Volumn 114, Issue 1, 2006, Pages 182-191

A focused ultrasonic sensor for in situ detection of protein fouling on tubular ultrafiltration membranes

Author keywords

Bovine serum albumin; Protein fouling; Tubular membranes; Ultrafiltration; Ultrasonic time domain reflectometry

Indexed keywords

PROTEIN FOULING; TUBULAR MEMBRANES; ULTRASONIC TIME-DOMAIN REFLECTOMETRY (UTDR);

EID: 33244478523     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2005.04.041     Document Type: Article
Times cited : (41)

References (34)
  • 2
    • 0028468635 scopus 로고
    • Net-type spacers: Effect of configuration on fluid flow path and ultrafiltration flux
    • A.R. Da Costa, and A.G. Fane Net-type spacers: effect of configuration on fluid flow path and ultrafiltration flux Ind. Eng. Chem. Res. 33 7 1994 1845 1852
    • (1994) Ind. Eng. Chem. Res. , vol.33 , Issue.7 , pp. 1845-1852
    • Da Costa, A.R.1    Fane, A.G.2
  • 3
    • 0029657117 scopus 로고    scopus 로고
    • Enhanced microfiltration of bovine blood using a tubular membrane with a screw-threaded insert and oscillatory flow
    • S. Najarian, and B.J. Bellhouse Enhanced microfiltration of bovine blood using a tubular membrane with a screw-threaded insert and oscillatory flow J. Membr. Sci. 112 1996 249 261
    • (1996) J. Membr. Sci. , vol.112 , pp. 249-261
    • Najarian, S.1    Bellhouse, B.J.2
  • 4
    • 0022929367 scopus 로고
    • Mass transfer, fluid flow and membrane properties in flat and corrugated plate hyperfiltration modules
    • I.G. Racz, J.G. Wassink, and R. Klassen Mass transfer, fluid flow and membrane properties in flat and corrugated plate hyperfiltration modules Desalination 60 1986 213 222
    • (1986) Desalination , vol.60 , pp. 213-222
    • Racz, I.G.1    Wassink, J.G.2    Klassen, R.3
  • 5
    • 0025536403 scopus 로고
    • The effects of pulsatile flow on ultrafiltration fluxes in a baffled tubular membrane system
    • S.M. Finnigan, and J.A. Howell The effects of pulsatile flow on ultrafiltration fluxes in a baffled tubular membrane system Desalination 79 1990 181 202
    • (1990) Desalination , vol.79 , pp. 181-202
    • Finnigan, S.M.1    Howell, J.A.2
  • 6
    • 0028989286 scopus 로고
    • Enhancement of plasma filtration using the concept of vortex wave
    • H.R. Millward, B.J. Bell, I.J. Sobey, and R.W.H. Lewis Enhancement of plasma filtration using the concept of vortex wave J. Membr. Sci. 100 1995 121 129
    • (1995) J. Membr. Sci. , vol.100 , pp. 121-129
    • Millward, H.R.1    Bell, B.J.2    Sobey, I.J.3    Lewis, R.W.H.4
  • 7
    • 0027607423 scopus 로고
    • Dean vortices with wall flux in a curved channel membrane system. 1. A new approach to membrane module design
    • M.E. Brewster, K.Y. Chung, and G. Belfort Dean vortices with wall flux in a curved channel membrane system. 1. A new approach to membrane module design J. Membr. Sci. 81 1993 127 137
    • (1993) J. Membr. Sci. , vol.81 , pp. 127-137
    • Brewster, M.E.1    Chung, K.Y.2    Belfort, G.3
  • 8
    • 0042164483 scopus 로고    scopus 로고
    • The use of gas bubbling to enhance membrane processes - A review
    • Z.F. Cui, S. Chang, and A.G. Fane The use of gas bubbling to enhance membrane processes - a review J. Membr. Sci. 221 2003 1 35
    • (2003) J. Membr. Sci. , vol.221 , pp. 1-35
    • Cui, Z.F.1    Chang, S.2    Fane, A.G.3
  • 9
    • 0032981546 scopus 로고    scopus 로고
    • Real-time measurement of inorganic fouling of RO desalination membranes using ultrasonic time-domain reflectometry
    • A.P. Mairal, A.R. Greenberg, W.B. Krantz, and L.J. Bond Real-time measurement of inorganic fouling of RO desalination membranes using ultrasonic time-domain reflectometry J. Membr. Sci. 159 1999 185 196
    • (1999) J. Membr. Sci. , vol.159 , pp. 185-196
    • Mairal, A.P.1    Greenberg, A.R.2    Krantz, W.B.3    Bond, L.J.4
  • 10
    • 0034282020 scopus 로고    scopus 로고
