메뉴 건너뛰기




Volumn 28, Issue 6, 2006, Pages 581-587

Finite element analysis of the strain distribution in the humeral head tubercles during abduction: Comparison of young and osteoporotic bone

Author keywords

Biomechanics; Finite element analysis; Humerus; Shoulder; Stress distribution

Indexed keywords

ABDUCTION; ACCURACY; ARM MOVEMENT; ARTICLE; BIOMECHANICS; BONE DEFORMATION; BONE DENSITY; BONE STRESS; CANCELLOUS BONE; COMPARATIVE STUDY; COMPUTER MODEL; COMPUTER PROGRAM; COMPUTER SIMULATION; CORTICAL BONE; FINITE ELEMENT ANALYSIS; FRACTURE NONUNION; HISTOPATHOLOGY; HUMERUS FRACTURE; HUMERUS HEAD; IMAGE RECONSTRUCTION; OSTEOPOROSIS; OSTEOSYNTHESIS; PRIORITY JOURNAL; ROTATOR CUFF; STRESS STRAIN RELATIONSHIP; THREE DIMENSIONAL IMAGING; TISSUE STRUCTURE;

EID: 33845320121     PISSN: 09301038     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00276-006-0140-x     Document Type: Article
Times cited : (33)

References (26)
  • 1
    • 0033213751 scopus 로고    scopus 로고
    • Glenoid cancellous bone strength and modulus
    • Anglin C, Tolhurst P, Wyss U, Pichora D (1999) Glenoid cancellous bone strength and modulus. J Biomech 32:1091-1097
    • (1999) J Biomech , vol.32 , pp. 1091-1097
    • Anglin, C.1    Tolhurst, P.2    Wyss, U.3    Pichora, D.4
  • 2
    • 4243289034 scopus 로고    scopus 로고
    • Modelisation 3D par la méthode des éléments finis d'une articulation scapulo-humérale. Application à l'étude des contraintes sur une épaule saine et avec différents types de glènes prothétiques
    • Thesis. Université Paul Sabatier, Toulouse
    • Barea C (1998) Modelisation 3D par la méthode des éléments finis d'une articulation scapulo-humérale. Application à l'étude des contraintes sur une épaule saine et avec différents types de glènes prothétiques. Thesis. Université Paul Sabatier, Toulouse
    • (1998)
    • Barea, C.1
  • 3
    • 4244137696 scopus 로고    scopus 로고
    • Three dimensional finite element modelling of normal and implanted glenoid: Validations and simulations
    • In: Toulouse
    • Barea C, Hobatho M, Darmana R, Mansat P, Mansat M (1998) Three dimensional finite element modelling of normal and implanted glenoid: validations and simulations. In: 11th Conference of the ESB. Toulouse, p 27
    • (1998) 11th Conference of the ESB , pp. 27
    • Barea, C.1    Hobatho, M.2    Darmana, R.3    Mansat, P.4    Mansat, M.5
  • 6
    • 0036851273 scopus 로고    scopus 로고
    • A finite element model of the shoulder: Application to the comparison of normal and osteoarthritic joints
    • Büchler P, Ramaniraka N, Rakotomanana L, Iannotti J, Farron A (2002) A finite element model of the shoulder: Application to the comparison of normal and osteoarthritic joints. Clin Biomech 17:630-639
    • (2002) Clin Biomech , vol.17 , pp. 630-639
    • Büchler, P.1    Ramaniraka, N.2    Rakotomanana, L.3    Iannotti, J.4    Farron, A.5
  • 7
    • 0036851273 scopus 로고    scopus 로고
    • A finite model of the shoulder: Application to the comparison of normal and osteoarthritic joints
    • Büchler P, Ramaniraka N, Rakotomanana L, Iannotti J, Farron A (2002) A finite model of the shoulder: Application to the comparison of normal and osteoarthritic joints. Clin Biomech 17:630-639
    • (2002) Clin Biomech , vol.17 , pp. 630-639
    • Büchler, P.1    Ramaniraka, N.2    Rakotomanana, L.3    Iannotti, J.4    Farron, A.5
  • 9
    • 0031091324 scopus 로고    scopus 로고
    • Bone strength and materials properties of the glenoid
    • Frich L (1997) Bone strength and materials properties of the glenoid. J Shoulder Elbow Surg 6:97-104
    • (1997) J Shoulder Elbow Surg , vol.6 , pp. 97-104
    • Frich, L.1
  • 10
    • 0000131928 scopus 로고
    • Finite element of the glenoid component: Effect of the design parameters on stress distribution
    • Friedman R (1992) Finite element of the glenoid component: Effect of the design parameters on stress distribution. J Shoulder Elbow Surg 1:261-270
    • (1992) J Shoulder Elbow Surg , vol.1 , pp. 261-270
    • Friedman, R.1
  • 11
    • 0023173665 scopus 로고
    • The mechanostat: A proposed pathogenic mechanism of osteoporoses and the bone mass effects of mechanical and non-mechanical agents
    • Frost H (1987) The mechanostat: A proposed pathogenic mechanism of osteoporoses and the bone mass effects of mechanical and non-mechanical agents. Bone Minerology 2:73-85
    • (1987) Bone Minerology , vol.2 , pp. 73-85
    • Frost, H.1
  • 13
    • 0029833374 scopus 로고    scopus 로고
    • Force analysis of rotator cuff muscles
