메뉴 건너뛰기




Volumn 21, Issue 2, 2003, Pages 121-125

A dual image approach for bias field correction in magnetic resonance imaging

Author keywords

Image fusion; Intensity inhomogeneity correction; Magnetic resonance imaging; Medical image restoration; Spline surface fitting

Indexed keywords

ALGORITHM; ARTICLE; ARTIFACT; IMAGE INTENSIFIER; IMAGE RECONSTRUCTION; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; SURFACE PROPERTY;

EID: 0037308183     PISSN: 0730725X     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0730-725X(02)00637-9     Document Type: Article
Times cited : (25)

References (11)
  • 1
    • 0030126711 scopus 로고    scopus 로고
    • Segmentation of multiple sclerosis lesions in intensity corrected multispectral MRI
    • Johnston B, Atkins MS, Mackiewich B, Anderson M. Segmentation of multiple sclerosis lesions in intensity corrected multispectral MRI. IEEE Trans Medical Imaging 1996;15(2):154-9.
    • (1996) IEEE Trans Medical Imaging , vol.15 , Issue.2 , pp. 154-159
    • Johnston, B.1    Atkins, M.S.2    Mackiewich, B.3    Anderson, M.4
  • 2
    • 0023064533 scopus 로고
    • Image non-uniformity in magnetic resonance imaging: Its magnitude and methods for correction
    • Condon BR, Patterson J, Wyper D, Jenkins A, Hadley DM. Image non-uniformity in magnetic resonance imaging: its magnitude and methods for correction. Brit J Radiol 1987;60:83-7.
    • (1987) Brit J Radiol , vol.60 , pp. 83-87
    • Condon, B.R.1    Patterson, J.2    Wyper, D.3    Jenkins, A.4    Hadley, D.M.5
  • 3
    • 0027193859 scopus 로고
    • Correction of intensity nonuniformity in MR images of any orientation
    • Wicks DAG, Barker GJ, Tofts PS. Correction of intensity nonuniformity in MR images of any orientation. Magn Reson Imaging 1993; 11:183-96.
    • (1993) Magn Reson Imaging , vol.11 , pp. 183-196
    • Wicks, D.A.G.1    Barker, G.J.2    Tofts, P.S.3
  • 4
    • 0027607954 scopus 로고
    • Polynomial modeling and reduction of RF body coil spatial inhomogeneity in MRI
    • Tincher M, Meyer CR, Gupta R, Williams DM. Polynomial modeling and reduction of RF body coil spatial inhomogeneity in MRI. IEEE Trans Medical Imaging 1993;12(2):361-5.
    • (1993) IEEE Trans Medical Imaging , vol.12 , Issue.2 , pp. 361-365
    • Tincher, M.1    Meyer, C.R.2    Gupta, R.3    Williams, D.M.4
  • 5
    • 0027850154 scopus 로고
    • Correction of intensity variations in MR images for computer-aided tissue classification
    • Dawant BM, Zijdenbos AP, Margolin RA. Correction of intensity variations in MR images for computer-aided tissue classification. IEEE Trans Medical Imaging 1993;12(4):770-81.
    • (1993) IEEE Trans Medical Imaging , vol.12 , Issue.4 , pp. 770-781
    • Dawant, B.M.1    Zijdenbos, A.P.2    Margolin, R.A.3
  • 6
    • 0029263826 scopus 로고
    • Retrospective correction of intensity inhomogeneities in MRI
    • Meyer CR, Bland PH, Pipe J. Retrospective correction of intensity inhomogeneities in MRI. IEEE Trans Medical Imaging 1995;14(1):36-41.
    • (1995) IEEE Trans Medical Imaging , vol.14 , Issue.1 , pp. 36-41
    • Meyer, C.R.1    Bland, P.H.2    Pipe, J.3
  • 7
    • 0033252673 scopus 로고    scopus 로고
    • A new variational shape-from-orientation approach to correcting intensity inhomogeneities in MR images
    • Lai S-H, Fang M. A new variational shape-from-orientation approach to correcting intensity inhomogeneities in MR images. Medical Image Analysis 1999;3(4):409-24.
    • (1999) Medical Image Analysis , vol.3 , Issue.4 , pp. 409-424
    • Lai, S.-H.1    Fang, M.2
  • 9
    • 0032639736 scopus 로고    scopus 로고
    • Robust and efficient image alignment with spatially-varying illumination models
    • Fort Collins, Colorado, June 23-25
    • Lai S-H, Fang M. Robust and efficient image alignment with spatially-varying illumination models. Proceedings of IEEE Conference on Computer Vision & Pattern Recognition, vol. 2, pp. 167-172, Fort Collins, Colorado, June 23-25, 1999.
    • (1999) Proceedings of IEEE Conference on Computer Vision & Pattern Recognition , vol.2 , pp. 167-172
    • Lai, S.-H.1    Fang, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.