메뉴 건너뛰기




Volumn 20, Issue 5, 2011, Pages 1109-1118

Development and characterization of multisite three-dimensional microprobes for deep brain stimulation and recording

Author keywords

3 D microprobe; Deep brain stimulation (DBS); microelectromechanical systems; microfabrication; multisite neural implants

Indexed keywords

C57BL/6 MICE; DEEP BRAIN STIMULATION; DELIVERY CAPACITY; ELECTRODE SITES; FABRICATED DEVICE; GOLD ELECTRODES; IMPEDANCE CHARACTERISTICS; IN-VITRO; LONG-TERM BEHAVIOR; MICRO ELECTRO MECHANICAL SYSTEM; MICRO-PROBES; MULTI-CHANNEL; MULTI-SITE; NEURAL STIMULATIONS; POTENTIAL APPLICATIONS; PRECISE CONTROL; RECORDING CHANNELS; SALINE SOLUTIONS; STABLE CHARACTERISTICS; STRESS TEST;

EID: 80053560937     PISSN: 10577157     EISSN: None     Source Type: Journal    
DOI: 10.1109/JMEMS.2011.2160934     Document Type: Article
Times cited : (11)

References (39)
  • 1
    • 1542616512 scopus 로고    scopus 로고
    • Deep brain stimulation of the subthalamic nucleus in Parkinson's Disease 1993-2003: Where are we 10 years on?
    • DOI 10.1080/02688690410001660427
    • K. Ashkan, B. Wallace, B. A. Bell, and A. L. Benabid, "Deep brain stimulation of the subthalamic nucleus in Parkinson's disease 1993-2003: Where are we 10 years on?" Br. J. Neurosurg., vol. 18, no. 1, pp. 19-34, Feb. 2004. (Pubitemid 38333662)
    • (2004) British Journal of Neurosurgery , vol.18 , Issue.1 , pp. 19-34
    • Ashkan, K.1    Wallace, B.2    Bell, B.A.3    Benabid, A.L.4
  • 3
    • 4544304333 scopus 로고    scopus 로고
    • Deep brain stimulation in the treatment of dyskinesia and dystonia
    • Jul.
    • H. Toda, C. Hamani, and A. Lozano, "Deep brain stimulation in the treatment of dyskinesia and dystonia," Neurosurg. Focus, vol. 17, no. 1, pp. 9-13, Jul. 2004.
    • (2004) Neurosurg. Focus , vol.17 , Issue.1 , pp. 9-13
    • Toda, H.1    Hamani, C.2    Lozano, A.3
  • 5
    • 5444229343 scopus 로고    scopus 로고
    • Deep brain stimulation for hyperkinetic disorders
    • Jul.
    • E. B. Montgomery, Jr., "Deep brain stimulation for hyperkinetic disorders," Neurosurg. Focus, vol. 17, no. 1, pp. 1-8, Jul. 2004.
    • (2004) Neurosurg. Focus , vol.17 , Issue.1 , pp. 1-8
    • Montgomery Jr., E.B.1
  • 7
    • 1942452930 scopus 로고    scopus 로고
    • Deep brain stimulation for the treatment of Parkinson's disease
    • DOI 10.1097/00004691-200401000-00003
    • J. Volkmann, "Deep brain stimulation for the treatment of Parkinson's disease," J. Clin. Neurophysiol., vol. 21, no. 1, pp. 6-17, Feb. 2004. (Pubitemid 38507109)
    • (2004) Journal of Clinical Neurophysiology , vol.21 , Issue.1 , pp. 6-17
    • Volkmann, J.1
  • 8
    • 0037056365 scopus 로고    scopus 로고
    • The impact on Parkinson's disease of electrical parameter settings in STN stimulation
    • Sep.
    • E. Moro, R. J. Esselink, J. Xie, M. Hommel, A. L. Benabid, and P. Pollak, "The impact on Parkinson's disease of electrical parameter settings in STN stimulation," Neurology, vol. 59, no. 5, pp. 706-713, Sep. 2002.
    • (2002) Neurology , vol.59 , Issue.5 , pp. 706-713
    • Moro, E.1    Esselink, R.J.2    Xie, J.3    Hommel, M.4    Benabid, A.L.5    Pollak, P.6
  • 9
    • 1942517467 scopus 로고    scopus 로고
    • How does deep brain stimulation work? Present understanding and future questions
    • DOI 10.1097/00004691-200401000-00006