    • Investigation of membrane fouling and cleaning using ultrasonic time-domain reflectometry
    • A.P. Mairal, A.R. Greenberg, and W.B. Krantz Investigation of membrane fouling and cleaning using ultrasonic time-domain reflectometry Desalination 130 2000 45 60
    • (2000) Desalination , vol.130 , pp. 45-60
    • Mairal, A.P.1    Greenberg, A.R.2    Krantz, W.B.3
  • 11
    • 0036722528 scopus 로고    scopus 로고
    • Ultrasonic time-domain reflectometry as a non-destructive visualization technique to monitor fouling and cleaning on reverse osmosis membranes
    • R.D. Sanderson, J.X. Li, L.J. Koen, and L. Lorenzen Ultrasonic time-domain reflectometry as a non-destructive visualization technique to monitor fouling and cleaning on reverse osmosis membranes J. Membr. Sci. 207 2002 105 117
    • (2002) J. Membr. Sci. , vol.207 , pp. 105-117
    • Sanderson, R.D.1    Li, J.X.2    Koen, L.J.3    Lorenzen, L.4
  • 12
    • 0037036782 scopus 로고    scopus 로고
    • Cake-layer deposition, growth and compressibility during microfiltration measured and modelled using a non-invasive ultrasonic technique
    • J.X. Li, V.Y. Hallbauer-Zadorozhnaya, D.K. Hallbauer, and R.D. Sanderson Cake-layer deposition, growth and compressibility during microfiltration measured and modelled using a non-invasive ultrasonic technique Ind. Eng. Chem. Res. 41 2002 4106 4115
    • (2002) Ind. Eng. Chem. Res. , vol.41 , pp. 4106-4115
    • Li, J.X.1    Hallbauer-Zadorozhnaya, V.Y.2    Hallbauer, D.K.3    Sanderson, R.D.4
  • 13
    • 0036994928 scopus 로고    scopus 로고
    • Non-invasive in situ visualization of membrane fouling and cleaning processes in microfiltration by ultrasonic signal reflection
    • R.D. Sanderson, J.X. Li, E.P. Jacobs, Non-invasive in situ visualization of membrane fouling and cleaning processes in microfiltration by ultrasonic signal reflection, Water SA 28 (2002 SPEC. ISS.) 78-85
    • (2002) Water SA , vol.28 , Issue.SPEC. ISS. , pp. 78-85
    • Sanderson, R.D.1    Li, J.X.2    Jacobs, E.P.3
  • 14
    • 0037446033 scopus 로고    scopus 로고
    • Direct monitoring of membrane fouling cleaning during ultrafiltration using a non-invasive ultrasonic technique
    • J.X. Li, D.K. Hallbauer, and R.D. Sanderson Direct monitoring of membrane fouling cleaning during ultrafiltration using a non-invasive ultrasonic technique J. Membr. Sci. 215 2003 33 52
    • (2003) J. Membr. Sci. , vol.215 , pp. 33-52
    • Li, J.X.1    Hallbauer, D.K.2    Sanderson, R.D.3
  • 15
    • 0037056604 scopus 로고    scopus 로고
    • Measurement and modeling of organic fouling during ultrafiltration by ultrasonic signal reflections
    • J.X. Li, V.Y. Hallbauer-Zadorozhnaya, D.K. Hallbauer, and R.D. Sanderson Measurement and modeling of organic fouling during ultrafiltration by ultrasonic signal reflections Desalination 146 2002 177 185
    • (2002) Desalination , vol.146 , pp. 177-185
    • Li, J.X.1    Hallbauer-Zadorozhnaya, V.Y.2    Hallbauer, D.K.3    Sanderson, R.D.4
  • 16
    • 0037204913 scopus 로고    scopus 로고
    • Non-invasive visualization of the fouling of microfiltration membranes by ultrasonic time-domain reflectometry
    • J.X. Li, R.D. Sanderson, and E.P. Jacobs Non-invasive visualization of the fouling of microfiltration membranes by ultrasonic time-domain reflectometry J. Membr. Sci. 201 2002 17 29
    • (2002) J. Membr. Sci. , vol.201 , pp. 17-29
    • Li, J.X.1    Sanderson, R.D.2    Jacobs, E.P.3
  • 17
    • 0037056611 scopus 로고    scopus 로고
    • In situ measurement of particle deposition and its removal in microfiltration by ultrasonic time-domain reflectometry
    • J.X. Li, and R.D. Sanderson In situ measurement of particle deposition and its removal in microfiltration by ultrasonic time-domain reflectometry Desalination 146 2002 169 175
    • (2002) Desalination , vol.146 , pp. 169-175
    • Li, J.X.1    Sanderson, R.D.2
  • 18
    • 0036681161 scopus 로고    scopus 로고
