메뉴 건너뛰기




Volumn 37, Issue 1, 2010, Pages 368-376

Monte Carlo dosimetry for i 125 and P 103 d eye plaque brachytherapy with various seed models

Author keywords

BrachyDose; Brachytherapy; Choroidal melanoma; COMS; Dose calculation; EGSnrc; Eye plaque; Monte Carlo

Indexed keywords

DERMATOLOGY; GOLD ALLOYS; ONCOLOGY; RADIOTHERAPY; SILICONES;

EID: 73649091426     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3271104     Document Type: Article
Times cited : (39)

References (22)
  • 1
    • 0034933028 scopus 로고    scopus 로고
    • The COMS randomized trial of iodine 125 brachytherapy for choroidal melanoma. III. Initial mortality findings. COMS report no. 18
    • COMS Group, 0003-9950
    • COMS Group, " The COMS randomized trial of iodine 125 brachytherapy for choroidal melanoma. III. Initial mortality findings. COMS report no. 18.," Arch. Ophthalmol. (Chicago) 0003-9950 105, 969-982 (2001).
    • (2001) Arch. Ophthalmol. (Chicago) , vol.105 , pp. 969-982
  • 2
    • 33845474483 scopus 로고    scopus 로고
    • The COMS randomized trial of iodine 125 brachytherapy for choroidal melanoma: V. Twelve-year mortality rates and prognostic factors: COMS report no. 28
    • DOI 10.1001/archopht.124.12.1684
    • COMS Group, " The COMS randomized trial of iodine 125 brachytherapy for choroidal melanom. V. Twelve-year mortality rates and prognostic factors: COMS report no. 28.," Arch. Ophthalmol. (Chicago) 0003-9950 124, 1684-1693 (2006). 10.1001/archopht.124.12.1684 (Pubitemid 44913190)
    • (2006) Archives of Ophthalmology , vol.124 , Issue.12 , pp. 1684-1693
    • Hawkins, B.S.1
  • 3
    • 0002671289 scopus 로고
    • Ocular melanoma, I-125 plaques
    • 0094-2405, (Abs)
    • R. W. Kline and P. D. Yeakel, " Ocular melanoma, I-125 plaques.," Med. Phys. 0094-2405 14, 475 (Abs) (1987).
    • (1987) Med. Phys. , vol.14 , pp. 475
    • Kline, R.W.1    Yeakel, P.D.2
  • 4
    • 0028919251 scopus 로고
    • Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43
    • 0094-2405. 10.1118/1.597458
    • R. Nath, L. L. Anderson, G. Luxton, K. A. Weaver, J. F. Williamson, and A. S. Meigooni, " Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43.," Med. Phys. 0094-2405 22, 209-234 (1995). 10.1118/1.597458
    • (1995) Med. Phys. , vol.22 , pp. 209-234
    • Nath, R.1    Anderson, L.L.2    Luxton, G.3    Weaver, K.A.4    Williamson, J.F.5    Meigooni, A.S.6
  • 5
    • 1142304255 scopus 로고    scopus 로고
    • Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations
    • DOI 10.1118/1.1646040
    • M. J. Rivard, B. M. Coursey, L. A. DeWerd, M. S. Huq, G. S. Ibbott, M. G. Mitch, R. Nath, and J. F. Williamson, " Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations.," Med. Phys. 0094-2405 31, 633-674 (2004). 10.1118/1.1646040 (Pubitemid 38381028)
    • (2004) Medical Physics , vol.31 , Issue.3 , pp. 633-674
    • Rivard, M.J.1    Coursey, B.M.2    DeWerd, L.A.3    Hanson, W.F.4    Huq, M.S.5    Ibbott, G.S.6    Mitch, M.G.7    Nath, R.8    Williamson, J.F.9
  • 6
    • 85027229597 scopus 로고
    • COMS Group Springfield, VA, National Technical Information Service, 1999 Revision at, accessed October 15, 2009
