메뉴 건너뛰기




Volumn 52, Issue 8, 2011, Pages 5121-5129

Diurnal variations in axial length, choroidal thickness, intraocular pressure, and ocular biometrics

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ANTERIOR EYE CHAMBER DEPTH; ARTICLE; BIOMETRY; CHOROID; CIRCADIAN RHYTHM; CORNEA THICKNESS; EMMETROPIA; EYE AXIS LENGTH; EYE REFRACTION; FEMALE; HUMAN; INTRAOCULAR PRESSURE; LENS; MALE; MYOPIA; NORMAL HUMAN; PRIORITY JOURNAL; RETINA; TONOMETER; VITREOUS BODY; ADOLESCENT; HISTOLOGY; OCULOPLETHYSMOGRAPHY; PATHOPHYSIOLOGY; PHYSIOLOGY; QUESTIONNAIRE; VISUAL ACUITY;

EID: 80052329499     PISSN: 01460404     EISSN: 15525783     Source Type: Journal    
DOI: 10.1167/iovs.11-7364     Document Type: Article
Times cited : (403)

References (49)
  • 1
    • 0016735286 scopus 로고
    • Diurnal variation of intraocular pressure in primary open-angle glaucoma
    • Kitazawa Y, Horie T. Diurnal variation of intraocular pressure in primary open-angle glaucoma. Am J Ophthalmol. 1975;79(4):557-566.
    • (1975) Am J Ophthalmol. , vol.79 , Issue.4 , pp. 557-566
    • Kitazawa, Y.1    Horie, T.2
  • 2
    • 0031736985 scopus 로고    scopus 로고
    • Nocturnal elevation of intraocular pressure in young adults
    • Liu JHK, Kripke DF, Hoffman RE, et al. Nocturnal elevation of intraocular pressure in young adults. Invest Ophthalmol Vis Sci. 1998;39(13):2707-2712.
    • (1998) Invest Ophthalmol Vis Sci. , vol.39 , Issue.13 , pp. 2707-2712
    • Liu, J.H.K.1    Kripke, D.F.2    Hoffman, R.E.3
  • 3
    • 33744754736 scopus 로고    scopus 로고
    • The relation of axial length and intraocular pressure fluctuations in human eyes
    • Wilson LB, Quinn GE, Ying G, et al. The relation of axial length and intraocular pressure fluctuations in human eyes. Invest Ophthalmol Vis Sci. 2006;47(5):1778-1784.
    • (2006) Invest Ophthalmol Vis Sci. , vol.47 , Issue.5 , pp. 1778-1784
    • Wilson, L.B.1    Quinn, G.E.2    Ying, G.3
  • 4
    • 48249104277 scopus 로고    scopus 로고
    • Diurnal variation of axial length, intraocular pressure, and anterior eye biometrics
    • Read SA, Collins MJ, Iskander DR. Diurnal variation of axial length, intraocular pressure, and anterior eye biometrics. Invest Ophthalmol Vis Sci. 2008;49(7):2911-2918.
    • (2008) Invest Ophthalmol Vis Sci. , vol.49 , Issue.7 , pp. 2911-2918
    • Read, S.A.1    Collins, M.J.2    Iskander, D.R.3
  • 5
    • 0020424643 scopus 로고
    • Diurnal variations of corneal topography and thickness
    • Kiely PM, Carney LG, Smith G. Diurnal variations of corneal topography and thickness. Am J Optom Physiol Opt. 1982;59(12):976-982.
    • (1982) Am J Optom Physiol Opt. , vol.59 , Issue.12 , pp. 976-982
    • Kiely, P.M.1    Carney, L.G.2    Smith, G.3
  • 6
    • 0030477331 scopus 로고    scopus 로고
    • Diurnal variations in human corneal thickness
    • Harper CL, Boulton ME, Bennett D, et al. Diurnal variations in human corneal thickness. Br J Ophthalmol. 1996;80(12):1068-1072.
    • (1996) Br J Ophthalmol. , vol.80 , Issue.12 , pp. 1068-1072
    • Harper, C.L.1    Boulton, M.E.2    Bennett, D.3
  • 7
    • 66149104139 scopus 로고    scopus 로고
    • Diurnal variation of corneal shape and thickness
    • Read SA, Collins MJ. Diurnal variation of corneal shape and thickness. Optom Vis Sci. 2009;86(3):170-180.
