메뉴 건너뛰기




Volumn 80, Issue 3, 2011, Pages 796-801

BLADE acquisition method improves T2-weighted MR images of the female pelvis compared with a standard fast spin-echo sequence

Author keywords

BLADE; Female pelvis; Periodically rotated overlapping parallel lines with enhanced reconstruction; PROPELLER; T2 weighted imaging

Indexed keywords

SCOPOLAMINE BUTYL BROMIDE;

EID: 80755143508     PISSN: 0720048X     EISSN: 18727727     Source Type: Journal    
DOI: 10.1016/j.ejrad.2010.08.002     Document Type: Article
Times cited : (19)

References (20)
  • 2
    • 39549098668 scopus 로고    scopus 로고
    • Do anticholinergic agents suppress uterine peristalsis and sporadic myometrial contractions at cine MR imaging?
    • A. Nakai, K. Togashi, and K. Kosaka Do anticholinergic agents suppress uterine peristalsis and sporadic myometrial contractions at cine MR imaging? Radiology 246 2 2008 489 496
    • (2008) Radiology , vol.246 , Issue.2 , pp. 489-496
    • Nakai, A.1    Togashi, K.2    Kosaka, K.3
  • 3
    • 42649084712 scopus 로고    scopus 로고
    • High-resolution T2-weighted abdominal magnetic resonance imaging using respiratory triggering: Impact of butylscopolamine on image quality
    • DOI 10.1080/02841850801894806, PII 791964830
    • M. Wagner, C. Klessen, and M. Rief High-resolution T2-weighted abdominal magnetic resonance imaging using respiratory triggering: impact of butylscopolamine on image quality Acta Radiol 49 4 2008 376 382 (Pubitemid 351598790)
    • (2008) Acta Radiologica , vol.49 , Issue.4 , pp. 376-382
    • Wagner, M.1    Klessen, C.2    Rief, M.3    Elgeti, T.4    Taupitz, M.5    Hamm, B.6    Asbach, P.7
  • 4
    • 0032754594 scopus 로고    scopus 로고
    • Motion correction with PROPELLER MRI: Application to head motion and free-breathing cardiac imaging
    • DOI 10.1002/(SICI)1522-2594(199911)42:5<963::AID-MRM17>3.0.CO;2-L
    • J.G. Pipe Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging Magn Reson Med 42 5 1999 963 969 (Pubitemid 29521487)
    • (1999) Magnetic Resonance in Medicine , vol.42 , Issue.5 , pp. 963-969
    • Pipe, J.G.1
  • 5
    • 46649083409 scopus 로고    scopus 로고
    • Contrast-enhanced T1-weighted Fluid-attenuated Inversion-recovery BLADE Magnetic Resonance Imaging of the Brain. An Alternative to Spin-echo Technique for Detection of Brain Lesions in the Unsedated Pediatric Patient?
    • DOI 10.1016/j.acra.2008.03.009, PII S1076633208001827
    • S. Alibek, B. Adamietz, and A. Cavallaro Contrast-enhanced T1-weighted fluid-attenuated inversion-recovery BLADE magnetic resonance imaging of the brain: an alternative to spin-echo technique for detection of brain lesions in the unsedated pediatric patient? Acad Radiol 15 8 2008 986 995 (Pubitemid 351938741)
    • (2008) Academic Radiology , vol.15 , Issue.8 , pp. 986-995
    • Alibek, S.1    Adamietz, B.2    Cavallaro, A.3    Stemmer, A.4    Anders, K.5    Kramer, M.6    Bautz, W.7    Staatz, G.8
  • 6
    • 75749141605 scopus 로고    scopus 로고
    • T2-weighted MRI of the upper abdomen: Comparison of four fat-suppressed T2-weighted sequences including PROPELLER (BLADE) technique
    • S. Bayramoglu, O. Kilickesmez, and T. Cimilli T2-weighted MRI of the upper abdomen: comparison of four fat-suppressed T2-weighted sequences including PROPELLER (BLADE) technique Acad Radiol 17 3 2010 368 374
    • (2010) Acad Radiol , vol.17 , Issue.3 , pp. 368-374
    • Bayramoglu, S.1    Kilickesmez, O.2    Cimilli, T.3
  • 7
    • 4344667528 scopus 로고    scopus 로고
    • High-resolution MR-imaging of the liver with T2-weighted sequences using integrated parallel imaging: Comparison of prospective motion correction and respiratory triggering
    • DOI 10.1002/jmri.20127
    • C.J. Zech, K.A. Herrmann, and A. Huber High-resolution MR-imaging of the liver with T2-weighted sequences using integrated parallel imaging: comparison of prospective motion correction and respiratory triggering J Magn Reson Imaging 20 3 2004 443 450 (Pubitemid 39121943)
    • (2004) Journal of Magnetic Resonance Imaging , vol.20 , Issue.3 , pp. 443-450
    • Zech, C.J.1    Herrmann, K.A.2    Huber, A.3    Dietrich, O.4    Stemmer, A.5    Herzog, P.6    Reiser, M.F.7    Schoenberg, S.O.8
  • 8
    • 0021166164 scopus 로고
    • Cranio-caudal movements of the liver, pancreas and kidneys in respiration
    • I. Suramo, M. Paivansalo, and V. Myllyla Cranio-caudal movements of the liver, pancreas and kidneys in respiration Acta Radiol Diagn (Stockh) 25 2 1984 129 131 (Pubitemid 14108143)
