메뉴 건너뛰기




Volumn 16, Issue 6, 2011, Pages

Design of a handheld optical coherence microscopy endoscope

Author keywords

Endoscopy; Minimally invasive imaging; Optical coherence imaging; Ovaries

Indexed keywords

AXIAL RESOLUTIONS; CORPUS LUTEUM; COVER GLASS; EX-VIVO; FALLOPIAN TUBE; FULL WIDTH HALF MAXIMUM; HANDHELDS; HIGH NUMERICAL APERTURES; HOPKINS; IMAGING APPLICATIONS; IMAGING DEPTH; LATERAL RESOLUTION; M-LINES; MINIMALLY INVASIVE; MINIMALLY INVASIVE IMAGING; NUMERICAL APERTURE; OPTICAL COHERENCE IMAGING; OPTICAL COHERENCE MICROSCOPY; OVARIES; RELAY LENS; SMALL ANIMAL; STRUCTURAL FEATURE; WATER IMMERSION;

EID: 80455141563     PISSN: 10833668     EISSN: 15602281     Source Type: Journal    
DOI: 10.1117/1.3594149     Document Type: Article
Times cited : (9)

References (38)
  • 3
    • 60749130838 scopus 로고    scopus 로고
    • Deconvolution methods for image deblurring in optical coherence tomography
    • Y. Liu, Y. Liang, G. Mu, and X. Zhu, "Deconvolution methods for image deblurring in optical coherence tomography," J Opt Soc Am A Opt Image Sci Vis. 26(1),72-77 (2009).
    • (2009) J Opt Soc Am A Opt Image Sci Vis. , vol.26 , Issue.1 , pp. 72-77
    • Liu, Y.1    Liang, Y.2    Mu, G.3    Zhu, X.4
  • 5
  • 6
    • 77149153385 scopus 로고    scopus 로고
    • Gabor-based fusion technique for optical coherencemicroscopy
    • J. P. Rolland, P. Meemon, S. Murali, K. P. Thompson, and K. Lee, "Gabor-based fusion technique for optical coherencemicroscopy," Opt. Express 18(4), 3632-3642 (2010).
    • (2010) Opt. Express , vol.18 , Issue.4 , pp. 3632-3642
    • Rolland, J.P.1    Meemon, P.2    Murali, S.3    Thompson, K.P.4    Lee, K.5
  • 7
    • 77951734083 scopus 로고    scopus 로고
    • Assessment of a liquid lens enabled in vivo optical coherence microscope
    • S. Murali, P. Meemon, K. S. Lee,W. P. Kuhn, K. P. Thompson, and J. P. Rolland, "Assessment of a liquid lens enabled in vivo optical coherence microscope," Appl. Opt. 49(16), D145-156 (2010).
    • (2010) Appl. Opt. , vol.49 , Issue.16 , pp. 145-156
    • Murali, S.1    Meemon, P.2    Lee, K.S.3    Kuhn, W.P.4    Thompson, K.P.5    Rolland, J.P.6
  • 10
    • 77949454437 scopus 로고    scopus 로고
    • Alterations of the extracellular matrix in ovarian cancer studied by second harmonic generation imaging microscopy
    • O. Nadiarnykh, R. B. LaComb, M. A. Brewer, and P. J. Campagnola, "Alterations of the extracellular matrix in ovarian cancer studied by second harmonic generation imaging microscopy,"BMCCancer, 10(1), 94-107 (2010).
    • (2010) BMC Cancer , vol.10 , Issue.1 , pp. 94-107
    • Nadiarnykh, O.1    Lacomb, R.B.2    Brewer, M.A.3    Campagnola, P.J.4
  • 12
    • 0030760309 scopus 로고    scopus 로고
    • In vivo endoscopic optical biopsy with optical coherence tomography
    • DOI 10.1126/science.276.5321.2037
    • G. J. Tearney, M. E. Brezinski, B. E. Bouma, S. A. Boppart, C. Pitris, J. F. Southern, and J. G. Fujimoto, "In vivo endoscopic optical biopsy with optical coherence tomography," Science 276(5321), 2037-2039 (1997). (Pubitemid 27443607)
    • (1997) Science , vol.276 , Issue.5321 , pp. 2037-2039
    • Tearney, G.J.1    Brezinski, M.E.2    Bouma, B.E.3    Boppart, S.A.4    Pitris, C.5    Southern, J.F.6    Fujimoto, J.G.7
  • 13
    • 36748999496 scopus 로고    scopus 로고
    • Three-dimensional endomicroscopy using optical coherence tomography
