메뉴 건너뛰기




Volumn 100, Issue 11, 2011, Pages 4934-4942

Mathematical modeling of variables involved in dissolution testing

Author keywords

Dissolution rate; Dissolution testing; In vitro models; Mathematical model; Variables

Indexed keywords

PREDNISONE;

EID: 80053241913     PISSN: 00223549     EISSN: 15206017     Source Type: Journal    
DOI: 10.1002/jps.22673     Document Type: Article
Times cited : (30)

References (28)
  • 1
    • 33747373878 scopus 로고    scopus 로고
    • A century of dissolution research: From Noyes and Whitney to the Biopharmaceutics Classification System
    • Dokoumetzidis A, Macheras P. 2006. A century of dissolution research: From Noyes and Whitney to the Biopharmaceutics Classification System. Int J Pharm 321:1-11.
    • (2006) Int J Pharm , vol.321 , pp. 1-11
    • Dokoumetzidis, A.1    Macheras, P.2
  • 2
    • 0141800053 scopus 로고    scopus 로고
    • FIP/AAPS guidelines to dissolution/in vitro release testing of novel/special dosage forms
    • article.
    • Siewert M, Dressman J, Brown CK, Shah VP. 2003. FIP/AAPS guidelines to dissolution/in vitro release testing of novel/special dosage forms. AAPS PharmSciTech 4(1):article 7.
    • (2003) AAPS PharmSciTech , vol.4 , Issue.1 , pp. 7
    • Siewert, M.1    Dressman, J.2    Brown, C.K.3    Shah, V.P.4
  • 3
    • 0006967910 scopus 로고
    • Industry perspective on dissolution apparatus calibration
    • McCormick TJ. 1995. Industry perspective on dissolution apparatus calibration. Dissolution Technol 2(4):12-15.
    • (1995) Dissolution Technol , vol.2 , Issue.4 , pp. 12-15
    • McCormick, T.J.1
  • 4
    • 33845185965 scopus 로고
    • Calibration of dissolution rate apparatuses: A user's perspective
    • Skoug JW. 1994. Calibration of dissolution rate apparatuses: A user's perspective. Dissolution Technol 1(2):3-5.
    • (1994) Dissolution Technol , vol.1 , Issue.2 , pp. 3-5
    • Skoug, J.W.1
  • 5
    • 0020085526 scopus 로고
    • System error associated with apparatus 2 of the USP dissolution test II: Effects of deviations in vessel curvature from that of a sphere
    • Cox DC, Wells CE, Furman WB, Savage TS, King AC. 1982. System error associated with apparatus 2 of the USP dissolution test II: Effects of deviations in vessel curvature from that of a sphere. J Pharm Sci 71:395-399.
    • (1982) J Pharm Sci , vol.71 , pp. 395-399
    • Cox, D.C.1    Wells, C.E.2    Furman, W.B.3    Savage, T.S.4    King, A.C.5
  • 6
    • 0021277012 scopus 로고
    • Collaborative study of the USP dissolution test for prednisone tablets with apparatus 2
    • Cox DC, Furman WB. 1984. Collaborative study of the USP dissolution test for prednisone tablets with apparatus 2. J Pharm Sci 73:670-676.
    • (1984) J Pharm Sci , vol.73 , pp. 670-676
    • Cox, D.C.1    Furman, W.B.2
  • 7
    • 0036138303 scopus 로고    scopus 로고
    • Typical variability and evaluation of sources of variability in drug dissolution testing
    • Siewert M, Weinandy L, Whiteman D, Judkins C. 2002. Typical variability and evaluation of sources of variability in drug dissolution testing. Eur J Pharm Sci 53:9-14.
    • (2002) Eur J Pharm Sci , vol.53 , pp. 9-14
    • Siewert, M.1    Weinandy, L.2    Whiteman, D.3    Judkins, C.4
  • 8
