메뉴 건너뛰기




Volumn 52, Issue 10, 2007, Pages

Spatial resolution of 2D ionization chamber arrays for IMRT dose verification: Single-detector size and sampling step width

Author keywords

[No Author keywords available]

Indexed keywords

CONVOLUTION; DETECTORS; DIODES; DOSIMETRY; OPTICAL RESOLVING POWER; PATTERN RECOGNITION;

EID: 34248226518     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/52/10/019     Document Type: Article
Times cited : (84)

References (17)
  • 1
    • 10744227747 scopus 로고    scopus 로고
    • Dosimetric characterization of a large-area pixel-segmented ionization chamber
    • Amerio S et al 2004 Dosimetric characterization of a large-area pixel-segmented ionization chamber Med. Phys. 31 414-20
    • (2004) Med. Phys. , vol.31 , Issue.2 , pp. 414-420
    • Amerio, S.1    Al, E.2
  • 2
    • 0033711209 scopus 로고    scopus 로고
    • What is the optimum leaf width of a multileaf collimator?
    • Bortfeld T, Oelfke U and Nill S 2000 What is the optimum leaf width of a multileaf collimator? Med. Phys. 27 2494-502
    • (2000) Med. Phys. , vol.27 , Issue.11 , pp. 2494-2502
    • Bortfeld, T.1    Oelfke, U.2    Nill, S.3
  • 3
    • 14644406160 scopus 로고    scopus 로고
    • A Fourier analysis of the dose grid resolution required for accurate IMRT fluence map optimization
    • Dempsey J F, Romeijn H E, Li J G and Palta J R 2005 A Fourier analysis of the dose grid resolution required for accurate IMRT fluence map optimization Med. Phys. 32 380-8
    • (2005) Med. Phys. , vol.32 , Issue.2 , pp. 380-388
    • Dempsey, J.F.1    Romeijn, H.E.2    Li, J.G.3    Palta, J.R.4
  • 5
    • 0037910445 scopus 로고    scopus 로고
    • A 2-D diode array and analysis software for verification of intensity modulated radiation therapy delivery
    • Jursinic P A and Nelms B E 2003 A 2-D diode array and analysis software for verification of intensity modulated radiation therapy delivery Med. Phys. 30 870-9
    • (2003) Med. Phys. , vol.30 , Issue.5 , pp. 870-879
    • Jursinic, P.A.1    Nelms, B.E.2
  • 6
    • 34248193518 scopus 로고    scopus 로고
    • Development of a personal computer based record and verify system (in German)
    • Kaminski H and Rubach A 1996 Development of a personal computer based record and verify system (in German) Medizinische Physik 1996 (Graz) ed H Leitner and G Stuecklschweiger pp 155-66 ISBN 3-925218-61-0
    • (1996) Medizinische Physik 1996 , pp. 155-166
    • Kaminski, H.1    Rubach, A.2    Leitner, H.3    Stuecklschweiger, G.4
  • 7
    • 0031861573 scopus 로고    scopus 로고
    • A technique for the quantitative evaluation of dose distributions
    • Low D, Harms W B, Mutic S and Purdy J 1998 A technique for the quantitative evaluation of dose distributions Med. Phys. 25 656-61
    • (1998) Med. Phys. , vol.25 , Issue.5 , pp. 656-661
    • Low, D.1    Harms, W.B.2    Mutic, S.3    Purdy, J.4
  • 8
    • 79957590676 scopus 로고
    • Certain topics in telegraph transmission theory
    • Nyquist H 1928 Certain topics in telegraph transmission theory Trans. Am. Inst. Electr. Eng. 47 617-44
    • (1928) Trans. Am. Inst. Electr. Eng. , vol.47 , pp. 617-644
    • Nyquist, H.1
  • 11
    • 34248162640 scopus 로고    scopus 로고
    • Resolution limit of the IMRT plan verification using 2D detector arrays (in German)
    • Poppe B, Djouguela A, Harder D, Rühmann A and Willborn K 2006b Resolution limit of the IMRT plan verification using 2D detector arrays (in German) Medizinische Physik 2006 (Regensburg) ed L Bogner pp 192-3
    • (2006) Medizinische Physik 2006 , pp. 192-193
  • 12
    • 0038113301 scopus 로고    scopus 로고
    • Two dimensional ionisation chamber arrays for quality assurance in radiation therapy (in German)
    • Poppe B, Mehran P, Kollhoff R and Rubach A 2003 Two dimensional ionisation chamber arrays for quality assurance in radiation therapy (in German) Z. Med. Phys. 13 115-22
    • (2003) Z. Med. Phys. , vol.13 , Issue.2 , pp. 115-122
    • Poppe, B.1    Mehran, P.2    Kollhoff, R.3    Rubach, A.4
  • 13
    • 34248200148 scopus 로고    scopus 로고
    • A method to increase the resolution of IMRT plan verification with a two-dimensional ionisation chamber array
    • Poppe B, Rubach A, Harder D and Willborn K 2006c A method to increase the resolution of IMRT plan verification with a two-dimensional ionisation chamber array Med. Phys. 33 2054
    • (2006) Med. Phys. , vol.33 , Issue.6 , pp. 2054
    • Poppe, B.1    Rubach, A.2    Harder, D.3    Willborn, K.4
  • 14
    • 84856043672 scopus 로고
    • A mathematical theory of communication.
    • Shannon C E 1948 A mathematical theory of communication. Bell Syst. Technol. J. 27 379-423, 623-56
    • (1948) Bell Syst. Technol. J. , vol.27 , pp. 379-423
    • Shannon, C.E.1
  • 16
    • 22244450090 scopus 로고    scopus 로고
    • Characterization of a 2D ion chamber array for the verification of radiotherapy treatments
    • Spezi E, Angelini A, Romani F and Ferri A 2005 Characterization of a 2D ion chamber array for the verification of radiotherapy treatments Phys. Med. Biol. 50 3361-73
    • (2005) Phys. Med. Biol. , vol.50 , Issue.14 , pp. 3361-3373
    • Spezi, E.1    Angelini, A.2    Romani, F.3    Ferri, A.4
  • 17
    • 21844443109 scopus 로고    scopus 로고
    • Dosimetric quality assurance for intensity modulated radiotherapy. Feasibility study for a filmless approach
    • Wiezorek T, Banz N, Schwedas M, Scheithauer M, Salz H, Georg D and Wendt T G 2005 Dosimetric quality assurance for intensity modulated radiotherapy. Feasibility study for a filmless approach Strahlenther. Onkol. 181 468-74
    • (2005) Strahlenther. Onkol. , vol.181 , pp. 468-474
    • Wiezorek, T.1    Banz, N.2    Schwedas, M.3    Scheithauer, M.4    Salz, H.5    Georg, D.6    Wendt, T.G.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.