메뉴 건너뛰기




Volumn 30, Issue 9, 2011, Pages 1704-1712

Bias field inconsistency correction of motion-scattered multislice mri for improved 3d image reconstruction

Author keywords

3D reconstruction; bias field inconsistency; Bias field inhomogeneity; fetal brain; multislice MRI

Indexed keywords

3D RECONSTRUCTION; BIAS FIELD; BIAS FIELD INHOMOGENEITY; FETAL BRAIN; MULTI SLICES;

EID: 80052288048     PISSN: 02780062     EISSN: None     Source Type: Journal    
DOI: 10.1109/TMI.2011.2143724     Document Type: Article
Times cited : (31)

References (29)
  • 3
    • 33644920687 scopus 로고    scopus 로고
    • Fetal central nervous system MR imaging
    • O. Glenn, "Fetal central nervous system MR imaging," Neuroimaging Clinics of North America, vol. 16, pp. 1-17, 2006.
    • (2006) Neuroimaging Clinics of North America , vol.16 , pp. 1-17
    • Glenn, O.1
  • 4
    • 4544233901 scopus 로고    scopus 로고
    • Fetal MRI: Techniques and protocols
    • DOI 10.1007/s00247-004-1246-0
    • D. Prayer, P. Brugger, and L. Prayer, "Fetal MRI: Techniques and protocols," Pediatric Radiol., vol. 34, pp. 685-693, 2004. (Pubitemid 39232474)
    • (2004) Pediatric Radiology , vol.34 , Issue.9 , pp. 685-693
    • Prayer, D.1    Brugger, P.C.2    Prayer, L.3
  • 6
    • 33747807329 scopus 로고    scopus 로고
    • Registration-based approach for reconstruction of high-resolution in utero MR brain images
    • DOI 10.1016/j.acra.2006.05.003, PII S1076633206002753
    • F. Rousseau, O. A. Glenn, B. Iordanova, C. E. Rodriguez-Carranza, D. Vigneron, J. A. Barkovich, and C. Studholme, "Registration-based approach for reconstruction of high-resolution in utero MR brain images," Acad. Radiol., vol. 13, no. 9, pp. 1072-1081, 2006. (Pubitemid 44279445)
    • (2006) Academic Radiology , vol.13 , Issue.9 , pp. 1072-1081
    • Rousseau, F.1    Glenn, O.A.2    Iordanova, B.3    Rodriguez-Carranza, C.4    Vigneron, D.B.5    Barkovich, J.A.6    Studholme, C.7
  • 8
    • 73849152809 scopus 로고    scopus 로고
    • Intersection based motion correction of multislice MRI for 3-D in utero fetal brain image formation
    • Jan
    • K. Kim, P. Habas, F. Rousseau, O. Glenn, A. Barkovich, and C. Studholme, "Intersection based motion correction of multislice MRI for 3-D in utero fetal brain image formation," IEEE Trans. Med. Imag., vol. 29, no. 1, pp. 146-158, Jan. 2010.
    • (2010) IEEE Trans. Med. Imag. , vol.29 , Issue.1 , pp. 146-158
    • Kim, K.1    Habas, P.2    Rousseau, F.3    Glenn, O.4    Barkovich, A.5    Studholme, C.6
  • 9
    • 34547288464 scopus 로고    scopus 로고
    • MRI of moving subjects using multislice Snapshot images with Volume Reconstruction (SVR): Application to fetal, neonatal, and adult brain studies
    • DOI 10.1109/TMI.2007.895456
    • S. Jiang, H. Xue, A. Glover, M. Rutherford, D. Rueckert, and J. Hajnal, "MRI of moving subjects using multislice snapshot images with volume reconstruction (SVR): Application to fetal, neonatal, and adult brain studies," IEEE Trans. Med. Imag., vol. 26, no. 7, pp. 967-980, Jul. 2007. (Pubitemid 47147244)
    • (2007) IEEE Transactions on Medical Imaging , vol.26 , Issue.7 , pp. 967-980
    • Jiang, S.1    Xue, H.2    Glover, A.3    Rutherford, M.4    Rueckert, D.5    Hajnal, J.V.6
  • 11
