-
1
-
-
39449127714
-
Estimating the Prevalence of Limb Loss in the United States: 2005 to 2050
-
DOI 10.1016/j.apmr.2007.11.005, PII S0003999307017480
-
Ziegler-Graham K, MacKenzie EJ, Ephraim PL, Travison TG, Brookmeyer R. Estimating the prevalence of limb loss in the United States: 2005 to 2050. Arch Phys Med Rehabil. 2008;89: 422-429. (Pubitemid 351273168)
-
(2008)
Archives of Physical Medicine and Rehabilitation
, vol.89
, Issue.3
, pp. 422-429
-
-
Ziegler-Graham, K.1
MacKenzie, E.J.2
Ephraim, P.L.3
Travison, T.G.4
Brookmeyer, R.5
-
2
-
-
0036337337
-
Limb amputation and limb deficiency: Epidemiology and recent trends in the United States
-
Dillingham TR, Pezzin LE, MacKenzie EJ. Limb amputation and limb deficiency: Epidemiology and recent trends in the United States. South Med J. 2002;95:875-883. (Pubitemid 34858025)
-
(2002)
Southern Medical Journal
, vol.95
, Issue.8
, pp. 875-883
-
-
Dillingham, T.R.1
Pezzin, L.E.2
MacKenzie, E.J.3
-
3
-
-
10044273152
-
Casualties of war - Military care for the wounded from Iraq and Afghanistan
-
DOI 10.1056/NEJMp048317
-
Gawande A. Casualties of war: Military care for the wounded from Iraq and Afghanistan. N Engl J Med. 2004; 351:2471-2475. (Pubitemid 39603153)
-
(2004)
New England Journal of Medicine
, vol.351
, Issue.24
, pp. 2471-2475
-
-
Gawande, A.1
-
4
-
-
35848949332
-
Upper limb prosthesis use and abandonment: A survey of the last 25 years
-
DOI 10.1080/03093640600994581, PII 783699452
-
Biddiss E, Chau TT. Upper limb prosthesis use and abandonment: A survey of the last 25 years. Prosthet Orthot Int. 2007;31:236-257. (Pubitemid 350056052)
-
(2007)
Prosthetics and Orthotics International
, vol.31
, Issue.3
, pp. 236-257
-
-
Biddiss, E.1
Chau, T.2
-
5
-
-
33750974455
-
Improved myoelectric prosthesis control accomplished using multiple nerve transfers
-
DOI 10.1097/01.prs.0000242487.62487.fb, PII 0000653420061200000012
-
Hijjawi JB, Kuiken TA, Lipschutz RD, Miller LA, Stubblefield KA, Dumanian GA. Improved myoelectric prosthesis control accomplished using multiple nerve transfers. Plast Reconstr Surg. 2006;118:1573-1578. (Pubitemid 44747982)
-
(2006)
Plastic and Reconstructive Surgery
, vol.118
, Issue.7
, pp. 1573-1578
-
-
Hijjawi, J.B.1
Kuiken, T.A.2
Lipschutz, R.D.3
Miller, L.A.4
Stubblefield, K.A.5
Dumanian, G.A.6
-
6
-
-
0036247854
-
Mechanical design of a shape memory alloy actuated prosthetic hand
-
De Laurentis KJ, Mavroidis C. Mechanical design of a shape memory alloy actuated prosthetic hand. Technol Health Care 2002;10:91-106. (Pubitemid 34451133)
-
(2002)
Technology and Health Care
, vol.10
, Issue.2
, pp. 91-106
-
-
De Laurentis, K.J.1
Mavroidis, C.2
-
8
-
-
0027361583
-
State of the art in upper-limb prosthetics
-
Lamb DW. State of the art in upper-limb prosthetics. J Hand Ther. 1993;6:1-8.
-
(1993)
J Hand Ther.
, vol.6
, pp. 1-8
-
-
Lamb, D.W.1
-
9
-
-
58149333214
-
Advanced neurotech-nologies for chronic neural interfaces: New horizons and clinical opportunities
-
Kipke DR, Shain W, Buzsáki G, et al. Advanced neurotech-nologies for chronic neural interfaces: New horizons and clinical opportunities. J Neurosci. 2008;28:11830-11838.