    • Ultrasonic cleaning of nylon microfiltration membranes fouled by Kraft paper mill effluent
    • J.X. Li, R.D. Sanderson, and E.P. Jacobs Ultrasonic cleaning of nylon microfiltration membranes fouled by Kraft paper mill effluent J. Membr. Sci. 205 2002 247 257
    • (2002) J. Membr. Sci. , vol.205 , pp. 247-257
    • Li, J.X.1    Sanderson, R.D.2    Jacobs, E.P.3
  • 20
    • 14744293007 scopus 로고    scopus 로고
    • Development of an ultrasonic technique for in situ investigating the properties of deposited protein during crossflow ultrafiltration
    • J.X. Li, R.D. Sanderson, G.Y. Chai, D.K. Hallbauer, Development of an ultrasonic technique for in situ investigating the properties of deposited protein during crossflow ultrafiltration, J. Colloid Interface Sci. 284 (2005) 228-238.
    • (2005) J. Colloid Interface Sci. , vol.284 , pp. 228-238
    • Li, J.X.1    Sanderson, R.D.2    Chai, G.Y.3    Hallbauer, D.K.4
  • 21
    • 0242712297 scopus 로고    scopus 로고
    • UTDR-based sensors for real-time quantification of membrane module fouling and cleaning
    • A.R. Greenberg, and W.B. Krantz UTDR-based sensors for real-time quantification of membrane module fouling and cleaning Fluid/Part. Sep. J. 15 1 2003 43 49
    • (2003) Fluid/Part. Sep. J. , vol.15 , Issue.1 , pp. 43-49
    • Greenberg, A.R.1    Krantz, W.B.2
  • 25
    • 0000645478 scopus 로고
    • Correlation of quantitative analysis precision to retention time precision and chromatographic resolution for rapid, short-column analysis
    • T.J. Bahowick, and R.E. Synovec Correlation of quantitative analysis precision to retention time precision and chromatographic resolution for rapid, short-column analysis Anal. Chem. 67 1995 631 640
    • (1995) Anal. Chem. , vol.67 , pp. 631-640
    • Bahowick, T.J.1    Synovec, R.E.2
  • 26
    • 0031646519 scopus 로고    scopus 로고
    • Standardization of second-order chromatographic/spectroscopic data for optimum chemical analysis
    • B.J. Prazen, R.E. Synovec, and B.R. Kowalski Standardization of second-order chromatographic/spectroscopic data for optimum chemical analysis Anal. Chem. 70 1998 218 225
    • (1998) Anal. Chem. , vol.70 , pp. 218-225
    • Prazen, B.J.1    Synovec, R.E.2    Kowalski, B.R.3
  • 27
    • 0032716058 scopus 로고    scopus 로고
    • Differential signal detection system for improved analysis of overlapping signals in liquid chromatography
    • S. Nakamura Differential signal detection system for improved analysis of overlapping signals in liquid chromatography J. Chromoatogr. A 859 1999 221 225
    • (1999) J. Chromoatogr. A , vol.859 , pp. 221-225
    • Nakamura, S.1
  • 28
    • 0031577560 scopus 로고    scopus 로고
    • A serum factor potentiates ACh and AMPA receptor currents via differential signal transduction pathways
    • T. Nishizaki, T. Matsuoka, T. Nomura, and K. Sumikawa A serum factor potentiates ACh and AMPA receptor currents via differential signal transduction pathways Biochem. Biophys. Res. Commun. 238 1997 565 568
    • (1997) Biochem. Biophys. Res. Commun. , vol.238 , pp. 565-568
    • Nishizaki, T.1    Matsuoka, T.2    Nomura, T.3    Sumikawa, K.4
  • 29
    • 0031164467 scopus 로고    scopus 로고
    • Microprocessor controlled three-way catalyst efficiency monitoring system
    • P.N. Botsaris, and P.D. Sparis Microprocessor controlled three-way catalyst efficiency monitoring system Microprocessors Microsyst. 20 1997 585 593
    • (1997) Microprocessors Microsyst. , vol.20 , pp. 585-593
    • Botsaris, P.N.1    Sparis, P.D.2
  • 32
    • 0022816333 scopus 로고
    • Membrane-solution interactions: Influence on pure solvent transfer during ultrafiltration
    • P. Aimar, S. Baklouti, and V. Sanchez Membrane-solution interactions: influence on pure solvent transfer during ultrafiltration J. Membr. Sci. 29 1986 207 224
    • (1986) J. Membr. Sci. , vol.29 , pp. 207-224
    • Aimar, P.1    Baklouti, S.2    Sanchez, V.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.