-
2
-
-
1142304255
-
Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations
-
0094-2405 10.1118/1.1646040
-
M. J. Rivard, B. M. Coursey, L. A. DeWerd, W. F. Hanson, M. S. Huq, G. S. Ibbott, M. G. Mitch, R. Nath, and J. F. Williamson, " Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations., " Med. Phys. 0094-2405 10.1118/1.1646040 31, 633-674 (2004).
-
(2004)
Med. Phys.
, vol.31
, pp. 633-674
-
-
Rivard, M.J.1
Coursey, B.M.2
Dewerd, L.A.3
Hanson, W.F.4
Huq, M.S.5
Ibbott, G.S.6
Mitch, M.G.7
Nath, R.8
Williamson, J.F.9
-
3
-
-
0028919251
-
Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43
-
0094-2405 10.1118/1.597458
-
R. Nath, L. L. Anderson, G. Luxton, K. A. Weaver, J. F. Williamson, and A. S. Meigooni, " Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43., " Med. Phys. 0094-2405 10.1118/1.597458 22, 209-234 (1995).
-
(1995)
Med. Phys.
, vol.22
, pp. 209-234
-
-
Nath, R.1
Anderson, L.L.2
Luxton, G.3
Weaver, K.A.4
Williamson, J.F.5
Meigooni, A.S.6
-
4
-
-
85027239632
-
Monte Carlo and experimental characterization of the first AMIRS P 103 d brachytherapy source
-
G. Raisali, M. G. Ghonchehnazi, P. Shokrani, and M. Sadeghi, " Monte Carlo and experimental characterization of the first AMIRS P 103 d brachytherapy source., " Appl. Radiat. Isot. (submitted).
-
Appl. Radiat. Isot.
-
-
Raisali, G.1
Ghonchehnazi, M.G.2
Shokrani, P.3
Sadeghi, M.4
-
5
-
-
0036315661
-
Preparation of P 103 d seed-molecular plating of P 103 d onto silver rod
-
0969-8043
-
Ch. Zhang, Y. Wang, H. Tian, and D. Yin, " Preparation of P 103 d seed-molecular plating of P 103 d onto silver rod., " Appl. Radiat. Isot. 57, 309-311 (2002). 0969-8043
-
(2002)
Appl. Radiat. Isot.
, vol.57
, pp. 309-311
-
-
Zhang, Ch.1
Wang, Y.2
Tian, H.3
Yin, D.4
-
6
-
-
85027228559
-
-
PTW, Ionizing Radiation Product Catalog
-
PTW, Ionizing Radiation Product Catalog 2004/2005, available at http://www.ptw.de/fileadmin/data/download/catalogs/ Ionizing_Radiation_Cat_en_58721100_01.pdf.
-
(2004)
-
-
-
7
-
-
85027237251
-
-
National Institute of Standards and Technology (NIST) database, available online at
-
National Institute of Standards and Technology (NIST) database, available online at http://physics.nist.gov/cgi-bin/Star/compos.pl?matno=223.
-
-
-
-
8
-
-
0033805914
-
Experimental determination of dosimetric characteristics of Best® I 125 brachytherapy source
-
0094-2405 10.1118/1.1289256
-
A. S. Meigooni, D. M. Gearheart, and K. Sowards, " Experimental determination of dosimetric characteristics of Best® I 125 brachytherapy source., " Med. Phys. 0094-2405 10.1118/1.1289256 27, 2168-2173 (2000).
-
(2000)
Med. Phys.
, vol.27
, pp. 2168-2173
-
-
Meigooni, A.S.1
Gearheart, D.M.2
Sowards, K.3
-
9
-
-
85027241422
-
-
Los Alamos National Laboratory Report No. LA-13709-M, March
-
J. F. Briesmeister, "MCNP-A general Monte Carlo N -particle transport code-Version 4C," Los Alamos National Laboratory Report No. LA-13709-M, March 2000.
-
(2000)
-
-
Briesmeister, J.F.1
-
10
-
-
0035055314
-
Monte Carlo calculation of AAPM Task Group Report No.43 dosimetry parameters for the MED3631-A/M I 125 source
-
0094-2405 10.1118/1.1355306
-
M. J. Rivard, " Monte Carlo calculation of AAPM Task Group Report No.43 dosimetry parameters for the MED3631-A/M I 125 source., " Med. Phys. 0094-2405 10.1118/1.1355306 28, 629-637 (2001).
-
(2001)
Med. Phys.
, vol.28
, pp. 629-637
-
-
Rivard, M.J.1
-
11
-
-
0029062568
-
Experimental validation of Monte Carlo dose calculation about a high-intensity I 192 r source for pulsed dose rate brachytherapy
-
0094-2405 10.1118/1.597484
-
R. K. Valicenti, A. S. Kirov, A. S. Meigooni, V. Mishra, R. K. Das, and J. F. Williamson, " Experimental validation of Monte Carlo dose calculation about a high-intensity I 192 r source for pulsed dose rate brachytherapy., " Med. Phys. 0094-2405 10.1118/1.597484 22, 821-830 (1995).
-
(1995)
Med. Phys.