-
(2008)
J Neurosci.
, vol.28
, pp. 11830-11838
-
-
Kipke, D.R.1
Shain, W.2
Buzsáki, G.3
-
10
-
-
26444445003
-
Response of brain tissue to chronically implanted neural electrodes
-
DOI 10.1016/j.jneumeth.2005.08.015, PII S0165027005002931
-
Polikov VS, Tresco PA, Reichert WM. Response of brain tissue to chronically implanted neural electrodes. J Neurosci Methods 2005;148:1-18. (Pubitemid 41423453)
-
(2005)
Journal of Neuroscience Methods
, vol.148
, Issue.1
, pp. 1-18
-
-
Polikov, V.S.1
Tresco, P.A.2
Reichert, W.M.3
-
11
-
-
0027703631
-
Biocompatibility of silicon-based electrode arrays implanted in feline cortical tissue
-
DOI 10.1002/jbm.820271106
-
Schmidt S, Horch K, Normann R. Biocompatibility ofsilicon-based electrode arrays implanted in feline cortical tissue. J Biomed Mater Res. 1993;27:1393-1399. (Pubitemid 23312630)
-
(1993)
Journal of Biomedical Materials Research
, vol.27
, Issue.11
, pp. 1393-1399
-
-
Schmidt, S.1
Horch, K.2
Normann, R.3
-
12
-
-
0033031501
-
Cerebral astrocyte response to micromachined silicon implants
-
DOI 10.1006/exnr.1998.6983
-
Turner JN, Shain W, Szarowski DH, et al. Cerebral astrocyte response to micromachined silicon implants. Exp Neurol. 1999;156:33-49. (Pubitemid 29152981)
-
(1999)
Experimental Neurology
, vol.156
, Issue.1
, pp. 33-49
-
-
Turner, J.N.1
Shain, W.2
Szarowski, D.H.3
Andersen, M.4
Martins, S.5
Isaacson, M.6
Craighead, H.7
-
13
-
-
0026882265
-
Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
-
DOI 10.1109/10.141202
-
Edell DJ, Toi VV, McNeil VM, Clark LD. Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex. IEEE Trans Biomed Eng. 1992;39:635-643. (Pubitemid 23002705)
-
(1992)
IEEE Transactions on Biomedical Engineering
, vol.39
, Issue.6
, pp. 635-643
-
-
Edell, D.J.1
Vo Van Toi2
McNeil, V.M.3
Clark, L.D.4
-
14
-
-
0042160197
-
Brain responses to micro-machined silicon devices
-
DOI 10.1016/S0006-8993(03)03023-3
-
Szarowski DH, Andersen MD, Retterer S, et al. Brain responses to micro-machined silicon devices. Brain Res. 2003; 983:23-35. (Pubitemid 36952564)
-
(2003)
Brain Research
, vol.983
, Issue.1-2
, pp. 23-35
-
-
Szarowski, D.H.1
Andersen, M.D.2
Retterer, S.3
Spence, A.J.4
Isaacson, M.5
Craighead, H.G.6
Turner, J.N.7
Shain, W.8
-
15
-
-
34247563831
-
Residual Motor Signal in Long-Term Human Severed Peripheral Nerves and Feasibility of Neural Signal-Controlled Artificial Limb
-
DOI 10.1016/j.jhsa.2007.02.021, PII S0363502307003048
-
Jia X, Koenig MA, Zhang X, Zhang J, Chen T, Chen Z. Residual motor signal in long-term human severed peripheral nerves and feasibility of neural signal-controlled artificial limb. J Hand Surg Am. 2007;32:657-666. (Pubitemid 46680378)
-
(2007)
Journal of Hand Surgery
, vol.32
, Issue.5
, pp. 657-666
-
-
Jia, X.1
Koenig, M.A.2
Zhang, X.3
Zhang, J.4
Chen, T.5
Chen, Z.6
-
16
-
-
37549069766
-
Fiber composition of the rat sciatic nerve and its modification during regeneration through a sieve electrode
-
Castro J, Negredo P, Avendaño C. Fiber composition of the rat sciatic nerve and its modification during regeneration through a sieve electrode. Brain Res. 2008;1190:65-77.
