메뉴 건너뛰기




Volumn 38, Issue 10, 2011, Pages 5448-5458

Experimental verification of a real-time compensation functionality for dose changes due to target motion in scanned particle therapy

Author keywords

beam tracking; dose compensation; organ motion; particle therapy; real time

Indexed keywords

CARBON; PARTICLE BEAM TRACKING; TARGET TRACKING;

EID: 80053606508     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3633891     Document Type: Article
Times cited : (31)

References (38)
  • 1
    • 0028891524 scopus 로고
    • The 200-MeV proton therapy project at the Paul Scherrer Institute: Conceptual design and practical realization
    • 10.1118/1.597522
    • E. Pedroni, The 200-MeV proton therapy project at the Paul Scherrer Institute: Conceptual design and practical realization., Med. Phys. 22, 37-53 (1995). 10.1118/1.597522
    • (1995) Med. Phys. , vol.22 , pp. 37-53
    • Pedroni, E.1
  • 2
    • 77649090008 scopus 로고    scopus 로고
    • Heavy-ion tumor therapy: Physical and radiobiological benefits
    • 10.1103/RevModPhys.82.383
    • D. Schardt, T. Elssser, and D. Schulz-Ertner, Heavy-ion tumor therapy: Physical and radiobiological benefits., Rev. Mod. Phys. 82, 383-425 (2010). 10.1103/RevModPhys.82.383
    • (2010) Rev. Mod. Phys. , vol.82 , pp. 383-425
    • Schardt, D.1    Elssser, T.2    Schulz-Ertner, D.3
  • 3
    • 33947535720 scopus 로고    scopus 로고
    • Particle radiation therapy using proton and heavier ion beams
    • DOI 10.1200/JCO.2006.09.7816
    • D. Schulz-Ertner and H. Tsujii, Particle radiation therapy using proton and heavier ion beams., J. Clin. Oncol. 25, 953-964 (2007). 10.1200/JCO.2006.09. 7816 (Pubitemid 350002861)
    • (2007) Journal of Clinical Oncology , vol.25 , Issue.8 , pp. 953-964
    • Schulz-Ertner, D.1    Tsujii, H.2
  • 4
    • 70449114182 scopus 로고    scopus 로고
    • Effectiveness and safety of spot scanning proton radiation therapy for chordomas and chondrosarcomas of the skull base: First long-term report
    • 10.1016/j.ijrob2008.12.055
    • C. Ares, Effectiveness and safety of spot scanning proton radiation therapy for chordomas and chondrosarcomas of the skull base: First long-term report., Int. J. Radiat. Oncol., Biol., Phys. 75, 1111-1118 (2009). 10.1016/j.ijrobp.2008.12.055
    • (2009) Int. J. Radiat. Oncol., Biol., Phys. , vol.75 , pp. 1111-1118
    • Ares, C.1
  • 6
    • 77950329106 scopus 로고    scopus 로고
    • Particle therapy at the Heidelberg Ion Therapy Center (HIT)-integrated research-driven university-hospital-based radiation oncology service in Heidelberg, Germany
    • 10.1016/j.radonc.2010.02.016
    • S. E. Combs, O. Jakel, T. Haberer, and J. Debus, Particle therapy at the Heidelberg Ion Therapy Center (HIT)-integrated research-driven university-hospital-based radiation oncology service in Heidelberg, Germany., Radiother. Oncol. 95, 41-44 (2010). 10.1016/j.radonc.2010.02.016
    • (2010) Radiother. Oncol. , vol.95 , pp. 41-44
    • Combs, S.E.1    Jakel, O.2    Haberer, T.3    Debus, J.4
  • 7
    • 78149447076 scopus 로고    scopus 로고
    • Performance of the NIRS fast scanning system for heavy-ion radiotherapy
    • 10.1118/1.3501313
    • T. Furukawa, Performance of the NIRS fast scanning system for heavy-ion radiotherapy., Med. Phys. 37, 5672-5682 (2010). 10.1118/1.3501313
    • (2010) Med. Phys. , vol.37 , pp. 5672-5682
    • Furukawa, T.1
  • 8
    • 33745498454 scopus 로고    scopus 로고
    • Proton therapy
    • DOI 10.1088/0031-9155/51/13/R26, PII S0031915506027096, R26
    • A. R. Smith, Proton therapy., Phys. Med. Biol. 51, R491-R504 (2006). 10.1088/0031-9155/51/13/R26 (Pubitemid 43958629)
    • (2006) Physics in Medicine and Biology , vol.51 , Issue.13
    • Smith, A.R.1
  • 9
    • 73649128300 scopus 로고    scopus 로고
