메뉴 건너뛰기




Volumn 44, Issue 16, 2011, Pages 1329-1337

Determination of serum vitamins 25-OH-D2 and 25-OH-D3 with liquid chromatography-tandem mass spectrometry using atmospheric pressure chemical ionization or electrospray source and core-shell or sub-2μm particle columns: A comparative study

Author keywords

25 Hydroxyvitamin D2; 25 Hydroxyvitamin D3; Chromatography; High pressure liquid; Tandem mass spectrometry

Indexed keywords

25 HYDROXYERGOCALCIFEROL; CALCIFEDIOL;

EID: 80054052886     PISSN: 00099120     EISSN: 18732933     Source Type: Journal    
DOI: 10.1016/j.clinbiochem.2011.08.1134     Document Type: Article
Times cited : (27)

References (32)
  • 1
    • 77950363105 scopus 로고    scopus 로고
    • Epidemiology of vitamin D in healthy and disease
    • Wang S. Epidemiology of vitamin D in healthy and disease. Nutr Res Rev 2009, 22:188-203.
    • (2009) Nutr Res Rev , vol.22 , pp. 188-203
    • Wang, S.1
  • 2
    • 66849099880 scopus 로고    scopus 로고
    • Existing and potentially novel functional markers of vitamin D status: a systematic review
    • Seamans K.M., Cashman K.D. Existing and potentially novel functional markers of vitamin D status: a systematic review. Am J Clin Nutr 2009, 89:1997S-2008S.
    • (2009) Am J Clin Nutr , vol.89
    • Seamans, K.M.1    Cashman, K.D.2
  • 4
    • 84860545614 scopus 로고    scopus 로고
    • Institute of Medicine of The National Academies; Report Brief released on 11/30/2010. Available at:. Accessed on May 25
    • Institute of Medicine of The National Academies; Report Brief released on 11/30/2010. Available at: http://www.iom.edu/Reports/2010/Dietary-Reference-Intakes-for-Calcium-and-Vitamin-D/Report-Brief.aspx?page=2. Accessed on May 25, 2011.
    • (2011)
  • 5
    • 77951097205 scopus 로고    scopus 로고
    • Measurement of 25-hydroxyvitamin D in the clinical laboratory: current procedures, performance characteristics and limitations
    • Wallace A.M., Gibson S., de la Hunty A., Lambert-Allardt C., Ashwell M. Measurement of 25-hydroxyvitamin D in the clinical laboratory: current procedures, performance characteristics and limitations. Steroids 2010, 75:477-488.
    • (2010) Steroids , vol.75 , pp. 477-488
    • Wallace, A.M.1    Gibson, S.2    de la Hunty, A.3    Lambert-Allardt, C.4    Ashwell, M.5
  • 6
    • 77952691050 scopus 로고    scopus 로고
    • Advances in determination of vitamin D related compounds in biological samples using liquid chromatography-mass spectrometry: a review
    • Higashi T., Shiomada K., Toyo'oka T. Advances in determination of vitamin D related compounds in biological samples using liquid chromatography-mass spectrometry: a review. J Chromatogr B 2010, 878:1654-1661.
    • (2010) J Chromatogr B , vol.878 , pp. 1654-1661
    • Higashi, T.1    Shiomada, K.2    Toyo'oka, T.3
  • 7
    • 78650905587 scopus 로고    scopus 로고
    • Progress of liquid chromatography-mass spectrometry in measurement of vitamin D metabolites and analogues
    • El-Khoury J.M., Reineks E.Z., Wang S. Progress of liquid chromatography-mass spectrometry in measurement of vitamin D metabolites and analogues. Clin Biochem 2011, 44:66-76.
    • (2011) Clin Biochem , vol.44 , pp. 66-76
    • El-Khoury, J.M.1    Reineks, E.Z.2    Wang, S.3
  • 8
    • 33747846300 scopus 로고    scopus 로고
    • Simultaneous determination of 12 steroids by isotope dilution liquid chromatography-photospray ionization tandem mass spectrometry
    • Guo T., Taylor R.L., Singh R.J., Soldin S.J. Simultaneous determination of 12 steroids by isotope dilution liquid chromatography-photospray ionization tandem mass spectrometry. Clin Chim Acta 2006, 372:76-82.
    • (2006) Clin Chim Acta , vol.372 , pp. 76-82
    • Guo, T.1    Taylor, R.L.2    Singh, R.J.3    Soldin, S.J.4
  • 9
    • 77952736922 scopus 로고    scopus 로고