    • (2009) Optom Vis Sci. , vol.86 , Issue.3 , pp. 170-180
    • Read, S.A.1    Collins, M.J.2
  • 8
    • 23044455109 scopus 로고    scopus 로고
    • The diurnal variation of corneal topography and aberrations
    • Read SA, Collins MJ, Carney LG. The diurnal variation of corneal topography and aberrations. Cornea. 2005;24(6):678-687.
    • (2005) Cornea. , vol.24 , Issue.6 , pp. 678-687
    • Read, S.A.1    Collins, M.J.2    Carney, L.G.3
  • 9
    • 0021930090 scopus 로고
    • Diurnal variation in the dimensions of the anterior chamber
    • Mapstone R, Clark CV. Diurnal variation in the dimensions of the anterior chamber. Arch Ophthalmol. 1985;103(10):1485-1486.
    • (1985) Arch Ophthalmol. , vol.103 , Issue.10 , pp. 1485-1486
    • Mapstone, R.1    Clark, C.V.2
  • 11
    • 0033498326 scopus 로고    scopus 로고
    • Axial length decrease accompanying successful glaucoma filtration surgery
    • Cashwell LF, Martin CA. Axial length decrease accompanying successful glaucoma filtration surgery. Ophthalmology. 1999;106(12): 2307-2311.
    • (1999) Ophthalmology. , vol.106 , Issue.12 , pp. 2307-2311
    • Cashwell, L.F.1    Martin, C.A.2
  • 12
    • 0037243485 scopus 로고    scopus 로고
    • Axial length changes accompanying successful nonpenetrating glaucoma filtration surgery
    • Üretmen Ö, Andaç H, Andaç K, Deli B. Axial length changes accompanying successful nonpenetrating glaucoma filtration surgery. Ophthalmologica. 2003;217(3):199-203.
    • (2003) Ophthalmologica. , vol.217 , Issue.3 , pp. 199-203
    • Üretmen, Ö.1    Andaç, H.2    Andaç, K.3    Deli, B.4
  • 13
    • 11144281800 scopus 로고    scopus 로고
    • Changes in axial length following trabeculectomy and glaucoma drainage device surgery
    • Francis BA, Wang M, Lei H, et al. Changes in axial length following trabeculectomy and glaucoma drainage device surgery. Br J Ophthalmol. 2005;89(1):17-20.
    • (2005) Br J Ophthalmol. , vol.89 , Issue.1 , pp. 17-20
    • Francis, B.A.1    Wang, M.2    Lei, H.3
  • 14
    • 44049084335 scopus 로고    scopus 로고
    • Effects of change in intraocular pressure on axial eye length and lens position
    • Leydolt C, Findl O, Drexler W. Effects of change in intraocular pressure on axial eye length and lens position. Eye. 2008;22:657-661.
    • (2008) Eye. , vol.22 , pp. 657-661
    • Leydolt, C.1    Findl, O.2    Drexler, W.3
  • 15
    • 0141764856 scopus 로고    scopus 로고
    • Nocturnal elevation of intraocular pressure is detectable in the sitting position
    • Liu JHK, Bouligny RP, Kripke DF, Weinreb RN. Nocturnal elevation of intraocular pressure is detectable in the sitting position. Invest Ophthalmol Vis Sci. 2003;44(10):4439-4442.
    • (2003) Invest Ophthalmol Vis Sci. , vol.44 , Issue.10 , pp. 4439-4442
    • Liu, J.H.K.1    Bouligny, R.P.2    Kripke, D.F.3    Weinreb, R.N.4
  • 16
    • 0031887303 scopus 로고    scopus 로고
    • Ocular axial length and choroidal thickness in newly hatched chicks and one-year-old chickens fluctuate in a diurnal pattern that is influenced by visual experience and intraocular pressure changes
    • Papastergiou GI, Schmid GF, Riva CE, Mendel MJ, Stone RA, Laties AM. Ocular axial length and choroidal thickness in newly hatched chicks and one-year-old chickens fluctuate in a diurnal pattern that is influenced by visual experience and intraocular pressure changes. Exp Eye Res. 1998;66(2):195-205.
    • (1998) Exp Eye Res. , vol.66 , Issue.2 , pp. 195-205
    • Papastergiou, G.I.1    Schmid, G.F.2    Riva, C.E.3    Mendel, M.J.4    Stone, R.A.5    Laties, A.M.6
  • 17
    • 0031936981 scopus 로고    scopus 로고
    • Visual influences on diurnal rhythms in ocular length and choroidal thickness in chick eyes
    • Nickla DL, Wildsoet C, Wallman J. Visual influences on diurnal rhythms in ocular length and choroidal thickness in chick eyes. Exp Eye Res. 1998;66(2):163-181.