    • A case study in proton pencil-beam scanning delivery
    • 10.1016/j.ijrob2009.06.065
    • H. M. Kooy, A case study in proton pencil-beam scanning delivery., Int. J. Radiat. Oncol., Biol., Phys. 76, 624-630 (2010). 10.1016/j.ijrobp.2009.06.065
    • (2010) Int. J. Radiat. Oncol., Biol., Phys. , vol.76 , pp. 624-630
    • Kooy, H.M.1
  • 10
    • 0026504759 scopus 로고
    • Effects of respiratory motion on dose uniformity with a charged particle scanning method
    • 10.1088/0031-9155/37/1/016
    • M. H. Phillips, E. Pedroni, H. Blattmann, T. Boehringer, A. Coray, and S. Scheib, Effects of respiratory motion on dose uniformity with a charged particle scanning method., Phys. Med. Biol. 37, 223-233 (1992). 10.1088/0031-9155/37/1/016
    • (1992) Phys. Med. Biol. , vol.37 , pp. 223-233
    • Phillips, M.H.1    Pedroni, E.2    Blattmann, H.3    Boehringer, T.4    Coray, A.5    Scheib, S.6
  • 11
    • 42449147956 scopus 로고    scopus 로고
    • Quantification of interplay effects of scanned particle beams and moving targets
    • DOI 10.1088/0031-9155/53/9/003, PII S003191550865928X
    • C. Bert, S. O. Grzinger, and E. Rietzel, Quantification of interplay effects of scanned particle beams and moving targets., Phys. Med. Biol. 53, 2253-2265 (2008). 10.1088/0031-9155/53/9/003 (Pubitemid 351570909)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.9 , pp. 2253-2265
    • Bert, C.1    Grozinger, S.O.2    Rietzel, E.3
  • 12
    • 70349581605 scopus 로고    scopus 로고
    • Breathing interplay effects during proton beam scanning: Simulation and statistical analysis
    • 10.1088/0031-9155/54/14/N01
    • J. Seco, D. Robertson, A. Trofimov, and H. Paganetti, Breathing interplay effects during proton beam scanning: Simulation and statistical analysis., Phys. Med. Biol. 54, N283-N294 (2009). 10.1088/0031-9155/54/14/N01
    • (2009) Phys. Med. Biol. , vol.54
    • Seco, J.1    Robertson, D.2    Trofimov, A.3    Paganetti, H.4
  • 14
    • 61549092441 scopus 로고    scopus 로고
    • Gated irradiation with scanned particle beams
    • 10.1016/j.ijrob2008.11.014
    • C. Bert, A. Gemmel, N. Saito, and E. Rietzel, Gated irradiation with scanned particle beams., Int. J. Radiat. Oncol., Biol., Phys. 73, 1270-1275 (2009). 10.1016/j.ijrobp.2008.11.014
    • (2009) Int. J. Radiat. Oncol., Biol., Phys. , vol.73 , pp. 1270-1275
    • Bert, C.1    Gemmel, A.2    Saito, N.3    Rietzel, E.4
  • 15
    • 55649094218 scopus 로고    scopus 로고
    • Motion compensation with a scanned ion beam: A technical feasibility study
    • 10.1186/1748-717X-3-34
    • S. O. Grzinger, C. Bert, T. Haberer, G. Kraft, and E. Rietzel, Motion compensation with a scanned ion beam: a technical feasibility study., Radiat. Oncol. 3: 34 (2008). 10.1186/1748-717X-3-34
    • (2008) Radiat. Oncol. , vol.3 , Issue.34
    • Grzinger, S.O.1    Bert, C.2    Haberer, T.3    Kraft, G.4    Rietzel, E.5
  • 16
    • 36649034851 scopus 로고    scopus 로고
    • Target motion tracking with a scanned particle beam
    • DOI 10.1118/1.2815934
    • C. Bert, N. Saito, A. Schmidt, N. Chaudhri, D. Schardt, and E. Rietzel, Target motion tracking with a scanned particle beam., Med. Phys. 34, 4768-4771 (2007). 10.1118/1.2815934 (Pubitemid 350197715)
    • (2007) Medical Physics , vol.34 , Issue.12 , pp. 4768-4771
    • Bert, C.1    Saito, N.2    Schmidt, A.3    Chaudhri, N.4    Schardt, D.5    Rietzel, E.6
  • 17
    • 70449120374 scopus 로고    scopus 로고
    • Tumour tracking with scanned proton beams: Assessing the accuracy and practicalities
    • 10.1088/0031-9155/54/21/007
    • S. van de Water, R. Kreuger, S. Zenklusen, E. Hug, and A. J. Lomax, Tumour tracking with scanned proton beams: assessing the accuracy and practicalities., Phys. Med. Biol. 54, 6549-6563 (2009). 10.1088/0031-9155/54/21/ 007