    • Hughes R, An K (1996) Force analysis of rotator cuff muscles. Clin Orthop 330:75-83
    • (1996) Clin Orthop , vol.330 , pp. 75-83
    • Hughes, R.1    An, K.2
  • 14
    • 0023547272 scopus 로고
    • Finite element analysis of acetabular reconstruction. Non cemented threated cups
    • Huiskes R (1987) Finite element analysis of acetabular reconstruction. Non cemented threated cups. Acta Orthop Scand 58:620-625
    • (1987) Acta Orthop Scand , vol.58 , pp. 620-625
    • Huiskes, R.1
  • 15
    • 0026816612 scopus 로고
    • Towards a model for force predictions in the human shoulder
    • Karlsson D, Peterson B (1992) Towards a model for force predictions in the human shoulder. J Biomech 25:189-199
    • (1992) J Biomech , vol.25 , pp. 189-199
    • Karlsson, D.1    Peterson, B.2
  • 16
    • 0031307667 scopus 로고    scopus 로고
    • Stress analysis of glenoid component designs for shoulder arthroplasty
    • Lacroix D, Prendergast P (1997) Stress analysis of glenoid component designs for shoulder arthroplasty. Proc Inst Mech Eng 211:467-474
    • (1997) Proc Inst Mech Eng , vol.211 , pp. 467-474
    • Lacroix, D.1    Prendergast, P.2
  • 17
    • 0016683563 scopus 로고
    • Bone deformation recorded in vivo from strain gauges attached to the human tibial shaft
    • Lanyon L, Hampson W, Goodship A, Shan J (1975) Bone deformation recorded in vivo from strain gauges attached to the human tibial shaft. Acta Orthop Scand 46:256-268
    • (1975) Acta Orthop Scand , vol.46 , pp. 256-268
    • Lanyon, L.1    Hampson, W.2    Goodship, A.3    Shan, J.4
  • 18
    • 0242690992 scopus 로고    scopus 로고
    • Straining of the intact and fractured proximal humerus under physiological-like loading
    • Maldonado Z, Seebeck J, Heller M, Brandt D, Hepp P, Lill H, Duda G (2003) Straining of the intact and fractured proximal humerus under physiological-like loading. J Biomech 36:1865-1873
    • (2003) J Biomech , vol.36 , pp. 1865-1873
    • Maldonado, Z.1    Seebeck, J.2    Heller, M.3    Brandt, D.4    Hepp, P.5    Lill, H.6    Duda, G.7
  • 19
    • 33845288704 scopus 로고    scopus 로고
    • Propriétés mécaniques osseuse de la glène. Application à la modélisation tridimensionnelle par la méthode des éléments finis
    • Thesis. Université Paul Sabatier, Toulouse
    • Mansat P (1996) Propriétés mécaniques osseuse de la glène. Application à la modélisation tridimensionnelle par la méthode des éléments finis. Thesis. Université Paul Sabatier, Toulouse
    • (1996)
    • Mansat, P.1
  • 20
    • 0023805626 scopus 로고
    • Stress analyses of glenoid component designs
    • Orr T, Carter D, Schurman D (1988) Stress analyses of glenoid component designs. Clin Orthop 232:217-224
    • (1988) Clin Orthop , vol.232 , pp. 217-224
    • Orr, T.1    Carter, D.2    Schurman, D.3
  • 21
    • 0020068498 scopus 로고
    • An axisymetric model of acetabular components in total hip arthroplasty
    • Pedersen D, Crowninshield R, Brand R, Johnston R (1982) An axisymetric model of acetabular components in total hip arthroplasty. J Biomech 15:305-315
    • (1982) J Biomech , vol.15 , pp. 305-315
    • Pedersen, D.1    Crowninshield, R.2    Brand, R.3    Johnston, R.4
  • 23
    • 0028439509 scopus 로고
    • Analysis of the kinematic and dynamic behavior of the shoulder mechanism
    • Van der Helm F (1994) Analysis of the kinematic and dynamic behavior of the shoulder mechanism. J Biomech 27:527-550
    • (1994) J Biomech , vol.27 , pp. 527-550
    • Van der Helm, F.1
  • 24
    • 0028434163 scopus 로고
    • A finite element musculoskeletal model of the shoulder mechanism
    • Van der Helm F (1994) A finite element musculoskeletal model of the shoulder mechanism. J Biomech 27:551-569
    • (1994) J Biomech , vol.27 , pp. 551-569
    • Van der Helm, F.1
  • 25
    • 0026410034 scopus 로고
    • Modelling the mechanical effect of muscles with large attachment sites: Application to the shoulder mechanism
    • Van der Helm F, Veenbaas R (1991) Modelling the mechanical effect of muscles with large attachment sites: Application to the shoulder mechanism. J Biomech 21:1151-1163
    • (1991) J Biomech , vol.21 , pp. 1151-1163
    • Van der Helm, F.1    Veenbaas, R.2
  • 26
    • 0029294161 scopus 로고
    • A dynamic shoulder model: Reliability testing and muscle force study
    • Wuelker N, Wirth CJ, Plitz W, Roetman B (1995) A dynamic shoulder model: reliability testing and muscle force study. J Biomech 28:489-499
    • (1995) J Biomech , vol.28 , pp. 489-499
    • Wuelker, N.1    Wirth, C.J.2    Plitz, W.3    Roetman, B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.