    • D. C. Adler, Y. Chen, R. Huber, J. Schmitt, J. Connolly, and J. G. Fujimoto, "Three-dimensional endomicroscopy using optical coherence tomography," Nat. Photon. 1(12), 709-716 (2007).
    • (2007) Nat. Photon. , vol.1 , Issue.12 , pp. 709-716
    • Adler, D.C.1    Chen, Y.2    Huber, R.3    Schmitt, J.4    Connolly, J.5    Fujimoto, J.G.6
  • 14
    • 40149104422 scopus 로고    scopus 로고
    • In vivo three-dimensional spectral domain endoscopic optical coherence tomography using a microelectromechanical system mirror
    • DOI 10.1364/OL.32.003239
    • W. Jung, D. T. McCormick, Y. Ahn, A. Sepehr, M. Brenner, B. Wong, N. C. Tien, and Z. Chen, "In vivo three-dimensional spectral domain endoscopic optical coherence tomography using a microelectromechanical system mirror," Opt. Lett. 32(22), 3239-3241 (2007). (Pubitemid 351328383)
    • (2007) Optics Letters , vol.32 , Issue.22 , pp. 3239-3241
    • Jung, W.1    McCormick, D.T.2    Ahn, Y.-C.3    Sepehr, A.4    Brenner, M.5    Wong, B.6    Tien, N.C.7    Chen, Z.8
  • 15
    • 33847260140 scopus 로고    scopus 로고
    • Methods and application areas of endoscopic optical coherence tomography
    • Z. Yaqoob, J. Wu, E. J. McDowell, X. Heng, and C. Yang, "Methods and application areas of endoscopic optical coherence tomography," J. Biomed. Opt. 11(6), 063001 (2006).
    • (2006) J. Biomed. Opt. , vol.11 , Issue.6 , pp. 063001
    • Yaqoob, Z.1    Wu, J.2    Mcdowell, E.J.3    Heng, X.4    Yang, C.5
  • 18
    • 65149106821 scopus 로고    scopus 로고
    • Endoscopic OCT with forward-looking probe: Clinical studies in urology and gastroenterology
    • E. Zagaynova, N. Gladkova, N. Shakhova, G. Gelikonov, and V. Gelikonov, "Endoscopic OCT with forward-looking probe: clinical studies in urology and gastroenterology," J. Biophoton. 1(2), 114-128 (2008).
    • (2008) J. Biophoton. , vol.1 , Issue.2 , pp. 114-128
    • Zagaynova, E.1    Gladkova, N.2    Shakhova, N.3    Gelikonov, G.4    Gelikonov, V.5
  • 19
    • 12344268878 scopus 로고    scopus 로고
    • Low-voltage polymer-based scanning cantilever for in vivo optical coherence tomography
    • Y. Wang, M. Bachman, G. Li, S. Guo, B. J. F. Wong, and Z. Chen, "Low-voltage polymer-based scanning cantilever for in vivo optical coherence tomography," Opt. Lett. 30(1), 53-3246 (2005).
    • (2005) Opt. Lett. , vol.30 , Issue.1 , pp. 53-3246
    • Wang, Y.1    Bachman, M.2    Li, G.3    Guo, S.4    Wong, B.J.F.5    Chen, Z.6
  • 21
    • 3943113624 scopus 로고    scopus 로고
    • Rapidscanning forward-imaging miniature endoscope for real-time optical coherence tomography
    • X. Liu, M. J. Cobb, Y. Chen, M. B. Kimmey, and X. Li, "Rapidscanning forward-imaging miniature endoscope for real-time optical coherence tomography," Opt. Lett. 29(15),1763-1765 (2004).
    • (2004) Opt. Lett. , vol.29 , Issue.15 , pp. 1763-1765
    • Liu, X.1    Cobb, M.J.2    Chen, Y.3    Kimmey, M.B.4    Li, X.5
  • 22
    • 0037446956 scopus 로고    scopus 로고
    • Electrostatic micromachine scanning mirror for optical coherence tomography
    • J. M. Zara, S. Yazdanfar, K. D. Rao, J. A. Izatt, and S. W. Smith, "Electrostatic micromachine scanning mirror for optical coherence tomography," Opt. Lett. 28(8), 628-630 (2003).
    • (2003) Opt. Lett. , vol.28 , Issue.8 , pp. 628-630
    • Zara, J.M.1    Yazdanfar, S.2    Rao, K.D.3    Izatt, J.A.4    Smith, S.W.5
  • 23
    • 67649373385 scopus 로고    scopus 로고