    • (2009) Phys. Med. Biol. , vol.54 , pp. 6549-6563
    • Van De Water, S.1    Kreuger, R.2    Zenklusen, S.3    Hug, E.4    Lomax, A.J.5
  • 18
    • 69549099881 scopus 로고    scopus 로고
    • Speed and accuracy of a beam tracking system for treatment of moving targets with scanned ion beams
    • 10.1088/0031-9155/54/16/001
    • N. Saito, C. Bert, N. Chaudhri, A. Gemmel, D. Schardt, and E. Rietzel, Speed and accuracy of a beam tracking system for treatment of moving targets with scanned ion beams., Phys. Med. Biol. 54, 4849-4862 (2009). 10.1088/0031-9155/54/16/001
    • (2009) Phys. Med. Biol. , vol.54 , pp. 4849-4862
    • Saito, N.1    Bert, C.2    Chaudhri, N.3    Gemmel, A.4    Schardt, D.5    Rietzel, E.6
  • 19
    • 34548301441 scopus 로고    scopus 로고
    • 4D treatment planning for scanned ion beams
    • 10.1186/1748-717X-2-24
    • C. Bert and E. Rietzel, 4D treatment planning for scanned ion beams., Radiat. Oncol. 2: 24 (2007). 10.1186/1748-717X-2-24
    • (2007) Radiat. Oncol. , vol.2 , Issue.24
    • Bert, C.1    Rietzel, E.2
  • 20
    • 45949091490 scopus 로고    scopus 로고
    • Anatomical imaging for radiotherapy
    • DOI 10.1088/0031-9155/53/12/R01, PII S0031915508516988
    • P. M. Evans, Anatomical imaging for radiotherapy., Phys. Med. Biol. 53, R151-R191 (2008). 10.1088/0031-9155/53/12/R01 (Pubitemid 351892412)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.12
    • Evans, P.M.1
  • 21
    • 70349577486 scopus 로고    scopus 로고
    • Real-time motion-adaptive-optimization (MAO) in TomoTherapy
    • 10.1088/0031-9155/54/14/003
    • W. Lu, Real-time motion-adaptive-optimization (MAO) in TomoTherapy., Phys. Med. Biol. 54, 4373-4398 (2009). 10.1088/0031-9155/54/14/003
    • (2009) Phys. Med. Biol. , vol.54 , pp. 4373-4398
    • Lu, W.1
  • 22
    • 33644549665 scopus 로고    scopus 로고
    • Feasibility of a novel deformable image registration technique to facilitate classification, targeting, and monitoring of tumor and normal tissue
    • 10.1016/j.ijrob2005.10.027
    • K. K. Brock, L. A. Dawson, M. B. Sharpe, D. J. Moseley, and D. A. Jaffray, Feasibility of a novel deformable image registration technique to facilitate classification, targeting, and monitoring of tumor and normal tissue., Int. J. Radiat. Oncol. 64, 1245-1254 (2006). 10.1016/j.ijrobp.2005.10. 027
    • (2006) Int. J. Radiat. Oncol. , vol.64 , pp. 1245-1254
    • Brock, K.K.1    Dawson, L.A.2    Sharpe, M.B.3    Moseley, D.J.4    Jaffray, D.A.5
  • 23
    • 33750537455 scopus 로고    scopus 로고
    • Deformable registration of 4D computed tomography data
    • DOI 10.1118/1.2361077
    • E. Rietzel and G. T. Y. Chen, Deformable registration of 4D computed tomography data., Med. Phys. 33, 4423-4430 (2006). 10.1118/1.2361077 (Pubitemid 44673132)
    • (2006) Medical Physics , vol.33 , Issue.11 , pp. 4423-4430
    • Rietzel, E.1    Chen, G.T.Y.2
  • 24
    • 73649145491 scopus 로고    scopus 로고
    • Results of a multi-institution deformable registration accuracy study (MIDRAS)
    • 10.1016/j.ijrob2009.06.031
    • K. K. Brock, Results of a multi-institution deformable registration accuracy study (MIDRAS)., Int. J. Radiat. Oncol., Biol., Phys. 76, 583-596 (2010). 10.1016/j.ijrobp.2009.06.031
    • (2010) Int. J. Radiat. Oncol., Biol., Phys. , vol.76 , pp. 583-596
    • Brock, K.K.1
  • 25
    • 0033773556 scopus 로고    scopus 로고
    • Treatment planning for heavy-ion radiotherapy: Physical beam model and dose optimization
    • 10.1088/0031-9155/45/11/313
    • M. Krmer, O. Jkel, T. Haberer, G. Kraft, D. Schardt, and U. Weber, Treatment planning for heavy-ion radiotherapy: physical beam model and dose optimization., Phys. Med. Biol. 45, 3299-3317 (2000). 10.1088/0031-9155/45/11/ 313