    • 0033674245 scopus 로고    scopus 로고
    • Cause of high variability in drug dissolution testing and its impact on setting tolerances
    • Qureshi SA, Shabnam J. 2001. Cause of high variability in drug dissolution testing and its impact on setting tolerances. Eur J Pharm Sci 12:271-276.
    • (2001) Eur J Pharm Sci , vol.12 , pp. 271-276
    • Qureshi, S.A.1    Shabnam, J.2
  • 9
    • 33745900777 scopus 로고    scopus 로고
    • Effects of deaeration methods on dissolution testing in aqueous media: A study using a total dissolved gas pressure meter
    • Gao Z, Moore TW, Doub WH, Westenberger BJ, Buhse LF. 2006. Effects of deaeration methods on dissolution testing in aqueous media: A study using a total dissolved gas pressure meter. J Pharm Sci 95:1606-1613.
    • (2006) J Pharm Sci , vol.95 , pp. 1606-1613
    • Gao, Z.1    Moore, T.W.2    Doub, W.H.3    Westenberger, B.J.4    Buhse, L.F.5
  • 12
    • 0036119657 scopus 로고    scopus 로고
    • Sensitivity of dissolution rate to location in the paddle dissolution apparatus
    • Healy AM, McCarthy LG, Gallagher KM, Corrigan OI. 2002. Sensitivity of dissolution rate to location in the paddle dissolution apparatus. J Pharm Pharmacol 54:441-444.
    • (2002) J Pharm Pharmacol , vol.54 , pp. 441-444
    • Healy, A.M.1    McCarthy, L.G.2    Gallagher, K.M.3    Corrigan, O.I.4
  • 13
    • 3242754188 scopus 로고    scopus 로고
    • Shear distribution and variability in the USP apparatus 2 under turbulent conditions
    • Kukura J. 2004. Shear distribution and variability in the USP apparatus 2 under turbulent conditions. Int J Pharm 279:9-17.
    • (2004) Int J Pharm , vol.279 , pp. 9-17
    • Kukura, J.1
  • 14
    • 13844276813 scopus 로고    scopus 로고
    • Hydrodynamics-induced variability in the USP apparatus II
    • Baxter JL, Kukura J, Muzzio FJ. 2005. Hydrodynamics-induced variability in the USP apparatus II. Int J Pharm 292:17-28.
    • (2005) Int J Pharm , vol.292 , pp. 17-28
    • Baxter, J.L.1    Kukura, J.2    Muzzio, F.J.3
  • 15
    • 23144456859 scopus 로고    scopus 로고
    • Computational fluid dynamics modeling of the paddle dissolution apparatus: Agitation rate, mixing patterns, and fluid velocities
    • article 31.
    • McCarthy LG, Bradley G, Sexton JC, Corrigan OI, Healy AM. 2004. Computational fluid dynamics modeling of the paddle dissolution apparatus: Agitation rate, mixing patterns, and fluid velocities. AAPS PharmSciTech 5:article 31.
    • (2004) AAPS PharmSciTech , vol.5
    • McCarthy, L.G.1    Bradley, G.2    Sexton, J.C.3    Corrigan, O.I.4    Healy, A.M.5
  • 17
    • 52449103200 scopus 로고    scopus 로고
    • Vibration effects on dissolution tests with USP apparatuses 1 and 2
    • Gao Z, Moore TW, Doub WH. 2008. Vibration effects on dissolution tests with USP apparatuses 1 and 2. J Pharm Sci 97:3335-3343.
    • (2008) J Pharm Sci , vol.97 , pp. 3335-3343
    • Gao, Z.1    Moore, T.W.2    Doub, W.H.3
  • 18
    • 0034752807 scopus 로고    scopus 로고
    • Influence of dissolution medium agitation on release profiles of sustained-release tablets
    • Costa P, Sousa Lobo JM. 2001. Influence of dissolution medium agitation on release profiles of sustained-release tablets. Drug Dev Ind Pharm 27:811-817.
