메뉴 건너뛰기




Volumn 17, Issue 3, 2010, Pages 368-374

T2-weighted MRI of the Upper Abdomen:. Comparison of Four Fat-Suppressed T2-weighted Sequences Including PROPELLER (BLADE) Technique

Author keywords

BLADE; fat suppression; liver; MRI

Indexed keywords

ABDOMINAL RADIOGRAPHY; ADULT; AGED; ARTICLE; CLINICAL ARTICLE; FEMALE; GALLBLADDER; HUMAN; IMAGE QUALITY; LIVER; LIVER HEMANGIOMA; LIVER INJURY; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PANCREAS; PRIORITY JOURNAL; QUALITATIVE ANALYSIS; QUANTITATIVE ANALYSIS; SPLEEN;

EID: 75749141605     PISSN: 10766332     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.acra.2009.10.015     Document Type: Article
Times cited : (42)

References (31)
  • 1
    • 0031001798 scopus 로고    scopus 로고
    • Liver T2-weighted MR imaging: comparison of fast and conventional half-Fourier single-shot turbo spin-echo, breath-hold turbo spin-echo, and respiratory-triggered turbo spin-echo sequences
    • Tang Y., Yamashita Y., Namimoto T., et al. Liver T2-weighted MR imaging: comparison of fast and conventional half-Fourier single-shot turbo spin-echo, breath-hold turbo spin-echo, and respiratory-triggered turbo spin-echo sequences. Radiology 203 (1997) 766-772
    • (1997) Radiology , vol.203 , pp. 766-772
    • Tang, Y.1    Yamashita, Y.2    Namimoto, T.3
  • 2
    • 0030820223 scopus 로고    scopus 로고
    • Hepatic lesions: discrimination of nonsolid, benign lesions from solid, malignant lesions with heavily T2-weighted fast spin-echo MR imaging
    • Ito K., Mitchell D.G., Outwater E.K., et al. Hepatic lesions: discrimination of nonsolid, benign lesions from solid, malignant lesions with heavily T2-weighted fast spin-echo MR imaging. Radiology 204 (1997) 729-737
    • (1997) Radiology , vol.204 , pp. 729-737
    • Ito, K.1    Mitchell, D.G.2    Outwater, E.K.3
  • 3
    • 0033836929 scopus 로고    scopus 로고
    • T-weighted MR imaging for focal hepatic lesion detection: supplementary value of breath-hold imaging with half-Fourier single-shot fast spin-echo and multishot spin-echo echoplanar sequences
    • Matsuo M., Kanematsu M., Murakami T., et al. T-weighted MR imaging for focal hepatic lesion detection: supplementary value of breath-hold imaging with half-Fourier single-shot fast spin-echo and multishot spin-echo echoplanar sequences. J Magn Reson Imaging 12 (2000) 444-452
    • (2000) J Magn Reson Imaging , vol.12 , pp. 444-452
    • Matsuo, M.1    Kanematsu, M.2    Murakami, T.3
  • 4
    • 0033934382 scopus 로고    scopus 로고
    • A prospective assessment of breath-hold fast spin echo and inversion recovery fast spin echo techniques for detection and characterization of focal hepatic lesions
    • Pawluk R.S., Borrello J.A., Brown J.J., et al. A prospective assessment of breath-hold fast spin echo and inversion recovery fast spin echo techniques for detection and characterization of focal hepatic lesions. Magn Reson Imaging 18 (2000) 543-551
    • (2000) Magn Reson Imaging , vol.18 , pp. 543-551
    • Pawluk, R.S.1    Borrello, J.A.2    Brown, J.J.3
  • 5
    • 0034096050 scopus 로고    scopus 로고
    • Single breath-hold T2-weighted MR imaging of the liver: value of single-shot fast spin-echo and multishot spin-echo echoplanar imaging
    • Hori M., Murakami T., Kim T., et al. Single breath-hold T2-weighted MR imaging of the liver: value of single-shot fast spin-echo and multishot spin-echo echoplanar imaging. AJR Am J Roentgenol 174 (2000) 1423-1431
    • (2000) AJR Am J Roentgenol , vol.174 , pp. 1423-1431
    • Hori, M.1    Murakami, T.2    Kim, T.3
  • 6
    • 0036113978 scopus 로고    scopus 로고
    • Liver: T2-weighted MR imaging with breath-hold fast-recovery optimized fast spin-echo compared with breath-hold half-Fourier and non-breath-hold respiratory-triggered fast spin-echo pulse sequences
    • Augui J., Vignaux O., Argaud C., et al. Liver: T2-weighted MR imaging with breath-hold fast-recovery optimized fast spin-echo compared with breath-hold half-Fourier and non-breath-hold respiratory-triggered fast spin-echo pulse sequences. Radiology 223 (2002) 853-859
