메뉴 건너뛰기




Volumn 52, Issue 1, 2012, Pages 12-19

In vitro evaluation of the impact of ultrasound scanner settings and contrast bolus volume on time-intensity curves

Author keywords

Liver malignancy; Microvascular blood flow quantification; Therapy monitoring; Ultrasound contrast agents

Indexed keywords

BLOOD VESSELS; DIAGNOSIS; IMAGE ENHANCEMENT; IMAGE SEGMENTATION; PIXELS; SCANNING;

EID: 80054710643     PISSN: 0041624X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ultras.2011.06.003     Document Type: Article
Times cited : (24)

References (27)
  • 2
    • 8844236115 scopus 로고    scopus 로고
    • Measuring tumour vascular response to antivascular and antiangiogenic drugs
    • G.M. Tozer Measuring tumour vascular response to antivascular and antiangiogenic drugs Brit. J. Radiol. 76 Spec 1 2003 S23 S35
    • (2003) Brit. J. Radiol. , vol.76 , Issue.SPEC. 1
    • Tozer, G.M.1
  • 3
    • 40349112983 scopus 로고    scopus 로고
    • Early antiangiogenic activity of bevacizumab evaluated by computed tomography perfusion scan in patients with advanced hepatocellular carcinoma
    • DOI 10.1634/theoncologist.2007-0174
    • A.X. Zhu, N.S. Holalkere, A. Muzikansky, K. Horgan, and D.V. Sahani Early antiangiogenic activity of bevacizumab evaluated by computed tomography perfusion scan in patients with advanced hepatocellular carcinoma Oncologist 13 2008 120 125 (Pubitemid 351342575)
    • (2008) Oncologist , vol.13 , Issue.2 , pp. 120-125
    • Zhu, A.X.1    Holalkere, N.S.2    Muzikansky, A.3    Horgan, K.4    Sahani, D.V.5
  • 5
    • 76749170854 scopus 로고    scopus 로고
    • Metastatic renal cell carcinoma treated with sunitinib: Early evaluation of treatment response using dynamic contrast-enhanced ultrasonography
    • N. Lassau, S. Koscielny, L. Albiges, L. Chami, B. Benatsou, M. Chebil, A. Roche, and B.J. Escudier Metastatic renal cell carcinoma treated with sunitinib: early evaluation of treatment response using dynamic contrast-enhanced ultrasonography Clin. Cancer Res. 16 2010 1216 1225
    • (2010) Clin. Cancer Res. , vol.16 , pp. 1216-1225
    • Lassau, N.1    Koscielny, S.2    Albiges, L.3    Chami, L.4    Benatsou, B.5    Chebil, M.6    Roche, A.7    Escudier, B.J.8
  • 6
    • 78650627466 scopus 로고    scopus 로고
    • Advanced hepatocellular carcinoma: Early evaluation of response to bevacizumab therapy at dynamic contrast-enhanced US with quantification - Preliminary results
    • N. Lassau, S. Koscielny, L. Chami, M. Chebil, B. Benatsou, A. Roche, M. Ducreux, D. Malka, and V. Boige Advanced hepatocellular carcinoma: early evaluation of response to bevacizumab therapy at dynamic contrast-enhanced US with quantification - preliminary results Radiology 258 2011 291 300
    • (2011) Radiology , vol.258 , pp. 291-300
    • Lassau, N.1    Koscielny, S.2    Chami, L.3    Chebil, M.4    Benatsou, B.5    Roche, A.6    Ducreux, M.7    Malka, D.8    Boige, V.9
  • 7
    • 79960686957 scopus 로고    scopus 로고
    • Dynamic microbubble contrast-enhanced ultrasound (DCE-US) to measure tumor response to targeted therapy: A proposed clinical protocol with results from renal cell carcinoma patients receiving anti-angiogenic therapy
    • [Epub ahead of print]
    • R. Williams, J.M. Hudson, B. Lloyd, A. Sureshkumar, G. Lueck, L. Milot, M. Atri, G. Bjarnason, P.N. Burns, Dynamic microbubble contrast-enhanced ultrasound (DCE-US) to measure tumor response to targeted therapy: a proposed clinical protocol with results from renal cell carcinoma patients receiving anti-angiogenic therapy, Radiology (2011) [Epub ahead of print].
    • (2011) Radiology
    • Williams, R.1    Hudson, J.M.2    Lloyd, B.3    Sureshkumar, A.4    Lueck, G.5    Milot, L.6    Atri, M.7    Bjarnason, G.8    Burns, P.N.9
  • 8
    • 40349113040 scopus 로고    scopus 로고
    • Dynamic contrast-enhanced ultrasonography (DCE-US) with quantification of tumor perfusion: A new diagnostic tool to evaluate the early effects of antiangiogenic treatment
