메뉴 건너뛰기




Volumn 35, Issue 11, 2011, Pages 1655-1661

The clinical benefit of medial support screws in locking plating of proximal humerus fractures: A prospective randomized study

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; BONE DENSITY; BONE PLATE; BONE SCREW; CONTROLLED STUDY; FEMALE; FOLLOW UP; FRACTURE FIXATION; FRACTURE HEALING; FRACTURE REDUCTION; HUMAN; HUMERUS FRACTURE; INTERLOCKING NAIL; JOINT FUNCTION; MAJOR CLINICAL STUDY; MALE; POSTOPERATIVE COMPLICATION; PRIORITY JOURNAL; RANDOMIZED CONTROLLED TRIAL; SHOULDER; SURGICAL APPROACH; SURGICAL TECHNIQUE; TREATMENT FAILURE;

EID: 80755135517     PISSN: 03412695     EISSN: 14325195     Source Type: Journal    
DOI: 10.1007/s00264-011-1227-5     Document Type: Article
Times cited : (108)

References (22)
  • 5
    • 79955602719 scopus 로고    scopus 로고
    • Biomechanical in vitro assessment of fixed angle plating using a new concept of locking for the treatment of osteoporotic proximal humerus fractures
    • 10.1007/s00264-010-1021-9
    • G Roderer F Gebhard G Krischak HJ Wilke L Claes 2010 Biomechanical in vitro assessment of fixed angle plating using a new concept of locking for the treatment of osteoporotic proximal humerus fractures Int Orthop 10.1007/s00264-010-1021-9
    • (2010) Int Orthop
    • Roderer, G.1    Gebhard, F.2    Krischak, G.3    Wilke, H.J.4    Claes, L.5
  • 6
    • 34247563357 scopus 로고    scopus 로고
    • The importance of medial support in locked plating of proximal humerus fractures
    • DOI 10.1097/BOT.0b013e3180333094, PII 0000513120070300000006
    • MJ Gardner Y Weil JU Barker BT Kelly DL Helfet DG Lorich 2007 The importance of medial support in locked plating of proximal humerus fractures J Orthop Trauma 21 3 185 191 10.1097/BOT.0b013e3180333094 17473755 10.1097/BOT.0b013e3180333094 (Pubitemid 46673839)
    • (2007) Journal of Orthopaedic Trauma , vol.21 , Issue.3 , pp. 185-191
    • Gardner, M.J.1    Weil, Y.2    Barker, J.U.3    Kelly, B.T.4    Helfet, D.L.5    Lorich, D.G.6
  • 7
    • 78549267138 scopus 로고    scopus 로고
    • The biomechanics of locked plating for repairing proximal humerus fractures with or without medial cortical support
    • 10.1097/TA.0b013e3181beed96 20118814 10.1097/TA.0b013e3181beed96
    • J Lescheid R Zdero S Shah PR Kuzyk EH Schemitsch 2010 The biomechanics of locked plating for repairing proximal humerus fractures with or without medial cortical support J Trauma 69 5 1235 1242 10.1097/TA.0b013e3181beed96 20118814 10.1097/TA.0b013e3181beed96
    • (2010) J Trauma , vol.69 , Issue.5 , pp. 1235-1242
    • Lescheid, J.1    Zdero, R.2    Shah, S.3    Kuzyk, P.R.4    Schemitsch, E.H.5
  • 8
    • 0014851643 scopus 로고
    • Displaced proximal humeral fractures. I. Classification and evaluation
    • 5455339
    • CS Neer 2nd 1970 Displaced proximal humeral fractures. I. Classification and evaluation J Bone Joint Surg Am 52 6 1077 1089 5455339
    • (1970) J Bone Joint Surg Am , vol.52 , Issue.6 , pp. 1077-1089
    • Neer II, C.S.1
  • 10
    • 21244499342 scopus 로고    scopus 로고
    • Fractures in the proximal humerus: Functional outcome and evaluation of 70 patients treated in hospital
    • DOI 10.1007/s00402-005-0803-9
    • T Fjalestad K Stromsoe J Blucher B Tennoe 2005 Fractures in the proximal humerus: functional outcome and evaluation of 70 patients treated in hospital Arch Orthop Trauma Surg 125 5 310 316 10.1007/s00402-005-0803-9 15843948 10.1007/s00402-005-0803-9 (Pubitemid 40895351)
    • (2005) Archives of Orthopaedic and Trauma Surgery , vol.125 , Issue.5 , pp. 310-316
