-
1
-
-
1542616512
-
Deep brain stimulation of the subthalamic nucleus in Parkinson's Disease 1993-2003: Where are we 10 years on?
-
DOI 10.1080/02688690410001660427
-
K. Ashkan, B. Wallace, B. A. Bell, and A. L. Benabid, "Deep brain stimulation of the subthalamic nucleus in Parkinson's disease 1993-2003: Where are we 10 years on?" Br. J. Neurosurg., vol. 18, no. 1, pp. 19-34, Feb. 2004. (Pubitemid 38333662)
-
(2004)
British Journal of Neurosurgery
, vol.18
, Issue.1
, pp. 19-34
-
-
Ashkan, K.1
Wallace, B.2
Bell, B.A.3
Benabid, A.L.4
-
2
-
-
0037378689
-
Limitations of current Parkinson's disease therapy
-
DOI 10.1002/ana.10513
-
O. Rascol, P. Payoux, F. Ory, J. J. Ferreira, C. Brefel-Courbon, and J. L. Montastruc, "Limitations of current Parkinson's disease therapy," Ann. Neurol., vol. 53, no. S3, pp. S3-S15, Jan. 2003. (Pubitemid 36368558)
-
(2003)
Annals of Neurology
, vol.53
, Issue.SUPPL. 3
-
-
Rascol, O.1
Payoux, P.2
Ory, F.3
Ferreira, J.J.4
Brefel-Courbon, C.5
Montastruc, J.-L.6
Schapira7
Jenner8
Tatton9
Stocchi10
Kordower11
Olanow12
Isacson13
Beal14
-
3
-
-
4544304333
-
Deep brain stimulation in the treatment of dyskinesia and dystonia
-
Jul.
-
H. Toda, C. Hamani, and A. Lozano, "Deep brain stimulation in the treatment of dyskinesia and dystonia," Neurosurg. Focus, vol. 17, no. 1, pp. 9-13, Jul. 2004.
-
(2004)
Neurosurg. Focus
, vol.17
, Issue.1
, pp. 9-13
-
-
Toda, H.1
Hamani, C.2
Lozano, A.3
-
4
-
-
0037941534
-
Long-term electrical capsular stimulation in patients with obsessive-compulsive disorder
-
B. J. Nuttin, L. A. Gabriels, P. R. Cosyns, B. A.Meyerson, S. Andreewitch, S. G. Sunaert, A. F. Maes, P. J. Dupont, J. M. Gybels, F. Gielen, and H. G. Demeulemeester, "Long-term electrical capsular stimulation in patients with obsessive-compulsive disorder," Neurosurgery, vol. 52, no. 6, pp. 1263-1274, Jun. 2003. (Pubitemid 36666941)
-
(2003)
Neurosurgery
, vol.52
, Issue.6
, pp. 1263-1274
-
-
Nuttin, B.J.1
Gabriels, L.A.2
Cosyns, P.R.3
Meyerson, B.A.4
Andreewitch, S.5
Sunaert, S.G.6
Maes, A.F.7
Dupont, P.J.8
Gybels, J.M.9
Gielen, F.10
Demeulemeester, H.G.11
Van Kuyck, K.12
Kopell, B.13
Kelly, P.J.14
Velasco, F.15
Benabid, A.L.16
Malone, D.17
Rezai, A.R.18
-
5
-
-
5444229343
-
Deep brain stimulation for hyperkinetic disorders
-
Jul.
-
E. B. Montgomery, Jr., "Deep brain stimulation for hyperkinetic disorders," Neurosurg. Focus, vol. 17, no. 1, pp. 1-8, Jul. 2004.
