메뉴 건너뛰기




Volumn 139, Issue 4, 2011, Pages 878-886

The nonspecific pulmonary function test: Longitudinal follow-up and outcomes

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AIRWAY OBSTRUCTION; AIRWAY RESISTANCE; ARTICLE; CONTROLLED STUDY; DIAGNOSTIC VALUE; FEMALE; FOLLOW UP; HUMAN; LUNG ALVEOLUS; LUNG DIFFUSION CAPACITY; LUNG DISEASE; LUNG FUNCTION TEST; LUNG VOLUME; MAJOR CLINICAL STUDY; MALE; PREDICTION; PRIORITY JOURNAL; RESTRICTIVE LUNG DISEASE; SPIROMETRY; TOTAL LUNG CAPACITY;

EID: 79953735491     PISSN: 00123692     EISSN: 19313543     Source Type: Journal    
DOI: 10.1378/chest.10-0804     Document Type: Article
Times cited : (81)

References (16)
  • 2
    • 60249085762 scopus 로고    scopus 로고
    • Conditions associated with an abnormal nonspecific pattern of pulmonary function tests
    • Hyatt RE, Cowl CT, Bjoraker JA, Scanlon PD. Conditions associated with an abnormal nonspecific pattern of pulmonary function tests. Chest. 2009;135(2):419-424.
    • (2009) Chest , vol.135 , Issue.2 , pp. 419-424
    • Hyatt, R.E.1    Cowl, C.T.2    Bjoraker, J.A.3    Scanlon, P.D.4
  • 3
    • 0032802811 scopus 로고    scopus 로고
    • Small airways obstruction syndrome
    • DOI 10.1378/chest.116.1.231
    • Stǎnescu D. Small airways obstruction syndrome. Chest. 1999;116(1):231-233. (Pubitemid 29340287)
    • (1999) Chest , vol.116 , Issue.1 , pp. 231-233
    • Stanescu, D.1
  • 5
    • 0020574263 scopus 로고
    • Single breath diffusing capacity in a representative sample of the population of Michigan, a large industrial state. Predicted values, lower limits of normal, and frequencies of abnormality by smoking history
    • Miller A, Thornton JC, Warshaw R, Anderson H, Teirstein AS, Selikoff IJ. Single breath diffusing capacity in a representative sample of the population of Michigan, a large industrial state. Predicted values, lower limits of normal, and frequencies of abnormality by smoking history. Am Rev Respir Dis. 1983;127(3):270-277.
    • (1983) Am Rev Respir Dis , vol.127 , Issue.3 , pp. 270-277
    • Miller, A.1    Thornton, J.C.2    Warshaw, R.3    Anderson, H.4    Teirstein, A.S.5    Selikoff, I.J.6
  • 6
    • 0022917588 scopus 로고
    • 1: Prediction equations from a probability sample of Michigan, a large industrial state
    • Miller A, Thornton JC, Warshaw R, Bernstein J, Selikoff IJ, Teirstein AS. Mean and instantaneous expiratory flows, FVC and FEV1: prediction equations from a probability sample of Michigan, a large industrial state. Bull Eur Physiopathol Respir. 1986;22(6):589-597. (Pubitemid 17014558)
    • (1986) Clinical Respiratory Physiology , vol.22 , Issue.6 , pp. 589-597
    • Miller, A.1    Thornton, J.C.2    Warshaw, R.3
  • 9
    • 60249085762 scopus 로고    scopus 로고
    • Conditions associated with an abnormal nonspecific pattern of pulmonary function tests
    • Hyatt RE, Cowl CT, Bjoraker JA, Scanlon PD. Conditions associated with an abnormal nonspecific pattern of pulmonary function tests. Chest. 2009;135(2):419-424.
    • (2009) Chest , vol.135 , Issue.2 , pp. 419-424
    • Hyatt, R.E.1    Cowl, C.T.2    Bjoraker, J.A.3    Scanlon, P.D.4
  • 10
    • 0013891163 scopus 로고
    • Effect of age, sex, stature, and smoking habits on human airway conductance
    • Pelzer AM, Thomson ML. Effect of age, sex, stature, and smoking habits on human airway conductance. J Appl Physiol. 1966;21(2):469-476.
    • (1966) J Appl Physiol , vol.21 , Issue.2 , pp. 469-476
    • Pelzer, A.M.1    Thomson, M.L.2
  • 11
    • 0026038935 scopus 로고
    • Lung function testing: Selection of reference values and interpretative strategies
    • American Thoracic Society
    • American Thoracic Society. Lung function testing: selection of reference values and interpretative strategies. Am Rev Respir Dis. 1991;144(5):1202-1218.
    • (1991) Am Rev Respir Dis , vol.144 , Issue.5 , pp. 1202-1218
  • 12
    • 0027564322 scopus 로고
    • Lung volumes and forced ventilatory flows. Report Work ing Party Standardization of Lung Function Tests, European Com munity for Steel and Coal
    • Official Statement of the European Respiratory Society
    • Quanjer PH, Tammeling GJ, Cotes JE, Pedersen OF, Peslin R, Yernault JC; Official Statement of the European Respiratory Society. Lung volumes and forced ventilatory flows. Report Work ing Party Standardization of Lung Function Tests, European Com munity for Steel and Coal. Eur Respir J Suppl. 1993;16:5-40.
    • (1993) Eur Respir J Suppl , vol.16 , pp. 5-40
    • Quanjer, P.H.1    Tammeling, G.J.2    Cotes, J.E.3    Pedersen, O.F.4    Peslin, R.5    Yernault, J.C.6
  • 13
    • 0034880912 scopus 로고    scopus 로고
    • An 8-year follow-up of carbon monoxide diffusing capacity in a general population sample of northern italy
    • DOI 10.1378/chest.120.1.74
    • Viegi G, Sherrill DL, Carrozzi L, et al. An 8-year follow-up of carbon monoxide diffusing capacity in a general population sample of northern Italy. Chest. 2001;120(1):74-80. (Pubitemid 32744860)
    • (2001) Chest , vol.120 , Issue.1 , pp. 74-80
    • Viegi, G.1    Sherrill, D.L.2    Carrozzi, L.3    Di, P.F.4    Baldacci, S.5    Pistelli, F.6    Enright, P.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.