메뉴 건너뛰기




Volumn 56, Issue 16, 2011, Pages 5119-5129

Fast dose calculation in magnetic fields with GPUMCD

Author keywords

[No Author keywords available]

Indexed keywords

AIR CAVITY; ANALYTICAL SOLUTIONS; CALCULATION SPEED; DEPTH DOSE; DOSE CALCULATION; DOSE DISTRIBUTIONS; DOSE EFFECTS; EXECUTION TIME; EXPERIMENTAL MEASUREMENTS; GAMMA ANALYSIS; GRAPHICS PROCESSING UNIT; MONTE CARLO DOSE CALCULATION; MONTE CARLO SIMULATION; PENCIL BEAM; PLANNING STAGES; PROOF OF CONCEPT; RE-PLANNING; STATISTICAL UNCERTAINTY; STRONG MAGNETIC FIELDS;

EID: 79961069898     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/56/16/003     Document Type: Article
Times cited : (99)

References (17)
  • 3
    • 33645004926 scopus 로고    scopus 로고
    • Magnetic confinement of electron and photon radiotherapy dose: A Monte Carlo simulation with a nonuniform longitudinal magnetic field
    • Chen Yu, Bielajew A F, Litzenberg D W, Moran J M and Becchetti F D 2005 Magnetic confinement of electron and photon radiotherapy dose: a Monte Carlo simulation with a nonuniform longitudinal magnetic field Med. Phys. 32 3810-8
    • (2005) Med. Phys. , vol.32 , Issue.12 , pp. 3810-3818
    • Yu, C.1    Bielajew, A.F.2    Litzenberg, D.W.3    Moran, J.M.4    Becchetti, F.D.5
  • 5
    • 79551666078 scopus 로고    scopus 로고
    • GPUMCD: A new GPU-oriented Monte Carlo dose calculation platform
    • Hissoiny S, Ozell B, Bouchard H and Després P 2011 GPUMCD: a new GPU-oriented Monte Carlo dose calculation platform Med. Phys. 38 754-64
    • (2011) Med. Phys. , vol.38 , Issue.2 , pp. 754-764
    • Hissoiny S, O.1
  • 7
    • 0034071304 scopus 로고    scopus 로고
    • The effect of dose calculation uncertainty on the evaluation of radiotherapy plans
    • DOI 10.1118/1.598916
    • Keall P J, Siebers J V, Jeraj R and Mohan R 2000 The effect of dose calculation uncertainty on the evaluation of radiotherapy plans Med. Phys. 27 478-84 (Pubitemid 30171796)
    • (2000) Medical Physics , vol.27 , Issue.3 , pp. 478-484
    • Keall, P.J.1    Siebers, J.V.2    Jeraj, R.3    Mohan, R.4
  • 11
    • 0031861573 scopus 로고    scopus 로고
    • A technique for the quantitative evaluation of dose distributions
    • DOI 10.1118/1.598248
    • Low D A, Harms W B, Mutic S and Purdy J A 1998 A technique for the quantitative evaluation of dose distributions Med. Phys. 25 656-61 (Pubitemid 28234885)
    • (1998) Medical Physics , vol.25 , Issue.5 , pp. 656-661
    • Low, D.A.1    Harms, W.B.2    Mutic, S.3    Purdy, J.A.4
  • 13
    • 17144414177 scopus 로고    scopus 로고
    • Integrating a MRI scanner with a 6 MV radiotherapy accelerator: Dose increase at tissue-air interfaces in a lateral magnetic field due to returning electrons
    • Raaijmakers A J E, Raaymakers B W and Lagendijk J J W 2005 Integrating a MRI scanner with a 6 MV radiotherapy accelerator: dose increase at tissue-air interfaces in a lateral magnetic field due to returning electrons Phys. Med. Biol. 50 1363
    • (2005) Phys. Med. Biol. , vol.50 , Issue.7 , pp. 1363
    • Raaijmakers, A.J.E.1    Raaymakers, B.W.2    Lagendijk, J.J.W.3
  • 14
    • 34547286368 scopus 로고    scopus 로고
    • Experimental verification of magnetic field dose effects for the MRI-accelerator
    • Raaijmakers A J E, Raaymakers B W and Lagendijk J J W 2007 Experimental verification of magnetic field dose effects for the MRI-accelerator Phys. Med. Biol. 52 4283
    • (2007) Phys. Med. Biol. , vol.52 , Issue.14 , pp. 4283
    • Raaijmakers, A.J.E.1    Raaymakers, B.W.2    Lagendijk, J.J.W.3
  • 15
    • 39049162750 scopus 로고    scopus 로고
    • Magnetic-field-induced dose effects in MR-guided radiotherapy systems: Dependence on the magnetic field strength
    • Raaijmakers A J E, Raaymakers B W and Lagendijk J J W 2008 Magnetic-field-induced dose effects in MR-guided radiotherapy systems: dependence on the magnetic field strength Phys. Med. Biol. 53 909
    • (2008) Phys. Med. Biol. , vol.53 , Issue.4 , pp. 909
    • Raaijmakers, A.J.E.1    Raaymakers, B.W.2    Lagendijk, J.J.W.3
  • 16
    • 70149091087 scopus 로고    scopus 로고
    • Integrating a 1.5 T MRI scanner with a 6 MV accelerator: Proof of concept
    • Raaymakers B W, et al. 2009 Integrating a 1.5 T MRI scanner with a 6 MV accelerator: proof of concept Phys. Med. Biol. 54 N229
    • (2009) Phys. Med. Biol. , vol.54 , Issue.12 , pp. 229
    • Raaymakers, B.W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.