    • (1984) Acta Radiologica - Series Diagnosis , vol.25 , Issue.2 , pp. 129-131
    • Suramo, I.1    Paivansalo, M.2    Myllyla, V.3
  • 9
    • 0032871479 scopus 로고    scopus 로고
    • Impact of the filling status of the bladder and rectum on their integral dose distribution and the movement of the uterus in the treatment planning of gynaecological cancer
    • DOI 10.1016/S0167-8140(99)00068-7, PII S0167814099000687
    • A. Buchali, S. Koswig, and S. Dinges Impact of the filling status of the bladder and rectum on their integral dose distribution and the movement of the uterus in the treatment planning of gynaecological cancer Radiother Oncol 52 1 1999 29 34 (Pubitemid 29461093)
    • (1999) Radiotherapy and Oncology , vol.52 , Issue.1 , pp. 29-34
    • Buchali, A.1    Koswig, S.2    Dinges, S.3    Rosenthal, P.4    Salk, J.5    Lackner, G.6    Bohmer, D.7    Schlenger, L.8    Budach, V.9
  • 10
    • 0037742326 scopus 로고    scopus 로고
    • Effect of subcutaneous butylscopolamine administration in the reduction of peristaltic artifacts in 1.5-T MR fast abdominal examinations
    • R. Dosda, L. Marti-Bonmati, C.L. Ronchera-Oms, E. Molla, and E. Arana Effect of subcutaneous butylscopolamine administration in the reduction of peristaltic artifacts in 1.5-T MR fast abdominal examinations Eur Radiol 13 2 2003 294 298 (Pubitemid 36798606)
    • (2003) European Radiology , vol.13 , Issue.2 , pp. 294-298
    • Dosda, R.1    Marti-Bonmati, L.2    Ronchera-Oms, C.L.3    Molla, E.4    Arana, E.5
  • 11
    • 0022610694 scopus 로고
    • Pelvis imaging with MR: Technique for improvement
    • M.L. Winkler, and H. Hricak Pelvis imaging with MR: technique for improvement Radiology 158 3 1986 848 849 (Pubitemid 16101289)
    • (1986) Radiology , vol.158 , Issue.3 , pp. 848-849
    • Winkler, M.L.1    Hricak, H.2
  • 12
    • 44749085515 scopus 로고    scopus 로고
    • Precautions to be taken by radiologists and radiographers when prescribing hyoscine-N-butylbromide
    • R. Dyde, A.H. Chapman, R. Gale, A. Mackintosh, and D.J. Tolan Precautions to be taken by radiologists and radiographers when prescribing hyoscine-N-butylbromide Clin Radiol 63 7 2008 739 743
    • (2008) Clin Radiol , vol.63 , Issue.7 , pp. 739-743
    • Dyde, R.1    Chapman, A.H.2    Gale, R.3    MacKintosh, A.4    Tolan, D.J.5
  • 14
    • 32544450791 scopus 로고    scopus 로고
    • Turboprop: Improved PROPELLER imaging
    • DOI 10.1002/mrm.20768
    • J.G. Pipe, and N. Zwart Turboprop: improved PROPELLER imaging Magn Reson Med 55 2 2006 380 385 (Pubitemid 43238107)
    • (2006) Magnetic Resonance in Medicine , vol.55 , Issue.2 , pp. 380-385
    • Pipe, J.G.1    Zwart, N.2
  • 15
    • 0038517259 scopus 로고    scopus 로고
    • Brain imaging in the unsedated pediatric patient: Comparison of periodically rotated overlapping parallel lines with enhanced reconstruction and single-shot fast spin-echo sequences
    • K.P. Forbes, J.G. Pipe, J.P. Karis, V. Farthing, and J.E. Heiserman Brain imaging in the unsedated pediatric patient: comparison of periodically rotated overlapping parallel lines with enhanced reconstruction and single-shot fast spin-echo sequences Am J Neuroradiol 24 5 2003 794 798 (Pubitemid 36617403)
    • (2003) American Journal of Neuroradiology , vol.24 , Issue.5 , pp. 794-798
    • Forbes, K.P.1    Pipe, J.G.2    Karis, J.P.3    Farthing, V.4    Heiserman, J.E.5
  • 17
    • 41349097514 scopus 로고    scopus 로고
    • The utility of diffusion-weighted MR imaging for differentiating uterine sarcomas from benign leiomyomas
    • DOI 10.1007/s00330-007-0787-7
    • K. Tamai, T. Koyama, and T. Saga The utility of diffusion-weighted MR imaging for differentiating uterine sarcomas from benign leiomyomas Eur Radiol 18 4 2008 723 730 (Pubitemid 351447778)
    • (2008) European Radiology , vol.18 , Issue.4 , pp. 723-730
    • Tamai, K.1    Koyama, T.2    Saga, T.3    Morisawa, N.4    Fujimoto, K.5    Mikami, Y.6    Togashi, K.7
  • 19
    • 0034267449 scopus 로고    scopus 로고
    • Imaging evaluation of ovarian masses
    • Y.Y. Jeong, E.K. Outwater, and H.K. Kang Imaging evaluation of ovarian masses Radiographics 20 5 2000 1445 1470
    • (2000) Radiographics , vol.20 , Issue.5 , pp. 1445-1470
    • Jeong, Y.Y.1    Outwater, E.K.2    Kang, H.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.