-
(2004)
Neurosurg. Focus
, vol.17
, Issue.1
, pp. 1-8
-
-
Montgomery Jr., E.B.1
-
6
-
-
14644402983
-
Deep brain stimulation for treatment-resistant depression
-
DOI 10.1016/j.neuron.2005.02.014
-
H. S. Mayberg, A. M. Lozano, V. Voon, H. E. McNeely, D. Seminowicz, C. Hamani, J. M. Schwalb, and S. H. Kennedy, "Deep brain stimulation for treatment-resistant depression," Neuron, vol. 45, no. 5, pp. 651-660, Mar. 2005. (Pubitemid 40320700)
-
(2005)
Neuron
, vol.45
, Issue.5
, pp. 651-660
-
-
Mayberg, H.S.1
Lozano, A.M.2
Voon, V.3
McNeely, H.E.4
Seminowicz, D.5
Hamani, C.6
Schwalb, J.M.7
Kennedy, S.H.8
-
7
-
-
1942452930
-
Deep brain stimulation for the treatment of Parkinson's disease
-
DOI 10.1097/00004691-200401000-00003
-
J. Volkmann, "Deep brain stimulation for the treatment of Parkinson's disease," J. Clin. Neurophysiol., vol. 21, no. 1, pp. 6-17, Feb. 2004. (Pubitemid 38507109)
-
(2004)
Journal of Clinical Neurophysiology
, vol.21
, Issue.1
, pp. 6-17
-
-
Volkmann, J.1
-
8
-
-
0037056365
-
The impact on Parkinson's disease of electrical parameter settings in STN stimulation
-
Sep.
-
E. Moro, R. J. Esselink, J. Xie, M. Hommel, A. L. Benabid, and P. Pollak, "The impact on Parkinson's disease of electrical parameter settings in STN stimulation," Neurology, vol. 59, no. 5, pp. 706-713, Sep. 2002.
-
(2002)
Neurology
, vol.59
, Issue.5
, pp. 706-713
-
-
Moro, E.1
Esselink, R.J.2
Xie, J.3
Hommel, M.4
Benabid, A.L.5
Pollak, P.6
-
9
-
-
1942517467
-
How does deep brain stimulation work? Present understanding and future questions
-
DOI 10.1097/00004691-200401000-00006
-
C. C.McIntyre, M. Savasta, B. L.Walter, and J. L. Vitek, "How does deep brain stimulation work? Present understanding and future questions," J. Clin. Neurophysiol., vol. 21, no. 1, pp. 40-50, Jan./Feb. 2004. (Pubitemid 38507112)
-
(2004)
Journal of Clinical Neurophysiology
, vol.21
, Issue.1
, pp. 40-50
-
-
McIntyre, C.C.1
Savasta, M.2
Walter, B.L.3
Vitek, J.L.4
-
10
-
-
1542720540
-
Cellular effects of deep brain stimulation: Model-based analysis of activation and inhibition
-
DOI 10.1152/jn.00989.2003
-
C. C. McIntyre, W. M. Grill, D. L. Sherman, and N. V. Thakor, "Cellular effects of deep brain stimulation: Model-based analysis of activation and inhibition," J. Neurophysiol., vol. 91, no. 4, pp. 1457-1469, Apr. 2004. (Pubitemid 38339318)
-
(2004)
Journal of Neurophysiology
, vol.91
, Issue.4
, pp. 1457-1469
-
-
McIntyre, C.C.1
Grill, W.M.2
Sherman, D.L.3
Thakor, N.V.4
-
11
-
-
80053574477
-
-
[Online]. Available: www.medtronic.com
-
-
-
-
12
-
-
2442708539
-
Wireless implantable microsystems: High-density electronic interfaces to the nervous system
-
DOI 10.1109/JPROC.2003.820544, Biomedical Applications for Mems and Microfluidics
-
K. D. Wise, D. J. Anderson, J. F. Hetke, D. R. Kipke, and K. Najafi, "Wireless implantable microsystems: High-density electronic interfaces to the nervous system," Proc. IEEE, vol. 92, no. 1, pp. 76-97, Jan. 2004. (Pubitemid 40890773)
-
(2004)
Proceedings of the IEEE
, vol.92
, Issue.1
, pp. 76-97
-
-
Wise, K.D.1
Anderson, D.J.2
Hetke, J.F.3
Kipke, D.R.4
Najafi, K.5
-
13
-
-
0014816457
-
An integrated circuit approach to extracellular microelectrodes
-
Jul.
-
K. D. Wise, J. B. Angell, and A. Starr, "An integrated circuit approach to extracellular microelectrodes," IEEE Trans. Biomed. Eng., vol. BME-17, no. 3, pp. 238-247, Jul. 1970.
-
(1970)
IEEE Trans. Biomed. Eng.
