메뉴 건너뛰기




Volumn 26, Issue 4, 2011, Pages 255-260

Review of a large clinical series: Focused bedside echocardiography in the surgical intensive care unit: Comparison of 3 methods to estimate cardiac index

Author keywords

echocardiography; surgical ICU; trauma; ultrasonography

Indexed keywords

ACCURACY; ADULT; CLINICAL ARTICLE; COHORT ANALYSIS; DEVICE; ECHOCARDIOGRAPHY; EMERGENCY HEALTH SERVICE; EMERGENCY SURGERY; FEMALE; GENERAL SURGERY; HEART INDEX; HEART LEFT VENTRICLE OUTFLOW TRACT; HEART STROKE VOLUME; HUMAN; INTENSIVE CARE UNIT; INTERMETHOD COMPARISON; MALE; OBSERVATIONAL STUDY; PRIORITY JOURNAL; PROSPECTIVE STUDY; PULMONARY ARTERY CATHETER; REVIEW; ULTRASOUND; AGED; ARTICLE; COMPARATIVE STUDY; CONFIDENCE INTERVAL; CRITICAL ILLNESS; ECHOGRAPHY; HEALTH SURVEY; HEART DISEASE; HOSPITAL DEPARTMENT; HOSPITAL INFORMATION SYSTEM; MIDDLE AGED; PROPENSITY SCORE;

EID: 80052098496     PISSN: 08850666     EISSN: 15251489     Source Type: Journal    
DOI: 10.1177/0885066610389973     Document Type: Review
Times cited : (15)