    • C. C.McIntyre, M. Savasta, B. L.Walter, and J. L. Vitek, "How does deep brain stimulation work? Present understanding and future questions," J. Clin. Neurophysiol., vol. 21, no. 1, pp. 40-50, Jan./Feb. 2004. (Pubitemid 38507112)
    • (2004) Journal of Clinical Neurophysiology , vol.21 , Issue.1 , pp. 40-50
    • McIntyre, C.C.1    Savasta, M.2    Walter, B.L.3    Vitek, J.L.4
  • 10
    • 1542720540 scopus 로고    scopus 로고
    • Cellular effects of deep brain stimulation: Model-based analysis of activation and inhibition
    • DOI 10.1152/jn.00989.2003
    • C. C. McIntyre, W. M. Grill, D. L. Sherman, and N. V. Thakor, "Cellular effects of deep brain stimulation: Model-based analysis of activation and inhibition," J. Neurophysiol., vol. 91, no. 4, pp. 1457-1469, Apr. 2004. (Pubitemid 38339318)
    • (2004) Journal of Neurophysiology , vol.91 , Issue.4 , pp. 1457-1469
    • McIntyre, C.C.1    Grill, W.M.2    Sherman, D.L.3    Thakor, N.V.4
  • 11
    • 80053574477 scopus 로고    scopus 로고
    • [Online]. Available: www.medtronic.com
  • 12
    • 2442708539 scopus 로고    scopus 로고
    • Wireless implantable microsystems: High-density electronic interfaces to the nervous system
    • DOI 10.1109/JPROC.2003.820544, Biomedical Applications for Mems and Microfluidics
    • K. D. Wise, D. J. Anderson, J. F. Hetke, D. R. Kipke, and K. Najafi, "Wireless implantable microsystems: High-density electronic interfaces to the nervous system," Proc. IEEE, vol. 92, no. 1, pp. 76-97, Jan. 2004. (Pubitemid 40890773)
    • (2004) Proceedings of the IEEE , vol.92 , Issue.1 , pp. 76-97
    • Wise, K.D.1    Anderson, D.J.2    Hetke, J.F.3    Kipke, D.R.4    Najafi, K.5
  • 13
    • 0014816457 scopus 로고
    • An integrated circuit approach to extracellular microelectrodes
    • Jul.
    • K. D. Wise, J. B. Angell, and A. Starr, "An integrated circuit approach to extracellular microelectrodes," IEEE Trans. Biomed. Eng., vol. BME-17, no. 3, pp. 238-247, Jul. 1970.
    • (1970) IEEE Trans. Biomed. Eng. , vol.BME-17 , Issue.3 , pp. 238-247
    • Wise, K.D.1    Angell, J.B.2    Starr, A.3
  • 14
    • 0037203991 scopus 로고    scopus 로고
    • Design and fabrication of a high-density metal microelectrode array for neural recording
    • DOI 10.1016/S0924-4247(01)00766-X
    • C. Xu, W. Lemon, and C. Liu, "Design and fabrication of a high-density metal microelectrode array for neural recording," Sens. Actuators A, Phys., vol. 96, no. 1, pp. 78-85, Jan. 2002. (Pubitemid 34156505)
    • (2002) Sensors and Actuators, A: Physical , vol.96 , Issue.1 , pp. 78-85
    • Xu, C.1    Lemon, W.2    Liu, C.3
  • 15
    • 0030168086 scopus 로고    scopus 로고
    • Silicon-based microelectrodes for neurophysiology fabricated using a gold metallization/nitride passivation system
    • PII S1057715796050676
    • G. Ensell, D. J. Banks, D. J. Ewins, W. Balachandran, and P. R. Richards, "Silicon-based microelectrodes for neurophysiology fabricated using a gold metallization/nitride passivation system," J. Microelectromech. Syst., vol. 5, no. 2, pp. 117-121, Jun. 1996. (Pubitemid 126607078)
    • (1996) Journal of Microelectromechanical Systems , vol.5 , Issue.2 , pp. 117-121
    • Ensell, G.1    Banks, D.J.2    Ewins, D.J.3    Balachandran, W.4    Richards, P.R.5
  • 17
    • 0026926772 scopus 로고
    • Regeneration microelectrode array for peripheral nerve recording and stimulation
    • DOI 10.1109/10.256422