    • (2002) Radiology , vol.223 , pp. 853-859
    • Augui, J.1    Vignaux, O.2    Argaud, C.3
  • 7
    • 33645666657 scopus 로고    scopus 로고
    • Focal liver lesions: breathhold gradient and spin-echo T2-weighted imaging for detection and characterization
    • Yoshikawa T., Mitchell D.G., Hirota S., et al. Focal liver lesions: breathhold gradient and spin-echo T2-weighted imaging for detection and characterization. J Magn Reson Imaging 23 (2006) 520-528
    • (2006) J Magn Reson Imaging , vol.23 , pp. 520-528
    • Yoshikawa, T.1    Mitchell, D.G.2    Hirota, S.3
  • 9
    • 0028814643 scopus 로고
    • Breath-hold fast spin echo MR imaging of the liver: a technique for high-quality T2-weighted images
    • Reinig J.W. Breath-hold fast spin echo MR imaging of the liver: a technique for high-quality T2-weighted images. Radiology 194 (1995) 303-304
    • (1995) Radiology , vol.194 , pp. 303-304
    • Reinig, J.W.1
  • 10
    • 0029953063 scopus 로고    scopus 로고
    • Liver masses: replacement of conventional T2-weighted spin-echo MR imaging with breath-hold MR imaging
    • Gaa J., Hatabu H., Jenkins R.L., et al. Liver masses: replacement of conventional T2-weighted spin-echo MR imaging with breath-hold MR imaging. Radiology 200 (1996) 459-464
    • (1996) Radiology , vol.200 , pp. 459-464
    • Gaa, J.1    Hatabu, H.2    Jenkins, R.L.3
  • 11
    • 0344474664 scopus 로고    scopus 로고
    • Comparison of multishot turbo spin echo and HASTE sequences for T2-weighted MRI of liver lesions
    • Yu J.S., Kim K.W., Kim Y.H., et al. Comparison of multishot turbo spin echo and HASTE sequences for T2-weighted MRI of liver lesions. J Magn Reson Imaging 8 (1998) 1079-1084
    • (1998) J Magn Reson Imaging , vol.8 , pp. 1079-1084
    • Yu, J.S.1    Kim, K.W.2    Kim, Y.H.3
  • 12
    • 0034904522 scopus 로고    scopus 로고
    • Improving the detectability of focal liver lesions on T2-weighted MR images: ultrafast breath-hold or respiratory-triggered thin section MRI?
    • Pauleit D., Textor J., Bachmann R., et al. Improving the detectability of focal liver lesions on T2-weighted MR images: ultrafast breath-hold or respiratory-triggered thin section MRI?. J Magn Reson Imaging 14 (2001) 128-133
    • (2001) J Magn Reson Imaging , vol.14 , pp. 128-133
    • Pauleit, D.1    Textor, J.2    Bachmann, R.3
  • 13
    • 0033045332 scopus 로고    scopus 로고
    • Focal hepatic lesion detection: comparison of four fat-suppressed T2-weighted MR imaging pulse sequences
    • Kanematsu M., Hoshi H., Itoh K., et al. Focal hepatic lesion detection: comparison of four fat-suppressed T2-weighted MR imaging pulse sequences. Radiology 211 (1999) 363-371
    • (1999) Radiology , vol.211 , pp. 363-371
    • Kanematsu, M.1    Hoshi, H.2    Itoh, K.3
  • 14
    • 4344667528 scopus 로고    scopus 로고
    • High-resolution MR-imaging of the liver with T2-weighted sequences using integrated parallel imaging: comparison of prospective motion correction and respiratory triggering
    • Zech C.J., Herrmann K.A., Huber A., et al. High-resolution MR-imaging of the liver with T2-weighted sequences using integrated parallel imaging: comparison of prospective motion correction and respiratory triggering. J Magn Reson Imaging 20 (2004) 443-450
    • (2004) J Magn Reson Imaging , vol.20 , pp. 443-450
    • Zech, C.J.1    Herrmann, K.A.2    Huber, A.3
  • 15
    • 34547897640 scopus 로고    scopus 로고
    • Image quality and focal lesion detection on T2-weighted MR imaging of the liver: comparison of two high-resolution free-breathing imaging techniques with two breath-hold imaging techniques
    • Lee S.S., Byun J.H., Hong H.S., et al. Image quality and focal lesion detection on T2-weighted MR imaging of the liver: comparison of two high-resolution free-breathing imaging techniques with two breath-hold imaging techniques. J Magn Reson Imaging 26 (2007) 323-330
    • (2007) J Magn Reson Imaging , vol.26 , pp. 323-330