References (23)
  • 2
    • 34547629922 scopus 로고    scopus 로고
    • A suggested curriculum in echocardiography for critical care physicians
    • Mazraeshahi R., Farmer JC, Porembka D. A suggested curriculum in echocardiography for critical care physicians. Crit Care Med. 2007 ; 35 (8). S431 - S433.
    • (2007) Crit Care Med , vol.35 , Issue.8
    • Mazraeshahi, R.1    Farmer, J.C.2    Porembka, D.3
  • 3
    • 34247538449 scopus 로고    scopus 로고
    • Specific skill set and goals of focused echocardiography for critical care clinicians
    • Beaulieu Y. Specific skill set and goals of focused echocardiography for critical care clinicians. Crit Care Med. 2007 ; 25 (5). S144 - S149.
    • (2007) Crit Care Med , vol.25 , Issue.5
    • Beaulieu, Y.1
  • 5
    • 38449087991 scopus 로고    scopus 로고
    • Intensivist bedside ultrasound (INBU) for volume assessment in the intensive care unit: A pilot study
    • Carr B., Dean AJ, Everett WW, et al. Intensivist bedside ultrasound (INBU) for volume assessment in the intensive care unit: a pilot study. J Trauma. 2007 ; 63 (3). 495-502.
    • (2007) J Trauma , vol.63 , Issue.3 , pp. 495-502
    • Carr, B.1    Dean, A.J.2    Everett, W.W.3
  • 6
    • 29144484122 scopus 로고    scopus 로고
    • Intensivists should use bedside echocardiography (multiple letters) [3]
    • DOI 10.1097/01.CCM.0000191253.35676.71
    • Souza LF Intensivists should use bedside echocardiography. Crit Care Med. 2005 ; 33 (12). 2858-2859. (Pubitemid 41816431)
    • (2005) Critical Care Medicine , vol.33 , Issue.12 , pp. 2858-2859
    • Souza, L.F.1    Pinsky, M.R.2    Vincent, J.-L.3
  • 7
    • 67650317474 scopus 로고    scopus 로고
    • Accuracy of cardiac function and volume status estimates using the bedside echocardiographic assessment in trauma / critical care: The BEAT exam
    • Gunst MA, Ghaemmaghami V., Frankel HF, et al. Accuracy of cardiac function and volume status estimates using the bedside echocardiographic assessment in trauma / critical care: the BEAT exam. J Trauma. 2008 ; 65: 509-516.
    • (2008) J Trauma , vol.65 , pp. 509-516
    • Gunst, M.A.1    Ghaemmaghami, V.2    Frankel, H.F.3
  • 9
    • 0020044725 scopus 로고
    • Unreliability of M-mode left ventricular dimensions for calculating stroke volume and cardiac output in patients without heart disease
    • Rasmussen S., Corya BC, Phillips JF, Black MJ Unreliability of M-Mode left ventricular dimensions for calculating stroke volume and cardiac output in patients without heart disease. Chest. 1982 ; 81 (5). 614-619. (Pubitemid 12112334)
    • (1982) Chest , vol.81 , Issue.5 , pp. 614-619
    • Rasmussen, S.1    Corya, B.C.2    Phillips, J.F.3    Black, M.J.4
  • 10
    • 0004149569 scopus 로고    scopus 로고
    • 6th ed. Philadelphia, PA: Lea & Febiger;
    • Feigenbaum H. Echocardiography. 6th ed. Philadelphia, PA: Lea & Febiger ; 2004.
    • (2004) Echocardiography
    • Feigenbaum, H.1
  • 11
    • 34547699294 scopus 로고    scopus 로고
    • Validation of a new arterial pulse contour-based cardiac output device
    • DOI 10.1097/01.CCM.0000275429.45312.8C, PII 0000324620070800000014
    • de Waal E., Kalkman C., Rex S., Buhre W. Validation of a new arterial pulse contour-based cardiac output device. Crit Care Med. 2007 ; 35 (8). 1904-1909. (Pubitemid 47220365)
    • (2007) Critical Care Medicine , vol.35 , Issue.8 , pp. 1904-1909
    • De Waal, E.E.C.1    Kalkman, C.J.2    Rex, S.3    Buhre, W.F.4
  • 12
    • 39749138803 scopus 로고    scopus 로고
    • Cardiac output derived from arterial pressure waveform analysis in patients undergoing cardiac surgery: Validity of a second generation device
    • DOI 10.1213/ane.0b013e318161964d, PII 0000053920080300000027
    • Mayer J., Boldt J., Wolf MW, Lang J., Suttner S. Cardiac output derived from arterial pressure waveform analysis in patients undergoing cardiac surgery: validity of a second generation device. Anesth Analg. 2008 ; 106 (3). 867-872. (Pubitemid 351301408)
    • (2008) Anesthesia and Analgesia , vol.106 , Issue.3 , pp. 867-872
    • Mayer, J.1    Boldt, J.2    Wolf, M.W.3    Lang, J.4    Suttner, S.5
  • 13
    • 33847753396 scopus 로고    scopus 로고
    • Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: A comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery
    • DOI 10.1093/bja/ael341
    • Mayer J., Boldt J., Schöllhorn T., Röhm KD, Mengistu AM, Suttner S. Semi-invasive monitoring of cardiac output by a device using arterial pressure waveform analysis: a comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery. Br J Anaesth. 2007 ; 98 (2). 176-182. (Pubitemid 47071996)
    • (2007) British Journal of Anaesthesia , vol.98 , Issue.2 , pp. 176-182
    • Mayer, J.1    Boldt, J.2    Schollhorn, T.3    Rohm, K.D.4    Mengistu, A.M.5    Suttner, S.6
  • 14
    • 42449103530 scopus 로고    scopus 로고
    • Cardiac output measurements in patients undergoing liver transplantation: Pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis
    • Biais M., Nouette-Gaulain K., Cottenceau V., et al. Cardiac output measurements in patients undergoing liver transplantation: pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis. Anesth Analg. 2008 ; 105 (5). 1480-1486.
    • (2008) Anesth Analg , vol.105 , Issue.5 , pp. 1480-1486
    • Biais, M.1    Nouette-Gaulain, K.2    Cottenceau, V.3
  • 15
    • 59649129889 scopus 로고    scopus 로고
    • Pressure to perform: Is cardiac output estimation from arterial waveforms good enough for routine use?
    • Gardner R., Beale R. Pressure to perform: Is cardiac output estimation from arterial waveforms good enough for routine use? Crit Care Med. 2009 ; 37 (1). 337-338.
    • (2009) Crit Care Med , vol.37 , Issue.1 , pp. 337-338
    • Gardner, R.1    Beale, R.2
  • 16
    • 4644296125 scopus 로고    scopus 로고
    • Transthoracic echocardiography for cardiopulmonary monitoring in intensive care
    • DOI 10.1017/S0265021504009068
    • Jensen M., Sloth E., Larsen K., Schmidt M. Transthoracic echocardiography for cardiopulmonary monitoring in intensive care. Eur J Anaesth. 2004 ; 21 (9). 700-707. (Pubitemid 39572293)
    • (2004) European Journal of Anaesthesiology , vol.21 , Issue.9 , pp. 700-707
    • Jensen, M.B.1    Sloth, E.2    Larsen, K.M.3    Schmidt, M.B.4
  • 17
    • 0016439546 scopus 로고
    • Echocardiographic examination of the left ventricle
    • Feigenbaum H. Echocardiographic examination of the left ventricle. Circulation. 1975 ; 51: 1-7.
    • (1975) Circulation , vol.51 , pp. 1-7
    • Feigenbaum, H.1
  • 20
    • 0024496914 scopus 로고
    • Determination of cardiac output in critically ill patients by dual beam Doppler echocardiography
    • Loonyenga DS, Liebson PR, Liebson PR, Bone RC, Balk RA Determination of cardiac output in critically ill patients by dual beam Doppler echocardiography. J Am Coll Cardiol. 1989 ; 13 (2). 340-347.
    • (1989) J Am Coll Cardiol , vol.13 , Issue.2 , pp. 340-347
    • Loonyenga, D.S.1    Liebson, P.R.2    Liebson, P.R.3    Bone, R.C.4    Balk, R.A.5
  • 23
    • 0024723470 scopus 로고
    • Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms
    • Schiller NB, Shah PM, Crawford M., et al. Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms. J Am Soc Echo. 1989 ; 2 (5). 358-367.
    • (1989) J Am Soc Echo , vol.2 , Issue.5 , pp. 358-367
    • Schiller, N.B.1    Shah, P.M.2    Crawford, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.