메뉴 건너뛰기




Volumn 41, Issue 7, 2006, Pages 586-592

Brain magnetic resonance imaging at 3 tesla using BLADE compared with standard rectilinear data sampling

Author keywords

3 T MRI; Brain; Magnetic resonance; Neuroradiology; PROPELLER

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFACT; BRAIN; CONTROLLED STUDY; FEMALE; HUMAN; IMAGE QUALITY; INFORMATION PROCESSING; INFORMED CONSENT; KAPPA STATISTICS; MALE; NEUROLOGY; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; PROSPECTIVE STUDY; STATISTICAL SIGNIFICANCE; TECHNIQUE;

EID: 33747820447     PISSN: 00209996     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.rli.0000223742.35655.24     Document Type: Article
Times cited : (67)

References (22)
  • 1
    • 0030935109 scopus 로고    scopus 로고
    • Adult claustrophobia, anxiety and sedation in MRI
    • Murphy KJ, Brunberg JA. Adult claustrophobia, anxiety and sedation in MRI. Magn Reson Imaging. 1997;15:51-54.
    • (1997) Magn Reson Imaging , vol.15 , pp. 51-54
    • Murphy, K.J.1    Brunberg, J.A.2
  • 2
    • 0027093023 scopus 로고
    • Projection reconstruction techniques for reduction of motion effects in MRI
    • Glover GH, Pauly JM. Projection reconstruction techniques for reduction of motion effects in MRI. Magn Reson Med. 1992;28:275-289.
    • (1992) Magn Reson Med , vol.28 , pp. 275-289
    • Glover, G.H.1    Pauly, J.M.2
  • 3
    • 0024453449 scopus 로고
    • Adaptive technique for high-definition MR imaging of moving structures
    • Ehman RL, Felmlee JP. Adaptive technique for high-definition MR imaging of moving structures. Radiology. 1989;173:255-263.
    • (1989) Radiology , vol.173 , pp. 255-263
    • Ehman, R.L.1    Felmlee, J.P.2
  • 4
    • 0029123801 scopus 로고
    • The diminishing variance algorithm for real-time reduction of motion artifacts in MRI
    • Sachs TS, Meyer CH, Irarrazabal P, et al. The diminishing variance algorithm for real-time reduction of motion artifacts in MRI. Magn Reson Med. 1995;34:412-422.
    • (1995) Magn Reson Med , vol.34 , pp. 412-422
    • Sachs, T.S.1    Meyer, C.H.2    Irarrazabal, P.3
  • 5
    • 0031003249 scopus 로고    scopus 로고
    • Reduction of motion artifacts in cine MRI using variable-density spiral trajectories
    • Liao JR, Pauly JM, Brosnan TJ, et al. Reduction of motion artifacts in cine MRI using variable-density spiral trajectories. Magn Reson Med. 1997;37:569-575.
    • (1997) Magn Reson Med , vol.37 , pp. 569-575
    • Liao, J.R.1    Pauly, J.M.2    Brosnan, T.J.3
  • 6
    • 14744282090 scopus 로고    scopus 로고
    • k-space undersampling in PROPELLER imaging
    • Arfanakis K, Tamhane AA, Pipe JG, et al. k-space undersampling in PROPELLER imaging. Magn Reson Med. 2005;53:675-683.
    • (2005) Magn Reson Med , vol.53 , pp. 675-683
    • Arfanakis, K.1    Tamhane, A.A.2    Pipe, J.G.3
  • 7
    • 0032754594 scopus 로고    scopus 로고
    • Motion correction with PROPELLER MRI: Application to head motion and free-breathing cardiac imaging
    • Pipe JG. Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging. Magn Reson Med. 1999;42:963-969.
    • (1999) Magn Reson Med , vol.42 , pp. 963-969
    • Pipe, J.G.1
  • 8
    • 0038517259 scopus 로고    scopus 로고
    • Brain imaging in the unsedated pediatric patient: Comparison of periodically rotated overlapping parallel lines with enhanced reconstruction and single-shot fast spin-echo sequences
    • Forbes KP, Pipe JG, Karis JP, et al. Brain imaging in the unsedated pediatric patient: comparison of periodically rotated overlapping parallel lines with enhanced reconstruction and single-shot fast spin-echo sequences. AJNR Am J Neuroradiol. 2003;24:794-798.
    • (2003) AJNR Am J Neuroradiol , vol.24 , pp. 794-798
    • Forbes, K.P.1    Pipe, J.G.2    Karis, J.P.3
  • 9
    • 0036829562 scopus 로고    scopus 로고
    • Improved image quality and detection of acute cerebral infarction with PROPELLER diffusion-weighted MR imaging
    • Forbes KP, Pipe JG, Karis JP, et al. Improved image quality and detection of acute cerebral infarction with PROPELLER diffusion-weighted MR imaging. Radiology. 2002;225:551-555.
    • (2002) Radiology , vol.225 , pp. 551-555
    • Forbes, K.P.1    Pipe, J.G.2    Karis, J.P.3
  • 10
    • 33646382132 scopus 로고    scopus 로고
    • T1-weighted imaging of the brain at 3 tesla using a 2-dimensional spoiled gradient echo technique
    • Runge VM, Patel MC, Baumann SS, et al. T1-weighted imaging of the brain at 3 tesla using a 2-dimensional spoiled gradient echo technique. Invest Radiol. 2006;41:68-75.