, vol.BME-17
, Issue.3
, pp. 238-247
-
-
Wise, K.D.1
Angell, J.B.2
Starr, A.3
-
14
-
-
0037203991
-
Design and fabrication of a high-density metal microelectrode array for neural recording
-
DOI 10.1016/S0924-4247(01)00766-X
-
C. Xu, W. Lemon, and C. Liu, "Design and fabrication of a high-density metal microelectrode array for neural recording," Sens. Actuators A, Phys., vol. 96, no. 1, pp. 78-85, Jan. 2002. (Pubitemid 34156505)
-
(2002)
Sensors and Actuators, A: Physical
, vol.96
, Issue.1
, pp. 78-85
-
-
Xu, C.1
Lemon, W.2
Liu, C.3
-
15
-
-
0030168086
-
Silicon-based microelectrodes for neurophysiology fabricated using a gold metallization/nitride passivation system
-
PII S1057715796050676
-
G. Ensell, D. J. Banks, D. J. Ewins, W. Balachandran, and P. R. Richards, "Silicon-based microelectrodes for neurophysiology fabricated using a gold metallization/nitride passivation system," J. Microelectromech. Syst., vol. 5, no. 2, pp. 117-121, Jun. 1996. (Pubitemid 126607078)
-
(1996)
Journal of Microelectromechanical Systems
, vol.5
, Issue.2
, pp. 117-121
-
-
Ensell, G.1
Banks, D.J.2
Ewins, D.J.3
Balachandran, W.4
Richards, P.R.5
-
16
-
-
0024691808
-
Batch-fabricated thin-film electrodes for stimulation of the central auditory system
-
DOI 10.1109/10.32101
-
D. J. Anderson, K. Najafi, S. J. Tanghe, D. A. Evans, K. L. Levy, J. F. Hetke, X. Xue, J. J. Zappia, and K. D. Wise, "Batch fabricated thin film electrodes for stimulation of the central auditory system," IEEE Trans. Biomed. Eng., vol. 36, no. 7, pp. 693-704, Jul. 1989. (Pubitemid 19172391)
-
(1989)
IEEE Transactions on Biomedical Engineering
, vol.36
, Issue.7
, pp. 693-704
-
-
Anderson, D.J.1
Najafi, K.2
Tanghe, S.J.3
Evans, D.A.4
Levy, K.L.5
Hetke, J.F.6
Xue, X.7
Zappia, J.J.8
Wise, K.D.9
-
17
-
-
0026926772
-
Regeneration microelectrode array for peripheral nerve recording and stimulation
-
DOI 10.1109/10.256422
-
G. T. A. Kovacs, C. W. Storment, and J. M. Rosen, "Regeneration microelectrode array for peripheral nerve recording and stimulation," IEEE Trans. Biomed. Eng., vol. 39, no. 9, pp. 893-902, Sep. 1992. (Pubitemid 23121820)
-
(1992)
IEEE Transactions on Biomedical Engineering
, vol.39
, Issue.9
, pp. 893-902
-
-
Kovacs, G.T.A.1
Storment, C.W.2
Rosen, J.M.3
-
18
-
-
0035095902
-
Flexible polyimide-based intracortical electrode arrays with bioactive capability
-
Mar.
-
P. J. Rousche, D. S. Pellinen, D. P. Pivin, Jr., J. C. Williams, R. J. Vetter, and D. R. Kipke, "Flexible polyimide-based intracortical electrode arrays with bioactive capability," IEEE Trans. Biomed. Eng., vol. 48, no. 3, pp. 361-371, Mar. 2001.
-
(2001)
IEEE Trans. Biomed. Eng.
, vol.48
, Issue.3
, pp. 361-371
-
-
Rousche, P.J.1
Pellinen, D.S.2
Pivin Jr., D.P.3
Williams, J.C.4
Vetter, R.J.5
Kipke, D.R.6
-
19
-
-
0036287837
-
Advanced neural implants using thin-film polymers
-
May
-
D. R. Kipke, D. S. Pellinen, and R. J. Vetter, "Advanced neural implants using thin-film polymers," in Proc. IEEE Int. Symp. Circuits Syst., May 2002, vol. 4, pp. 173-176.
-
(2002)
Proc. IEEE Int. Symp. Circuits Syst.
, vol.4
, pp. 173-176
-
-
Kipke, D.R.1
Pellinen, D.S.2
Vetter, R.J.3
-
20
-
-
0036645870
-
A 32-site neural recording probe fabricated by DRIE of SOI substrates
-
DOI 10.1088/0960-1317/12/4/312, PII S0960131702325476
-
P. Norlin, M. Kindlundh, A. Mouroux, K. Yoshida, and U. G. Hofmann, "A 32-site neural recording probe fabricated by DRIE of SOI substrates," J. Micromech. Microeng., vol. 12, no. 4, pp. 414-419, Jul. 2002. (Pubitemid 34830217)
-
(2002)
Journal of Micromechanics and Microengineering
, vol.12
, Issue.4
, pp. 414-419
-
-
Norlin, P.1
Kindlundh, M.2
Mouroux, A.3
Yoshida, K.4
Hofmann, U.G.5
-
21
-
-
0001142970
-
Glasscoated tungsten microelectrodes
-
Jun.
