메뉴 건너뛰기




Volumn 43, Issue 10, 2011, Pages 777-784

Comparison of neutrophil volume distribution width to C-reactive protein and procalcitonin as a proposed new marker of acute infection

Author keywords

Acute infection; CRP; Haematology indices; Neutrophil volume distribution width; Procalcitonin

Indexed keywords

C REACTIVE PROTEIN; PROCALCITONIN;

EID: 80052493230     PISSN: 00365548     EISSN: 16511980     Source Type: Journal    
DOI: 10.3109/00365548.2011.585179     Document Type: Article
Times cited : (33)

References (20)
  • 1
    • 0027920980 scopus 로고
    • Pathogenetic mechanisms of septic shock
    • Parrillo JE. Pathogenetic mechanisms of septic shock. N Engl J Med 1993;328:1471-7.
    • (1993) N Engl J Med , vol.328 , pp. 1471-7
    • Parrillo, J.E.1
  • 2
    • 0029401567 scopus 로고
    • The Italian SEPSIS study: Preliminary results on the incidence and evolution of SIRS, sepsis, severe sepsis and septic shock
    • Salvo I, de Cian W, Musicco M, Langer M, Piadena R, Wolfler A, et al. The Italian SEPSIS study: preliminary results on the incidence and evolution of SIRS, sepsis, severe sepsis and septic shock. Intensive Care Med 1995;21(Suppl 2):S244-9.
    • (1995) Intensive Care Med , vol.21 , Issue.SUPPL. 2
    • Salvo, I.1    De Cian, W.2    Musicco, M.3    Langer, M.4    Piadena, R.5    Wolfler, A.6
  • 4
    • 0038129417 scopus 로고    scopus 로고
    • Comparison of procalcitonin and C-reactive protein as markers of sepsis
    • DOI 10.1097/01.CCM.0000063440.19188.ED
    • Luzzani A, Polati E, Dorizzi R, Rungatscher A, Pavan R, Merlini A. Comparison of procalcitonin and C-reactive protein as markers of sepsis. Crit Care Med 2003;31:1737-41. (Pubitemid 36714230)
    • (2003) Critical Care Medicine , vol.31 , Issue.6 , pp. 1737-1741
    • Luzzani, A.1    Polati, E.2    Dorizzi, R.3    Rungatscher, A.4    Pavan, R.5    Merlini, A.6
  • 5
    • 34147204322 scopus 로고    scopus 로고
    • Neutrophil VCS parameters are superior indicators for acute infection
    • DOI 10.1532/LH96.06048
    • Bagdasaryan R, Zhou Z, Tierno B, Rosenman D, Xu D. Neu-trophil VCS parameters are superior indicators for acute infection. Lab Hematol 2007;13:12-6. (Pubitemid 46578457)
    • (2007) Laboratory Hematology , vol.13 , Issue.1 , pp. 12-16
    • Bagdasaryan, R.1    Zhou, Z.2    Tierno, B.3    Rosenman, D.4    Xu, D.5
  • 6
    • 24144432049 scopus 로고    scopus 로고
    • Quantitative determination of neutrophil VCS parameters by the Coulter automated hematology analyzer: New and reliable indicators for acute bacterial infection
    • DOI 10.1309/LLF7-5W0F-WQQ8-TCC5
    • Chaves F, Tierno B, Xu D. Quantitative determination of neutrophil VCS parameters by the Coulter automated hema-tology analyzer: new and reliable indicators for acute bacterial infection. Am J Clin Pathol 2005;124:440-4. (Pubitemid 41232931)
    • (2005) American Journal of Clinical Pathology , vol.124 , Issue.3 , pp. 440-444
    • Chaves, F.1    Tierno, B.2    Xu, D.3
  • 7
    • 33644969264 scopus 로고    scopus 로고
    • Neutrophil volume distribution width: A new automated hematologic parameter for acute infection
    • Chaves F, Tierno B, Xu D. Neutrophil volume distribution width: a new automated hematologic parameter for acute infection. Arch Pathol Lab Med 2006;130:378-80.
    • (2006) Arch Pathol Lab Med , vol.130 , pp. 378-80
    • Chaves, F.1    Tierno, B.2    Xu, D.3
  • 8
    • 0006371989 scopus 로고    scopus 로고
    • Definitions for sepsis and organ failure and guidelines for the use of innovative therapies in sepsis
    • The ACCP/SCCM Consensus Conference Committee. American College of Chest Physicians/Society of Critical Care Medicine
    • Bone RC, Balk RA, Cerra FB, Dellinger RP, Fein AM, Knaus WA, et al. Definitions for sepsis and organ failure and guidelines for the use of innovative therapies in sepsis. The ACCP/SCCM Consensus Conference Committee. American College of Chest Physicians/Society of Critical Care Medicine. Chest 2009;136:e28.
    • (2009) Chest , vol.136
    • Bone, R.C.1    Balk, R.A.2    Cerra, F.B.3    Dellinger, R.P.4    Fein, A.M.5    Knaus, W.A.6
  • 9
    • 66449093196 scopus 로고    scopus 로고
    • Procalcitonin as a prognostic and diagnostic tool for septic complications after major trauma