    • Rapid and simultaneous determination of 25-OH-vitamin D2 and D3 in human serum by LC/MS/MS: Validation and uncertainty assessment
    • Gören A.C., Bilsel G., Bilsel M. Rapid and simultaneous determination of 25-OH-vitamin D2 and D3 in human serum by LC/MS/MS: Validation and uncertainty assessment. J Chem Metrl 2007, 1:1-9.
    • (2007) J Chem Metrl , vol.1 , pp. 1-9
    • Gören, A.C.1    Bilsel, G.2    Bilsel, M.3
  • 10
    • 24144438617 scopus 로고    scopus 로고
    • Routine isotope-dilution liquid chromatography-tandem mass spectrometry assay for simultaneous measurement of the 25-hydroxy metabolites of vitamins D2 and D3
    • Maunsell Z., Wright D.J., Rainbow S.J. Routine isotope-dilution liquid chromatography-tandem mass spectrometry assay for simultaneous measurement of the 25-hydroxy metabolites of vitamins D2 and D3. Clin Chem 2005, 51:1683-1690.
    • (2005) Clin Chem , vol.51 , pp. 1683-1690
    • Maunsell, Z.1    Wright, D.J.2    Rainbow, S.J.3
  • 11
    • 33744494040 scopus 로고    scopus 로고
    • Quantification of serum 25-hydroxyvitamin D(2) and D(3) using HPLC-tandem mass spectrometry and examination of reference intervals for diagnosis of vitamin D deficiency
    • Saenger A.K., Laha T.J., Bremner D.E., Sadrzadeh S.M.H. Quantification of serum 25-hydroxyvitamin D(2) and D(3) using HPLC-tandem mass spectrometry and examination of reference intervals for diagnosis of vitamin D deficiency. Am J Clin Pathol 2006, 125:914-920.
    • (2006) Am J Clin Pathol , vol.125 , pp. 914-920
    • Saenger, A.K.1    Laha, T.J.2    Bremner, D.E.3    Sadrzadeh, S.M.H.4
  • 12
    • 70449532977 scopus 로고    scopus 로고
    • High-throughput liquid-liquid extraction and LCMSMS assay for determination of circulating 25(OH) vitamin D3 and D2 in the routine clinical laboratory
    • Hojskov C.S., Heckendorff L., Moller H.J. High-throughput liquid-liquid extraction and LCMSMS assay for determination of circulating 25(OH) vitamin D3 and D2 in the routine clinical laboratory. Clin Chim Acta 2010, 411:114-116.
    • (2010) Clin Chim Acta , vol.411 , pp. 114-116
    • Hojskov, C.S.1    Heckendorff, L.2    Moller, H.J.3
  • 13
    • 18144364293 scopus 로고    scopus 로고
    • Determination of 25-hydroxyvitamin D in human plasma using high-performance liquid chromatography-tandem mass spectrometry
    • Tsugawa N., Suhara Y., Kamao M., Okano T. Determination of 25-hydroxyvitamin D in human plasma using high-performance liquid chromatography-tandem mass spectrometry. Anal Chem 2005, 77:3001-3007.
    • (2005) Anal Chem , vol.77 , pp. 3001-3007
    • Tsugawa, N.1    Suhara, Y.2    Kamao, M.3    Okano, T.4
  • 14
    • 77950940177 scopus 로고    scopus 로고
    • Measurement of 25-OH-vitamin D in human serum using liquid chromatography-tandem mass spectrometry with comparison to radioimmunoassay and automated immunoassay
    • van den Ouweland J.M.W., Beijers A.M., Demacker P.N.M., van Daal H. Measurement of 25-OH-vitamin D in human serum using liquid chromatography-tandem mass spectrometry with comparison to radioimmunoassay and automated immunoassay. J Chromatogr B 2010, 878:1163-1168.
    • (2010) J Chromatogr B , vol.878 , pp. 1163-1168
    • van den Ouweland, J.M.W.1    Beijers, A.M.2    Demacker, P.N.M.3    van Daal, H.4
  • 15
    • 3242762258 scopus 로고    scopus 로고
    • Candidate reference method for the quantification of circulating 25-hydroxyvitamin D3 by liquid chromatography-tandem mass spectrometry
    • Vogeser M., Kyriantsoulis A., Huber E., Kobold U. Candidate reference method for the quantification of circulating 25-hydroxyvitamin D3 by liquid chromatography-tandem mass spectrometry. Clin Chem 2004, 50:1415-1417.
    • (2004) Clin Chem , vol.50 , pp. 1415-1417
    • Vogeser, M.1    Kyriantsoulis, A.2    Huber, E.3    Kobold, U.4
  • 16
    • 66249110640 scopus 로고    scopus 로고
