메뉴 건너뛰기




Volumn 41, Issue 4, 2003, Pages 729-745

Tips and tricks of fetal MR imaging

Author keywords

[No Author keywords available]

Indexed keywords

ARTIFACT; ARTIFACT REDUCTION; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; DIAGNOSTIC VALUE; FEMALE; FETUS; FETUS DEVELOPMENT; FETUS MALFORMATION; FETUS MONITORING; FUNCTIONAL ANATOMY; GESTATIONAL AGE; HUMAN; IMAGE ANALYSIS; NON INVASIVE MEASUREMENT; NUCLEAR MAGNETIC RESONANCE IMAGING; OBSERVER VARIATION; PRIORITY JOURNAL; RADIOLOGIST; REVIEW; SIGNAL NOISE RATIO; TECHNIQUE;

EID: 0041743260     PISSN: 00338389     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0033-8389(03)00043-5     Document Type: Review
Times cited : (19)

References (23)
  • 1
    • 0025151834 scopus 로고
    • The use of magnetic resonance imaging for the diagnosis of fetal intracranial anomalies
    • Dinh DH, Wright RM, Hanigan WC. The use of magnetic resonance imaging for the diagnosis of fetal intracranial anomalies. Childs Nerv Syst 1990;6: 212-5.
    • (1990) Childs Nerv Syst , vol.6 , pp. 212-215
    • Dinh, D.H.1    Wright, R.M.2    Hanigan, W.C.3
  • 2
    • 0030848484 scopus 로고    scopus 로고
    • Perinatal ultrasonography and magnetic resonance imaging findings in congenital hydrocephalus associated with fetal intraventricular hemorrhage
    • Fusch C, Ozdoba C, Kuhn P, Durig P, Remonda L, Muller C, et al. Perinatal ultrasonography and magnetic resonance imaging findings in congenital hydrocephalus associated with fetal intraventricular hemorrhage. Am J Obstet Gynecol 1997;177:512-8.
    • (1997) Am J Obstet Gynecol , vol.177 , pp. 512-518
    • Fusch, C.1    Ozdoba, C.2    Kuhn, P.3    Durig, P.4    Remonda, L.5    Muller, C.6
  • 7
    • 0007710692 scopus 로고    scopus 로고
    • Fast MRI of fetal CNS anomalies with prenatal MRI: Results of 149 cases
    • Levine D, Mehta T, Trap I, Barnes P. Fast MRI of fetal CNS anomalies with prenatal MRI: results of 149 cases [abstract]. Radiology 2000;217:101.
    • (2000) Radiology , vol.217 , pp. 101
    • Levine, D.1    Mehta, T.2    Trap, I.3    Barnes, P.4
  • 9
    • 0031938351 scopus 로고    scopus 로고
    • Fetal fast MR imaging: Reproducibility, technical quality, and conspicuity of anatomy
    • Levine D, Barnes PD, Sher S, Semelka RC, Li W, McArdle CR, et al. Fetal fast MR imaging: reproducibility, technical quality, and conspicuity of anatomy. Radiology 1998;206:549-54.
    • (1998) Radiology , vol.206 , pp. 549-554
    • Levine, D.1    Barnes, P.D.2    Sher, S.3    Semelka, R.C.4    Li, W.5    McArdle, C.R.6
  • 10
    • 0032967698 scopus 로고    scopus 로고
    • State of the art: Obstetric MR imaging
    • Levine D, Barnes PD, Edelman RR. State of the art: obstetric MR imaging. Radiology 1999;211:609-17.
    • (1999) Radiology , vol.211 , pp. 609-617
    • Levine, D.1    Barnes, P.D.2    Edelman, R.R.3
  • 12
    • 0031919128 scopus 로고    scopus 로고
    • Prenatal MRI evaluation of giant neck masses in preparation for the fetal exit procedure
    • Hubbard AM, Crombleholme TM, Adzick NS. Prenatal MRI evaluation of giant neck masses in preparation for the fetal exit procedure. Am J Perinatol 1998;15:253-7.
    • (1998) Am J Perinatol , vol.15 , pp. 253-257
    • Hubbard, A.M.1    Crombleholme, T.M.2    Adzick, N.S.3
  • 13
    • 0033385933 scopus 로고    scopus 로고
    • A new tool for prenatal diagnosis: Ultrafast fetal MRI
    • Hubbard AM, Harty MP, States LJ. A new tool for prenatal diagnosis: ultrafast fetal MRI. Semin Perinatol 1999;23:437-47.
    • (1999) Semin Perinatol , vol.23 , pp. 437-447
    • Hubbard, A.M.1    Harty, M.P.2    States, L.J.3
  • 15
    • 0035115401 scopus 로고    scopus 로고
    • The effects of 1.5T magnetic resonance imaging on early murine in-vitro embryo development
    • Chew S, Ahmadi A, Goh PS, Foong LC. The effects of 1.5T magnetic resonance imaging on early murine in-vitro embryo development. J Magn Reson Imaging 2001;13:417-20.
    • (2001) J Magn Reson Imaging , vol.13 , pp. 417-420
    • Chew, S.1    Ahmadi, A.2    Goh, P.S.3    Foong, L.C.4
  • 17
    • 0028439839 scopus 로고
    • Pregnancy and the safety of magnetic resonance imaging
    • Kanal E. Pregnancy and the safety of magnetic resonance imaging. Magn Reson Imaging Clin N Am 1994; 2:309-17.
    • (1994) Magn Reson Imaging Clin N Am , vol.2 , pp. 309-317
    • Kanal, E.1
  • 18
    • 0035007150 scopus 로고    scopus 로고
    • Potential heating effect in the gravid uterus during MR HASTE imaging
    • Levine D, Zuo C, Faro CB, Chen Q. Potential heating effect in the gravid uterus during MR HASTE imaging. J Magn Reson Imaging 2001;13:856-61.
    • (2001) J Magn Reson Imaging , vol.13 , pp. 856-861
    • Levine, D.1    Zuo, C.2    Faro, C.B.3    Chen, Q.4
  • 19
    • 0031801071 scopus 로고    scopus 로고
    • Failure to detect intrauterine growth restriction following in utero exposure to MRI
    • Myers C, Duncan KR, Gowland PA, Johnson IR, Baker PN. Failure to detect intrauterine growth restriction following in utero exposure to MRI. Br J Radiol 1998;71:549-51.
    • (1998) Br J Radiol , vol.71 , pp. 549-551
    • Myers, C.1    Duncan, K.R.2    Gowland, P.A.3    Johnson, I.R.4    Baker, P.N.5
  • 20
    • 0019945449 scopus 로고
    • NMR imaging produces no observable mutations or cytotoxicity in mammalian cells
    • Schwartz JL, Crooks LE. NMR imaging produces no observable mutations or cytotoxicity in mammalian cells. AJR Am J Roentgenol 1982;139:583-5.
    • (1982) AJR Am J Roentgenol , vol.139 , pp. 583-585
    • Schwartz, J.L.1    Crooks, L.E.2
  • 21
    • 0018875060 scopus 로고
    • Tests for DNA and chromosomal damage induced by nuclear magnetic resonance imaging
    • Wolff S, Crooks LE, Brown P, Howard R, Painter RB. Tests for DNA and chromosomal damage induced by nuclear magnetic resonance imaging. Radiology 1980; 136:707-10.
    • (1980) Radiology , vol.136 , pp. 707-710
    • Wolff, S.1    Crooks, L.E.2    Brown, P.3    Howard, R.4    Painter, R.B.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.