    • Castelli GP, Pognani C, Cita M, Paladini R. Procalcitonin as a prognostic and diagnostic tool for septic complications after major trauma. Crit Care Med 2009;37:1845-9.
    • (2009) Crit Care Med , vol.37 , pp. 1845-9
    • Castelli, G.P.1    Pognani, C.2    Cita, M.3    Paladini, R.4
  • 10
    • 33745622134 scopus 로고    scopus 로고
    • Procalcitonin as a diagnostic test for sepsis in critically ill adults and after surgery or trauma: A systematic review and meta-analysis
    • DOI 10.1097/01.CCM.0000226413.54364.36, PII 0000324620060700000020
    • Uzzan B, Cohen R,Nicolas P, Cucherat M, Perret GY. Procalcitonin as a diagnostic test for sepsis in critically ill adults and after surgery or trauma: a systematic review and meta-analysis. Crit Care Med 2006; 34:1996-2003. (Pubitemid 43982479)
    • (2006) Critical Care Medicine , vol.34 , Issue.7 , pp. 1996-2003
    • Uzzan, B.1    Cohen, R.2    Nicolas, P.3    Cucherat, M.4    Perret, G.-Y.5
  • 11
    • 0027466275 scopus 로고
    • High serum procalcitonin concentrations in patients with sepsis and infection
    • DOI 10.1016/0140-6736(93)90277-N
    • Assicot M, Gendrel D, Carsin H, Raymond J, Guilbaud J, Bohuon C. High serum procalcitonin concentrations in patients with sepsis and infection. Lancet 1993;341:515-8. (Pubitemid 23066085)
    • (1993) Lancet , vol.341 , Issue.8844 , pp. 515-518
    • Assicot, M.1    Gendrel, D.2    Carsin, H.3    Raymond, J.4    Guilbaud, J.5    Bohuon, C.6
  • 13
    • 33749504187 scopus 로고    scopus 로고
    • Neutrophil distribution width study flawed [3]
    • Tetrault G. Neutrophil distribution width study flawed. Arch Pathol Lab Med 2006;130:1428-9; author reply 9-30. (Pubitemid 44520705)
    • (2006) Archives of Pathology and Laboratory Medicine , vol.130 , Issue.10 , pp. 1428-1429
    • Tetrault, G.1
  • 17
    • 77953549271 scopus 로고    scopus 로고
    • Utility of hemato-logic and volume, conductivity, and scatter parameters from umbilical cord blood in predicting chorioamnionitis
    • Lee JC, Ahern TP, Chaves FP, Quillen K. Utility of hemato-logic and volume, conductivity, and scatter parameters from umbilical cord blood in predicting chorioamnionitis. Int J Lab Hematol 2010;32:351-9.Mardi D, Fwity B, Lobmann R, Ambrosch A. Mean cell volume of neutrophils and monocytes compared with C-reactive protein, interleukin-6 and white blood cell count for prediction of sepsis and nonsystemic bacterial infections. Int J Lab Hematol 2010;32:410-8.
    • (2010) Int J Lab Hematol , vol.32 , pp. 351-9
    • Lee, J.C.1    Ahern, T.P.2    Chaves, F.P.3    Quillen, K.4
  • 18
    • 77957970897 scopus 로고    scopus 로고
    • Mean cell volume of neutrophils and monocytes compared with C-reactive protein, interleukin-6 and white blood cell count for prediction of sepsis and nonsystemic bacterial infections
    • Mardi D, Fwity B, Lobmann R, Ambrosch A. Mean cell volume of neutrophils and monocytes compared with C-reactive protein, interleukin-6 and white blood cell count for prediction of sepsis and nonsystemic bacterial infections. Int J Lab Hematol 2010;32:410-8.
    • (2010) Int J Lab Hematol , vol.32 , pp. 410-8
    • Mardi, D.1    Fwity, B.2    Lobmann, R.3    Ambrosch, A.4
  • 19
    • 79959573477 scopus 로고    scopus 로고
    • Screening of sepsis using leukocyte cell population data from the Coulter automatic blood cell analyzer DxH800
    • doi: 10.1111/j.1751-553X.2011.01298.x
    • Park DH, Park K, Park J, Park HH, Chae H, Lim J, et al. Screening of sepsis using leukocyte cell population data from the Coulter automatic blood cell analyzer DxH800. Int J Lab Hematol doi: 10.1111/j.1751-553X.2011.01298.x.
    • Int J Lab Hematol
    • Park, D.H.1    Park, K.2    Park, J.3    Park, H.H.4    Chae, H.5    Lim, J.6
  • 20
    • 1542465774 scopus 로고    scopus 로고
    • Évaluation de l'analyseur d'hématologie Beckman Coulter® LH 750™: Performances analytiques, regles de décision
    • Amouroux I, Balay M, Marfaing-Koka A. [Evaluation of the blood analyzer Beckman Coulter LH 750: analytic performance, decision rules]. Ann Biol Clin (Paris) 2003;61: 576-84. (Pubitemid 37144143)
    • (2003) Annales de Biologie Clinique , vol.61 , Issue.5 , pp. 576-584
    • Amouroux, I.1    Balay, M.2    Marfaing-Koka, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.