메뉴 건너뛰기




Volumn 34, Issue 2, 2011, Pages 223-231

Erratum: ROPES eye plaque brachytherapy dosimetry for two models of 103Pd seeds (Australasian Physical and Engineering Sciences in Medicine (2011) 34 (223-231) DOI: 10.1007/s13246-011-0069-1));ROPES eye plaque brachytherapy dosimetry for two models of 103Pd seeds

Author keywords

Brachytherapy; Dosimetry; Eye plaque

Indexed keywords

DOSIMETRY; INTELLIGENT SYSTEMS; MONTE CARLO METHODS; ONCOLOGY; PALLADIUM; RADIOTHERAPY; ROPE;

EID: 80051687629     PISSN: 01589938     EISSN: None     Source Type: Journal    
DOI: 10.1007/s13246-011-0094-0     Document Type: Erratum
Times cited : (5)

References (37)
  • 1
    • 0026805980 scopus 로고
    • Ocular melanoma
    • 1395150 1:STN:280:DyaK3s%2FgvFWlsQ%3D%3D
    • C Grin-Jorgensen A Berke M Grin 1992 Ocular melanoma Dermatol Clin 10 663 668 1395150 1:STN:280:DyaK3s%2FgvFWlsQ%3D%3D
    • (1992) Dermatol Clin , vol.10 , pp. 663-668
    • Grin-Jorgensen, C.1    Berke, A.2    Grin, M.3
  • 2
    • 0038692184 scopus 로고    scopus 로고
    • Changing concepts in the management of choroidal melanoma
    • DOI 10.1016/S0002-9394(03)00265-4
    • DM Robertson 2003 Changing concepts in the management of choroidal melanoma Am J Ophthalmol 136 161 170 12834684 10.1016/S0002-9394(03)00265-4 (Pubitemid 36794509)
    • (2003) American Journal of Ophthalmology , vol.136 , Issue.1 , pp. 161-170
    • Robertson, D.M.1
  • 3
    • 0030723711 scopus 로고    scopus 로고
    • Radiation therapy for choroidal melanoma
    • DOI 10.1016/S0039-6257(97)00088-X, PII S003962579700088X
    • PT Finger 1997 Radiation therapy for choroidal melanoma Surv Ophthalmol 42 215 232 9406368 10.1016/S0039-6257(97)00088-X 1:STN:280: DyaK1c%2FmvFCnsA%3D%3D (Pubitemid 27509826)
    • (1997) Survey of Ophthalmology , vol.42 , Issue.3 , pp. 215-232
    • Finger, P.T.1
  • 5
    • 0030062421 scopus 로고    scopus 로고
    • Long term visual outcome of radiated uveal melanomas in eyes eligible for randomisation to enucleation versus brachytherapy
    • DH Char S Kroll JM Quivey J Castro 1996 Long term visual outcome of radiated uveal melanomas in eyes eligible for randomisation to enucleation versus brachytherapy Br J Ophthalmol 80 117 124 8814740 10.1136/bjo.80.2.117 1:STN:280:DyaK283ks1Cjsw%3D%3D (Pubitemid 26058543)
    • (1996) British Journal of Ophthalmology , vol.80 , Issue.2 , pp. 117-124
    • Char, D.H.1    Kroll, S.2    Quivey, J.M.3    Castro, J.4
  • 7
    • 0034933028 scopus 로고    scopus 로고
    • The COMS randomized trial of iodine 125 brachytherapy for choroidal melanoma, III: Initial mortality findings: COMS report no. 18
    • Diener-West M, Earle JD, Fine SL, Hawkins BS, Moy CS, Reynolds SM (2001) The COMS randomized trial of iodine-125 brachytherapy for choroidal melanoma. III: initial mortality findings COMS Report No. 18. Arch Ophthalmol 119:969-982 (Pubitemid 32652189)
