메뉴 건너뛰기




Volumn 1, Issue 3, 2011, Pages 195-216

Monitoring protein fouling on polymeric membranes using ultrasonic frequency-domain reflectometry

Author keywords

Fouling; Microfiltration; Proteins; Ultrasonic frequency domain reflectometry

Indexed keywords

BODY FLUIDS; FILTRATION; FOULING; FREQUENCY DOMAIN ANALYSIS; IN SITU PROCESSING; MEMBRANE FOULING; MEMBRANES; PORE SIZE; PROTEINS; PURIFICATION; REFLECTION; REFLECTOMETERS; SIGNAL PROCESSING; ULTRASONIC APPLICATIONS; ULTRASONIC WAVES;

EID: 80053189485     PISSN: None     EISSN: 20770375     Source Type: Journal    
DOI: 10.3390/membranes1030195     Document Type: Article
Times cited : (20)

References (36)
  • 1
    • 0032552508 scopus 로고    scopus 로고
    • Biofouling in membrane systems-A review
    • Baker, J.S.; Dudley, L.Y. Biofouling in membrane systems-A review. Desalination 1998, 118, 81-90.
    • (1998) Desalination , vol.118 , pp. 81-90
    • Baker, J.S.1    Dudley, L.Y.2
  • 3
    • 0037110671 scopus 로고    scopus 로고
    • Transmembrane pressure profiles during constant flux microfiltration of bovine serum albumin
    • Ho, C.C.; Zydney, A.L. Transmembrane pressure profiles during constant flux microfiltration of bovine serum albumin. J. Membr. Sci. 2002, 209, 363-377.
    • (2002) J. Membr. Sci , vol.209 , pp. 363-377
    • Ho, C.C.1    Zydney, A.L.2
  • 4
    • 0042734787 scopus 로고    scopus 로고
    • Fouling with protein mixtures in microfiltration: BSA-lysozyme and BSA-pepsin
    • Palacio, L.; Ho, C.C.; Pradanos, P.; Hernandez, A.; Zydney, A.L. Fouling with protein mixtures in microfiltration: BSA-lysozyme and BSA-pepsin. J. Membr. Sci. 2003, 222, 41-51.
    • (2003) J. Membr. Sci , vol.222 , pp. 41-51
    • Palacio, L.1    Ho, C.C.2    Pradanos, P.3    Hernandez, A.4    Zydney, A.L.5
  • 5
    • 0042367747 scopus 로고    scopus 로고
    • Effect of membrane morphology on system capacity during normal flow microfiltration
    • Zydney, A.L.; Ho, C.C. Effect of membrane morphology on system capacity during normal flow microfiltration. Biotechnol. Bioeng. 2003, 83, 537-543.
    • (2003) Biotechnol. Bioeng , vol.83 , pp. 537-543
    • Zydney, A.L.1    Ho, C.C.2
  • 6
    • 0027561583 scopus 로고
    • The effect of protein fouling in microfiltration and ultrafiltration on permeate flux, protein retention and selectivity: A literature review
    • Marshall, A.D.; Munro, P.A.; Tragardh, G. The effect of protein fouling in microfiltration and ultrafiltration on permeate flux, protein retention and selectivity: A literature review. Desalination 1993, 91, 65-108.
    • (1993) Desalination , vol.91 , pp. 65-108
    • Marshall, A.D.1    Munro, P.A.2    Tragardh, G.3
  • 7
    • 0037026236 scopus 로고    scopus 로고
    • Application of a pore blockage and cake filtration model to protein fouling during microfiltration
    • Palacio, L.; Ho, C.C.; Zydney, A.L. Application of a pore blockage and cake filtration model to protein fouling during microfiltration. Biotechnol. Bioeng. 2002, 79, 260-270.
    • (2002) Biotechnol. Bioeng , vol.79 , pp. 260-270
    • Palacio, L.1    Ho, C.C.2    Zydney, A.L.3
  • 8
    • 33747204331 scopus 로고    scopus 로고
    • Protein fouling of virus filtration membranes: Effects of membrane orientation and operating conditions
    • Syedain, Z.H.; Bohonak, D.M.; Zydney, A.L. Protein fouling of virus filtration membranes: Effects of membrane orientation and operating conditions. Biotechnol. Progr. 2006, 22, 1163-1169.
    • (2006) Biotechnol. Progr , vol.22 , pp. 1163-1169
    • Syedain, Z.H.1    Bohonak, D.M.2    Zydney, A.L.3