    • (1998) Exp Eye Res. , vol.66 , Issue.2 , pp. 163-181
    • Nickla, D.L.1    Wildsoet, C.2    Wallman, J.3
  • 18
    • 33644857816 scopus 로고    scopus 로고
    • The phase relationships between the diurnal rhythms in axial length and choroidal thickness and the association with ocular growth rate in chicks
    • Nickla DL. The phase relationships between the diurnal rhythms in axial length and choroidal thickness and the association with ocular growth rate in chicks. J Comp Physiol A. 2006;192(4):399-407.
    • (2006) J Comp Physiol A. , vol.192 , Issue.4 , pp. 399-407
    • Nickla, D.L.1
  • 19
    • 0036325038 scopus 로고    scopus 로고
    • Diurnal rhythms in intraocular pressure, axial length, and choroidal thickness in a primate model of eye growth, the common marmoset
    • Nickla DL, Wildsoet CF, Troilo D. Diurnal rhythms in intraocular pressure, axial length, and choroidal thickness in a primate model of eye growth, the common marmoset. Invest Ophthalmol Vis Sci. 2002;43(8):2519-2528.
    • (2002) Invest Ophthalmol Vis Sci. , vol.43 , Issue.8 , pp. 2519-2528
    • Nickla, D.L.1    Wildsoet, C.F.2    Troilo, D.3
  • 20
    • 58249086521 scopus 로고    scopus 로고
    • In vivo human choroidal thickness measurements: Evidence for diurnal fluctuations
    • Brown JS, Flitcroft DI, Ying G-S, et al. In vivo human choroidal thickness measurements: evidence for diurnal fluctuations. Invest Ophthalmol Vis Sci. 2009;50(1):5-12.
    • (2009) Invest Ophthalmol Vis Sci. , vol.50 , Issue.1 , pp. 5-12
    • Brown, J.S.1    Flitcroft, D.I.2    Ying, G.-S.3
  • 21
    • 0035091537 scopus 로고    scopus 로고
    • Endogenous rhythms in axial length and choroidal thickness in chicks: Implications for ocular growth regulation
    • Nickla DL, Wildsoet CF, Troilo D. Endogenous rhythms in axial length and choroidal thickness in chicks: implications for ocular growth regulation. Invest Ophthalmol Vis Sci. 2001;42(3):584-588.
    • (2001) Invest Ophthalmol Vis Sci. , vol.42 , Issue.3 , pp. 584-588
    • Nickla, D.L.1    Wildsoet, C.F.2    Troilo, D.3
  • 22
    • 0014072097 scopus 로고
    • Alcohol, vasopressin, and intraocular pressure
    • Houle RE, Grant WM. Alcohol, vasopressin, and intraocular pressure. Invest Ophthalmol Vis Sci. 1967;6(2):145-154.
    • (1967) Invest Ophthalmol Vis Sci. , vol.6 , Issue.2 , pp. 145-154
    • Houle, R.E.1    Grant, W.M.2
  • 23
    • 0036014065 scopus 로고    scopus 로고
    • Effect of coffee consumption on intraocular pressure
    • Avisar R, Avisar E, Weinberger D. Effect of coffee consumption on intraocular pressure. Ann Pharmacother. 2002;36(6):992-995.
    • (2002) Ann Pharmacother. , vol.36 , Issue.6 , pp. 992-995
    • Avisar, R.1    Avisar, E.2    Weinberger, D.3
  • 24
    • 0024389366 scopus 로고
    • The Pittsburgh Sleep Quality Index: A new instrument for psychiatric practice and research
    • Buysse DJ, Reynolds CF. The Pittsburgh Sleep Quality Index: a new instrument for psychiatric practice and research. Psychiatry Res. 1989;28(2):193-213.
    • (1989) Psychiatry Res. , vol.28 , Issue.2 , pp. 193-213
    • Buysse, D.J.1    Reynolds, C.F.2
  • 25
    • 0023783604 scopus 로고
    • Corneal epithelial permeability after instillation of ophthalmic solutions containing local anaesthetics and preservatives
    • Ramselaar JAM, Boot JP, Van Haeringen NJ, Van Best JA, Oosterhuis JA. Corneal epithelial permeability after instillation of ophthalmic solutions containing local anaesthetics and preservatives. Curr Eye Res. 1988;7(9):947-950.