    • Fjalestad, T.1    Stromsoe, K.2    Blucher, J.3    Tennooe, B.4
  • 11
    • 22844452800 scopus 로고    scopus 로고
    • Long-term outcome of a proximal humerus fracture predicted after 1 year: A 13-year prospective population-based follow-up study of 47 patients
    • DOI 10.1080/17453670510041295
    • C Olsson A Nordquist CJ Petersson 2005 Long-term outcome of a proximal humerus fracture predicted after 1 year: a 13-year prospective population-based follow-up study of 47 patients Acta Orthop 76 3 397 402 16156469 (Pubitemid 41039357)
    • (2005) Acta Orthopaedica , vol.76 , Issue.3 , pp. 397-402
    • Olsson, C.1    Nordquist, A.2    Petersson, C.J.3
  • 12
    • 56149111888 scopus 로고    scopus 로고
    • Outcome of proximal humerus fractures treated by PHILOS plate internal fixation. Experience of a district general hospital
    • 19058692
    • R Shahid A Mushtaq J Northover M Maqsood 2008 Outcome of proximal humerus fractures treated by PHILOS plate internal fixation. Experience of a district general hospital Acta Orthop Belg 74 5 602 608 19058692
    • (2008) Acta Orthop Belg , vol.74 , Issue.5 , pp. 602-608
    • Shahid, R.1    Mushtaq, A.2    Northover, J.3    Maqsood, M.4
  • 13
    • 33748957058 scopus 로고    scopus 로고
    • Biomechanical analysis of blade plate versus locking plate fixation for a proximal humerus fracture: Comparison using cadaveric and synthetic humeri
    • DOI 10.1097/01.bot.0000244997.52751.58, PII 0000513120060900000005
    • PC Siffri RD Peindl ER Coley J Norton PM Connor JF Kellam 2006 Biomechanical analysis of blade plate versus locking plate fixation for a proximal humerus fracture: comparison using cadaveric and synthetic humeri J Orthop Trauma 20 8 547 554 10.1097/01.bot.0000244997.52751.58 16990726 10.1097/01.bot.0000244997.52751.58 (Pubitemid 44440008)
    • (2006) Journal of Orthopaedic Trauma , vol.20 , Issue.8 , pp. 547-554
    • Siffri, P.C.1    Peindl, R.D.2    Coley, E.R.3    Norton, J.4    Connor, P.M.5    Kellam, J.F.6
  • 14
    • 70349685127 scopus 로고    scopus 로고
    • Analysis of early failure of the locking compression plate in osteoporotic proximal humerus fractures
    • 10.1007/s00776-009-1382-3 19802672 10.1007/s00776-009-1382-3
    • ID Micic KC Kim DJ Shin SJ Shin PT Kim IH Park IH Jeon 2009 Analysis of early failure of the locking compression plate in osteoporotic proximal humerus fractures J Orthop Sci 14 5 596 601 10.1007/s00776-009-1382-3 19802672 10.1007/s00776-009-1382-3
    • (2009) J Orthop Sci , vol.14 , Issue.5 , pp. 596-601
    • Micic, I.D.1    Kim, K.C.2    Shin, D.J.3    Shin, S.J.4    Kim, P.T.5    Park, I.H.6    Jeon, I.H.7
  • 15
    • 61549111874 scopus 로고    scopus 로고
    • Locked plating of 3- and 4-part proximal humerus fractures in older patients: The effect of initial fracture pattern on outcome
    • 10.1097/BOT.0b013e31819344bf 19169103 10.1097/BOT.0b013e31819344bf
    • BD Solberg CN Moon DP Franco GD Paiement 2009 Locked plating of 3- and 4-part proximal humerus fractures in older patients: the effect of initial fracture pattern on outcome J Orthop Trauma 23 2 113 119 10.1097/BOT. 0b013e31819344bf 19169103 10.1097/BOT.0b013e31819344bf
    • (2009) J Orthop Trauma , vol.23 , Issue.2 , pp. 113-119
    • Solberg, B.D.1    Moon, C.N.2    Franco, D.P.3    Paiement, G.D.4
  • 16
    • 63649103502 scopus 로고    scopus 로고
    • Locking plate fixation for proximal humerus fractures: A comparison with other fixation techniques