    • Single-body lensed-fiber scanning probe actuated by magnetic force for optical imaging
    • E. J. Min, J. Na, S. Y. Ryu, and B. H. Lee, "Single-body lensed-fiber scanning probe actuated by magnetic force for optical imaging," Opt. Lett. 34(12), 1897-1899 (2009).
    • (2009) Opt. Lett. , vol.34 , Issue.12 , pp. 1897-1899
    • Min, E.J.1    Na, J.2    Ryu, S.Y.3    Lee, B.H.4
  • 24
    • 85047682879 scopus 로고    scopus 로고
    • Forward-viewing resonant fiberoptic scanning endoscope of appropriate scanning speed for 3D OCT imaging
    • L. Huo, J. Xi, Y. Wu, and X. Li, "Forward-viewing resonant fiberoptic scanning endoscope of appropriate scanning speed for 3D OCT imaging," Opt. Express, 18(14), 14375-14384 (2010).
    • (2010) Opt. Express , vol.18 , Issue.14 , pp. 14375-14384
    • Huo, L.1    Xi, J.2    Wu, Y.3    Li, X.4
  • 25
    • 77958004527 scopus 로고    scopus 로고
    • Semiresonant operation of a fiber-cantilever piezotube scanner for stable optical coherence tomography endoscope imaging
    • S. Moon, S. Lee, M. Rubinstein, B. J. F. Wong, and Z. Chen, "Semiresonant operation of a fiber-cantilever piezotube scanner for stable optical coherence tomography endoscope imaging," Opt. Express, 18(20), 21183-21197 (2010).
    • (2010) Opt. Express , vol.18 , Issue.20 , pp. 21183-21197
    • Moon, S.1    Lee, S.2    Rubinstein, M.3    Wong, B.J.F.4    Chen, Z.5
  • 26
    • 33745156132 scopus 로고    scopus 로고
    • Paired-angle-rotation scanning optical coherence tomography forward-imaging probe
    • DOI 10.1364/OL.31.001265
    • J. Wu, M. Conry, C. Gu, F. Wang, Z. Yaqoob, and C. Yang, "Paired-angle-rotation scanning optical coherence tomography forward-imaging probe," Opt. Lett. 31(9), 1265-1267 (2006). (Pubitemid 43901261)
    • (2006) Optics Letters , vol.31 , Issue.9 , pp. 1265-1267
    • Wu, J.1    Conry, M.2    Gu, C.3    Wang, F.4    Yaqoob, Z.5    Yang, C.6
  • 27
    • 49649115917 scopus 로고    scopus 로고
    • Handheld forward-imaging needle endoscope for ophthalmic optical coherence tomography inspection
    • S. Han, M. V. Sarunic, J. Wu, M. Humayun, and C. Yang, "Handheld forward-imaging needle endoscope for ophthalmic optical coherence tomography inspection," J. Biomed. Opt. 13(2), 020505 (2008).
    • (2008) J. Biomed. Opt. , vol.13 , Issue.2 , pp. 020505
    • Han, S.1    Sarunic, M.V.2    Wu, J.3    Humayun, M.4    Yang, C.5
  • 28
    • 0001352717 scopus 로고    scopus 로고
    • Endoscopic optical coherence tomography based on a microelectromechanical mirror
    • Y. Pan, H. Xie, and G. K. Fedder, "Endoscopic optical coherence tomography based on a microelectromechanical mirror," Opt. Lett. 26(24), 1966 (2001).
    • (2001) Opt. Lett. , vol.26 , Issue.24 , pp. 1966
    • Pan, Y.1    Xie, H.2    Fedder, G.K.3
  • 29
    • 0242440729 scopus 로고    scopus 로고
    • Endoscopic optical coherence tomography with a modified microelectromechanical systems mirror for detection of bladder cancers
    • T. Xie, H. Xie, G. K. Fedder, and Y. Pan, "Endoscopic optical coherence tomography with a modified microelectromechanical systems mirror for detection of bladder cancers," Appl. Opt. 42(31), 6422-6426 (2003).
    • (2003) Appl. Opt. , vol.42 , Issue.31 , pp. 6422-6426
    • Xie, T.1    Xie, H.2    Fedder, G.K.3    Pan, Y.4
  • 30
    • 34547922743 scopus 로고    scopus 로고
    • Vivo bladder imaging with microelectromechanical-systemsbased endoscopic spectral domain optical coherence tomography