-
H. A. Baldwin, S. Frank, and J. Y. Lettvin, "Glasscoated tungsten microelectrodes," Science, vol. 148, no. 3676, pp. 1462-1463, Jun. 1965.
-
(1965)
Science
, vol.148
, Issue.3676
, pp. 1462-1463
-
-
Baldwin, H.A.1
Frank, S.2
Lettvin, J.Y.3
-
22
-
-
35548983149
-
Multisite microelectrodes for use in human deep brain stimulation
-
DOI 10.1109/MMB.2006.251551, 4281369, Proceedings of 2006 International Conference on Microtechnologies in Medicine and Biology
-
U. G. Hofmann, C. K. E. Moll, G. Engler, A. K. Engel, M. Bär, D. Höhl, U. Thomas, and P. Detemple, "Multisite microelectrodes for use in human deep brain stimulation," in Proc. Int. Conf. Microtechnol. Med. Biol., May 2006, pp. 284-287. (Pubitemid 350017413)
-
(2006)
Proceedings of 2006 International Conference on Microtechnologies in Medicine and Biology
, pp. 284-287
-
-
Hofmann, U.G.1
Moll, C.K.E.2
Engler, G.3
Engel, A.K.4
Bar, M.5
Hohl, D.6
Thomas, U.7
Detemple, P.8
-
23
-
-
34548794012
-
A simple microelectrode bundle for deep brain recordings
-
DOI 10.1109/CNE.2007.369625, 4227230, Proceedings of the 3rd International IEEE EMBS Conference on Neural Engineering
-
T. Gritsun, S. Vogt, G. Engler, C. K. E. Moll, A. K. Engel, S. Kondra, L. Ramrath, and U. G. Hofmann, "A simple microelectrode bundle for deep brain recordings," in Proc. 3rd Int. IEEE EMBS Conf. Neural Eng., May 2007, pp. 114-117. (Pubitemid 47432175)
-
(2007)
Proceedings of the 3rd International IEEE EMBS Conference on Neural Engineering
, pp. 114-117
-
-
Gritsun, T.1
Vogt, S.2
Engler, G.3
Moll, C.K.E.4
Engel, A.K.5
Kondra, S.6
Ramrath, L.7
Hofmann, U.G.8
-
24
-
-
33645294123
-
Microelectrode array for chronic deep-brain microstimulation and recording
-
Apr.
-
D. McCreery, A. Lossinsky, V. Pikov, and X. Liu, "Microelectrode array for chronic deep-brain microstimulation and recording," IEEE Trans. Biomed. Eng., vol. 53, no. 4, pp. 726-737, Apr. 2006.
-
(2006)
IEEE Trans. Biomed. Eng.
, vol.53
, Issue.4
, pp. 726-737
-
-
McCreery, D.1
Lossinsky, A.2
Pikov, V.3
Liu, X.4
-
25
-
-
18744416955
-
Multielectrode microprobes for deep-brain stimulation fabricated with a customizable 3-D electroplating process
-
DOI 10.1109/TBME.2005.845225
-
P. S. Motta and J. W. Judy, "Multielectrode microprobes for deep-brain stimulation fabricated with a customizable 3-D electroplating process," IEEE Trans. Biomed. Eng., vol. 52, no. 5, pp. 923-933, May 2005. (Pubitemid 40675492)
-
(2005)
IEEE Transactions on Biomedical Engineering
, vol.52
, Issue.5
, pp. 923-933
-
-
Motta, P.S.1
Judy, J.W.2
-
26
-
-
0026882265
-
Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
-
DOI 10.1109/10.141202
-
D. J. Edell, V. V. Toi, V. M. McNeil, and L. D. Clark, "Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex," IEEE Trans. Biomed. Eng., vol. 39, no. 6, pp. 635-643, Jun. 1992. (Pubitemid 23002705)
-
(1992)
IEEE Transactions on Biomedical Engineering
, vol.39
, Issue.6
, pp. 635-643
-
-
Edell, D.J.1
Vo Van Toi2
McNeil, V.M.3
Clark, L.D.4
-
27
-
-
70350132007
-
Insertion shuttle with carboxyl terminated self-assembled monolayer coatings for implanting flexible polymer neural probes in the brain
-
Nov.
