메뉴 건너뛰기




Volumn 81, Issue 4, 2011, Pages

Influence of antiflatulent dietary advice on intrafraction motion for prostate cancer radiotherapy

Author keywords

Antiflatulent diet; Fiducial markers; IMRT; Intensity modulated radiotherapy; Intrafraction motion; Prostate cancer

Indexed keywords

ANTIFLATULENT DIET; FIDUCIAL MARKER; IMRT; INTENSITY-MODULATED RADIOTHERAPY; INTRAFRACTION MOTION; PROSTATE CANCERS;

EID: 80255131311     PISSN: 03603016     EISSN: 1879355X     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2011.04.062     Document Type: Article
Times cited : (25)

References (36)
  • 8
    • 33846211921 scopus 로고    scopus 로고
    • Analysis of fiducial marker-based position verification in the external beam radiotherapy of patients with prostate cancer
    • DOI 10.1016/j.radonc.2006.11.002, PII S0167814006005937
    • U.A. Van Der Heide, A.N. Kotte, and H. Dehnad Analysis of fiducial marker-based position verification in the external beam radiotherapy of patients with prostate cancer Radiother Oncol 82 2007 38 45 (Pubitemid 46097130)
    • (2007) Radiotherapy and Oncology , vol.82 , Issue.1 , pp. 38-45
    • Van Der Heide, U.A.1    Kotte, A.N.T.J.2    Dehnad, H.3    Hofman, P.4    Lagenijk, J.J.W.5    Van Vulpen, M.6
  • 9
    • 68649123356 scopus 로고    scopus 로고
    • Inferences about prostate intrafraction motion from pre- and post-treatment volumetric imaging
    • J. Adamson, and Q. Wu Inferences about prostate intrafraction motion from pre- and post-treatment volumetric imaging Int J Radiat Oncol Biol Phys 75 2009 260 267
    • (2009) Int J Radiat Oncol Biol Phys , vol.75 , pp. 260-267
    • Adamson, J.1    Wu, Q.2
  • 10
    • 77953593637 scopus 로고    scopus 로고
    • A cinematic magnetic resonance imaging study of Milk of Magnesia laxative and an antiflatulent diet to reduce intrafraction prostate motion
    • A.M. Nichol, P.R. Warde, and G.A. Lockwood A cinematic magnetic resonance imaging study of Milk of Magnesia laxative and an antiflatulent diet to reduce intrafraction prostate motion Int J Radiat Oncol Biol Phys 77 2010 1072 1078
    • (2010) Int J Radiat Oncol Biol Phys , vol.77 , pp. 1072-1078
    • Nichol, A.M.1    Warde, P.R.2    Lockwood, G.A.3
  • 13
    • 0034748364 scopus 로고    scopus 로고
    • Positioning errors and prostate motion during conformal prostate radiotherapy using on-line isocentre set-up verification and implanted prostate markers
    • DOI 10.1016/S0167-8140(01)00452-2, PII S0167814001004522
    • J. Wu, T. Haycocks, and H. Alasti Positioning errors and prostate motion during conformal prostate radiotherapy using on-line isocentre set-up verification and implanted prostate markers Radiother Oncol 61 2001 127 133 (Pubitemid 33016571)
    • (2001) Radiotherapy and Oncology , vol.61 , Issue.2 , pp. 127-133
    • Wu, J.1    Haycocks, T.2    Alasti, H.3    Ottewell, G.4    Middlemiss, N.5    Abdolell, M.6    Warde, P.7    Toi, A.8    Catton, C.9
  • 15
    • 51049109312 scopus 로고    scopus 로고
    • Reduction of prostate motion by removal of gas in rectum during radiotherapy
    • I. Ogino, H. Uemura, and T. Inoue Reduction of prostate motion by removal of gas in rectum during radiotherapy Int J Radiat Oncol Biol Phys 72 2008 456 466
    • (2008) Int J Radiat Oncol Biol Phys , vol.72 , pp. 456-466
    • Ogino, I.1    Uemura, H.2    Inoue, T.3
  • 18
    • 45849084226 scopus 로고    scopus 로고
    • High-dose intensity-modulated radiotherapy for prostate cancer using daily fiducial marker-based position verification: Acute and late toxicity in 331 patients
    • I.M. Lips, H. Dehnad, and C.H. Van Gils High-dose intensity-modulated radiotherapy for prostate cancer using daily fiducial marker-based position verification: Acute and late toxicity in 331 patients Radiat Oncol 3 2008 15
    • (2008) Radiat Oncol , vol.3 , pp. 15
    • Lips, I.M.1    Dehnad, H.2    Van Gils, C.H.3
  • 20
    • 77953963382 scopus 로고    scopus 로고
    • Long-term experience with transrectal and transperineal implantations of fiducial gold markers in the prostate for position verification in external beam radiotherapy: Feasibility, toxicity and quality of life
    • M.R. Moman, U.A. Van Der Heide, and A.N. Kotte Long-term experience with transrectal and transperineal implantations of fiducial gold markers in the prostate for position verification in external beam radiotherapy: Feasibility, toxicity and quality of life Radiother Oncol 96 2010 38 42
    • (2010) Radiother Oncol , vol.96 , pp. 38-42
    • Moman, M.R.1    Van Der Heide, U.A.2    Kotte, A.N.3
  • 21
    • 67651115905 scopus 로고    scopus 로고
    • Effect of translational and rotational errors on complex dose distributions with off-line and on-line position verification
    • I.M. Lips, U.A. Van Der Heide, and A.N. Kotte Effect of translational and rotational errors on complex dose distributions with off-line and on-line position verification Int J Radiat Oncol Biol Phys 74 2009 1600 1608