    • (2001) Archives of Ophthalmology , vol.119 , Issue.7 , pp. 969-982
    • Hawkins, B.S.1
  • 11
    • 0019025726 scopus 로고
    • Radiotherapy of choroidal melanoma with iodine-125
    • 1:STN:280:DyaL3c3kvVOrsA%3D%3D
    • S Packer M Rotman 1980 Radiotherapy of choroidal melanoma with iodine-125 Int Ophtalmol Clin 20 135 142 1:STN:280:DyaL3c3kvVOrsA%3D%3D
    • (1980) Int Ophtalmol Clin , vol.20 , pp. 135-142
    • Packer, S.1    Rotman, M.2
  • 12
    • 0025827568 scopus 로고
    • The dose rate effect revisited: Radiobiological considerations of importance in radiotherapy
    • 1938548 10.1016/0360-3016(91)90314-T 1:STN:280:DyaK38%2FktFWntw%3D%3D
    • EJ Hall DJ Brenner 1991 The dose rate effect revisited: radiobiological considerations of importance in radiotherapy Int J Radiat Oncol Biol Phys 21 1403 1414 1938548 10.1016/0360-3016(91)90314-T 1:STN:280:DyaK38%2FktFWntw%3D%3D
    • (1991) Int J Radiat Oncol Biol Phys , vol.21 , pp. 1403-1414
    • Hall, E.J.1    Brenner, D.J.2
  • 13
    • 0033510719 scopus 로고    scopus 로고
    • Palladium-103 plaque radiotherapy for choroidal melanoma: Results of a 7-year study
    • PT Finger A Berson A Szechter 1999 Palladium-103 plaque radiotherapy for choroidal melanoma: results of a 7 years study Ophthalmology 106 606 613 10080222 10.1016/S0161-6420(99)90124-0 1:STN:280:DyaK1M7nvVejtQ%3D%3D (Pubitemid 30191600)
    • (1999) Ophthalmology , vol.106 , Issue.3 , pp. 606-613
    • Finger, P.T.1    Berson, A.2    Szechter, A.3
  • 14
    • 0026059149 scopus 로고
    • Palladium-103 ophthalmic plaque radiotherapy
    • 1755746 1:STN:280:DyaK38%2FpsFyntQ%3D%3D
    • PT Finger DM Moshfeghi TK Ho 1991 Palladium-103 ophthalmic plaque radiotherapy Arch Ophthalmol 109 1610 1613 1755746 1:STN:280: DyaK38%2FpsFyntQ%3D%3D
    • (1991) Arch Ophthalmol , vol.109 , pp. 1610-1613
    • Finger, P.T.1    Moshfeghi, D.M.2    Ho, T.K.3
  • 15
    • 77953532948 scopus 로고    scopus 로고
    • Monte Carlo calculation of dosimetry parameters for the IR08-103Pd brachytherapy source
    • 20632562 10.1118/1.3416922 1:CAS:528:DC%2BC3cXntVyks7c%3D
    • P Saidi M Sadeghi A Shirazi C Tenreiro 2010 Monte Carlo calculation of dosimetry parameters for the IR08-103Pd brachytherapy source Med Phys 37 2509 2515 20632562 10.1118/1.3416922 1:CAS:528:DC%2BC3cXntVyks7c%3D
    • (2010) Med Phys , vol.37 , pp. 2509-2515
    • Saidi, P.1    Sadeghi, M.2    Shirazi, A.3    Tenreiro, C.4
  • 17
    • 0023690416 scopus 로고
    • Effect of gold shielding on the dosimetry of an 125-I seed at close range
    • 3211059 10.1118/1.596218 1:STN:280:DyaL1M%2Fps1KmsQ%3D%3D
    • A Wu ES Sternick DJ Muise 1988 Effect of gold shielding on the dosimetry of an 125-I seed at close range Med Phys 15 627 628 3211059 10.1118/1.596218 1:STN:280:DyaL1M%2Fps1KmsQ%3D%3D