    • Friess DM, Attia A (2008) Locking plate fixation for proximal humerus fractures: a comparison with other fixation techniques. Orthopedics 31(12)
    • (2008) Orthopedics , vol.31 , Issue.12
    • Friess, D.M.1    Attia, A.2
  • 17
    • 0038338590 scopus 로고    scopus 로고
    • Proximal humeral fractures: How stiff should an implant be? A comparative mechanical study with new implants in human specimens
    • H Lill P Hepp J Korner JP Kassi AP Verheyden C Josten GN Duda 2003 Proximal humeral fractures: how stiff should an implant be? A comparative mechanical study with new implants in human specimens Arch Orthop Trauma Surg 123 2-3 74 81 10.1007/s00402-002-0465-9 12721684 1:STN:280: DC%2BD3s3gt1SmsQ%3D%3D (Pubitemid 36748526)
    • (2003) Archives of Orthopaedic and Trauma Surgery , vol.123 , Issue.2-3 , pp. 74-81
    • Lill, H.1    Hepp, P.2    Korner, J.3    Kassi, J.-P.4    Verheyden, A.P.5    Josten, C.6    Duda, G.N.7
  • 18
    • 38949117338 scopus 로고    scopus 로고
    • Displacement/screw cutout after open reduction and locked plate fixation of humeral fractures
    • DOI 10.2106/JBJS.F.01351
    • KC Owsley JT Gorczyca 2008 Fracture displacement and screw cutout after open reduction and locked plate fixation of proximal humeral fractures [corrected] J Bone Joint Surg Am 90 2 233 240 10.2106/JBJS.F.01351 18245580 10.2106/JBJS.F.01351 (Pubitemid 351341032)
    • (2008) Journal of Bone and Joint Surgery - Series A , vol.90 , Issue.2 , pp. 233-240
    • Owsley, K.C.1    Gorczyca, J.T.2
  • 19
    • 33748436645 scopus 로고    scopus 로고
    • Proximal humeral fractures: Regional differences in bone mineral density of the humeral head affect the fixation strength of cancellous screws
    • DOI 10.1016/j.jse.2005.09.007, PII S1058274605002843
    • MJ Tingart J Lehtinen D Zurakowski JJ Warner M Apreleva 2006 Proximal humeral fractures: regional differences in bone mineral density of the humeral head affect the fixation strength of cancellous screws J Shoulder Elbow Surg 15 5 620 624 10.1016/j.jse.2005.09.007 16979060 10.1016/j.jse.2005.09.007 (Pubitemid 44344490)
    • (2006) Journal of Shoulder and Elbow Surgery , vol.15 , Issue.5 , pp. 620-624
    • Tingart, M.J.1    Lehtinen, J.2    Zurakowski, D.3    Warner, J.J.P.4    Apreleva, M.5
  • 20
    • 33845320121 scopus 로고    scopus 로고
    • Finite element analysis of the strain distribution in the humeral head tubercles during abduction: Comparison of young and osteoporotic bone
    • DOI 10.1007/s00276-006-0140-x
    • P Clavert M Zerah J Krier P Mille JF Kempf JL Kahn 2006 Finite element analysis of the strain distribution in the humeral head tubercles during abduction: comparison of young and osteoporotic bone Surg Radiol Anat 28 6 581 587 10.1007/s00276-006-0140-x 16937028 10.1007/s00276-006-0140-x (Pubitemid 44873594)
    • (2006) Surgical and Radiologic Anatomy , vol.28 , Issue.6 , pp. 581-587
    • Clavert, Ph.1    Zerah, M.2    Krier, J.3    Mille, P.4    Kempf, J.F.5    Kahn, J.L.6
  • 22
    • 0034278058 scopus 로고    scopus 로고
    • Effect of screw placement on fixation in the humeral head
    • 10.1067/mse.2000.107089 11075327 10.1067/mse.2000.107089
    • AS Liew JA Johnson SD Patterson GJ King DG Chess 2000 Effect of screw placement on fixation in the humeral head J Shoulder Elbow Surg 9 5 423 426 10.1067/mse.2000.107089 11075327 10.1067/mse.2000.107089
    • (2000) J Shoulder Elbow Surg , vol.9 , Issue.5 , pp. 423-426
    • Liew, A.S.1    Johnson, J.A.2    Patterson, S.D.3    King, G.J.4    Chess, D.G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.