    • A simple automated solid-phase extraction procedure for measurement of 25-hydroxyvitamin D3 and D2 by liquid chromatography-mass spectrometry
    • Knox S., Harris J., Calton L., Wallace A.M. A simple automated solid-phase extraction procedure for measurement of 25-hydroxyvitamin D3 and D2 by liquid chromatography-mass spectrometry. Ann Clin Biochem 2009, 46:226-230.
    • (2009) Ann Clin Biochem , vol.46 , pp. 226-230
    • Knox, S.1    Harris, J.2    Calton, L.3    Wallace, A.M.4
  • 17
    • 33747637729 scopus 로고    scopus 로고
    • C-3 epimers can account for a significant proportion of total circulating 25-hydroxyvitamin D in infants, complicating accurate measurement and interpretation of vitamin D status
    • Singh R.J., Taylor R.L., Reddy G.S., Grebe S.K.G. C-3 epimers can account for a significant proportion of total circulating 25-hydroxyvitamin D in infants, complicating accurate measurement and interpretation of vitamin D status. J Clin Endocrinol Metab 2006, 91:3055-3061.
    • (2006) J Clin Endocrinol Metab , vol.91 , pp. 3055-3061
    • Singh, R.J.1    Taylor, R.L.2    Reddy, G.S.3    Grebe, S.K.G.4
  • 18
    • 41849136467 scopus 로고    scopus 로고
    • Measurement of 25-hydroxyvitamin D3 (25OHD3) and 25-hydroxyvitamin D2 (25OHD2) in human serum using liquid chromatography-tandem mass spectrometry and its comparison to immunoassay method
    • Chen H., McCoy L.F., Schleicher R.L., Pfeiffer C.M. Measurement of 25-hydroxyvitamin D3 (25OHD3) and 25-hydroxyvitamin D2 (25OHD2) in human serum using liquid chromatography-tandem mass spectrometry and its comparison to immunoassay method. Clin Chim Acta 2008, 391:6-12.
    • (2008) Clin Chim Acta , vol.391 , pp. 6-12
    • Chen, H.1    McCoy, L.F.2    Schleicher, R.L.3    Pfeiffer, C.M.4
  • 19
    • 84860588484 scopus 로고    scopus 로고
    • Determination of 25-mono-hydroxy-vitamin D2 and D3 in human plasma using a Symbiosis Pico system: ACN free on-line SPE-LC-MS-MS
    • available at:, Accessed on January 15, 2011.
    • Silbum M. Determination of 25-mono-hydroxy-vitamin D2 and D3 in human plasma using a Symbiosis Pico system: ACN free on-line SPE-LC-MS-MS. Spark application note 0053-080-01, The Application Book October 2010, available at:, Accessed on January 15, 2011. http://www.sparkholland.com.
    • (2010) Spark application note 0053-080-01, The Application Book
    • Silbum, M.1
  • 20
    • 84860593050 scopus 로고    scopus 로고
    • Quantitative analysis of 25-OH-D2 and 25-OH-D3 in plasma using LC-MS/MS
    • available at:, Accessed on January 15, 2011.
    • Chindarkarova B., Kozak M. Quantitative analysis of 25-OH-D2 and 25-OH-D3 in plasma using LC-MS/MS. Thermo Scientific Application note 485b 2010, available at:, Accessed on January 15, 2011. http://www.thermofisher.com.
    • (2010) Thermo Scientific Application note 485b
    • Chindarkarova, B.1    Kozak, M.2
  • 21
    • 77955842014 scopus 로고    scopus 로고
    • Accelerating high quality bioanalytical LC/MS/MS assays using fused-core columns
    • Badman E.R., Beardsley R.C., Liang Z., Bansal S. Accelerating high quality bioanalytical LC/MS/MS assays using fused-core columns. J Chromatogr B 2010, 878:2307-2313.
    • (2010) J Chromatogr B , vol.878 , pp. 2307-2313
    • Badman, E.R.1    Beardsley, R.C.2    Liang, Z.3    Bansal, S.4
  • 23
    • 75949096893 scopus 로고    scopus 로고
    • Performance of columns packed with the new shell Kinetex-C18 particles in gradient elution chromatography
    • Gritti F., Guiochon G. Performance of columns packed with the new shell Kinetex-C18 particles in gradient elution chromatography. J Chromatogr A 2010, 1217:1604-1615.
    • (2010) J Chromatogr A , vol.1217 , pp. 1604-1615
    • Gritti, F.1    Guiochon, G.2
  • 24
    • 77952672825 scopus 로고    scopus 로고