    • (1988) Curr Eye Res. , vol.7 , Issue.9 , pp. 947-950
    • Ramselaar, J.A.M.1    Boot, J.P.2    van Haeringen, N.J.3    van Best, J.A.4    Oosterhuis, J.A.5
  • 26
    • 66749108908 scopus 로고    scopus 로고
    • Accuracy of a new partial coherence interferometry analyser for biometric measurements
    • Holzer MP, Mamusa M, Auffarth GU. Accuracy of a new partial coherence interferometry analyser for biometric measurements. Br J Ophthalmol. 2009;93(6):807-810.
    • (2009) Br J Ophthalmol. , vol.93 , Issue.6 , pp. 807-810
    • Holzer, M.P.1    Mamusa, M.2    Auffarth, G.U.3
  • 28
    • 0000276665 scopus 로고    scopus 로고
    • Measurement by laser Doppler interferometry of intraocular distances in humans and chicks with a precision of better than ± 20 μm
    • Schmid GF, Petrig BL, Riva CE, et al. Measurement by laser Doppler interferometry of intraocular distances in humans and chicks with a precision of better than ± 20 μm. Appl Opt. 1996;35(19):3358-3361.
    • (1996) Appl Opt. , vol.35 , Issue.19 , pp. 3358-3361
    • Schmid, G.F.1    Petrig, B.L.2    Riva, C.E.3
  • 30
    • 77954960121 scopus 로고    scopus 로고
    • Water drinking influences eye length and IOP in young normal subjects
    • Read SA, Collins MJ. Water drinking influences eye length and IOP in young normal subjects. Exp Eye Res. 2010;91(2):180-185.
    • (2010) Exp Eye Res. , vol.91 , Issue.2 , pp. 180-185
    • Read, S.A.1    Collins, M.J.2
  • 31
    • 79960357943 scopus 로고    scopus 로고
    • Validation of optical low coherence reflectometry retinal and choroidal biometry
    • Published online April 21
    • Read SA, Collins MJ, Alonso-Caneiro D. Validation of optical low coherence reflectometry retinal and choroidal biometry. Optom Vis Sci. Published online April 21, 2011.
    • (2011) Optom Vis Sci.
    • Read, S.A.1    Collins, M.J.2    Alonso-Caneiro, D.3
  • 32
    • 13844317411 scopus 로고    scopus 로고
    • Determining in vivo biomechanical properties of the cornea with an ocular response analyzer
    • Luce DA. Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J Cataract Refract Surg. 2005;31(1):156-162.
    • (2005) J Cataract Refract Surg. , vol.31 , Issue.1 , pp. 156-162
    • Luce, D.A.1
  • 33
    • 33748924156 scopus 로고    scopus 로고
    • Evaluation of the influence of corneal biomechanical properties on intraocular pressure measurements using the ocular response analyzer
    • Medeiros FA, Weinreb RN. Evaluation of the influence of corneal biomechanical properties on intraocular pressure measurements using the ocular response analyzer. J Glaucoma. 2006;15(5):364-370.
    • (2006) J Glaucoma. , vol.15 , Issue.5 , pp. 364-370
    • Medeiros, F.A.1    Weinreb, R.N.2
  • 34
    • 34548695879 scopus 로고    scopus 로고
    • Comparison of IOP measurements between ORA and GAT in normal Chinese
    • Lam A, Chen D, Chiu R, Chui WS. Comparison of IOP measurements between ORA and GAT in normal Chinese. Optom Vis Sci. 2007;84(9):909-914.
    • (2007) Optom Vis Sci. , vol.84 , Issue.9 , pp. 909-914
    • Lam, A.1    Chen, D.2    Chiu, R.3    Chui, W.S.4
  • 35
    • 0028926373 scopus 로고
    • Calculating correlation coefficients with repeated observations: Part 1. Correlation within subjects
    • Bland JM, Altman DG. Calculating correlation coefficients with repeated observations: Part 1. Correlation within subjects. BMJ. 1995;310(6977):446.
    • (1995) BMJ. , vol.310 , Issue.6977 , pp. 446
    • Bland, J.M.1    Altman, D.G.2
  • 36
    • 0036291364 scopus 로고    scopus 로고
    • Twenty-four-hour pattern of intraocular pressure in young adults with moderate to severe myopia
    • Liu JHK, Kripke DF, Twa MD, et al. Twenty-four-hour pattern of intraocular pressure in young adults with moderate to severe myopia. Invest Ophthalmol Vis Sci. 2002;43(7):2351-2355.