    • G. T. A. Kovacs, C. W. Storment, and J. M. Rosen, "Regeneration microelectrode array for peripheral nerve recording and stimulation," IEEE Trans. Biomed. Eng., vol. 39, no. 9, pp. 893-902, Sep. 1992. (Pubitemid 23121820)
    • (1992) IEEE Transactions on Biomedical Engineering , vol.39 , Issue.9 , pp. 893-902
    • Kovacs, G.T.A.1    Storment, C.W.2    Rosen, J.M.3
  • 21
    • 0001142970 scopus 로고
    • Glasscoated tungsten microelectrodes
    • Jun.
    • H. A. Baldwin, S. Frank, and J. Y. Lettvin, "Glasscoated tungsten microelectrodes," Science, vol. 148, no. 3676, pp. 1462-1463, Jun. 1965.
    • (1965) Science , vol.148 , Issue.3676 , pp. 1462-1463
    • Baldwin, H.A.1    Frank, S.2    Lettvin, J.Y.3
  • 24
    • 33645294123 scopus 로고    scopus 로고
    • Microelectrode array for chronic deep-brain microstimulation and recording
    • Apr.
    • D. McCreery, A. Lossinsky, V. Pikov, and X. Liu, "Microelectrode array for chronic deep-brain microstimulation and recording," IEEE Trans. Biomed. Eng., vol. 53, no. 4, pp. 726-737, Apr. 2006.
    • (2006) IEEE Trans. Biomed. Eng. , vol.53 , Issue.4 , pp. 726-737
    • McCreery, D.1    Lossinsky, A.2    Pikov, V.3    Liu, X.4
  • 25
    • 18744416955 scopus 로고    scopus 로고
    • Multielectrode microprobes for deep-brain stimulation fabricated with a customizable 3-D electroplating process
    • DOI 10.1109/TBME.2005.845225
    • P. S. Motta and J. W. Judy, "Multielectrode microprobes for deep-brain stimulation fabricated with a customizable 3-D electroplating process," IEEE Trans. Biomed. Eng., vol. 52, no. 5, pp. 923-933, May 2005. (Pubitemid 40675492)
    • (2005) IEEE Transactions on Biomedical Engineering , vol.52 , Issue.5 , pp. 923-933
    • Motta, P.S.1    Judy, J.W.2
  • 26
    • 0026882265 scopus 로고
    • Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
    • DOI 10.1109/10.141202
    • D. J. Edell, V. V. Toi, V. M. McNeil, and L. D. Clark, "Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex," IEEE Trans. Biomed. Eng., vol. 39, no. 6, pp. 635-643, Jun. 1992. (Pubitemid 23002705)
    • (1992) IEEE Transactions on Biomedical Engineering , vol.39 , Issue.6 , pp. 635-643
    • Edell, D.J.1    Vo Van Toi2    McNeil, V.M.3    Clark, L.D.4
  • 27
    • 70350132007 scopus 로고    scopus 로고
    • Insertion shuttle with carboxyl terminated self-assembled monolayer coatings for implanting flexible polymer neural probes in the brain
    • Nov.
    • T. D. Y. Kozai and D. R. Kipke, "Insertion shuttle with carboxyl terminated self-assembled monolayer coatings for implanting flexible polymer neural probes in the brain," J. Neurosci. Methods, vol. 184, no. 2, pp. 199-205, Nov. 2009.
    • (2009) J. Neurosci. Methods , vol.184 , Issue.2 , pp. 199-205
    • Kozai, T.D.Y.1    Kipke, D.R.2
  • 30
    • 33846585141 scopus 로고    scopus 로고
    • Flexible polyimide microelectrode array for in vivo recordings and current source density analysis
    • DOI 10.1016/j.bios.2006.08.035, PII S0956566306004039
    • K. C. Cheung, P. Renaud, H. Tanila, and K. Djupsund, "Flexible polyimide micro-electrode array for in vivo recordings and current source density analysis," Biosens. Bioelectron., vol. 22, no. 8, pp. 1783-1790, Mar. 2007. (Pubitemid 46185980)
    • (2007) Biosensors and Bioelectronics , vol.22 , Issue.8 , pp. 1783-1790
    • Cheung, K.C.1    Renaud, P.2    Tanila, H.3    Djupsund, K.4
  • 31
    • 0001574753 scopus 로고    scopus 로고