  • 9
    • 0141992738 scopus 로고    scopus 로고
    • Transmission of BSA during cross-flow microfiltration: Influence of pH and salt concentration
    • Persson, A.; Jonsson, A.S.; Zacchi, G. Transmission of BSA during cross-flow microfiltration: Influence of pH and salt concentration. J. Membr. Sci. 2003, 223, 11-21.
    • (2003) J. Membr. Sci , vol.223 , pp. 11-21
    • Persson, A.1    Jonsson, A.S.2    Zacchi, G.3
  • 10
    • 0033999752 scopus 로고    scopus 로고
    • Recovery of alpha-agarase enzyme from fermentation broths by membrane crossflow filtration
    • Toussaint, G.; Ding, L.H.; Jaffrin, M.Y. Recovery of alpha-agarase enzyme from fermentation broths by membrane crossflow filtration. Sep. Sci. Technol. 2000, 35, 795-809.
    • (2000) Sep. Sci. Technol , vol.35 , pp. 795-809
    • Toussaint, G.1    Ding, L.H.2    Jaffrin, M.Y.3
  • 11
    • 0028858511 scopus 로고
    • Mechanisms for BSA fouling during microfiltration
    • Kelly, S.T.; Zydney, A.L. Mechanisms for BSA fouling during microfiltration. J. Membr. Sci. 1995, 107, 115-127.
    • (1995) J. Membr. Sci , vol.107 , pp. 115-127
    • Kelly, S.T.1    Zydney, A.L.2
  • 12
    • 0031554626 scopus 로고    scopus 로고
    • Protein fouling during microfiltration: Comparative behavior of different model proteins
    • Kelly, S.T.; Zydney, A.L. Protein fouling during microfiltration: Comparative behavior of different model proteins, Biotechnol. Bioeng. 1997, 55, 92-100.
    • (1997) Biotechnol. Bioeng , vol.55 , pp. 92-100
    • Kelly, S.T.1    Zydney, A.L.2
  • 13
    • 7444266265 scopus 로고    scopus 로고
    • Characterization of protein fouling on membranes: Opportunities and challenges
    • Chan, R.; Chen, V. Characterization of protein fouling on membranes: Opportunities and challenges. J. Membr. Sci. 2004, 242, 169-188.
    • (2004) J. Membr. Sci , vol.242 , pp. 169-188
    • Chan, R.1    Chen, V.2
  • 15
    • 0034282020 scopus 로고    scopus 로고
    • Investigation of membrane fouling and cleaning using ultrasonic time-domain reflectometry
    • Mairal, A.P.; Greenberg, A.R.; Krantz, W.B. Investigation of membrane fouling and cleaning using ultrasonic time-domain reflectometry. Desalination 2000, 130, 45-60.
    • (2000) Desalination , vol.130 , pp. 45-60
    • Mairal, A.P.1    Greenberg, A.R.2    Krantz, W.B.3
  • 16
    • 0036722528 scopus 로고    scopus 로고
    • Ultrasonic time-domain reflectometry as a non-destructive instrumental visualization technique to monitor inorganic fouling and cleaning on reverse osmosis membranes
    • Sanderson, R.; Li, J.; Koen, L.J.; Lorenzen, L. Ultrasonic time-domain reflectometry as a non-destructive instrumental visualization technique to monitor inorganic fouling and cleaning on reverse osmosis membranes. J. Membr. Sci. 2002, 207, 105-117.
    • (2002) J. Membr. Sci , vol.207 , pp. 105-117
    • Sanderson, R.1    Li, J.2    Koen, L.J.3    Lorenzen, L.4
  • 17
    • 25144519207 scopus 로고    scopus 로고
    • Fourier wavelets from ultrasonic spectra: A new approach for detecting the onset of fouling during microfiltration of paper mill effluent
    • Sanderson, R.D.; Li, J.; Hallbauer, D.K.; Sikder, S.K. Fourier wavelets from ultrasonic spectra: A new approach for detecting the onset of fouling during microfiltration of paper mill effluent. Environ. Sci. Technol. 2005, 39, 7299-7305.
    • (2005) Environ. Sci. Technol , vol.39 , pp. 7299-7305
    • Sanderson, R.D.1    Li, J.2    Hallbauer, D.K.3    Sikder, S.K.4
  • 18
    • 0242712297 scopus 로고    scopus 로고
