Reconstruction of high-resolution 3D dose from matrix measurements: Error detection capability of the COMPASS correction kernel method

Author keywords

[No Author keywords available]

Indexed keywords

2D MEASUREMENT; CORRECTION METHOD; DETECTION CAPABILITY; DOSE RECONSTRUCTION; FLUENCES; HIGH RESOLUTION; INTENSITY-MODULATED RADIOTHERAPY; KERNEL METHODS; LEAF POSITION; LIMITED RESOLUTION; MATRIX; POSITION ERRORS; POSITIONING ERROR; REFERENCE DOSE; SMALL AREA; TREATMENT PLANS;

EID: 79961087515     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/56/15/023     Document Type: Article
Times cited : (44)

References (21)
  • 1
    • 0024424112 scopus 로고
    • Collapsed cone convolution of radiant energy for photon dose calculation in heterogeneous media
    • DOI 10.1118/1.596360
    • Ahnesjo A 1989 Collapsed cone convolution of radiant energy for photon dose calculation in heterogeneous media Med. Phys. 16 577-92 (Pubitemid 19224308)
    • (1989) Medical Physics , vol.16 , Issue.4 , pp. 577-592
    • Ahnesjo, A.1
  • 5
    • 0035889335 scopus 로고    scopus 로고
    • Intensity-modulated radiotherapy: Current status and issues of interest
    • Boyer A L et al 2001 Intensity-modulated radiotherapy: current status and issues of interest Int. J. Radiat. Oncol. Biol. Phys. 51 880-914
    • (2001) Int. J. Radiat. Oncol. Biol. Phys. , vol.51 , pp. 880-914
    • Boyer, A.L.1
  • 6
    • 14644406160 scopus 로고    scopus 로고
    • A Fourier analysis of the dose grid resolution required for accurate IMRT fluence map optimization
    • DOI 10.1118/1.1843354
    • Dempsey J F, Romeijn H E, Li J G and Palta J R 2005 A Fourier analysis of the dose grid resolution required for accurate IMRT fluence map optimization Med. Phys. 32 380-8 (Pubitemid 40322318)
    • (2005) Medical Physics , vol.32 , Issue.2 , pp. 380-388
    • Dempsey, J.F.1    Romeijn, H.E.2    Li, J.G.3    Low, D.A.4    Palta, J.R.5
  • 7
    • 10744231470 scopus 로고    scopus 로고
    • Guidance document on delivery, treatment planning, and clinical implementation of IMRT: Report of the IMRT subcommittee of the AAPM radiation therapy committee
    • DOI 10.1118/1.1591194
    • Ezzell G A, Galvin J M, Low D, Palta J R, Rosen I, Sharpe M B, Xia P, Xiao Y, Xing L and Yu C X 2003 Guidance document on delivery, treatment planning, and clinical implementation of IMRT: report of the IMRT Subcommittee of the AAPM Radiation Therapy Committee Med. Phys. 30 2089-115 (Pubitemid 37022015)
    • (2003) Medical Physics , vol.30 , Issue.8 , pp. 2089-2115
    • Ezzell, G.A.1    Galvin, J.M.2    Low, D.3    Palta, J.R.4    Rosen, I.5    Sharpe, M.B.6    Xia, P.7    Xiao, Y.8    Xing, L.9    Yu, C.X.10
  • 8
    • 34247170048 scopus 로고    scopus 로고
    • Dosimetric evaluation of a 2D pixel ionization chamber for implementation in clinical routine
    • DOI 10.1088/0031-9155/52/4/023, PII S0031915507323877, 023
    • Herzen J, Todorovic M, Cremers F, Platz V, Albers D, Bartels A and Schmidt R 2007 Dosimetric evaluation of a 2D pixel ionization chamber for implementation in clinical routine Phys. Med. Biol. 52 1197-208 (Pubitemid 46646427)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.4 , pp. 1197-1208
    • Herzen, J.1    Todorovic, M.2    Cremers, F.3    Platz, V.4    Albers, D.5    Bartels, A.6    Schmidt, R.7
  • 9
    • 0031762329 scopus 로고    scopus 로고
    • Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy
    • DOI 10.1118/1.598381
    • Losasso T, Chui C S and Ling C C 1998 Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy Med. Phys. 25 1919-27 (Pubitemid 28485214)
    • (1998) Medical Physics , vol.25 , Issue.10 , pp. 1919-1927
    • LoSasso, T.1    Chui, C.-S.2    Ling, C.C.3
  • 11
    • 0031861573 scopus 로고    scopus 로고
    • A technique for the quantitative evaluation of dose distributions
    • DOI 10.1118/1.598248
    • Low D A, Harms W B, Mutic S and Purdy J A 1998 A technique for the quantitative evaluation of dose distributions Med. Phys. 25 656-61 (Pubitemid 28234885)
    • (1998) Medical Physics , vol.25 , Issue.5 , pp. 656-661