, vol.22
, pp. 821-830
-
-
Valicenti, R.K.1
Kirov, A.S.2
Meigooni, A.S.3
Mishra, V.4
Das, R.K.5
Williamson, J.F.6
-
12
-
-
0033795853
-
Dosimetric characteristics of the Pharma Seed model BT-125-I source
-
0094-2405 10.1118/1.1289897
-
C. C. Popescu, J. Wise, K. Sowards, A. S. Meigooni, and G. S. Ibbott, " Dosimetric characteristics of the Pharma Seed model BT-125-I source., " Med. Phys. 0094-2405 10.1118/1.1289897 27, 2174-2181 (2000).
-
(2000)
Med. Phys.
, vol.27
, pp. 2174-2181
-
-
Popescu, C.C.1
Wise, J.2
Sowards, K.3
Meigooni, A.S.4
Ibbott, G.S.5
-
13
-
-
0034004934
-
Monte Carlo modeling of the transverse-axis dose distribution of the model 200 P 103 d interstitial brachytherapy source
-
0094-2405 10.1118/1.598924
-
J. F. Williamson, " Monte Carlo modeling of the transverse-axis dose distribution of the model 200 P 103 d interstitial brachytherapy source., " Med. Phys. 0094-2405 10.1118/1.598924 27, 643-654 (2000).
-
(2000)
Med. Phys.
, vol.27
, pp. 643-654
-
-
Williamson, J.F.1
-
14
-
-
33744533962
-
Theoritical and experimental determination of dosimetric characterization for ADVANTAGE™ Pd-103 brachytherapy source
-
0969-8043
-
A. S. Meigooni, Sh. A. Dini, Sh. B. Awan, K. Dou, and R. A. Koona, " Theoritical and experimental determination of dosimetric characterization for ADVANTAGE™ Pd-103 brachytherapy source., " Appl. Radiat. Isot. 64, 881-887 (2006). 0969-8043
-
(2006)
Appl. Radiat. Isot.
, vol.64
, pp. 881-887
-
-
Meigooni, A.S.1
Dini Sh., A.2
Awan Sh., B.3
Dou, K.4
Koona, R.A.5
-
15
-
-
0034004556
-
Measurement of dose-rate constant for P 103 d seeds with air kerma strength calibration based upon a primary national standard
-
0094-2405 10.1118/1.598925
-
R. Nath, N. Yue, K. Shahnazi, and P. J. Bongiorni, " Measurement of dose-rate constant for P 103 d seeds with air kerma strength calibration based upon a primary national standard., " Med. Phys. 0094-2405 10.1118/1.598925 27, 655-658 (2000).
-
(2000)
Med. Phys.
, vol.27
, pp. 655-658
-
-
Nath, R.1
Yue, N.2
Shahnazi, K.3
Bongiorni, P.J.4
-
16
-
-
0032738001
-
Dosimetric characterization of a new design 103palladium brachytherapy source
-
0094-2405 10.1118/1.598765
-
R. E. Wallace and J. J. Fan, " Dosimetric characterization of a new design 103palladium brachytherapy source., " Med. Phys. 0094-2405 10.1118/1.598765 26, 2465-2470 (1999).
-
(1999)
Med. Phys.
, vol.26
, pp. 2465-2470
-
-
Wallace, R.E.1
Fan, J.J.2
-
17
-
-
0033625386
-
Dosimetric characteristics of the Intersource p 130 alladium brachytherapy source
-
0094-2405 10.1118/1.598991
-
A. S. Meigooni, K. Sowards, and M. Soldano, " Dosimetric characteristics of the Intersource p 130 alladium brachytherapy source., " Med. Phys. 0094-2405 10.1118/1.598991 27, 1093-1099 (2000).
-
(2000)
Med. Phys.
, vol.27
, pp. 1093-1099
-
-
Meigooni, A.S.1
Sowards, K.2
Soldano, M.3
-
18
-
-
0035543812
-
Dosimetric characteristics of the Best® double-wall P 103 d brachytherapy source
-
0094-2405 10.1118/1.1414007
-
A. S. Meigooni, Z. Bharucha, M. Yoe-Sein, and K. Sowards, " Dosimetric characteristics of the Best® double-wall P 103 d brachytherapy source., " Med. Phys. 0094-2405 10.1118/1.1414007 28, 2568-2575 (2001).
-
(2001)
Med. Phys.
, vol.28
, pp. 2568-2575
-
-
Meigooni, A.S.1
Bharucha, Z.2
Yoe-Sein, M.3
Sowards, K.4
-
19
-
-
0032217054
-
Anisotropy functions for 125I and P 103 d sources
-
0094-2405 10.1118/1.598458
-
K. Weaver, " Anisotropy functions for 125I and P 103 d sources., " Med. Phys. 0094-2405 10.1118/1.598458 25, 2271-2278 (1998).
-
(1998)
Med. Phys.
, vol.25
, pp. 2271-2278
-
-
Weaver, K.1
-
20
-
-
0034046524
-
Monte Carlo calculations and experimental measurements of dosimetry parameters of a new P 103 d source
-
0094-2405 10.1118/1.598975
-
Z. Li, J. R. Palta, and J. J. Fan, " Monte Carlo calculations and experimental measurements of dosimetry parameters of a new P 103 d source., " Med. Phys. 0094-2405 10.1118/1.598975 27, 1108-1112 (2000).
-
(2000)
Med. Phys.
, vol.27
, pp. 1108-1112
-
-
Li, Z.1
Palta, J.R.2
Fan, J.J.3
|