    • (2001) Drug Dev Ind Pharm , vol.27 , pp. 811-817
    • Costa, P.1    Sousa Lobo, J.M.2
  • 19
    • 0037436925 scopus 로고    scopus 로고
    • The power law can describe the "entire" drug release curve from HPMC-based matrix tablets: A hypothesis
    • Rinaki E, Valsami G, Macheras P. 2003. The power law can describe the "entire" drug release curve from HPMC-based matrix tablets: A hypothesis. Int J Pharm 255:199-207.
    • (2003) Int J Pharm , vol.255 , pp. 199-207
    • Rinaki, E.1    Valsami, G.2    Macheras, P.3
  • 20
    • 0027159788 scopus 로고
    • Modelling S-shape dissolution curves
    • Kervinen L, Yliruusi J. 1993. Modelling S-shape dissolution curves. Int J Pharm 92:115-122.
    • (1993) Int J Pharm , vol.92 , pp. 115-122
    • Kervinen, L.1    Yliruusi, J.2
  • 21
    • 0035806261 scopus 로고    scopus 로고
    • An alternative method to the evaluation of similarity factor in dissolution testing
    • Costa P. 2001. An alternative method to the evaluation of similarity factor in dissolution testing. Int J Pharm 220:77-83.
    • (2001) Int J Pharm , vol.220 , pp. 77-83
    • Costa, P.1
  • 22
    • 38349146838 scopus 로고    scopus 로고
    • Physicochemical characterization and release mechanism of a novel prednisone biodegradable microsphere formulation
    • Giovagnoli S, Blasi P, Ricci M, Schoubben A, Perioli L, Rossi C. 2008. Physicochemical characterization and release mechanism of a novel prednisone biodegradable microsphere formulation. J Pharm Sci 97: 303-317.
    • (2008) J Pharm Sci , vol.97 , pp. 303-317
    • Giovagnoli, S.1    Blasi, P.2    Ricci, M.3    Schoubben, A.4    Perioli, L.5    Rossi, C.6
  • 23
    • 0344893332 scopus 로고
    • Mechanism of sustained-action medication: Theoretical analysis of rate of release of solid drugs dispersed in solid matrices
    • Higuchi T. 1963. Mechanism of sustained-action medication: Theoretical analysis of rate of release of solid drugs dispersed in solid matrices. J Pharm Sci 52:1145-1149.
    • (1963) J Pharm Sci , vol.52 , pp. 1145-1149
    • Higuchi, T.1
  • 24
    • 0026719352 scopus 로고
    • Influence of in vitro test conditions on release of aspirin from commercial tablets
    • Nikolic L, Djuric Z, Jovanovic M. 1991. Influence of in vitro test conditions on release of aspirin from commercial tablets. J Pharm Sci 81:386-391.
    • (1991) J Pharm Sci , vol.81 , pp. 386-391
    • Nikolic, L.1    Djuric, Z.2    Jovanovic, M.3
  • 26
    • 31144453624 scopus 로고    scopus 로고
    • On the use of the Weibull function for the discernment of drug release mechanisms
    • Papdopoulou V, Kosmidis K, Vlachou M, Macheras P. 2006. On the use of the Weibull function for the discernment of drug release mechanisms. Int J Pharm 309:44-50.
    • (2006) Int J Pharm , vol.309 , pp. 44-50
    • Papdopoulou, V.1    Kosmidis, K.2    Vlachou, M.3    Macheras, P.4
  • 27
    • 0015453518 scopus 로고
    • Linearization of dissolution rate curves by the Weibull distribution
    • Langenbucher F. 1972. Linearization of dissolution rate curves by the Weibull distribution. J Pharm Pharmacol 24:979-981.
    • (1972) J Pharm Pharmacol , vol.24 , pp. 979-981
    • Langenbucher, F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.