메뉴 건너뛰기




Volumn 80, Issue 959, 2007, Pages 911-918

Analysis of streak artefacts on CT images using statistics of extremes

Author keywords

[No Author keywords available]

Indexed keywords

POLYMER;

EID: 36749046235     PISSN: 00071285     EISSN: None     Source Type: Journal    
DOI: 10.1259/bjr/93741044     Document Type: Article
Times cited : (15)

References (23)
  • 2
    • 0036720768 scopus 로고    scopus 로고
    • Lung: Feasibility of a method for changing tube current during low-dose helical CT
    • Itoh S, Ikeda M, Mori Y, Suzuki K, Sawaki A, Iwano S, et al. Lung: feasibility of a method for changing tube current during low-dose helical CT. Radiology 2002;224:905-12.
    • (2002) Radiology , vol.224 , pp. 905-912
    • Itoh, S.1    Ikeda, M.2    Mori, Y.3    Suzuki, K.4    Sawaki, A.5    Iwano, S.6
  • 3
    • 0042132003 scopus 로고    scopus 로고
    • Comparison of low-dose and standard-dose helical CT in the evaluation of pulmonary nodules
    • Karabulut N, Törü M, Gelebek V, Gülsün M, Ariyurek OM. Comparison of low-dose and standard-dose helical CT in the evaluation of pulmonary nodules. Eur Radiol 2002;12: 2764-9.
    • (2002) Eur Radiol , vol.12 , pp. 2764-2769
    • Karabulut, N.1    Törü, M.2    Gelebek, V.3    Gülsün, M.4    Ariyurek, O.M.5
  • 4
    • 12144261858 scopus 로고    scopus 로고
    • Detection of pulmonary nodules at multirow-detector CT: Effectiveness of double reading to improve sensitivity at standard-dose and low-dose chest CT
    • Wormanns D, Ludwig K, Beyer F, Heindel W, Diederich S. Detection of pulmonary nodules at multirow-detector CT: effectiveness of double reading to improve sensitivity at standard-dose and low-dose chest CT. Eur Radiol 2005;15:14-22.
    • (2005) Eur Radiol , vol.15 , pp. 14-22
    • Wormanns, D.1    Ludwig, K.2    Beyer, F.3    Heindel, W.4    Diederich, S.5
  • 5
    • 24044456338 scopus 로고    scopus 로고
    • Multislice CT of the pelvis: Dose reduction with regard to image quality using 16-row CT
    • Gurung J, Khan MF, Maataoui A, Herzog C, Bux R, Bratzke H, et al. Multislice CT of the pelvis: dose reduction with regard to image quality using 16-row CT. Eur Radiol 2005;15:1898-905.
    • (2005) Eur Radiol , vol.15 , pp. 1898-1905
    • Gurung, J.1    Khan, M.F.2    Maataoui, A.3    Herzog, C.4    Bux, R.5    Bratzke, H.6
  • 6
    • 0033801768 scopus 로고    scopus 로고
    • Low-dose high-resolution CT of the chest in children and young adults: Dose, cooperation, artifact incidence, and image quality
    • Lucaya J, Piqueras J, Garcia-Pena P, Enriquez G, Garcia-Macias M, Sotil J. Low-dose high-resolution CT of the chest in children and young adults: dose, cooperation, artifact incidence, and image quality. AJR Am J Roentgenol 2000;175:985-92.
    • (2000) AJR Am J Roentgenol , vol.175 , pp. 985-992
    • Lucaya, J.1    Piqueras, J.2    Garcia-Pena, P.3    Enriquez, G.4    Garcia-Macias, M.5    Sotil, J.6
  • 8
    • 85087600531 scopus 로고    scopus 로고
    • Artifact in CT: Recognition and avoidance
    • Barrett FF, Keat N. Artifact in CT: recognition and avoidance. Radiographics 2004;24:1697-91.
    • (2004) Radiographics , vol.24 , pp. 1697-1691
    • Barrett, F.F.1    Keat, N.2
  • 9
    • 0031794571 scopus 로고    scopus 로고
    • Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise
    • Hsieh J. Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise. Med Phys 1998;25:2139-47.
    • (1998) Med Phys , vol.25 , pp. 2139-2147
    • Hsieh, J.1
  • 10
    • 0037600566 scopus 로고    scopus 로고
    • Can noise reduction filters improve low-radiation-dose chest CT images? Pilot study
    • Kalra MK, Wittram C, Maher MM, Sharma A, Avinash GB, Karau K, et al. Can noise reduction filters improve low-radiation-dose chest CT images? Pilot study. Radiology 2003;228:257-64.
    • (2003) Radiology , vol.228 , pp. 257-264
    • Kalra, M.K.1    Wittram, C.2    Maher, M.M.3    Sharma, A.4    Avinash, G.B.5    Karau, K.6
  • 12
    • 0032712877 scopus 로고    scopus 로고
    • Petrosal bone: Coronal reconstructions from axial spiral CT data obtained with 0.5-mm collimation can replace direct coronal sequential CT scans
    • Venema HW, Phoa SS, Mirck PG, Hulsmans FJ, Majoie CB, Verbeeten B, Jr. Petrosal bone: coronal reconstructions from axial spiral CT data obtained with 0.5-mm collimation can replace direct coronal sequential CT scans. Radiologv 1999;213:375-82.