    • N. Lassau, L. Chami, B. Benatsou, P. Peronneau, and A. Roche Dynamic contrast-enhanced ultrasonography (DCE-US) with quantification of tumor perfusion: a new diagnostic tool to evaluate the early effects of antiangiogenic treatment Eur. Radiol. 17 Suppl. 6 2007 F89 F98
    • (2007) Eur. Radiol. , vol.17 , Issue.SUPPL. 6
    • Lassau, N.1    Chami, L.2    Benatsou, B.3    Peronneau, P.4    Roche, A.5
  • 9
    • 77957358387 scopus 로고    scopus 로고
    • Microbubble-enhanced US in body imaging: What role?
    • S.R. Wilson, and P.N. Burns Microbubble-enhanced US in body imaging: what role? Radiology 257 2010 24 39
    • (2010) Radiology , vol.257 , pp. 24-39
    • Wilson, S.R.1    Burns, P.N.2
  • 10
    • 77953255183 scopus 로고    scopus 로고
    • Indicator dilution models for the quantification of microvascular blood flow with bolus administration of ultrasound contrast agents
    • C. Strouthos, M. Lampaskis, V. Sboros, A. McNeilly, and M. Averkiou Indicator dilution models for the quantification of microvascular blood flow with bolus administration of ultrasound contrast agents IEEE Trans. Ultrason. Ferroelectr. Freq. Control 57 2010 1296 1310
    • (2010) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.57 , pp. 1296-1310
    • Strouthos, C.1    Lampaskis, M.2    Sboros, V.3    McNeilly, A.4    Averkiou, M.5
  • 11
    • 0032101113 scopus 로고    scopus 로고
    • A mathematical model for the assessment of hemodynamic parameters using quantitative contrast echocardiography
    • DOI 10.1109/10.678610, PII S0018929498037161
    • X. Chen, K.Q. Schwarz, D. Phillips, S.D. Steinmetz, and R. Schlief A mathematical model for the assessment of hemodynamic parameters using quantitative contrast echocardiography IEEE Trans. Biomed. Eng. 45 1998 754 765 (Pubitemid 28294279)
    • (1998) IEEE Transactions on Biomedical Engineering , vol.45 , Issue.6 , pp. 754-765
    • Chen, X.1    Schwarz, K.Q.2    Phillips, D.3    Steinmetz, S.D.4    Schlief, R.5
  • 12
    • 33748976883 scopus 로고    scopus 로고
    • To predict progression-free survival and overall survival in metastatic renal cancer treated with sorafenib: Pilot study using dynamic contrast-enhanced Doppler ultrasound
    • DOI 10.1016/j.ejca.2006.04.023, PII S0959804906006071
    • M. Lamuraglia, B. Escudier, L. Chami, B. Schwartz, J. Leclere, A. Roche, and N. Lassau To predict progression-free survival and overall survival in metastatic renal cancer treated with sorafenib: pilot study using dynamic contrast-enhanced Doppler ultrasound Eur. J. Cancer 42 2006 2472 2479 (Pubitemid 44442955)
    • (2006) European Journal of Cancer , vol.42 , Issue.15 , pp. 2472-2479
    • Lamuraglia, M.1    Escudier, B.2    Chami, L.3    Schwartz, B.4    Leclere, J.5    Roche, A.6    Lassau, N.7
  • 14
    • 73449145667 scopus 로고    scopus 로고
    • Quantitative contrast enhanced ultrasound of the liver for time intensity curves - Reliability and potential sources of errors
    • A. Ignee, M. Jedrejczyk, G. Schuessler, W. Jakubowski, and C.F. Dietrich Quantitative contrast enhanced ultrasound of the liver for time intensity curves - reliability and potential sources of errors Eur. J. Radiol. 73 2010 153 158
    • (2010) Eur. J. Radiol. , vol.73 , pp. 153-158
    • Ignee, A.1    Jedrejczyk, M.2    Schuessler, G.3    Jakubowski, W.4    Dietrich, C.F.5
  • 15
    • 0033978497 scopus 로고    scopus 로고
    • Are microbubbles free flowing tracers through the myocardium? Comparison of indicator-dilution curves obtained from dye dilution and echo contrast using harmonic power Doppler imaging
    • K. Tiemann, T. Schlosser, C. Pohl, D. Bimmel, G. Wietasch, A. Hoeft, J. Likungu, C. Vahlhaus, S. Kuntz, N.C. Nanda, H. Becher, and B. Luderitz Are microbubbles free flowing tracers through the Myocardium? Comparison of indicator-dilution curves obtained from dye dilution and echo contrast using harmonic power Doppler imaging Echocardiography 17 2000 17 27 (Pubitemid 30054254)