    • 77957579868 scopus 로고    scopus 로고
    • Robust super-resolution volume reconstruction from slice acquisitions: Application to fetal brain MRI
    • Oct
    • A. Gholipour-Baboli, J. Estroff, and S.Warfield, "Robust super-resolution volume reconstruction from slice acquisitions: Application to fetal brain MRI," IEEE Trans. Med. Imag., vol. 29, no. 10, pp. 1739-1758, Oct. 2010.
    • (2010) IEEE Trans. Med. Imag. , vol.29 , Issue.10 , pp. 1739-1758
    • Gholipour-Baboli, A.1    Estroff, J.2    Warfield, S.3
  • 12
    • 0035088714 scopus 로고    scopus 로고
    • 1 distribution, SNR, and SAR for a surface coil adjacent to an anatomically-accurate human body model
    • DOI 10.1002/mrm.1092
    • C. M. Collins and M. B. Smith, "Calculations of distribution, SNR, and SAR for a surface coil adjacent to an anatomically-accurate human body model," Magn. Reson. Med., vol. 45, pp. 692-699, 2001. (Pubitemid 32260092)
    • (2001) Magnetic Resonance in Medicine , vol.45 , Issue.4 , pp. 692-699
    • Collins, C.M.1    Smith, M.B.2
  • 13
    • 0032129166 scopus 로고    scopus 로고
    • Standing-wave and RF penetration artifacts caused by elliptic geometry: An electrodynamic analysis of MRI
    • PII S0278006298085784
    • J. G. Sled and G. B. Pike, "Standing-wave and RF penetration artifacts caused by elliptic geometry: An electrodynamic analysis of MRI," IEEE Trans. Med. Imag., vol. 17, no. 4, pp. 653-662, Aug. 1998. (Pubitemid 128747720)
    • (1998) IEEE Transactions on Medical Imaging , vol.17 , Issue.4 , pp. 653-662
    • Sled, J.G.1    Bruce Pike, G.2
  • 14
    • 0041743260 scopus 로고    scopus 로고
    • Tips and tricks of fetal MR imaging
    • DOI 10.1016/S0033-8389(03)00043-5
    • D. Levine, A. S. Smith, and C. McKenzie, "Tips and tricks of fetal MR imaging," Radiologic Clinics of North America, vol. 41, no. 4, pp. 729-745, 2003. (Pubitemid 36920075)
    • (2003) Radiologic Clinics of North America , vol.41 , Issue.4 , pp. 729-745
    • Levine, D.1    Smith, A.S.2    McKenzie, C.3
  • 16
    • 33847774807 scopus 로고    scopus 로고
    • A review of methods for correction of intensity inhomogeneity in MRI
    • DOI 10.1109/TMI.2006.891486
    • U. Vovk, F. Pernus, and B. Likar, "A review of methods for correction of intensity inhomogeneity in MRI," IEEE Trans. Med. Imag., vol. 26, no. 3, pp. 405-421, Mar. 2007. (Pubitemid 46392348)
    • (2007) IEEE Transactions on Medical Imaging , vol.26 , Issue.3 , pp. 405-421
    • Vovk, U.1    Pernus, F.2    Likar, B.3
  • 17
    • 31744442025 scopus 로고    scopus 로고
    • Intensity non-uniformity correction in MRI: Existing methods and their validation
    • DOI 10.1016/j.media.2005.09.004, PII S1361841505000976
    • B. Belaroussi, J. Milles, S. Carme, Y. M. Zhu, and H. Benoit-Cattin, "Intensity non-uniformity correction in MRI: Existing methods and their validation," Med. Image Anal., vol. 10, pp. 234-246, 2006. (Pubitemid 43174976)
    • (2006) Medical Image Analysis , vol.10 , Issue.2 , pp. 234-246
    • Belaroussi, B.1    Milles, J.2    Carme, S.3    Zhu, Y.M.4    Benoit-Cattin, H.5
  • 18
    • 0037308183 scopus 로고    scopus 로고
    • A dual image approach for bias field correction in magnetic resonance imaging
    • DOI 10.1016/S0730-725X(02)00637-9