-
T. D. Y. Kozai and D. R. Kipke, "Insertion shuttle with carboxyl terminated self-assembled monolayer coatings for implanting flexible polymer neural probes in the brain," J. Neurosci. Methods, vol. 184, no. 2, pp. 199-205, Nov. 2009.
-
(2009)
J. Neurosci. Methods
, vol.184
, Issue.2
, pp. 199-205
-
-
Kozai, T.D.Y.1
Kipke, D.R.2
-
28
-
-
77951008017
-
3-D microfabricated electrodes for targeted deep brain stimulation
-
Sep.
-
N. Laotaveerungrueng, C.-H. Lin,G. McCallum, S. Rajgopal, C. P. Steiner, A. R. Rezai, and M. Mehregany, "3-D microfabricated electrodes for targeted deep brain stimulation," in Proc. 31st Annu. Int. IEEE EMBS Conf., Sep. 2009, pp. 6943-6946.
-
(2009)
Proc. 31st Annu. Int. IEEE EMBS Conf.
, pp. 6943-6946
-
-
Laotaveerungrueng, N.1
Lin, C.-H.2
McCallum, G.3
Rajgopal, S.4
Steiner, C.P.5
Rezai, A.R.6
Mehregany, M.7
-
29
-
-
78650810613
-
3D microprobes for deep brain stimulation and recording
-
Sep.
-
A. A. Fomani, M. Moradi, S. Assaf, and R. R. Mansour, "3D microprobes for deep brain stimulation and recording," in Proc. 32nd Annu. Int. IEEE EMBS Conf., Sep. 2010, pp. 1808-1811.
-
(2010)
Proc. 32nd Annu. Int. IEEE EMBS Conf.
, pp. 1808-1811
-
-
Fomani, A.A.1
Moradi, M.2
Assaf, S.3
Mansour, R.R.4
-
30
-
-
33846585141
-
Flexible polyimide microelectrode array for in vivo recordings and current source density analysis
-
DOI 10.1016/j.bios.2006.08.035, PII S0956566306004039
-
K. C. Cheung, P. Renaud, H. Tanila, and K. Djupsund, "Flexible polyimide micro-electrode array for in vivo recordings and current source density analysis," Biosens. Bioelectron., vol. 22, no. 8, pp. 1783-1790, Mar. 2007. (Pubitemid 46185980)
-
(2007)
Biosensors and Bioelectronics
, vol.22
, Issue.8
, pp. 1783-1790
-
-
Cheung, K.C.1
Renaud, P.2
Tanila, H.3
Djupsund, K.4
-
31
-
-
0001574753
-
Micromachined polyimide-based devices for flexible neural interfaces
-
Apr.
-
T. Stieglitz, H. Beutel, M. Schuettler, and J.-U. Meyer, "Micromachined polyimide-based devices for flexible neural interfaces," Biomed. Microdevices, vol. 2, no. 4, pp. 283-294, Apr. 2000.