    • Ultrasonic sensors for the real-time measurement of reverse osmosis membrane module fouling and cleaning
    • Greenberg, A.R.; Krantz, W.B. Ultrasonic sensors for the real-time measurement of reverse osmosis membrane module fouling and cleaning. Fluid Part. Separ. J. 2003, 15, 43-49.
    • (2003) Fluid Part. Separ. J , vol.15 , pp. 43-49
    • Greenberg, A.R.1    Krantz, W.B.2
  • 19
    • 33748057170 scopus 로고    scopus 로고
    • Use of capacitive microsensors and ultrasonic time-domain reflectometry for in-situ quantification of concentration polarization and membrane fouling in pressure-driven membrane filtration
    • Zhang, Z.; Bright, V.M.; Greenberg, A.R. Use of capacitive microsensors and ultrasonic time-domain reflectometry for in-situ quantification of concentration polarization and membrane fouling in pressure-driven membrane filtration. Sens. Actuators B Chem. 2006, 117, 323-331.
    • (2006) Sens. Actuators B Chem , vol.117 , pp. 323-331
    • Zhang, Z.1    Bright, V.M.2    Greenberg, A.R.3
  • 20
    • 58049203025 scopus 로고    scopus 로고
    • Ultrasonic time domain reflectometry for investigation of particle size effect in oil emulsion separation with crossflow microfiltration
    • Silalahi, S.H.D.; Leiknes, T.; Ali, J.; Sanderson, R. Ultrasonic time domain reflectometry for investigation of particle size effect in oil emulsion separation with crossflow microfiltration. Desalination 2009, 236, 143-151.
    • (2009) Desalination , vol.236 , pp. 143-151
    • Silalahi, S.H.D.1    Leiknes, T.2    Ali, J.3    Sanderson, R.4
  • 23
  • 24
    • 33746861979 scopus 로고    scopus 로고
    • Monitoring of polymeric membrane fouling in hollow fiber module using ultrasonic nondestructive testing
    • Liu, X.; Li, X.; Chen, X.; Zhang, Y. Monitoring of polymeric membrane fouling in hollow fiber module using ultrasonic nondestructive testing. Transact. Nonferr. Met. Soc. China 2006, 16, S845-S848.
    • (2006) Transact. Nonferr. Met. Soc. China , vol.16
    • Liu, X.1    Li, X.2    Chen, X.3    Zhang, Y.4
  • 25
    • 56649107999 scopus 로고    scopus 로고
    • Non-invasive monitoring of fouling in hollow fiber membrane via UTDR
    • Xu, X.; Li, J.; Li, H.; Cai, Y.; Cao, Y.; He, B.; Zhang, Y. Non-invasive monitoring of fouling in hollow fiber membrane via UTDR. J. Membr. Sci. 2009, 326, 103-110.
    • (2009) J. Membr. Sci , vol.326 , pp. 103-110
    • Xu, X.1    Li, J.2    Li, H.3    Cai, Y.4    Cao, Y.5    He, B.6    Zhang, Y.7
  • 26
    • 33244478523 scopus 로고    scopus 로고
    • A focused ultrasonic sensor for detection of protein fouling on tubular UF membranes
    • Li, J.X.; Chai, G.Y.; Sanderson, R.D. A focused ultrasonic sensor for detection of protein fouling on tubular UF membranes. Sens. Actuators B Chem. 2006, 114, 182-191.
    • (2006) Sens. Actuators B Chem , vol.114 , pp. 182-191
    • Li, J.X.1    Chai, G.Y.2    Sanderson, R.D.3
  • 27
    • 14744293007 scopus 로고    scopus 로고
    • Development of an ultrasonic technique for in situ investigating the properties of deposited protein during crossflow ultrafiltration
    • Li, J.X.; Chai, G.Y.; Sanderson, R.D.; Hallbauer, D.K. Development of an ultrasonic technique for in situ investigating the properties of deposited protein during crossflow ultrafiltration. J. Colloid. Interface Sci. 2005, 284, 228-238.
    • (2005) J. Colloid. Interface Sci , vol.284 , pp. 228-238
    • Li, J.X.1    Chai, G.Y.2    Sanderson, R.D.3    Hallbauer, D.K.4
  • 28
    • 0343081401 scopus 로고    scopus 로고
    • Characterization of hydrophobic microporous membranes from water permeation