    • (1988) Med Phys , vol.15 , pp. 627-628
    • Wu, A.1    Sternick, E.S.2    Muise, D.J.3
  • 18
    • 0023878970 scopus 로고
    • 125I for ophthalmic plaque dosimetry
    • 3405144 10.1118/1.596238 1:CAS:528:DyaL1cXltVSnu7s%3D
    • 125I for ophthalmic plaque dosimetry Med Phys 15 397 400 3405144 10.1118/1.596238 1:CAS:528:DyaL1cXltVSnu7s%3D
    • (1988) Med Phys , vol.15 , pp. 397-400
    • Luxton, G.1    Astrahan, M.A.2    Petrovich, Z.3
  • 19
    • 56749095583 scopus 로고    scopus 로고
    • 103Pd eye plaque brachytherapy
    • 19175111 10.1118/1.3002412 1:CAS:528:DC%2BD1cXhsVentbnE
    • 103Pd eye plaque brachytherapy Med Phys 35 5530 5543 19175111 10.1118/1.3002412 1:CAS:528:DC%2BD1cXhsVentbnE
    • (2008) Med Phys , vol.35 , pp. 5530-5543
    • Thomson, R.M.1    Taylor, R.E.P.2    Rogers, D.W.O.3
  • 21
    • 0022559909 scopus 로고
    • 125I seed eye plaques
    • DOI 10.1118/1.595926
    • 125I seed eye plaques Med Phys 13 78 83 3814235 10.1118/1.595926 1:STN:280:DyaL287ks1eqtw%3D%3D (Pubitemid 16185625)
    • (1986) Medical Physics , vol.13 , Issue.1 , pp. 78-83
    • Weaver, K.A.1
  • 23
    • 11244354430 scopus 로고    scopus 로고
    • Dosimetric study of the 15 mm ROPES eye plaque
    • DOI 10.1118/1.1812605
    • D Granero J Perez-Calatayud F Ballester E Casal 2004 Dosimetric study of the 15 mm ROPES eye plaque Med Phys 31 3330 3336 15651616 10.1118/1.1812605 1:STN:280:DC%2BD2M%2FisVyqsw%3D%3D (Pubitemid 40064985)
    • (2004) Medical Physics , vol.31 , Issue.12 , pp. 3330-3336
    • Granero, D.1    Perez-Calatayud, J.2    Ballester, F.3    Casal, E.4    De Frutos, J.M.5
  • 25
    • 0034004934 scopus 로고    scopus 로고
    • 103Pd interstitial brachytherapy source
    • DOI 10.1118/1.598924
    • 103Pd interstitial brachytherapy source Med Phys 27 643 654 10798684 10.1118/1.598924 1:CAS:528:DC%2BD3cXjtFehtLY%3D (Pubitemid 30227039)
    • (2000) Medical Physics , vol.27 , Issue.4 , pp. 643-654
    • Williamson, J.F.1
  • 26
    • 73649091426 scopus 로고    scopus 로고
    • 103Pd eye plaque brachytherapy with various seed models
    • 20175499 10.1118/1.3271104 1:CAS:528:DC%2BC3cXisVSmug%3D%3D
    • 103Pd eye plaque brachytherapy with various seed models Med Phys 37 368 376 20175499 10.1118/1.3271104 1:CAS:528:DC%2BC3cXisVSmug%3D%3D
    • (2010) Med Phys , vol.37 , pp. 368-376
    • Thomson, R.M.1    Rogers, D.W.O.2
  • 29
    • 46149125304 scopus 로고    scopus 로고
    • 131Cs
    • DOI 10.1118/1.2940604
    • 131Cs Med Phys 35 3364 3371 18697560 10.1118/1.2940604 1:CAS:528:DC%2BD1cXnvVGqs7g%3D (Pubitemid 351904539)
    • (2008) Medical Physics , vol.35 , Issue.7 , pp. 3364-3371
    • Melhus, C.S.1    Rivard, M.J.2
  • 30
    • 0033795853 scopus 로고    scopus 로고
    • Dosimetric characteristic of the Pharma Seed model BT-125-I source
    • 11011748 10.1118/1.1289897 1:STN:280:DC%2BD3cvltlCqtQ%3D%3D