-
(2008)
Brain Res.
, vol.1190
, pp. 65-77
-
-
Castro, J.1
Negredo, P.2
Avendaño, C.3
-
17
-
-
0031659840
-
Degeneration and regeneration in rabbit peripheral nerve with long-term nerve cuff electrode implant: A stereological study of myelinated and unmyelinated axons
-
DOI 10.1007/s004010050907
-
Larsen JO, Thomsen M, Haugland M, Sinkjaer T. Degeneration and regeneration in rabbit peripheral nerve with long-term nerve cuff electrode implant: A stereological study of myelinated and unmyelinated axons. Acta Neuropathol. 1998; 96:365-378. (Pubitemid 28451142)
-
(1998)
Acta Neuropathologica
, vol.96
, Issue.4
, pp. 365-378
-
-
Larsen, J.O.1
Thomsen, M.2
Haugland, M.3
Sinkjaer, T.4
-
18
-
-
0030066135
-
Cuff electrodes for chronic stimulation and recording of peripheral nerve activity
-
DOI 10.1016/0165-0270(95)00123-9
-
Loeb GE, Peck RA. Cuff electrodes for chronic stimulation and recording of peripheral nerve activity. J Neurosci Methods 1996;64:95-103. (Pubitemid 26069896)
-
(1996)
Journal of Neuroscience Methods
, vol.64
, Issue.1
, pp. 95-103
-
-
Loeb, G.E.1
Peck, R.A.2
-
19
-
-
33947672394
-
Time course of tissue remodelling and electrophysiology in the rat sciatic nerve after spiral cuff electrode implantation
-
DOI 10.1016/j.jneuroim.2007.01.021, PII S0165572807000422
-
Thil MA, Duy DT, Colin IM, Delbeke J. Time course of tissue remodelling and electrophysiology in the rat sciatic nerve after spiral cuff electrode implantation. J Neuroimmunol. 2007;185:103-114. (Pubitemid 46497451)
-
(2007)
Journal of Neuroimmunology
, vol.185
, Issue.1-2
, pp. 103-114
-
-
Thil, M.-A.1
Duy, D.T.2
Colin, I.M.3
Delbeke, J.4
-
20
-
-
61349183843
-
Multifunctional nanobiomaterials for neural interfaces
-
Abidian MR, Martin DC. Multifunctional nanobiomaterials for neural interfaces. Adv Funct Mater. 2009;19:573-585.
-
(2009)
Adv Funct Mater.
, vol.19
, pp. 573-585
-
-
Abidian, M.R.1
Martin, D.C.2
-
21
-
-
57149127112
-
Neural interfaces at the nanoscale
-
Pancrazio JJ. Neural interfaces at the nanoscale. Nanomedicine (Lond.) 2008;3:823-830.
-
(2008)
Nanomedicine (Lond.)
, vol.3
, pp. 823-830
-
-
Pancrazio, J.J.1
-
22
-
-
0030674829
-
Plasma-etched neural probes
-
PII S092442479701371X
-
Kewley DT, Hills MD, Borkholder DA, et al. Plasma-etched neural probes. Sens Actuators A Phys. 1997;58:27-35. (Pubitemid 127388320)
-
(1997)
Sensors and Actuators, A: Physical
, vol.58
, Issue.1
, pp. 27-35
-
-
Kewley, D.T.1
Hills, M.D.2
Borkholder, D.A.3
Opris, I.E.4
Maluf, N.I.5
Storment, C.W.6
Bower, J.M.7
Kovacs, G.T.A.8
-
23
-
-
0141479956
-
Chronic, multisite, multielectrode recordings in macaque monkeys
-
DOI 10.1073/pnas.1934665100
-
Nicolelis MA, Dimitrov D, Carmena JM, et al. Chronic, mul-tisite, multielectrode recordings in macaque monkeys. Proc Natl Acad Sci USA. 2003;100:11041-11046. (Pubitemid 37140149)
-
(2003)
Proceedings of the National Academy of Sciences of the United States of America
, vol.100
, Issue.19
, pp. 11041-11046
-
-
Nicolelis, M.A.L.1
Dimitrov, D.2
Carmena, J.M.3
Crist, R.4
Lehew, G.5
Kralik, J.D.6
Wise, S.P.7