    • Martinez-Diez, L.; Florido-Diaz, F.J.; Vazquez-Gonzalez, M.I. Characterization of hydrophobic microporous membranes from water permeation. Sep. Sci. Technol. 2000, 35, 1377-1389.
    • (2000) Sep. Sci. Technol , vol.35 , pp. 1377-1389
    • Martinez-Diez, L.1    Florido-Diaz, F.J.2    Vazquez-Gonzalez, M.I.3
  • 30
    • 2942738771 scopus 로고    scopus 로고
    • Non-invasive measurement of membrane morphology via UFDR: Pore-Size characterization
    • Ramaswamy, S.; Greenberg, A.R.; Peterson, M.L. Non-invasive measurement of membrane morphology via UFDR: Pore-Size characterization. J. Membr. Sci. 2004, 239, 143-154.
    • (2004) J. Membr. Sci , vol.239 , pp. 143-154
    • Ramaswamy, S.1    Greenberg, A.R.2    Peterson, M.L.3
  • 31
    • 34247140304 scopus 로고    scopus 로고
    • Extracellular-polysaccharides, soluble microbial products, and natural organic matter impact on nanofiltration membranes flux decline
    • Fonseca, A.C.; Summers, R.S.; Greenberg, A.R.; Hernandez, M. Extracellular-polysaccharides, soluble microbial products, and natural organic matter impact on nanofiltration membranes flux decline. Environ. Sci. Technol. 2007, 41, 2491-2497.
    • (2007) Environ. Sci. Technol , vol.41 , pp. 2491-2497
    • Fonseca, A.C.1    Summers, R.S.2    Greenberg, A.R.3    Hernandez, M.4
  • 32
    • 0021610183 scopus 로고
    • A viscoelastic mode for initial flux decline through reverse osmosis membrane
    • Kurokawa, Y.; Kurashige, M.; Yui, N. A viscoelastic mode for initial flux decline through reverse osmosis membrane. Desalination 1984, 52, 9-14.
    • (1984) Desalination , vol.52 , pp. 9-14
    • Kurokawa, Y.1    Kurashige, M.2    Yui, N.3
  • 33
    • 0037204913 scopus 로고    scopus 로고
    • Non-invasive visualization of the fouling of microfiltration membranes by ultrasonic time-domain reflectometry
    • Li, J.X.; Chai, G.Y.; Sanderson, R.D.; Jacobs, E.P. Non-invasive visualization of the fouling of microfiltration membranes by ultrasonic time-domain reflectometry. J. Membr. Sci. 2002, 201, 17-29.
    • (2002) J. Membr. Sci , vol.201 , pp. 17-29
    • Li, J.X.1    Chai, G.Y.2    Sanderson, R.D.3    Jacobs, E.P.4
  • 34
    • 85027993441 scopus 로고    scopus 로고
    • MS thesis, Department of Civil, Environmental, and Architectural Engineering, University of Colorado at Boulder: Boulder, CO, USA
    • Evans, E. Ultrasonic reflectometry for monitoring biofilm growth on water treatment membranes. MS thesis, Department of Civil, Environmental, and Architectural Engineering, University of Colorado at Boulder: Boulder, CO, USA, 2005.
    • (2005) Ultrasonic Reflectometry For Monitoring Biofilm Growth On Water Treatment Membranes
    • Evans, E.1
  • 35
    • 0022682003 scopus 로고
    • Fouling of an ultrafiltration membrane by a dissolved whey protein concentrate and some whey proteins
    • Nilsson, J.L. Fouling of an ultrafiltration membrane by a dissolved whey protein concentrate and some whey proteins, J. Membr. Sci. 1988, 36, 147-160.
    • (1988) J. Membr. Sci , vol.36 , pp. 147-160
    • Nilsson, J.L.1
  • 36
    • 33947643718 scopus 로고    scopus 로고
    • Ultrasound, gravimetric, and SEM studies of inorganic fouling in spiral-wound membrane modules
    • Chai, G.-Y.; Greenberg and #xF02A;, A.R.; Krantz, W.B. Ultrasound, gravimetric, and SEM studies of inorganic fouling in spiral-wound membrane modules. Desalination 2007, 208, 277-293.
    • (2007) Desalination , vol.208 , pp. 277-293
    • Chai, G.-Y.1    Greenberg, A.R.2    Krantz, W.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.