    • Lee, S.S.1    Byun, J.H.2    Hong, H.S.3
  • 16
    • 17844396526 scopus 로고    scopus 로고
    • Magnetic resonance imaging of the upper abdomen using a free-breathing T2-weighted turbo spin echo sequence with navigator triggered prospective acquisition correction
    • Klessen C., Asbach P., Kroencke T.J., et al. Magnetic resonance imaging of the upper abdomen using a free-breathing T2-weighted turbo spin echo sequence with navigator triggered prospective acquisition correction. J Magn Reson Imaging 21 (2005) 576-582
    • (2005) J Magn Reson Imaging , vol.21 , pp. 576-582
    • Klessen, C.1    Asbach, P.2    Kroencke, T.J.3
  • 17
    • 0034805440 scopus 로고    scopus 로고
    • Fat-suppressed T2-weighted MRI of the liver: comparison of respiratory-triggered fast spin-echo, breath-hold single-shot fast spin-echo, and breath-hold fast-recovery fast spin-echo sequences
    • Katayama M., Masui T., Kobayashi S., et al. Fat-suppressed T2-weighted MRI of the liver: comparison of respiratory-triggered fast spin-echo, breath-hold single-shot fast spin-echo, and breath-hold fast-recovery fast spin-echo sequences. J Magn Reson Imaging 14 (2001) 439-449
    • (2001) J Magn Reson Imaging , vol.14 , pp. 439-449
    • Katayama, M.1    Masui, T.2    Kobayashi, S.3
  • 18
    • 16244383192 scopus 로고    scopus 로고
    • Utility of breath-hold fast-recovery fast spin-echo T2 versus respiratory-triggered fast spin-echo T2 in clinical hepatic imaging
    • Huang J., Raman S.S., Vuong N., et al. Utility of breath-hold fast-recovery fast spin-echo T2 versus respiratory-triggered fast spin-echo T2 in clinical hepatic imaging. AJR Am J Roentgenol 184 (2005) 842-846
    • (2005) AJR Am J Roentgenol , vol.184 , pp. 842-846
    • Huang, J.1    Raman, S.S.2    Vuong, N.3
  • 19
    • 33747036192 scopus 로고    scopus 로고
    • Evaluation of focal liver lesions: fast-recovery fast spin-echo T2-weighted MR imaging
    • Aki{dotless}n O., Schwartz L.H., Webler A., et al. Evaluation of focal liver lesions: fast-recovery fast spin-echo T2-weighted MR imaging. Clin Imaging 30 (2006) 322-325
    • (2006) Clin Imaging , vol.30 , pp. 322-325
    • Akin, O.1    Schwartz, L.H.2    Webler, A.3
  • 20
    • 0034868687 scopus 로고    scopus 로고
    • PROPELLER MRI: clinical testing of a novel technique for quantification and compensation of head motion
    • Forbes K.P., Pipe J.G., Bird C.R., et al. PROPELLER MRI: clinical testing of a novel technique for quantification and compensation of head motion. J Magn Reson Imaging 14 (2001) 215-222
    • (2001) J Magn Reson Imaging , vol.14 , pp. 215-222
    • Forbes, K.P.1    Pipe, J.G.2    Bird, C.R.3
  • 21
    • 0038517259 scopus 로고    scopus 로고
    • Brain imaging in the unsedated pediatric patient: comparison of periodically rotated overlapping parallel lines with enhanced reconstruction and single-shot fast spin-echo sequences
    • Forbes K.P., Pipe J.G., Karis J.P., et al. Brain imaging in the unsedated pediatric patient: comparison of periodically rotated overlapping parallel lines with enhanced reconstruction and single-shot fast spin-echo sequences. AJNR Am J Neuroradiol 24 (2003) 794-798
    • (2003) AJNR Am J Neuroradiol , vol.24 , pp. 794-798
    • Forbes, K.P.1    Pipe, J.G.2    Karis, J.P.3
  • 22
    • 33747820447 scopus 로고    scopus 로고
    • Brain magnetic resonance imaging at 3 Tesla using BLADE compared with standard rectilinear data sampling
    • Wintersperger B.J., Runge V.M., Biswas J., et al. Brain magnetic resonance imaging at 3 Tesla using BLADE compared with standard rectilinear data sampling. Invest Radiol 41 (2006) 586-592
    • (2006) Invest Radiol , vol.41 , pp. 586-592
    • Wintersperger, B.J.1    Runge, V.M.2    Biswas, J.3
  • 23
    • 46649083409 scopus 로고    scopus 로고
    • Contrast-enhanced T1-weighted fluid-attenuated inversion-recovery BLADE magnetic resonance imaging of the brain: an alternative to spin-echo technique for detection of brain lesions in the unsedated pediatric patient?
