메뉴 건너뛰기




Volumn 35, Issue 1, 2006, Pages 1-11

Saline chasing technique with dual-syringe injector systems for multi-detector row computed tomographic angiography: Rationale, indications, and protocols

Author keywords

[No Author keywords available]

Indexed keywords

CONTRAST MEDIUM; GADOLINIUM; IODINE; NONIONIC CONTRAST MEDIUM; SODIUM CHLORIDE;

EID: 30444433392     PISSN: 03630188     EISSN: None     Source Type: Journal    
DOI: 10.1067/j.cpradiol.2005.10.001     Document Type: Article
Times cited : (14)

References (7)
  • 1
    • 0030825080 scopus 로고    scopus 로고
    • Thoracic spiral CT: Delivery of contrast material pushed with injectable saline solution in a power injector
    • K.D. Hopper, T.J. Mosher, C.J. Kasales et al. Thoracic spiral CT: delivery of contrast material pushed with injectable saline solution in a power injector. Radiology 205 1997 269-271
    • (1997) Radiology , vol.205 , pp. 269-271
    • Hopper, K.D.1    Mosher, T.J.2    Kasales, C.J.3
  • 2
    • 1842450677 scopus 로고    scopus 로고
    • Improvement of parenchymal and vascular enhancement using saline flush and power injection for multiple-detector-row abdominal CT
    • H. Schoellnast, M. Tillich, H.A. Deutschmann, et al. Improvement of parenchymal and vascular enhancement using saline flush and power injection for multiple-detector-row abdominal CT. Eur Radiol 14 2004 659-664
    • (2004) Eur Radiol , vol.14 , pp. 659-664
    • Schoellnast, H.1    Tillich, M.2    Deutschmann, H.A.3
  • 3
    • 0034762345 scopus 로고    scopus 로고
    • Demonstration of pulmonary embolism with gadolinium-enhanced spiral CT
    • E.E. Coche, F.D. Hammer, P.P. Goffette, Demonstration of pulmonary embolism with gadolinium-enhanced spiral CT. Eur Radiol 11 2001 2306-2309
    • (2001) Eur Radiol , vol.11 , pp. 2306-2309
    • Coche, E.E.1    Hammer, F.D.2    Goffette, P.P.3
  • 4
    • 0034112337 scopus 로고    scopus 로고
    • Reduction of contrast material dose and artifacts by a saline flush using a double power injector in helical CT of the thorax
    • P. Haage, T. Schmidz-Rode, D. Hubner et al. Reduction of contrast material dose and artifacts by a saline flush using a double power injector in helical CT of the thorax. AJR 174 2000 1049-1053
    • (2000) AJR , vol.174 , pp. 1049-1053
    • Haage, P.1    Schmidz-Rode, T.2    Hubner, D.3
  • 6
    • 0242499348 scopus 로고    scopus 로고
    • Abdominal multidetector row computed tomography: Reduction of cost and contrast material dose using saline flush
    • H. Schoellnast, M. Tillich, H.A. Deutschmann et al. Abdominal multidetector row computed tomography: Reduction of cost and contrast material dose using saline flush. J Comput Assist Tomogr 27 2003 847-853
    • (2003) J Comput Assist Tomogr , vol.27 , pp. 847-853
    • Schoellnast, H.1    Tillich, M.2    Deutschmann, H.A.3
  • 7
    • 0037378558 scopus 로고    scopus 로고
    • Using a saline chaser to decrease contrast media in abdominal CT
    • P.J. Dorio, F.T. Lee, K.P. Hensler et al. Using a saline chaser to decrease contrast media in abdominal CT. AJR 180 2003 929-934
    • (2003) AJR , vol.180 , pp. 929-934
    • Dorio, P.J.1    Lee, F.T.2    Hensler, K.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.