-
24
-
-
34249846306
-
Neural probe design for reduced tissue encapsulation in CNS
-
DOI 10.1016/j.biomaterials.2007.03.024, PII S014296120700258X
-
Seymour JP, Kipke DR. Neural probe design for reduced tissue encapsulation in CNS. Biomaterials 2007;28:3594-3607. (Pubitemid 46860320)
-
(2007)
Biomaterials
, vol.28
, Issue.25
, pp. 3594-3607
-
-
Seymour, J.P.1
Kipke, D.R.2
-
25
-
-
41149164617
-
The influence of porous silicon on axonal outgrowth in vitro
-
DOI 10.1109/TBME.2007.912423
-
Johansson F, Kanje M, Linsmeier CE, Wallman L. The influence of porous silicon on axonal outgrowth in vitro. IEEE Trans Biomed Eng. 2008;55:1447-1449. (Pubitemid 351440487)
-
(2008)
IEEE Transactions on Biomedical Engineering
, vol.55
, Issue.4
, pp. 1447-1449
-
-
Johansson, F.1
Kanje, M.2
Linsmeier, C.E.3
Wallman, L.4
-
26
-
-
70350215573
-
In vivo performance of a microelectrode neural probe with integrated drug delivery
-
Rohatgi P, Langhals NB, Kipke DR, Patil PG. In vivo performance of a microelectrode neural probe with integrated drug delivery. Neurosurg Focus 2009;27:E8.
-
(2009)
Neurosurg Focus
, vol.27
-
-
Rohatgi, P.1
Langhals, N.B.2
Kipke, D.R.3
Patil, P.G.4
-
27
-
-
3242737677
-
Information capacity of the corticospinal tract recordings as a neural interface
-
Sahin M. Information capacity of the corticospinal tract recordings as a neural interface. Ann Biomed Eng. 2004;32:823-830.
-
(2004)
Ann Biomed Eng.
, vol.32
, pp. 823-830
-
-
Sahin, M.1
-
28
-
-
2442716494
-
Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex
-
DOI 10.1109/TBME.2004.826680
-
Vetter RJ, Williams JC, Hetke JF, Nunamaker EA, Kipke DR. Chronic neural recording using silicon-substrate microelec-trode arrays implanted in cerebral cortex. IEEE Trans Biomed Eng. 2004;51:896-904. (Pubitemid 38661440)
-
(2004)
IEEE Transactions on Biomedical Engineering
, vol.51
, Issue.6
, pp. 896-904
-
-
Vetter, R.J.1
Williams, J.C.2
Hetke, J.F.3
Nunamaker, E.A.4
Kipke, D.R.5
-
29
-
-
0033360081
-
Real-time control of a robot arm using simultaneously recorded neurons in the motor cortex
-
DOI 10.1038/10223
-
Chapin JK, Moxon KA, Markowitz RS, Nicolelis MA. Realtime control of a robot arm using simultaneously recorded neurons in the motor cortex. Nat Neurosci. 1999;2:664-670. (Pubitemid 30491219)
-
(1999)
Nature Neuroscience
, vol.2
, Issue.7
, pp. 664-670
-
-
Chapin, J.K.1
Moxon, K.A.2
Markowitz, R.S.3
Nicolelis, M.A.L.4
-
30
-
-
0034097189
-
Skeletal muscle reinnervation by reduced axonal numbers results in whole muscle force deficits
-
Cederna PS, Youssef MK, Asato H, Urbanchek MG, Kuzon WM Jr. Skeletal muscle reinnervation by reduced axonal numbers results in whole muscle force deficits. Plast Reconstr Surg. 2000;105:2003-2009; discussion 2010-2011. (Pubitemid 30244003)
-
(2000)
Plastic and Reconstructive Surgery
, vol.105
, Issue.6
, pp. 2003-2009
-
-
Cederna, P.S.1
Youssef, M.K.H.2
Asato, H.3
Urbanchek, M.G.4
Kuzon Jr., W.M.5
-
31
-
-
2942532182
-
Muscle-nerve-muscle neurotization for the reinnervation of denervated somatic muscle
-