    • CC Popescu J Wise K Sowards AS Meigooni GS Ibbott 2000 Dosimetric characteristic of the Pharma Seed model BT-125-I source Med Phys 27 2174 2181 11011748 10.1118/1.1289897 1:STN:280:DC%2BD3cvltlCqtQ%3D%3D
    • (2000) Med Phys , vol.27 , pp. 2174-2181
    • Popescu, C.C.1    Wise, J.2    Sowards, K.3    Meigooni, A.S.4    Ibbott, G.S.5
  • 31
    • 0034800914 scopus 로고    scopus 로고
    • Variation in interpretation of the AAPM TG-43 geometry factor leads to unclearness in brachytherapy dosimetry
    • DOI 10.1118/1.1398563
    • E Kouwenhoven R Laarse DR Schaart 2001 Variation in interpretation of the AAPM TG-43 geometry factor leads to unclearness in brachytherapy dosimetry Med Phys 28 1965 1966 11585228 10.1118/1.1398563 1:STN:280:DC%2BD3MrjvVClsw%3D%3D (Pubitemid 32899737)
    • (2001) Medical Physics , vol.28 , Issue.9 , pp. 1965-1966
    • Kouwenhoven, E.1    Van Der Laarse, R.2    Schaart, D.R.3
  • 33
    • 36049055113 scopus 로고
    • Reevaluation of X-ray atomic energy levels
    • 10.1103/RevModPhys.39.125 1:CAS:528:DyaF2sXntVegtQ%3D%3D
    • JA Bearden AF Burr 1967 Reevaluation of X-ray atomic energy levels Rev Med Phys 39 125 142 10.1103/RevModPhys.39.125 1:CAS:528:DyaF2sXntVegtQ%3D%3D
    • (1967) Rev Med Phys , vol.39 , pp. 125-142
    • Bearden, J.A.1    Burr, A.F.2
  • 34
    • 0003414651 scopus 로고
    • Photon, electron, photon and neutron interaction data for body tissues
    • ICRU Washington DC
    • ICRU (1992) Photon, Electron, Photon and Neutron Interaction Data for Body Tissues, ICRU Report 46. ICRU, Washington DC
    • (1992) ICRU Report 46. ICRU
  • 35
    • 0032738001 scopus 로고    scopus 로고
    • 103palladium brachytherapy source
    • 10587234 10.1118/1.598765 1:CAS:528:DyaK1MXotV2gs70%3D
    • 103palladium brachytherapy source Med Phys 26 2465 2470 10587234 10.1118/1.598765 1:CAS:528:DyaK1MXotV2gs70%3D
    • (1999) Med Phys , vol.26 , pp. 2465-2470
    • Wallace, R.E.1    Fan, J.J.2
  • 36
    • 0034046524 scopus 로고    scopus 로고
    • 103Pd source
    • DOI 10.1118/1.598975
    • 103Pd source Med Phys 27 1108 1112 10841416 10.1118/1.598975 1:STN:280:DC%2BD3cvlvFylsg%3D%3D (Pubitemid 30350022)
    • (2000) Medical Physics , vol.27 , Issue.5 , pp. 1108-1112
    • Li, Z.1    Palta, J.R.2    Fan, J.J.3
  • 37
    • 0034004556 scopus 로고    scopus 로고
    • 103Pd seeds with air kerma strength calibration based upon a primary national standard
    • DOI 10.1118/1.598925
    • 103Pd seeds with air kerma strength calibration based upon a primary national standard Med Phys 27 655 658 10798685 10.1118/1.598925 1:CAS:528:DC%2BD3cXjtFehtLc%3D (Pubitemid 30227040)
    • (2000) Medical Physics , vol.27 , Issue.4 , pp. 655-658
    • Nath, R.1    Yue, N.2    Shahnazi, K.3    Bongiorni, P.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.