-
(2000)
Biomed. Microdevices
, vol.2
, Issue.4
, pp. 283-294
-
-
Stieglitz, T.1
Beutel, H.2
Schuettler, M.3
Meyer, J.-U.4
-
32
-
-
13444252507
-
Choosing electrodes for deep brain stimulation experiments- electrochemical considerations
-
DOI 10.1016/j.jneumeth.2004.09.001
-
J. Gimsa, B. Habel, U. Schreiber, U. Rienen, U. Strauss, and U. Gimsa, "Choosing electrodes for deep brain stimulation experiments-electrochemical considerations," J. Neurosci. Methods, vol. 142, no. 2, pp. 251-265, Mar. 2005. (Pubitemid 40215459)
-
(2005)
Journal of Neuroscience Methods
, vol.142
, Issue.2
, pp. 251-265
-
-
Gimsa, J.1
Habel, B.2
Schreiber, U.3
Rienen, U.V.4
Strauss, U.5
Gimsa, U.6
-
33
-
-
0022905846
-
2 DISCHARGES
-
M. Kogoma and G. Turban, "Mechanism of etching and of surface modification of polyimide in RF and LF SF6?O2 discharges," Plasma Chem. Plasma Process., vol. 6, no. 4, pp. 349-380, Dec. 1986. (Pubitemid 17497715)
-
(1986)
Plasma Chemistry and Plasma Processing
, vol.6
, Issue.4
, pp. 349-380
-
-
Kogoma, M.1
Turban, G.2
-
34
-
-
0034908983
-
Electrodeposited iridium oxide for neural stimulation and recording electrodes
-
DOI 10.1109/7333.918271, PII 1534432001017752
-
R. D. Meyer, S. F. Cogan, T. H. Nguyen, and R. D. Rauh, "Electrodeposited iridium oxide for neural stimulation and recording electrodes," IEEE Trans. Neural Syst. Rehabil. Eng., vol. 9, no. 1, pp. 2-11, Mar. 2001. (Pubitemid 32724960)
-
(2001)
IEEE Transactions on Neural Systems and Rehabilitation Engineering
, vol.9
, Issue.1
, pp. 2-11
-
-
Meyer, R.D.1
Cogan, S.F.2
Nguyen, T.H.3
Rauh, R.D.4
-
35
-
-
0024027087
-
Charge injection limits of activated iridium oxide electrodes with 0.2 ms pulses in bicarbonate buffered saline
-
Jun.
-
X. Beebe and T. L. Rose, "Charge injection limits of activated iridium oxide electrodes with 0.2 ms pulses in bicarbonate buffered saline," IEEE Trans. Biomed. Eng., vol. 35, no. 6, pp. 494-495, Jun. 1988.
-
(1988)
IEEE Trans. Biomed. Eng.
, vol.35
, Issue.6
, pp. 494-495
-
-
Beebe, X.1
Rose, T.L.2
-
36
-
-
31544432573
-
Microfabricated cylindrical multielectrodes for neural stimulation
-
DOI 10.1109/TBME.2005.862552
-
S. Snow, S. C. Jacobsen, D. L. Wells, and K. W. Horch, "Microfabricated cylindrical multielectrodes for neural stimulation," IEEE Trans. Biomed. Eng., vol. 53, no. 2, pp. 320-326, Feb. 2006. (Pubitemid 43162420)
-
(2006)
IEEE Transactions on Biomedical Engineering
, vol.53
, Issue.2
, pp. 320-326
-
-
Snow, S.1
Jacobsen, S.C.2
Wells, D.L.3
Horch, K.W.4
-
37
-
-
84996169082
-
Electrodeposition of the platinum group metals
-
F. H. Reid, "Electrodeposition of the platinum group metals," Metallurgical Rev., vol. 8, no. 30, pp. 167-211, 1963.
-
(1963)
Metallurgical Rev.
, vol.8
, Issue.30
, pp. 167-211
-
-
Reid, F.H.1
-
38
-
-
11344276846
-
Model of frequent, recurrent, and spontaneous seizures in the intact mouse hippocampus
-
DOI 10.1002/hipo.20007
-
M. Derchansky, E. Shahar, R. A.Wennberg, M. Samoilova, S. S. Jahromi, P. A. Abdemalik, L. Zhang, and P. L. Carlen, "Model of frequent, recurrent and spontaneous seizures in the intact mouse hippocampus," Hippocampus, vol. 14, no. 8, pp. 935-947, Apr. 2004. (Pubitemid 40073655)
-
(2004)
Hippocampus
, vol.14
, Issue.8
, pp. 935-947
-
-
Derchansky, M.1
Shahar, E.2
Wennberg, R.A.3
Samoilova, M.4
Jahromi, S.S.5
Abdelmalik, P.A.6
Zhang, L.7
Carlen, P.L.8
-
39
-
-
58449109701
-
Maintaining network activity in submerged hippocampal slices: Importance in oxygen supply
-
Jan.
-
N. Hajos, T. J. Ellender, R. Zemankovics, E. O. Mann, R. Exley, S. J. Cragg, T. F. Freund, and O. Paulsen, "Maintaining network activity in submerged hippocampal slices: Importance in oxygen supply," Eur. J. Neurosci., vol. 29, no. 2, pp. 319-327, Jan. 2009.
-
(2009)
Eur. J. Neurosci.
, vol.29
, Issue.2
, pp. 319-327
-
-
Hajos, N.1
Ellender, T.J.2
Zemankovics, R.3
Mann, E.O.4
Exley, R.5
Cragg, S.J.6
Freund, T.F.7
Paulsen, O.8
|