    • (2002) Invest Ophthalmol Vis Sci. , vol.43 , Issue.7 , pp. 2351-2355
    • Liu, J.H.K.1    Kripke, D.F.2    Twa, M.D.3
  • 39
    • 64449085730 scopus 로고    scopus 로고
    • A pilot study of enhanced depth imaging optical coherence tomography of the choroid in normal eyes
    • Margolis R, Spaide RF. A pilot study of enhanced depth imaging optical coherence tomography of the choroid in normal eyes. Am J Ophthalmology. 2009;147(5):811-815.
    • (2009) Am J Ophthalmology. , vol.147 , Issue.5 , pp. 811-815
    • Margolis, R.1    Spaide, R.F.2
  • 40
    • 77956063976 scopus 로고    scopus 로고
    • Choroidal thickness in normal eyes measured using Cirrus HD optical coherence tomography
    • Manjunath V, Taha M, Fujimoto JG, Duker JS. Choroidal thickness in normal eyes measured using Cirrus HD optical coherence tomography. Am J Ophthalmology. 2010;150(3):325-329.
    • (2010) Am J Ophthalmology. , vol.150 , Issue.3 , pp. 325-329
    • Manjunath, V.1    Taha, M.2    Fujimoto, J.G.3    Duker, J.S.4
  • 42
    • 0001526901 scopus 로고
    • The significance of the diurnal tension variations in normal and glaucomatous eyes
    • Drance SM. The significance of the diurnal tension variations in normal and glaucomatous eyes. Arch Ophthalmol. 1960;64(4): 494-501.
    • (1960) Arch Ophthalmol. , vol.64 , Issue.4 , pp. 494-501
    • Drance, S.M.1
  • 43
    • 0026349823 scopus 로고
    • Diurnal variations in intraocular pressure
    • Wilensky JT. Diurnal variations in intraocular pressure. Trans Am Ophthalmol Soc. 1991;89:757-790.
    • (1991) Trans Am Ophthalmol Soc. , vol.89 , pp. 757-790
    • Wilensky, J.T.1
  • 45
    • 0030734884 scopus 로고    scopus 로고
    • The diurnal variation of intraocular pressure in nonglaucomatous subjects: Relevance in a clinical context
    • Pointer JS. The diurnal variation of intraocular pressure in nonglaucomatous subjects: relevance in a clinical context. Ophthalmic Physiol Opt. 1997;17(6):456-465.
    • (1997) Ophthalmic Physiol Opt. , vol.17 , Issue.6 , pp. 456-465
    • Pointer, J.S.1
  • 46
    • 0018304372 scopus 로고
    • Oxygen levels beneath the closed eyelid
    • Efron N, Carney LG. Oxygen levels beneath the closed eyelid. Invest Ophthalmol Vis Sci. 1979;18(1):93-95.
    • (1979) Invest Ophthalmol Vis Sci. , vol.18 , Issue.1 , pp. 93-95
    • Efron, N.1    Carney, L.G.2
  • 47
    • 0031737183 scopus 로고    scopus 로고
    • Twenty-four-hour change in axial length in the rabbit eye
    • Liu JHK, Farid H. Twenty-four-hour change in axial length in the rabbit eye. Invest Ophthalmol Vis Sci. 1998;39(13):2796-2799.
    • (1998) Invest Ophthalmol Vis Sci. , vol.39 , Issue.13 , pp. 2796-2799
    • Liu, J.H.K.1    Farid, H.2
  • 48
    • 0034067330 scopus 로고    scopus 로고
    • Changes in anterior chamber angle width and depth after intraocular lens implantation in eyes with glaucoma
    • Hayashi K, Hayashi H, Nakao F, Hayashi F. Changes in anterior chamber angle width and depth after intraocular lens implantation in eyes with glaucoma. Ophthalmology. 2000;107(4):698-703.
    • (2000) Ophthalmology. , vol.107 , Issue.4 , pp. 698-703
    • Hayashi, K.1    Hayashi, H.2    Nakao, F.3    Hayashi, F.4
  • 49
    • 0037388598 scopus 로고    scopus 로고
    • Possible mechanisms of primary angle-closure and malignant glaucoma
    • Quigley HA, Friedman DS, Congdon NG. Possible mechanisms of primary angle-closure and malignant glaucoma. J Glaucoma. 2003; 12(2):167-180.
    • (2003) J Glaucoma , vol.12 , Issue.2 , pp. 167-180
    • Quigley, H.A.1    Friedman, D.S.2    Congdon, N.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.