    • (2000) Echocardiography , vol.17 , Issue.1 , pp. 17-27
    • Tiemann, K.1    Schlosser, T.2    Pohl, C.3    Bimmel, D.4    Wietasch, G.5    Hoeft, A.6    Likungu, J.7    Vahlhaus, C.8    Kuntz, S.9    Nanda, N.C.10    Becher, H.11    Luderitz, B.12
  • 16
    • 0042844541 scopus 로고    scopus 로고
    • Blood flow quantification with contrast-enhanced US: "Entrance in the section" phenomenon - Phantom and rabbit study
    • DOI 10.1148/radiol.2282020699
    • O. Lucidarme, S. Franchi-Abella, J.M. Correas, S.L. Bridal, E. Kurtisovski, and G. Berger Blood flow quantification with contrast-enhanced US: "entrance in the section" phenomenon - phantom and rabbit study Radiology 228 2003 473 479 (Pubitemid 36910090)
    • (2003) Radiology , vol.228 , Issue.2 , pp. 473-479
    • Lucidarme, O.1    Franchi-Abella, S.2    Correas, J.-M.3    Bridal, S.L.4    Kurtisovski, E.5    Berger, G.6
  • 18
    • 77957945760 scopus 로고    scopus 로고
    • Perfusion quantification using dynamic contrast-enhanced ultrasound: The impact of dynamic range and gain on time-intensity curves
    • T.P. Gauthier, M.A. Averkiou, and E.L. Leen Perfusion quantification using dynamic contrast-enhanced ultrasound: the impact of dynamic range and gain on time-intensity curves Ultrasonics 51 2011 102 106
    • (2011) Ultrasonics , vol.51 , pp. 102-106
    • Gauthier, T.P.1    Averkiou, M.A.2    Leen, E.L.3
  • 19
    • 77955543678 scopus 로고    scopus 로고
    • Contrast ultrasonography: Necessity of linear data processing for the quantification of tumor vascularization
    • P. Peronneau, N. Lassau, I. Leguerney, A. Roche, and D. Cosgrove Contrast ultrasonography: necessity of linear data processing for the quantification of tumor vascularization Ultraschall Med. 31 2010 370 378
    • (2010) Ultraschall Med. , vol.31 , pp. 370-378
    • Peronneau, P.1    Lassau, N.2    Leguerney, I.3    Roche, A.4    Cosgrove, D.5
  • 20
    • 67649382721 scopus 로고    scopus 로고
    • In-vivo perfusion quantification by contrast ultrasound: Validation of the use of linearized video data vs. raw RF data
    • IEEE
    • N.G. Rognin, P. Frinking, M. Costa, M. Arditi, In-vivo perfusion quantification by contrast ultrasound: validation of the use of linearized video data vs. raw RF data, in: Ultrasonics Symposium, 2008. IUS 2008. IEEE, 2008, pp. 1690-1693.
    • (2008) Ultrasonics Symposium, 2008. IUS 2008 , pp. 1690-1693
    • Rognin, N.G.1    Frinking, P.2    Costa, M.3    Arditi, M.4
  • 21
    • 0001747857 scopus 로고
    • An empirical formula for indicator-dilution curves as obtained in human beings
    • R.W. Stow, and P.S. Hetzel An empirical formula for indicator-dilution curves as obtained in human beings J. Appl. Physiol. 7 1954 161 167
    • (1954) J. Appl. Physiol. , vol.7 , pp. 161-167
    • Stow, R.W.1    Hetzel, P.S.2
  • 22
    • 74849138633 scopus 로고    scopus 로고
    • Investigation of the relationship of nonlinear backscattered ultrasound intensity with microbubble concentration at low MI
    • M. Lampaskis, and M. Averkiou Investigation of the relationship of nonlinear backscattered ultrasound intensity with microbubble concentration at low MI Ultrasound Med. Biol. 36 2010 306 312
    • (2010) Ultrasound Med. Biol. , vol.36 , pp. 306-312
    • Lampaskis, M.1    Averkiou, M.2
  • 24
    • 0032983025 scopus 로고    scopus 로고
    • The influence of Doppler system settings on the clearance kinetics of different ultrasound contrast agents
    • DOI 10.1016/S0929-8266(99)00026-9, PII S0929826699000269
    • G. Seidel, M. Vidal-Langwasser, C. Algermissen, T. Gerriets, and M. Kaps The influence of Doppler system settings on the clearance kinetics of different ultrasound contrast agents Eur. J. Ultrasound 9 1999 167 175 (Pubitemid 29318015)
    • (1999) European Journal of Ultrasound , vol.9 , Issue.2 , pp. 167-175
    • Seidel, G.1    Vidal-Langwasser, M.2    Algermissen, C.3    Gerriets, T.4    Kaps, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.