    • (2009) Int J Radiat Oncol Biol Phys , vol.74 , pp. 1600-1608
    • Lips, I.M.1    Van Der Heide, U.A.2    Kotte, A.N.3
  • 22
    • 0034661767 scopus 로고    scopus 로고
    • Detection of fiducial gold markers for automatic on-line megavoltage position verification using a marker extraction kernel (MEK)
    • DOI 10.1016/S0360-3016(00)00523-X, PII S036030160000523X
    • A. Nederveen, J. Lagendijk, and P. Hofman Detection of fiducial gold markers for automatic on-line megavoltage position verification using a marker extraction kernel (MEK) Int J Radiat Oncol Biol Phys 47 2000 1435 1442 (Pubitemid 30421198)
    • (2000) International Journal of Radiation Oncology Biology Physics , vol.47 , Issue.5 , pp. 1435-1442
    • Nederveen, A.1    Lagendijk, J.2    Hofman, P.3
  • 23
    • 58149234967 scopus 로고    scopus 로고
    • Optimizing monoscopic kV fluoro acquisition for prostate intrafraction motion evaluation
    • J. Adamson, and Q. Wu Optimizing monoscopic kV fluoro acquisition for prostate intrafraction motion evaluation Phys Med Biol 54 2009 117 133
    • (2009) Phys Med Biol , vol.54 , pp. 117-133
    • Adamson, J.1    Wu, Q.2
  • 26
    • 80255140661 scopus 로고    scopus 로고
    • A simple method to reduce organ motion in prostate cancer - Use by quantification of interfraction motion of the gland
    • B. Hentschel, A. Lilienthal, and W. Oehler A simple method to reduce organ motion in prostate cancer - Use by quantification of interfraction motion of the gland Radiother Oncol 81 2006 1061
    • (2006) Radiother Oncol , vol.81 , pp. 1061
    • Hentschel, B.1    Lilienthal, A.2    Oehler, W.3
  • 27
    • 2442629629 scopus 로고    scopus 로고
    • Epidemiology of Constipation in North America: A Systematic Review
    • DOI 10.1111/j.1572-0241.2004.04114.x
    • P.D. Higgins, and J.F. Johanson Epidemiology of constipation in North America: A systematic review Am J Gastroenterol 99 2004 750 759 (Pubitemid 38612817)
    • (2004) American Journal of Gastroenterology , vol.99 , Issue.4 , pp. 750-759
    • Higgins, P.D.R.1    Johanson, J.F.2
  • 29
    • 80255133014 scopus 로고    scopus 로고
    • Effects of dietary counseling on gastrointestinal complications and quality of life: A randomised controlled trial in prostate cancer patients undergoing radiotherapy
    • A. Pettersson, C. Persson, and B. Johansson Effects of dietary counseling on gastrointestinal complications and quality of life: A randomised controlled trial in prostate cancer patients undergoing radiotherapy EJC Suppl 5 2007 1127
    • (2007) EJC Suppl , vol.5 , pp. 1127
    • Pettersson, A.1    Persson, C.2    Johansson, B.3
  • 31
    • 0029844327 scopus 로고    scopus 로고
    • Factors influencing frequency of flatus emission by healthy subjects
    • J.K. Furne, and M.D. Levitt Factors influencing frequency of flatus emission by healthy subjects Dig Dis Sci 41 1996 1631 1635 (Pubitemid 26285751)
    • (1996) Digestive Diseases and Sciences , vol.41 , Issue.8 , pp. 1631-1635
    • Furne, J.K.1    Levitt, M.D.2
  • 32
    • 42949150341 scopus 로고    scopus 로고
    • Dosimetric consequences of intrafraction prostate motion
    • H.S. Li, I.J. Chetty, and C.A. Enke Dosimetric consequences of intrafraction prostate motion Int J Radiat Oncol Biol Phys 71 2008 801 812
    • (2008) Int J Radiat Oncol Biol Phys , vol.71 , pp. 801-812
    • Li, H.S.1    Chetty, I.J.2    Enke, C.A.3
  • 33
    • 77953835808 scopus 로고    scopus 로고
    • A failure detection strategy for intrafraction prostate motion monitoring with on-board imagers for fixed-gantry IMRT
    • W. Liu, G. Luxton, and L. Xing A failure detection strategy for intrafraction prostate motion monitoring with on-board imagers for fixed-gantry IMRT Int J Radiat Oncol Biol Phys 78 2010 904 911
    • (2010) Int J Radiat Oncol Biol Phys , vol.78 , pp. 904-911
    • Liu, W.1    Luxton, G.2    Xing, L.3
  • 34
    • 80255133013 scopus 로고    scopus 로고
    • On-line correction for intrafraction motion in prostate patients with fiducial markers
    • Presented at the Maastricht
    • Van Os M, Dirkx M, Rajan V, et al. On-line correction for intrafraction motion in prostate patients with fiducial markers. Presented at the 10th Biannual ESTRO Meeting, Maastricht 2009.
    • (2009) 10th Biannual ESTRO Meeting
    • Van Os, M.1    Dirkx, M.2    Rajan, V.3
  • 36
    • 70149091087 scopus 로고    scopus 로고
    • Integrating a 1.5 T MRI scanner with a 6 MV accelerator: Proof of concept
    • B.W. Raaymakers, J.J. Lagendijk, and J. Overweg Integrating a 1.5 T MRI scanner with a 6 MV accelerator: Proof of concept Phys Med Biol 54 2009 N229 N237
    • (2009) Phys Med Biol , vol.54
    • Raaymakers, B.W.1    Lagendijk, J.J.2    Overweg, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.