    • COMS Group, Ch 12: Radiation Therapy, COMS Manual of Procedures PB95-179693, Springfield, VA, National Technical Information Service (1995), 1999 Revision at http://www.jhu.edu/wctb/coms/manual/coms-chap12.pdf, accessed October 15, 2009.
    • (1995) Ch 12: Radiation Therapy, COMS Manual of Procedures PB95-179693
  • 7
    • 56749095583 scopus 로고    scopus 로고
    • Monte Carlo dosimetry for i 125 and P 103 d eye plaque brachytherapy
    • 0094-2405. 10.1118/1.3002412
    • R. M. Thomson, R. E. P. Taylor, and D. W. O. Rogers, " Monte Carlo dosimetry for I 125 and P 103 d eye plaque brachytherapy.," Med. Phys. 0094-2405 35, 5530-5543 (2008). 10.1118/1.3002412
    • (2008) Med. Phys. , vol.35 , pp. 5530-5543
    • Thomson, R.M.1    Taylor, R.E.P.2    Rogers, D.W.O.3
  • 8
    • 46149125304 scopus 로고    scopus 로고
    • 131Cs
    • DOI 10.1118/1.2940604
    • C. S. Melhus and M. J. Rivard, " COMS eye plaque brachytherapy dosimetry simulations for P 103 d, I 125, and C 131 s.," Med. Phys. 0094-2405 35, 3364-3371 (2008). 10.1118/1.2940604 (Pubitemid 351904539)
    • (2008) Medical Physics , vol.35 , Issue.7 , pp. 3364-3371
    • Melhus, C.S.1    Rivard, M.J.2
  • 9
    • 0029665666 scopus 로고    scopus 로고
    • 125I eye plaque dose distribution including penumbra characteristics
    • DOI 10.1118/1.597803
    • A. de la Zerda, S. Chiu-Tsao, J. Lin, L. L. Boulay, I. Kanna, J. H. Kim, and H. Tsao, " I 125 plaque dose distribution including penumbra characteristics.," Med. Phys. 0094-2405 23, 407-418 (1996). 10.1118/1.597803 (Pubitemid 26095697)
    • (1996) Medical Physics , vol.23 , Issue.3 , pp. 407-418
    • De La Zerda, A.1    Chiu-Tsao, S.-T.2    Lin, J.3    Boulay, L.L.4    Kanna, I.5    Jae Ho Kim6    Tsao, H.-S.7
  • 10
    • 58149123817 scopus 로고    scopus 로고
    • Spectroscopic output of i 125 and P 103 d low dose rate brachytherapy sources
    • 0094-2405. 10.1118/1.3039789
    • J. Usher-Moga, S. M. Beach, and L. A. DeWerd, " Spectroscopic output of I 125 and P 103 d low dose rate brachytherapy sources.," Med. Phys. 0094-2405 36, 270-278 (2009). 10.1118/1.3039789
    • (2009) Med. Phys. , vol.36 , pp. 270-278
    • Usher-Moga, J.1    Beach, S.M.2    Dewerd, L.A.3
  • 11
    • 34748860292 scopus 로고    scopus 로고
    • Silver fluorescent x-ray yield and its influence on the dose rate constant for nine low-energy brachytherapy source models
    • DOI 10.1118/1.2775665
    • R. Nath and Z. J. Chen, " Silver fluorescent x-ray yield and its influence on the dose rate constant for nine low-energy brachytherapy source models.," Med. Phys. 0094-2405 34, 3785-3793 (2007). 10.1118/1.2775665 (Pubitemid 47482880)
    • (2007) Medical Physics , vol.34 , Issue.10 , pp. 3785-3793
    • Nath, R.1    Chen, Z.J.2
  • 12
    • 48349124498 scopus 로고    scopus 로고
    • A Monte Carlo study on the effect of seed design on the interseed attenuation in permanent prostate implants
    • 0094-2405. 10.1118/1.2955754
    • H. Afsharpour, M. D'Amours, B. Cot́, J. -F. Carrier, F. Verhaegen, and L. Beaulieu, " A Monte Carlo study on the effect of seed design on the interseed attenuation in permanent prostate implants.," Med. Phys. 0094-2405 35, 3671-3681 (2008). 10.1118/1.2955754