    • Low, D.A.1    Harms, W.B.2    Mutic, S.3    Purdy, J.A.4
  • 12
    • 46149099592 scopus 로고    scopus 로고
    • Radiochromic film dosimetry with flatbed scanners: A fast and accurate method for dose calibration and uniformity correction with single film exposure
    • DOI 10.1118/1.2936334
    • Menegotti L, Delana A and Martignano A 2008 Radiochromic film dosimetry with flatbed scanners: a fast and accurate method for dose calibration and uniformity correction with single film exposure Med. Phys. 35 3078-85 (Pubitemid 351904511)
    • (2008) Medical Physics , vol.35 , Issue.7 , pp. 3078-3085
    • Menegotti, L.1    Delana, A.2    Martignano, A.3
  • 14
    • 34248226518 scopus 로고    scopus 로고
    • Spatial resolution of 2D ionization chamber arrays for IMRT dose verification: Single-detector size and sampling step width
    • Poppe B, Djouguela A, Blechschmidt A, Willborn K, Ruhmann A and Harder D 2007 Spatial resolution of 2D ionization chamber arrays for IMRT dose verification: single-detector size and sampling step width Phys. Med. Biol. 52 2921-35
    • (2007) Phys. Med. Biol. , vol.52 , pp. 2921-2935
    • Poppe, B.1    Djouguela, A.2    Blechschmidt, A.3    Willborn, K.4    Ruhmann, A.5    Harder, D.6
  • 15
    • 0345256650 scopus 로고    scopus 로고
    • A dose delivery verification method for conventional and intensity-modulated radiation therapy using measured field fluence distributions
    • DOI 10.1118/1.1610771
    • Renner W D, Sarfaraz M, Earl M A and Yu C X 2003 A dose delivery verification method for conventional and intensity-modulated radiation therapy using measured field fluence distributions Med. Phys. 30 2996-3005 (Pubitemid 37444310)
    • (2003) Medical Physics , vol.30 , Issue.11 , pp. 2996-3005
    • Renner, W.D.1    Sarfaraz, M.2    Earl, M.A.3    Yu, C.X.4
  • 17
    • 38849173037 scopus 로고    scopus 로고
    • Accurate dosimetry with GafChromic™ EBT film of a 6 MV photon beam in water: What level is achievable?
    • DOI 10.1118/1.2828196
    • van Battum L J, Hoffmans D, Piersma H and Heukelom S 2008 Accurate dosimetry with GafChromic EBT film of a 6 MV photon beam in water: What level is achievable? Med. Phys. 35 704-16 (Pubitemid 351190890)
    • (2008) Medical Physics , vol.35 , Issue.2 , pp. 704-716
    • Van Battum, L.J.1    Hoffmans, D.2    Piersma, H.3    Heukelom, S.4
  • 18
    • 38149131763 scopus 로고    scopus 로고
    • The next step in patient-specific QA: 3D dose verification of conformal and intensity-modulated RT based on EPID dosimetry and Monte Carlo dose calculations
    • van Elmpt W, Nijsten S, Mijnheer B, Dekker A and Lambin P 2008 The next step in patient-specific QA: 3D dose verification of conformal and intensity-modulated RT based on EPID dosimetry and Monte Carlo dose calculations Radiother. Oncol. 86 86-92
    • (2008) Radiother. Oncol. , vol.86 , pp. 86-92
    • Van Elmpt, W.1    Nijsten, S.2    Mijnheer, B.3    Dekker, A.4    Lambin, P.5
  • 19
    • 77955715285 scopus 로고    scopus 로고
    • Evaluation of the 'dose of the day' for IMRT prostate cancer patients derived from portal dose measurements and cone-beam CT
    • van Zijtveld M, Dirkx M, Breuers M, Kuipers R and Heijmen B 2010 Evaluation of the 'dose of the day' for IMRT prostate cancer patients derived from portal dose measurements and cone-beam CT Radiother. Oncol. 96 172-7
    • (2010) Radiother. Oncol. , vol.96 , pp. 172-177
    • Van Zijtveld, M.1    Dirkx, M.2    Breuers, M.3    Kuipers, R.4    Heijmen, B.5
  • 21
    • 0031045089 scopus 로고    scopus 로고
    • Quantitative evaluation of radiochromic film response for two- dimensional dosimetry
    • DOI 10.1118/1.598068
    • Zhu Y, Kirov A S, Mishra V, Meigooni A S and Williamson J F 1997 Quantitative evaluation of radiochromic film response for two-dimensional dosimetry Med. Phys. 24 223-31 (Pubitemid 27084028)
    • (1997) Medical Physics , vol.24 , Issue.2 , pp. 223-231
    • Zhu, Y.1    Kirov, A.S.2    Mishra, V.3    Meigooni, A.S.4    Williamson, J.F.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.