    • Micromachined polyimide-based devices for flexible neural interfaces
    • Apr.
    • T. Stieglitz, H. Beutel, M. Schuettler, and J.-U. Meyer, "Micromachined polyimide-based devices for flexible neural interfaces," Biomed. Microdevices, vol. 2, no. 4, pp. 283-294, Apr. 2000.
    • (2000) Biomed. Microdevices , vol.2 , Issue.4 , pp. 283-294
    • Stieglitz, T.1    Beutel, H.2    Schuettler, M.3    Meyer, J.-U.4
  • 32
    • 13444252507 scopus 로고    scopus 로고
    • Choosing electrodes for deep brain stimulation experiments- electrochemical considerations
    • DOI 10.1016/j.jneumeth.2004.09.001
    • J. Gimsa, B. Habel, U. Schreiber, U. Rienen, U. Strauss, and U. Gimsa, "Choosing electrodes for deep brain stimulation experiments-electrochemical considerations," J. Neurosci. Methods, vol. 142, no. 2, pp. 251-265, Mar. 2005. (Pubitemid 40215459)
    • (2005) Journal of Neuroscience Methods , vol.142 , Issue.2 , pp. 251-265
    • Gimsa, J.1    Habel, B.2    Schreiber, U.3    Rienen, U.V.4    Strauss, U.5    Gimsa, U.6
  • 33
    • 0022905846 scopus 로고
    • 2 DISCHARGES
    • M. Kogoma and G. Turban, "Mechanism of etching and of surface modification of polyimide in RF and LF SF6?O2 discharges," Plasma Chem. Plasma Process., vol. 6, no. 4, pp. 349-380, Dec. 1986. (Pubitemid 17497715)
    • (1986) Plasma Chemistry and Plasma Processing , vol.6 , Issue.4 , pp. 349-380
    • Kogoma, M.1    Turban, G.2
  • 35
    • 0024027087 scopus 로고
    • Charge injection limits of activated iridium oxide electrodes with 0.2 ms pulses in bicarbonate buffered saline
    • Jun.
    • X. Beebe and T. L. Rose, "Charge injection limits of activated iridium oxide electrodes with 0.2 ms pulses in bicarbonate buffered saline," IEEE Trans. Biomed. Eng., vol. 35, no. 6, pp. 494-495, Jun. 1988.
    • (1988) IEEE Trans. Biomed. Eng. , vol.35 , Issue.6 , pp. 494-495
    • Beebe, X.1    Rose, T.L.2
  • 36
    • 31544432573 scopus 로고    scopus 로고
    • Microfabricated cylindrical multielectrodes for neural stimulation
    • DOI 10.1109/TBME.2005.862552
    • S. Snow, S. C. Jacobsen, D. L. Wells, and K. W. Horch, "Microfabricated cylindrical multielectrodes for neural stimulation," IEEE Trans. Biomed. Eng., vol. 53, no. 2, pp. 320-326, Feb. 2006. (Pubitemid 43162420)
    • (2006) IEEE Transactions on Biomedical Engineering , vol.53 , Issue.2 , pp. 320-326
    • Snow, S.1    Jacobsen, S.C.2    Wells, D.L.3    Horch, K.W.4
  • 37
    • 84996169082 scopus 로고
    • Electrodeposition of the platinum group metals
    • F. H. Reid, "Electrodeposition of the platinum group metals," Metallurgical Rev., vol. 8, no. 30, pp. 167-211, 1963.
    • (1963) Metallurgical Rev. , vol.8 , Issue.30 , pp. 167-211
    • Reid, F.H.1
  • 38
    • 11344276846 scopus 로고    scopus 로고
    • Model of frequent, recurrent, and spontaneous seizures in the intact mouse hippocampus
    • DOI 10.1002/hipo.20007
    • M. Derchansky, E. Shahar, R. A.Wennberg, M. Samoilova, S. S. Jahromi, P. A. Abdemalik, L. Zhang, and P. L. Carlen, "Model of frequent, recurrent and spontaneous seizures in the intact mouse hippocampus," Hippocampus, vol. 14, no. 8, pp. 935-947, Apr. 2004. (Pubitemid 40073655)
    • (2004) Hippocampus , vol.14 , Issue.8 , pp. 935-947
    • Derchansky, M.1    Shahar, E.2    Wennberg, R.A.3    Samoilova, M.4    Jahromi, S.S.5    Abdelmalik, P.A.6    Zhang, L.7    Carlen, P.L.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.