메뉴 건너뛰기




Volumn 140, Issue 3, 2011, Pages 568-569

Obstructive? Restrictive? Or a ventilatory impairment?

Author keywords

[No Author keywords available]

Indexed keywords

AIRWAY OBSTRUCTION; ANALYTICAL PARAMETERS; EDITORIAL; FORCED EXPIRATORY VOLUME; FORCED VITAL CAPACITY; HUMAN; LOWER LIMIT OF NORMAL; LUNG FUNCTION TEST; LUNG VENTILATION; LUNG VOLUME; PRIORITY JOURNAL; RESIDUAL VOLUME; TOTAL LUNG CAPACITY; VENTILATORY IMPAIRMENT;

EID: 80052676301     PISSN: 00123692     EISSN: 19313543     Source Type: Journal    
DOI: 10.1378/chest.11-0935     Document Type: Editorial
Times cited : (5)

References (14)
  • 1
    • 0026038935 scopus 로고
    • Lung function testing: Selection of reference values and interpretative strategies
    • American Thoracic Society
    • American Thoracic Society. Lung function testing: selection of reference values and interpretative strategies. Am Rev Respir Dis. 1991;144(5):1202-1218.
    • (1991) Am Rev Respir Dis , vol.144 , Issue.5 , pp. 1202-1218
  • 5
    • 0038752573 scopus 로고    scopus 로고
    • Lung function and mortality in the United States: Data from the First National Health and Nutrition Examination Survey follow up study
    • DOI 10.1136/thorax.58.5.388
    • Mannino DM, Buist AS, Petty TL, Enright PL, Redd SC. Lung function and mortality in the United States: data from the First National Health and Nutrition Examination Survey follow up study. Thorax. 2003;58(5):388-393. (Pubitemid 36560940)
    • (2003) Thorax , vol.58 , Issue.5 , pp. 388-393
    • Mannino, D.M.1    Buist, A.S.2    Petty, T.L.3    Enright, P.L.4    Redd, S.C.5
  • 6
    • 80052669894 scopus 로고    scopus 로고
    • Grading the severity of obstruction in mixed obstructive-restrictive lung disease
    • Gardner ZS, Ruppel GL, Kaminsky DA. Grading the severity of obstruction in mixed obstructive-restrictive lung disease. Chest. 2011;140(3):598-603.
    • (2011) Chest , vol.140 , Issue.3 , pp. 598-603
    • Gardner, Z.S.1    Ruppel, G.L.2    Kaminsky, D.A.3
  • 7
    • 40649122825 scopus 로고    scopus 로고
    • Forced vital capacity and forced expiratory volume in six seconds as predictors of reduced total lung capacity
    • Vandevoorde J, Verbanck S, Schuermans D, et al. Forced vital capacity and forced expiratory volume in six seconds as predictors of reduced total lung capacity. Eur Respir J. 2008;31(2):391-395.
    • (2008) Eur Respir J , vol.31 , Issue.2 , pp. 391-395
    • Vandevoorde, J.1    Verbanck, S.2    Schuermans, D.3
  • 8
    • 0032952725 scopus 로고    scopus 로고
    • Lung volumes in 4,774 patients with obstructive lung disease
    • DOI 10.1378/chest.115.1.68
    • Dykstra BJ, Scanlon PD, Kester MM, Beck KC, Enright PL. Lung volumes in 4,774 patients with obstructive lung disease. Chest. 1999;115(1):68-74. (Pubitemid 29047055)
    • (1999) Chest , vol.115 , Issue.1 , pp. 68-74
    • Dykstm, B.J.1    Scanion, P.D.2    Rester, M.M.3    Beck, K.C.4    Enright, P.L.5
  • 9
    • 0038467505 scopus 로고    scopus 로고
    • A spirometry-based algorithm to direct lung function testing in the pulmonary function laboratory
    • DOI 10.1378/chest.123.6.1939
    • Glady CA, Aaron SD, Lunau M, Clinch J, Dales RE. A spirometry-based algorithm to direct lung function testing in the pulmonary function laboratory. Chest. 2003;123(6):1939-1946. (Pubitemid 36706715)
    • (2003) Chest , vol.123 , Issue.6 , pp. 1939-1946
    • Glady, C.A.1    Aaron, S.D.2    Lunau, M.3    Clinch, J.4    Dales, R.E.5
  • 10
    • 0032992901 scopus 로고    scopus 로고
    • How accurate is spirometry at predicting restrictive pulmonary impairment?
    • DOI 10.1378/chest.115.3.869
    • Aaron SD, Dales RE, Cardinal P. How accurate is spirometry at predicting restrictive pulmonary impairment? Chest. 1999;115(3):869-873. (Pubitemid 29129975)
    • (1999) Chest , vol.115 , Issue.3 , pp. 869-873
    • Aaron, S.D.1    Dales, R.E.2    Cardinal, P.3
  • 11
    • 79953735491 scopus 로고    scopus 로고
    • The nonspecific pulmonary function test: Longitudinal follow-up and outcomes
    • Iyer VN, Schroeder DR, Parker KO, Hyatt RE, Scanlon PD. The nonspecific pulmonary function test: longitudinal follow-up and outcomes. Chest. 2011;139(4):878-886.
    • (2011) Chest , vol.139 , Issue.4 , pp. 878-886
    • Iyer, V.N.1    Schroeder, D.R.2    Parker, K.O.3    Hyatt, R.E.4    Scanlon, P.D.5
  • 13
    • 33847096020 scopus 로고    scopus 로고
    • 1/FVC ratio below the fifth percentile, not < 70%
    • DOI 10.1378/chest.06-1349
    • Hansen JE, Sun X-G, Wasserman K. Spirometric criteria for airway obstruction: use percentage of FEV1/FVC ratio below the fifth percentile, not < 70%. Chest. 2007;131(2):349-355. (Pubitemid 46280391)
    • (2007) Chest , vol.131 , Issue.2 , pp. 349-355
    • Hansen, J.E.1    Sun, X.-G.2    Wasserman, K.3
  • 14
    • 78651436467 scopus 로고    scopus 로고
    • Interpreting lung function data using 80% predicted and fixed thresholds misclassifies more than 20% of patients
    • Miller MR, Quanjer PH, Swanney MP, Ruppel G, Enright PL. Interpreting lung function data using 80% predicted and fixed thresholds misclassifies more than 20% of patients. Chest. 2011;139(1):52-59.
    • (2011) Chest , vol.139 , Issue.1 , pp. 52-59
    • Miller, M.R.1    Quanjer, P.H.2    Swanney, M.P.3    Ruppel, G.4    Enright, P.L.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.