    • (1999) Radiologv , vol.213 , pp. 375-382
    • Venema, H.W.1    Phoa, S.S.2    Mirck, P.G.3    Hulsmans, F.J.4    Majoie, C.B.5    Verbeeten Jr., B.6
  • 13
    • 0026661923 scopus 로고
    • Spiral CT: Decreased spatial resolution in vivo due to broadening of section-sensitivity profile
    • Brink JA, Heiken JP, Balfe DM, Sagel SS, DiCroce J, Vannier MW. Spiral CT: decreased spatial resolution in vivo due to broadening of section-sensitivity profile. Radiology 1992;185:469-74.
    • (1992) Radiology , vol.185 , pp. 469-474
    • Brink, J.A.1    Heiken, J.P.2    Balfe, D.M.3    Sagel, S.S.4    DiCroce, J.5    Vannier, M.W.6
  • 14
    • 2942752143 scopus 로고    scopus 로고
    • Dose reduction in subsecond multislice spiral CT examination of children by online tube current modulation
    • Greess H, Lutze J, Nömayr A, Wolf H, Hothorn T, Kalender WA, et al. Dose reduction in subsecond multislice spiral CT examination of children by online tube current modulation. Eur Radiol 2004;14:995-9.
    • (2004) Eur Radiol , vol.14 , pp. 995-999
    • Greess, H.1    Lutze, J.2    Nömayr, A.3    Wolf, H.4    Hothorn, T.5    Kalender, W.A.6
  • 15
    • 24044514660 scopus 로고    scopus 로고
    • Assessment of image quality of a standard and three dose-reducing protocols in adult cranial CT
    • Gündoǧdu S, Mahmutyazicioǧlu K, Özdemir H, Savranlar A, Asil K. Assessment of image quality of a standard and three dose-reducing protocols in adult cranial CT. Eur Radiol 2005;15:1959-68.
    • (2005) Eur Radiol , vol.15 , pp. 1959-1968
    • Gündoǧdu, S.1    Mahmutyazicioǧlu, K.2    Özdemir, H.3    Savranlar, A.4    Asil, K.5
  • 16
    • 18044371018 scopus 로고    scopus 로고
    • Comparison of artifacts on coronal reformation and axial CT pulmonary angiography images using single-detector and 4- and 8-detector multidetector-row helical CT scanners
    • Boiselle PM, Hasegawa I, Nishino M, Raptopoulos V, Hatabu H. Comparison of artifacts on coronal reformation and axial CT pulmonary angiography images using single-detector and 4- and 8-detector multidetector-row helical CT scanners. Acad Radiol 2005;12:602-7.
    • (2005) Acad Radiol , vol.12 , pp. 602-607
    • Boiselle, P.M.1    Hasegawa, I.2    Nishino, M.3    Raptopoulos, V.4    Hatabu, H.5
  • 17
    • 0033754964 scopus 로고    scopus 로고
    • Thick-section reformatting of thinly collimated helical CT for reduction of skull base-related artifacts
    • Alberico RA, Loud P, Pollina J, Greco W, Patel M, Klufas R. Thick-section reformatting of thinly collimated helical CT for reduction of skull base-related artifacts. AJR Am J Roentgenol 2000;175:1361-6.
    • (2000) AJR Am J Roentgenol , vol.175 , pp. 1361-1366
    • Alberico, R.A.1    Loud, P.2    Pollina, J.3    Greco, W.4    Patel, M.5    Klufas, R.6
  • 18
    • 0035078739 scopus 로고    scopus 로고
    • Breath-hold three-dimensional CT of the liver with multi-detector row helical CT
    • Wong K, Paulson EK, Nelson RC. Breath-hold three-dimensional CT of the liver with multi-detector row helical CT. Radiology 2001;219:75-9.
    • (2001) Radiology , vol.219 , pp. 75-79
    • Wong, K.1    Paulson, E.K.2    Nelson, R.C.3
  • 19
    • 0034844656 scopus 로고    scopus 로고
    • Thin-section CT of the lung: Influence of 0.5-s gantry rotation and ECG triggering on image quality
    • Montaudon M, Berger P, Blachère H, De Boucaud L, Latrabe V, Laurent F. Thin-section CT of the lung: influence of 0.5-s gantry rotation and ECG triggering on image quality. Eur Radiol 2001;11:1681-7.
    • (2001) Eur Radiol , vol.11 , pp. 1681-1687
    • Montaudon, M.1    Berger, P.2    Blachère, H.3    De Boucaud, L.4    Latrabe, V.5    Laurent, F.6
  • 20
    • 0004255286 scopus 로고
    • New York, USA: Columbia University Press;
    • Gumbel. Statistics of extremes. New York, USA: Columbia University Press; 1958.
    • (1958) Statistics of extremes
    • Gumbel1
  • 23
    • 36749063429 scopus 로고    scopus 로고
    • Dose reduction in multidetector CT using attenuation-based online tube current modulation
    • Tack D, De Maertelaer V, Gevenois PA. Dose reduction in multidetector CT using attenuation-based online tube current modulation. AJR Am J Roentgenol 2003;187:695-701.
    • (2003) AJR Am J Roentgenol , vol.187 , pp. 695-701
    • Tack, D.1    De Maertelaer, V.2    Gevenois, P.A.3