    • Comparative study of new shell-type, sub-2μm fully porous and monolith stationary phases, focusing on mass-transfer resistance
    • Olah E., Fekete S., Fekete J., Ganzler K. Comparative study of new shell-type, sub-2μm fully porous and monolith stationary phases, focusing on mass-transfer resistance. J Chromatogr A 2010, 1217:3642-3653.
    • (2010) J Chromatogr A , vol.1217 , pp. 3642-3653
    • Olah, E.1    Fekete, S.2    Fekete, J.3    Ganzler, K.4
  • 25
    • 78149495855 scopus 로고    scopus 로고
    • TM) column in practice, applied for small and large molecule separation
    • TM) column in practice, applied for small and large molecule separation. J Pharm Biomed Anal 2011, 54:482-490.
    • (2011) J Pharm Biomed Anal , vol.54 , pp. 482-490
    • Fekete, S.1    Ganzler, K.2    Fekete, J.3
  • 26
    • 84860551017 scopus 로고    scopus 로고
    • Ultra-fast LC/MS/MS analysis of 25-OH vitamin D2 and D3 from serum
    • available at:, Accessed on January 10, 2011.
    • Koerner P.J. Ultra-fast LC/MS/MS analysis of 25-OH vitamin D2 and D3 from serum. Phenomenex Technical note TN-1055 2010, available at:, Accessed on January 10, 2011. http://www.phenomenex.com.
    • (2010) Phenomenex Technical note TN-1055
    • Koerner, P.J.1
  • 27
    • 0037663202 scopus 로고    scopus 로고
    • Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS
    • Matuszewski B.K., Constanzer M.L., Chavez-Eng C.M. Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS. Anal Chem 2003, 75:3019-3030.
    • (2003) Anal Chem , vol.75 , pp. 3019-3030
    • Matuszewski, B.K.1    Constanzer, M.L.2    Chavez-Eng, C.M.3
  • 29
    • 73249127845 scopus 로고    scopus 로고
    • Development and validation of a liquid chromatography-tandem mass spectrometry assay for serum 25-hydroxyvitamin D2/D3 using a turbulent flow online extraction technology
    • Bunch D.R., Miller A.Y., Wang S. Development and validation of a liquid chromatography-tandem mass spectrometry assay for serum 25-hydroxyvitamin D2/D3 using a turbulent flow online extraction technology. Clin Chem Lab Med 2009, 47:1565-1572.
    • (2009) Clin Chem Lab Med , vol.47 , pp. 1565-1572
    • Bunch, D.R.1    Miller, A.Y.2    Wang, S.3
  • 30
    • 77950344862 scopus 로고    scopus 로고
    • Quantitation of 25-OH-vitamin D (25-OH-D) using liquid tandem mass spectrometry (LC-MS-MS)
    • Singh R. Quantitation of 25-OH-vitamin D (25-OH-D) using liquid tandem mass spectrometry (LC-MS-MS). Methods Molecular Biol 2010, 603:509-517.
    • (2010) Methods Molecular Biol , vol.603 , pp. 509-517
    • Singh, R.1
  • 31
    • 34247205904 scopus 로고    scopus 로고
    • Simultaneous determination of cyclosporine A, tacrolimus, and sirolimus in whole blood as well as mycophenolic acis in plasma using common pretreatment procedure
    • Bogusz M.J., Al Enazi E., Hassan H., Abdel-Jawaad J., Al Ruwaily J., Al Tufail M. Simultaneous determination of cyclosporine A, tacrolimus, and sirolimus in whole blood as well as mycophenolic acis in plasma using common pretreatment procedure. J Chromatogr B 2007, 850:471-480.
    • (2007) J Chromatogr B , vol.850 , pp. 471-480
    • Bogusz, M.J.1    Al Enazi, E.2    Hassan, H.3    Abdel-Jawaad, J.4    Al Ruwaily, J.5    Al Tufail, M.6
  • 32
    • 45849133058 scopus 로고    scopus 로고
    • Metabolic profiling of major vitamin D metabolites using Diel-Alders derivatization and ultra-performance liquid chromatography-tandem mass spectrometry
    • Aronov P.A., Hall L.M., Dettmer K., Stephensen C.B., Hammock B.D. Metabolic profiling of major vitamin D metabolites using Diel-Alders derivatization and ultra-performance liquid chromatography-tandem mass spectrometry. Anal Bioanal Chem 2008, 319:1917-1930.
    • (2008) Anal Bioanal Chem , vol.319 , pp. 1917-1930
    • Aronov, P.A.1    Hall, L.M.2    Dettmer, K.3    Stephensen, C.B.4    Hammock, B.D.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.