Volumn 124, Issue 3, 2005, Pages 440-444

Quantitative determination of neutrophil VCS parameters by the Coulter automated hematology analyzer: New and reliable indicators for acute bacterial infection

Author keywords

Automated hematology analyzer; Bacterial infection; Neutrophil; VCS parameters

Indexed keywords

ARTICLE; AUTOANALYZER; BACTERIAL INFECTION; BLOOD ANALYSIS; CELL VOLUME; CONDUCTANCE; HUMAN; LEUKOCYTE COUNT; LEUKOCYTOSIS; LIGHT SCATTERING; MAJOR CLINICAL STUDY; NEUTROPHIL; NEUTROPHILIA; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; SENSITIVITY AND SPECIFICITY; SEPSIS;

EID: 24144432049     PISSN: 00029173     EISSN: None     Source Type: Journal    
DOI: 10.1309/LLF75W0FWQQ8TCC5     Document Type: Article
Times cited : (101)

References (15)
  • 1
    • 0024376371 scopus 로고
    • Mechanics of stimulated neutrophils: Cell stiffening induces retention in capillaries
    • Worthen GS, Schwab B III, Elson EL, et al. Mechanics of stimulated neutrophils: Cell stiffening induces retention in capillaries. Science. 1989;245:183-186.
    • (1989) Science , vol.245 , pp. 183-186
    • Worthen, G.S.1    Schwab III, B.2    Elson, E.L.3
  • 2
    • 0031784698 scopus 로고    scopus 로고
    • Passive deformability of mature, immature, and active neutrophils in healthy and septicemic neonates
    • Linderkamp O, Ruef P, Brenner B, et al. Passive deformability of mature, immature, and active neutrophils in healthy and septicemic neonates. Pediatr Res. 1998;44:946-950.
    • (1998) Pediatr Res , vol.44 , pp. 946-950
    • Linderkamp, O.1    Ruef, P.2    Brenner, B.3
  • 3
    • 0031048898 scopus 로고    scopus 로고
    • Laboratory tests in evaluation of acute febrile illness in pediatric emergency room patients
    • Procop GW, Hartman JS, Sedor F. Laboratory tests in evaluation of acute febrile illness in pediatric emergency room patients. Am J Clin Pathol. 1997;107:114-121.
    • (1997) Am J Clin Pathol , vol.107 , pp. 114-121
    • Procop, G.W.1    Hartman, J.S.2    Sedor, F.3
  • 4
    • 0022512313 scopus 로고
    • The clinical utility of the leukocyte differential in emergency medicine
    • Wenz B, Gennis P, Gaehler S, et al. The clinical utility of the leukocyte differential in emergency medicine. Am J Clin Pathol. 1986;86:298-303.
    • (1986) Am J Clin Pathol , vol.86 , pp. 298-303
    • Wenz, B.1    Gennis, P.2    Gaehler, S.3
  • 5
    • 0016190436 scopus 로고
    • The clinical usefulness of segmented vs stab neutrophil criteria for differential leukocyte counts
    • Mathy KA, Koepke JA. The clinical usefulness of segmented vs stab neutrophil criteria for differential leukocyte counts. Am J Clin Pathol. 1974;61:947-958.
    • (1974) Am J Clin Pathol , vol.61 , pp. 947-958
    • Mathy, K.A.1    Koepke, J.A.2
  • 6
    • 0035148856 scopus 로고    scopus 로고
    • Manual differential cell counts help predict bacterial infection: A multivariate analysis
    • Wile MJ, et al. Manual differential cell counts help predict bacterial infection: a multivariate analysis. Am J Clin Pathol. 2001;115:644-649.
    • (2001) Am J Clin Pathol , vol.115 , pp. 644-649
    • Wile, M.J.1
  • 7
    • 0024982206 scopus 로고
    • An automated hematology instrument for comprehensive WBC, RBC, and platelet analysis