    • (2000) Phys. Med. Biol. , vol.45 , pp. 3299-3317
    • Krmer, M.1    Jkel, O.2    Haberer, T.3    Kraft, G.4    Schardt, D.5    Weber, U.6
  • 26
    • 0345035258 scopus 로고    scopus 로고
    • A system for three-dimensional dosimetric verification of treatment plans in intensity-modulated radiotherapy with heavy ions
    • DOI 10.1118/1.598728
    • C. P. Karger, O. Jkel, and G. H. Hartmann, A system for three-dimensional dosimetric verification of treatment plans in intensity-modulated radiotherapy with heavy ions., Med. Phys. 26, 2125-2132 (1999). 10.1118/1.598728 (Pubitemid 29498666)
    • (1999) Medical Physics , vol.26 , Issue.10 , pp. 2125-2132
    • Karger, C.P.1    Jakel, O.2    Hartmann, G.H.3    Heeg, P.4
  • 27
    • 0032732178 scopus 로고    scopus 로고
    • Design and construction of a ripple filter for a smoothed depth dose distribution in conformal particle therapy
    • DOI 10.1088/0031-9155/44/11/306, PII S0031915599035290
    • U. Weber and G. Kraft, Design and construction of a ripple filter for a smoothed depth dose distribution in conformal particle therapy., Phys. Med. Biol. 44, 2765-2775 (1999). 10.1088/0031-9155/44/11/306 (Pubitemid 29529358)
    • (1999) Physics in Medicine and Biology , vol.44 , Issue.11 , pp. 2765-2775
    • Weber, U.1    Kraft, G.2
  • 30
    • 0000223087 scopus 로고
    • Properties of sufficiency and statistical tests
    • 10.1098/rspa.1937.0109
    • M. S. Bartlett, Properties of sufficiency and statistical tests., Proc. R. Soc. London Ser. A 160, 268-282 (1937). 10.1098/rspa.1937.0109
    • (1937) Proc. R. Soc. London Ser. A , vol.160 , pp. 268-282
    • Bartlett, M.S.1
  • 32
    • 77953962041 scopus 로고    scopus 로고
    • Deviations in delineated GTV caused by artefacts in 4DCT
    • 10.1016/j.radonc.2010.04.019
    • G. F. Persson, Deviations in delineated GTV caused by artefacts in 4DCT., Radiother. Oncol. 96, 61-66 (2010). 10.1016/j.radonc.2010.04.019
    • (2010) Radiother. Oncol. , vol.96 , pp. 61-66
    • Persson, G.F.1
  • 33
    • 33749616651 scopus 로고    scopus 로고
    • Improvement in banding artefacts in four-dimensional computed tomography for radiotherapy planning
    • DOI 10.1088/0031-9155/51/20/010, PII S003191550520386X, 010
    • S. Mori, M. Endo, and H. Asakura, Improvement in banding artefacts in four-dimensional computed tomography for radiotherapy planning., Phys. Med. Biol. 51, 5231-5244 (2006). 10.1088/0031-9155/51/20/010 (Pubitemid 44540128)
    • (2006) Physics in Medicine and Biology , vol.51 , Issue.20 , pp. 5231-5244
    • Mori, S.1    Endo, M.2    Asakura, H.3
  • 34
    • 38349112015 scopus 로고    scopus 로고
    • Variability of four-dimensional computed tomography patient models
    • 10.1016/j.ijrob2007.08.067
    • J. J. Sonke, J. Lebesque, and H. M. van, Variability of four-dimensional computed tomography patient models., Int. J. Radiat. Oncol. Biol. Phys. 70, 590-598 (2008). 10.1016/j.ijrobp.2007.08.067
    • (2008) Int. J. Radiat. Oncol. Biol. Phys. , vol.70 , pp. 590-598
    • Sonke, J.J.1    Lebesque, J.2    Van, H.M.3
  • 37
    • 34347390456 scopus 로고    scopus 로고
    • Accuracy of tumor motion compensation algorithm from a robotic respiratory tracking system: A simulation study
    • DOI 10.1118/1.2739811
    • Y. Seppenwoolde, R. I. Berbeco, S. Nishioka, H. Shirato, and B. Heijmen, Accuracy of tumor motion compensation algorithm from a robotic respiratory tracking system: a simulation study., Med. Phys. 34, 2774-2784 (2007). 10.1118/1.2739811 (Pubitemid 47019797)
    • (2007) Medical Physics , vol.34 , Issue.7 , pp. 2774-2784
    • Seppenwoolde, Y.1    Berbeco, R.I.2    Nishioka, S.3    Shirato, H.4    Heijmen, B.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.