    • S.-H. Lai and M. Fang, "A dual image approach for bias field correction in magnetic resonance imaging," Magn. Reson. Imag., vol. 21, pp. 121-125, 2003. (Pubitemid 36418730)
    • (2003) Magnetic Resonance Imaging , vol.21 , Issue.2 , pp. 121-125
    • Lai, S.-H.1    Fang, M.2
  • 20
    • 80052295806 scopus 로고    scopus 로고
    • Joint MRI bias removal using entropy minimization across images
    • L. K. Saul, Y. Weiss, and L. Bottou, Eds. Cambridge, MA: MIT Press
    • E. G. Learned-Miller and P. Ahammad, "Joint MRI bias removal using entropy minimization across images," in Advances in Neural Information Processing Systems 17, L. K. Saul, Y. Weiss, and L. Bottou, Eds. Cambridge, MA: MIT Press, 2005, pp. 761-768.
    • (2005) Advances in Neural Information Processing Systems , vol.17 , pp. 761-768
    • Learned-Miller, E.G.1    Ahammad, P.2
  • 21
    • 20444501009 scopus 로고    scopus 로고
    • Unified segmentation
    • DOI 10.1016/j.neuroimage.2005.02.018, PII S1053811905001102
    • J. Ashburner and K. Friston, "Unified segmentation," Neuroimage, vol. 26, pp. 839-851, 2005. (Pubitemid 40825026)
    • (2005) NeuroImage , vol.26 , Issue.3 , pp. 839-851
    • Ashburner, J.1    Friston, K.J.2
  • 25
    • 77956061106 scopus 로고    scopus 로고
    • A spatiotemporal atlas of MR intensity, tissue probability and shape of the fetal brain with application to segmentation
    • P. Habas, K. Kim, J. Corbett-Detig, F. Rousseau, O. Glenn, A. Barkovich, and C. Studholme, "A spatiotemporal atlas of MR intensity, tissue probability and shape of the fetal brain with application to segmentation," Neuroimage, vol. 53, no. 2, pp. 460-470, 2010.
    • (2010) Neuroimage , vol.53 , Issue.2 , pp. 460-470
    • Habas, P.1    Kim, K.2    Corbett-Detig, J.3    Rousseau, F.4    Glenn, O.5    Barkovich, A.6    Studholme, C.7
  • 26
    • 0016068330 scopus 로고
    • The Fourier reconstruction of a head section
    • L. A. Shepp and B. F. Logan, "The Fourier reconstruction of a head section," IEEE Trans. Nucl. Sci., vol. 21, no. 3, pp. 21-43, 1974.
    • (1974) IEEE Trans. Nucl. Sci. , vol.21 , Issue.3 , pp. 21-43
    • Shepp, L.A.1    Logan, B.F.2
  • 27
    • 77956276314 scopus 로고    scopus 로고
    • Atlas-based segmentation of developing tissues in the human brain with quantitative validation in young fetuses
    • Sep
    • P. Habas, K. Kim, F. Rousseau, O. Glenn, A. Barkovich, and C. Studholme, "Atlas-based segmentation of developing tissues in the human brain with quantitative validation in young fetuses," Hum. Brain Mapp., vol. 31, no. 9, pp. 1348-1358, Sep. 2010.
    • (2010) Hum. Brain Mapp. , vol.31 , Issue.9 , pp. 1348-1358
    • Habas, P.1    Kim, K.2    Rousseau, F.3    Glenn, O.4    Barkovich, A.5    Studholme, C.6
  • 29
    • 0031987382 scopus 로고    scopus 로고
    • A nonparametric method for automatic correction of intensity nonuniformity in mri data
    • PII S0278006298031516
    • J. Sled, A. Zijdenbos, and A. Evans, "A nonparametric method for automatic correction of intensity nonuniformity in MRI data," IEEE Trans. Med. Imag., vol. 17, no. 1, pp. 87-97, Feb. 1998. (Pubitemid 128742012)
    • (1998) IEEE Transactions on Medical Imaging , vol.17 , Issue.1 , pp. 87-97
    • Sied, J.G.1    Zijdenbos, A.P.2    Evans, A.C.3