    • Alibek S., Adamietz B., Cavallaro A., et al. Contrast-enhanced T1-weighted fluid-attenuated inversion-recovery BLADE magnetic resonance imaging of the brain: an alternative to spin-echo technique for detection of brain lesions in the unsedated pediatric patient?. Acad Radiol 15 (2008) 986-995
    • (2008) Acad Radiol , vol.15 , pp. 986-995
    • Alibek, S.1    Adamietz, B.2    Cavallaro, A.3
  • 24
    • 33646712315 scopus 로고    scopus 로고
    • Evaluation of super paramagnetic iron oxide-enhanced diffusion-weighted PROPELLER T2-fast spin echo magnetic resonance imaging
    • Kiryu S., Watanabe M., Kabasawa H., et al. Evaluation of super paramagnetic iron oxide-enhanced diffusion-weighted PROPELLER T2-fast spin echo magnetic resonance imaging. J Comput Assist Tomogr 30 (2006) 197-200
    • (2006) J Comput Assist Tomogr , vol.30 , pp. 197-200
    • Kiryu, S.1    Watanabe, M.2    Kabasawa, H.3
  • 25
    • 53249155042 scopus 로고    scopus 로고
    • MRI artifact reduction and quality improvement in the upper abdomen with PROPELLER and Prospective Acquisition Correction (PACE) technique
    • Hirokawa Y., Isoda H., Maetani Y.S., et al. MRI artifact reduction and quality improvement in the upper abdomen with PROPELLER and Prospective Acquisition Correction (PACE) technique. AJR Am J Roentgenol 191 (2008) 1154-1158
    • (2008) AJR Am J Roentgenol , vol.191 , pp. 1154-1158
    • Hirokawa, Y.1    Isoda, H.2    Maetani, Y.S.3
  • 27
    • 0031021888 scopus 로고    scopus 로고
    • Motion suppression in MR imaging of the liver: comparison of respiratory-triggered and non-triggered fast spin-echo sequences
    • Low R.N., Alzate G.D., and Schimakawa A. Motion suppression in MR imaging of the liver: comparison of respiratory-triggered and non-triggered fast spin-echo sequences. AJR Am J Roentgenol 168 (1997) 225-231
    • (1997) AJR Am J Roentgenol , vol.168 , pp. 225-231
    • Low, R.N.1    Alzate, G.D.2    Schimakawa, A.3
  • 28
    • 0032754594 scopus 로고    scopus 로고
    • Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging
    • Pipe J.G. Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging. Magn Reson Med 42 (1999) 963-969
    • (1999) Magn Reson Med , vol.42 , pp. 963-969
    • Pipe, J.G.1
  • 29
    • 53549091578 scopus 로고    scopus 로고
    • Evaluation of motion correction effect and image quality with the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) (BLADE) and parallel imaging acquisition technique in the upper abdomen
    • Hirokawa Y., Isoda H., Maetani Y.S., et al. Evaluation of motion correction effect and image quality with the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) (BLADE) and parallel imaging acquisition technique in the upper abdomen. J Magn Reson Imaging 28 (2008) 957-962
    • (2008) J Magn Reson Imaging , vol.28 , pp. 957-962
    • Hirokawa, Y.1    Isoda, H.2    Maetani, Y.S.3
  • 30
    • 0031401086 scopus 로고    scopus 로고
    • Phased array breath-hold versus non-breath-hold MR imaging of focal liver lesions: a prospective comparative study
    • Yamashita Y., Yamamato H., Namimoto T., et al. Phased array breath-hold versus non-breath-hold MR imaging of focal liver lesions: a prospective comparative study. J Magn Reson Imaging 7 (1997) 292-297
    • (1997) J Magn Reson Imaging , vol.7 , pp. 292-297
    • Yamashita, Y.1    Yamamato, H.2    Namimoto, T.3
  • 31
    • 66149086161 scopus 로고    scopus 로고
    • Hepatic lesions: improved image quality and detection with the periodically rotated overlapping parallel lines with enhanced reconstruction technique-evaluation of SPIO-enhanced T2-weighted MR images
    • Hirokawa Y., Isoda H., Maetani Y.S., et al. Hepatic lesions: improved image quality and detection with the periodically rotated overlapping parallel lines with enhanced reconstruction technique-evaluation of SPIO-enhanced T2-weighted MR images. Radiology 251 (2009) 388-397
    • (2009) Radiology , vol.251 , pp. 388-397
    • Hirokawa, Y.1    Isoda, H.2    Maetani, Y.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.