    • Richardson-Jones A. An automated hematology instrument for comprehensive WBC, RBC, and platelet analysis. Am Clin Lab. 1990;9:18-22.
    • (1990) Am Clin Lab , vol.9 , pp. 18-22
    • Richardson-Jones, A.1
  • 8
    • 0025271234 scopus 로고
    • Automated differentials in the hematology laboratory
    • Krause JR. Automated differentials in the hematology laboratory. Am J Clin Pathol. 1990;93(4 suppl 1):S11-S16.
    • (1990) Am J Clin Pathol , vol.934 , Issue.SUPPL. 1
    • Krause, J.R.1
  • 9
    • 0036408411 scopus 로고    scopus 로고
    • Utility of haematological parameters and C-reactive protein in the detection of neonatal sepsis
    • Manucha V, Rusia U, Sikka M, et al. Utility of haematological parameters and C-reactive protein in the detection of neonatal sepsis. J Paediatr Child Health. 2002;38:459-464.
    • (2002) J Paediatr Child Health , vol.38 , pp. 459-464
    • Manucha, V.1    Rusia, U.2    Sikka, M.3
  • 10
    • 0026936704 scopus 로고
    • Advances of the past decade in automated hematology
    • Gulati GL, Hyun BH, Ashton JK. Advances of the past decade in automated hematology. Am J Clin Pathol. 1992;98(4 suppl 1):S11-S16.
    • (1992) Am J Clin Pathol , vol.984 , Issue.SUPPL. 1
    • Gulati, G.L.1    Hyun, B.H.2    Ashton, J.K.3
  • 11
    • 0027960752 scopus 로고
    • Band neutrophil counts are unnecessary for the diagnosis of infection in patients with normal total leukocyte counts
    • Ardron MJ, Westengard JC, Dutcher TF. Band neutrophil counts are unnecessary for the diagnosis of infection in patients with normal total leukocyte counts. Am J Clin Pathol. 1994;102:646-649.
    • (1994) Am J Clin Pathol , vol.102 , pp. 646-649
    • Ardron, M.J.1    Westengard, J.C.2    Dutcher, T.F.3
  • 12
    • 0036128551 scopus 로고    scopus 로고
    • Peripheral blood film review: The demise of the eyecount leukocyte differential
    • Pierre RV. Peripheral blood film review: the demise of the eyecount leukocyte differential. Clin Lab Med. 2002;22:279-297.
    • (2002) Clin Lab Med , vol.22 , pp. 279-297
    • Pierre, R.V.1
  • 13
    • 0030945439 scopus 로고    scopus 로고
    • The diagnostic value of the neutrophil left shift in predicting inflammatory and infectious disease
    • Seebach JD, Morant R, Ruegg R, et al. The diagnostic value of the neutrophil left shift in predicting inflammatory and infectious disease. Am J Clin Pathol. 1997;107:582-591.
    • (1997) Am J Clin Pathol , vol.107 , pp. 582-591
    • Seebach, J.D.1    Morant, R.2    Ruegg, R.3
  • 14
    • 0031602946 scopus 로고    scopus 로고
    • Left shift and inflammation: A never-ending story
    • Pierre RV. Left shift and inflammation: a never-ending story [letter]. Am J Cim Pathol. 1998;109:114-115.
    • (1998) Am J Cim Pathol , vol.109 , pp. 114-115
    • Pierre, R.V.1
  • 15
    • 0025971963 scopus 로고
    • Laboratory and clinical evaluation of white blood cell differential counts: Comparison of the Coulter VCS, Technicon H-1, and 800-cell manual method
    • Swaim WR. Laboratory and clinical evaluation of white blood cell differential counts: comparison of the Coulter VCS, Technicon H-1, and 800-cell manual method. Am J Clin Pathol. 1991;95:381-388.
    • (1991) Am J Clin Pathol , vol.95 , pp. 381-388
    • Swaim, W.R.1