    • (2006) Invest Radiol , vol.41 , pp. 68-75
    • Runge, V.M.1    Patel, M.C.2    Baumann, S.S.3
  • 12
    • 0038236731 scopus 로고    scopus 로고
    • Magnetic resonance imaging at 3. 0 Tesla: Challenges and advantages in clinical neurological imaging
    • Frayne R, Goodyear BG, Dickhoff P, et al. Magnetic resonance imaging at 3. 0 Tesla: challenges and advantages in clinical neurological imaging. Invest Radiol. 2003;38:385-402.
    • (2003) Invest Radiol , vol.38 , pp. 385-402
    • Frayne, R.1    Goodyear, B.G.2    Dickhoff, P.3
  • 13
    • 33745931657 scopus 로고    scopus 로고
    • Contrast-enhanced, high-resolution, susceptibility-weighted magnetic resonance imaging of the brain: Dose-dependent optimization at 3 Tesla and 1.5 Tesla in healthy volunteers
    • Noebauer-Huhmann IM, Pinker K, Barth M, et al. Contrast-enhanced, high-resolution, susceptibility-weighted magnetic resonance imaging of the brain: dose-dependent optimization at 3 Tesla and 1.5 Tesla in healthy volunteers. Invest Radiol. 2006;41:249-255.
    • (2006) Invest Radiol , vol.41 , pp. 249-255
    • Noebauer-Huhmann, I.M.1    Pinker, K.2    Barth, M.3
  • 14
    • 0021235596 scopus 로고
    • The effect of motion on two-dimensional Fourier transformation magnetic resonance images
    • Schultz CL, Alfidi RJ, Nelson AD, et al. The effect of motion on two-dimensional Fourier transformation magnetic resonance images. Radiology. 1984;152:117-121.
    • (1984) Radiology , vol.152 , pp. 117-121
    • Schultz, C.L.1    Alfidi, R.J.2    Nelson, A.D.3
  • 15
    • 0022472314 scopus 로고
    • Influence of physiologic motion on the appearance of tissue in MR images
    • Ehman RL, McNamara MT, Brasch RC, et al. Influence of physiologic motion on the appearance of tissue in MR images. Radiology. 1986;159:777-782.
    • (1986) Radiology , vol.159 , pp. 777-782
    • Ehman, R.L.1    McNamara, M.T.2    Brasch, R.C.3
  • 16
    • 0034868687 scopus 로고    scopus 로고
    • PROPELLER MRI: Clinical testing of a novel technique for quantification and compensation of head motion
    • Forbes KP, Pipe JG, Bird CR, et al. PROPELLER MRI: clinical testing of a novel technique for quantification and compensation of head motion. J Magn Reson Imaging. 2001;14:215-222.
    • (2001) J Magn Reson Imaging , vol.14 , pp. 215-222
    • Forbes, K.P.1    Pipe, J.G.2    Bird, C.R.3
  • 17
    • 0036135369 scopus 로고    scopus 로고
    • Multishot diffusion-weighted FSE using PROPELLER MRI
    • Pipe JG, Farthing VG, Forbes KP. Multishot diffusion-weighted FSE using PROPELLER MRI. Magn Reson Med. 2002;47:42-52.
    • (2002) Magn Reson Med , vol.47 , pp. 42-52
    • Pipe, J.G.1    Farthing, V.G.2    Forbes, K.P.3
  • 18
    • 28044451074 scopus 로고    scopus 로고
    • Brain tumor enhancement in magnetic resonance imaging: Comparison of signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) at 1.5 versus 3 Tesla
    • Biswas J, Nelson CB, Runge VM, et al. Brain tumor enhancement in magnetic resonance imaging: comparison of signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) at 1.5 versus 3 Tesla. Invest Radiol. 2005;40:792-797.
    • (2005) Invest Radiol , vol.40 , pp. 792-797
    • Biswas, J.1    Nelson, C.B.2    Runge, V.M.3
  • 19
    • 33745893815 scopus 로고    scopus 로고
    • The efficacy of gadobenate dimeglumine (Gd-BOPTA) at 3 Tesla in brain magnetic resonance imaging: Comparison to 1.5 Tesla and a standard gadolinium chelate using a rat brain tumor model
    • Runge VM, Biswas J, Wintersperger BJ, et al. The efficacy of gadobenate dimeglumine (Gd-BOPTA) at 3 Tesla in brain magnetic resonance imaging: comparison to 1.5 Tesla and a standard gadolinium chelate using a rat brain tumor model. Invest Radiol. 2006;41:244-248.
    • (2006) Invest Radiol , vol.41 , pp. 244-248
    • Runge, V.M.1    Biswas, J.2    Wintersperger, B.J.3
  • 20
  • 21
    • 33747821299 scopus 로고    scopus 로고
    • ASSET enabled turboprop: An improved PROPELLER sequence for motion-corrected T2 imaging
    • Miami Beach, FL
    • Karis JP, Pipe JG. ASSET enabled turboprop: an improved PROPELLER sequence for motion-corrected T2 imaging. In: Proceedings of the 13th Annual Meeting of ISMRM, Miami Beach, FL, 2005;2235:
    • (2005) Proceedings of the 13th Annual Meeting of ISMRM , vol.2235
    • Karis, J.P.1    Pipe, J.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.