    • (2008) Med. Phys. , vol.35 , pp. 3671-3681
    • Afsharpour, H.1    D'Amours, M.2    Cot́, B.3    Carrier, J.-F.4    Verhaegen, F.5    Beaulieu, L.6
  • 14
    • 0034104708 scopus 로고    scopus 로고
    • Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version
    • DOI 10.1118/1.598917
    • I. Kawrakow, " Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version.," Med. Phys. 0094-2405 27, 485-498 (2000). 10.1118/1.598917 (Pubitemid 30171797)
    • (2000) Medical Physics , vol.27 , Issue.3 , pp. 485-498
    • Kawrakow, I.1
  • 15
    • 33846646281 scopus 로고    scopus 로고
    • A fast Monte Carlo code for multi-seed brachytherapy treatments including interseed effects
    • 0094-2405, (Abs)
    • G. Yegin and D. W. O. Rogers, " A fast Monte Carlo code for multi-seed brachytherapy treatments including interseed effects.," Med. Phys. 0094-2405 31, 1771 (Abs) (2004).
    • (2004) Med. Phys. , vol.31 , pp. 1771
    • Yegin, G.1    Rogers, D.W.O.2
  • 16
    • 85024783701 scopus 로고    scopus 로고
    • BrachyDose: A new fast Monte Carlo code for brachytherapy calculations
    • 0094-2405, (Abs). 10.1118/1.2241038
    • G. Yegin, R. E. P. Taylor, and D. W. O. Rogers, " BrachyDose: A new fast Monte Carlo code for brachytherapy calculations.," Med. Phys. 0094-2405 33, 2074 (Abs) (2006). 10.1118/1.2241038
    • (2006) Med. Phys. , vol.33 , pp. 2074
    • Yegin, G.1    Taylor, R.E.P.2    Rogers, D.W.O.3
  • 18
    • 33846566263 scopus 로고    scopus 로고
    • Benchmarking BrachyDose: Voxel based EGSnrc Monte Carlo calculations of TG-43 dosimetry parameters
    • DOI 10.1118/1.2400843
    • R. E. P. Taylor, G. Yegin, and D. W. O. Rogers, " Benchmarking BrachyDose: Voxel-based EGSnrc Monte Carlo calculations of TG-43 dosimetry parameters.," Med. Phys. 0094-2405 34, 445-457 (2007). 10.1118/1.2400843 (Pubitemid 46185122)
    • (2007) Medical Physics , vol.34 , Issue.2 , pp. 445-457
    • Taylor, R.E.P.1    Yegin, G.2    Rogers, D.W.O.3
  • 19
    • 50449095484 scopus 로고    scopus 로고
    • An EGSnrc Monte Carlo-calculated database of TG-43 parameters
    • 0094-2405. 10.1118/1.2965360
    • R. E. P. Taylor and D. W. O. Rogers, " An EGSnrc Monte Carlo-calculated database of TG-43 parameters.," Med. Phys. 0094-2405 35, 4228-4241 (2008). 10.1118/1.2965360
    • (2008) Med. Phys. , vol.35 , pp. 4228-4241
    • Taylor, R.E.P.1    Rogers, D.W.O.2
  • 21
    • 14844310231 scopus 로고    scopus 로고
    • Improved treatment planning for COMS eye plaques
    • 0360-3016. 10.1016/j.ijrob2004.09.062
    • M. A. Astrahan, " Improved treatment planning for COMS eye plaques.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 61, 1227-1242 (2005). 10.1016/j.ijrobp.2004.09.062
    • (2005) Int. J. Radiat. Oncol., Biol., Phys. , vol.61 , pp. 1227-1242
    • Astrahan, M.A.1
  • 22
    • 73649138015 scopus 로고    scopus 로고
    • personal communication
    • S. Chiu-Tsao, personal communication (2009).
    • (2009)
    • Chiu-Tsao, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.