DOI 10.1179/016164104225013824
-
Urbanchek MG, Ganz DE, Aydin MA, van der Meulen MA, Kuzon WM Jr. Muscle-nerve-muscle neurotization for the reinnervation of denervated somatic muscle. Neurol Res. 2004;26:388-394. (Pubitemid 38758460)
-
(2004)
Neurological Research
, vol.26
, Issue.4
, pp. 388-394
-
-
Urbanchek, M.G.1
Ganz, D.E.2
Aydin, M.A.3
Van Der Meulen, J.H.4
Kuzon Jr., W.M.5
-
32
-
-
0033079609
-
The effect of reinnervation on force production and power output in skeletal muscle
-
DOI 10.1006/jsre.1998.5498
-
Yoshimura K, Asato H, Cederna PS, Urbanchek MG, Kuzon WM. The effect of reinnervation on force production and power output in skeletal muscle. J Surg Res. 1999;81:201-208. (Pubitemid 29397812)
-
(1999)
Journal of Surgical Research
, vol.81
, Issue.2
, pp. 201-208
-
-
Yoshimura, K.1
Asato, H.2
Cederna, P.S.3
Urbanchek, M.G.4
Kuzon Jr., W.M.5
-
33
-
-
0029926554
-
Deletion of individual muscles alters rat walking-track parameters
-
Reynolds JL, Urbanchek MS, Asato H, Kuzon WM Jr. Deletion of individual muscles alters rat walking-track parameters. J Reconstr Microsurg. 1996;12:461-466. (Pubitemid 26359218)
-
(1996)
Journal of Reconstructive Microsurgery
, vol.12
, Issue.7
, pp. 461-466
-
-
Reynolds, J.L.1
Urbanchek, M.S.2
Asato, H.3
Kuzon Jr., W.M.4
-
34
-
-
0019938340
-
An index of the functional condition of rat sciatic nerve based on measurements made from walking tracks
-
DOI 10.1016/0014-4886(82)90234-5
-
de Medinaceli L, Freed WJ, Wyatt RJ. An index of the functional condition of rat sciatic nerve based on measurements made from walking tracks. Exp Neurol. 1982;77:634-643. (Pubitemid 12011176)
-
(1982)
Experimental Neurology
, vol.77
, Issue.3
, pp. 634-643
-
-
De Medinaceli, L.1
Freed, W.J.2
Wyatt, R.J.3
-
35
-
-
0034905724
-
Methodological issues in size estimation of myelinated nerve fibers in peripheral nerves
-
Geuna S, Tos P, Guglielmone R, Battiston B, Giacobini-Robecchi MG. Methodological issues in size estimation of myelinated nerve fibers in peripheral nerves. Anat Embryol (Berl.) 2001;204:1-10. (Pubitemid 32661488)
-
(2001)
Anatomy and Embryology
, vol.203
, Issue.6
, pp. 1-10
-
-
Geuna, S.1
Tos, P.2
Guglielmone, R.3
Battiston, B.4
Giacobini-Robecchi, M.G.5
-
36
-
-
0025955394
-
Changes in nerve fiber numbers distal to a nerve repair in the rat sciatic nerve model
-
Mackinnon SE, Dellon AL, O'Brien JP. Changes in nerve fiber numbers distal to a nerve repair in the rat sciatic nerve model. Muscle Nerve 1991;14:1116-1122.
-
(1991)
Muscle Nerve
, vol.14
, pp. 1116-1122
-
-
MacKinnon, S.E.1
Dellon, A.L.2
O'Brien, J.P.3
-
37
-
-
33644480416
-
-
International Organization for Standardization ANSI/AAMI/ISO 10993. Geneva, Switzerland: International Organization for Standardization
-
International Organization for Standardization. Biological Evaluation of Medical Devices: Part 11. Tests for Systemic Toxicity. ANSI/AAMI/ISO 10993. Geneva, Switzerland: International Organization for Standardization; 2006.
-
(2006)
Biological Evaluation of Medical Devices: Part 11. Tests for Systemic Toxicity
-
-
|