:269-271
    • (1997) Radiology , vol.205 , pp. 269-271
    • Hopper, K.D.1    Mosher, T.J.2    Kasales, C.J.3    TenHave, T.R.4    Tully, D.A.5    Weaver, J.S.6
  • 20
    • 0034112337 scopus 로고    scopus 로고
    • Reduction of contrast material dose and artifacts by a saline flush using a double power injector in helical CT of the thorax
    • Haage P, Schmitz-Rode T, Hubner D, Piroth W, Gunther RW (2000) Reduction of contrast material dose and artifacts by a saline flush using a double power injector in helical CT of the thorax. Am J Roentgenol 174:1049-1053
    • (2000) Am. J. Roentgenol. , vol.174 , pp. 1049-1053
    • Haage, P.1    Schmitz-Rode, T.2    Hubner, D.3    Piroth, W.4    Gunther, R.W.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.