    • Z. Wang, C. S. D. Lee,W. C.Waltzer, J. Liu, H. Xie, Z. Yuan, and Y. Pan, "In vivo bladder imaging with microelectromechanical-systemsbased endoscopic spectral domain optical coherence tomography," J. Biomed. Opt. 12(3), 034009 (2007).
    • (2007) J. Biomed. Opt. , vol.12 , Issue.3 , pp. 034009
    • Wang, Z.1    Lee, C.S.D.2    Waltzer, W.C.3    Liu, J.4    Xie, H.5    Yuan, Z.6    Pan, Y.7
  • 31
    • 4344565790 scopus 로고    scopus 로고
    • A two-axis electrothermal micromirror for endoscopic optical coherence tomography
    • A. Jain, A. Kopa, Y. Pan, G. Fedder, and H. Xie, "A two-axis electrothermal micromirror for endoscopic optical coherence tomography," IEEE J. Sel. Top. Quantum Electron. 10(3), 636-642 (2004).
    • (2004) IEEE J. Sel. Top. Quantum Electron. , vol.10 , Issue.3 , pp. 636-642
    • Jain, A.1    Kopa, A.2    Pan, Y.3    Fedder, G.4    Xie, H.5
  • 32
    • 33645819815 scopus 로고    scopus 로고
    • GRIN lens rod based probe for endoscopic spectral domain optical coherence tomography with fast dynamic focus tracking
    • T. Xie, S. Guo, Z. Chen, D. Mukai, and M. Brenner, "GRIN lens rod based probe for endoscopic spectral domain optical coherence tomography with fast dynamic focus tracking," Opt. Express, 14(8), 3238-3246 (2006).
    • (2006) Opt. Express , vol.14 , Issue.8 , pp. 3238-3246
    • Xie, T.1    Guo, S.2    Chen, Z.3    Mukai, D.4    Brenner, M.5
  • 33
    • 77950349126 scopus 로고    scopus 로고
    • Vivo three-dimensional imaging of normal tissue and tumors in the rabbit pleural cavity using endoscopic swept source optical coherence tomography with thoracoscopic guidance
    • T. Xie, G. Liu, K. Kreuter, S. Mahon, H. Colt, D. Mukai, G. M. Peavy, Z. Chen, and M. Brenner, "In vivo three-dimensional imaging of normal tissue and tumors in the rabbit pleural cavity using endoscopic swept source optical coherence tomography with thoracoscopic guidance," J. Biomed. Opt. 14(6), 064045 (2009).
    • (2009) J. Biomed. Opt. , vol.14 , Issue.6 , pp. 064045
    • Xie, T.1    Liu, G.2    Kreuter, K.3    Mahon, S.4    Colt, H.5    Mukai, D.6    Peavy, G.M.7    Chen, Z.8    Brenner, M.9
  • 34
    • 77749279964 scopus 로고    scopus 로고
    • High speed optical coherencemicroscopy with autofocus adjustment and a miniaturized endoscopic imaging probe
    • A. D. Aguirre, J. Sawinski, S. W. Huang, C. Zhou, W. Denk, and J. G. Fujimoto, "High speed optical coherencemicroscopy with autofocus adjustment and a miniaturized endoscopic imaging probe," Opt. Express 18(5), 4222-4239 (2010).
    • (2010) Opt. Express , vol.18 , Issue.5 , pp. 4222-4239
    • Aguirre, A.D.1    Sawinski, J.2    Huang, S.W.3    Zhou, C.4    Denk, W.5    Fujimoto, J.G.6
  • 35
    • 65349130642 scopus 로고    scopus 로고
    • Design of a handheld optical coherence microscopy endoscope
    • V. Korde, E. Liebmann, and J. K. Barton, "Design of a handheld optical coherence microscopy endoscope," Proc. SPIE 7172, 71720D (2009).
    • (2009) Proc. SPIE , vol.7172
    • Korde, V.1    Liebmann, E.2    Barton, J.K.3
  • 37
    • 1642602745 scopus 로고    scopus 로고
    • Ultrahigh-resolution optical coherence tomography
    • W. Drexler, "Ultrahigh-resolution optical coherence tomography," J. Biomed. Opt. 9(1), 47-74 (2004).
    • (2004) J. Biomed. Opt. , vol.9 , Issue.1 , pp. 47-74
    • Drexler, W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.