Volumn 52, Issue 14, 2007, Pages 4283-4291

Experimental verification of magnetic field dose effects for the MRI-accelerator

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER SIMULATION; LORENTZ FORCE; MAGNETIC FIELD EFFECTS; MAGNETIC RESONANCE IMAGING; MONTE CARLO METHODS; PATIENT TREATMENT; TISSUE ENGINEERING;

EID: 34547286368     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/52/14/017     Document Type: Article
Times cited : (96)

References (13)
  • 2
    • 0027182723 scopus 로고
    • The effect of strong longitudinal magnetic fields on dose deposition from electron and photon beams
    • Bielajew A F 1993 The effect of strong longitudinal magnetic fields on dose deposition from electron and photon beams Med. Phys. 20 1171-9
    • (1993) Med. Phys. , vol.20 , Issue.4 , pp. 1171-1179
    • Bielajew, A.F.1
  • 4
    • 0033857490 scopus 로고    scopus 로고
    • Magnetic fields with photon beams: Dose calculation using electron multiple-scattering theory
    • Jette D 2000 Magnetic fields with photon beams: dose calculation using electron multiple-scattering theory Med. Phys. 27 1705-16
    • (2000) Med. Phys. , vol.27 , Issue.8 , pp. 1705-1716
    • Jette, D.1
  • 5
    • 0035116471 scopus 로고    scopus 로고
    • Conformal photon-beam therapy with transverse magnetic fields: Monte Carlo study
    • Li X A, Reiffel L, Chu J and Naqvi S 2001 Conformal photon-beam therapy with transverse magnetic fields: Monte Carlo study Med. Phys. 28 127-33
    • (2001) Med. Phys. , vol.28 , Issue.2 , pp. 127-133
    • Li, X.A.1    Reiffel, L.2    Chu, J.3    Naqvi, S.4
  • 6
    • 0031861573 scopus 로고    scopus 로고
    • A technique for the quantitative evaluation of dose distributions
    • Low D A, Harms W B, Mutic S and Purdy J A 1998 A technique for the quantitative evaluation of dose distributions Med. Phys. 25 656-61
    • (1998) Med. Phys. , vol.25 , Issue.5 , pp. 656-661
    • Low, D.A.1    Harms, W.B.2    Mutic, S.3    Purdy, J.A.4
  • 7
    • 14644444543 scopus 로고    scopus 로고
    • Consistency test of the electron transport algorithm in the GEANT4 Monte Carlo code
    • Poon E, Seuntjens J and Verhaegen F 2005 Consistency test of the electron transport algorithm in the GEANT4 Monte Carlo code Phys. Med. Biol. 50 681-94
    • (2005) Phys. Med. Biol. , vol.50 , Issue.4 , pp. 681-694
    • Poon, E.1    Seuntjens, J.2    Verhaegen, F.3
  • 8
    • 14644405544 scopus 로고    scopus 로고
    • Accuracy of the photon and electron physics in geant4 for radiotherapy applications
    • Poon E and Verhaegen F 2005 Accuracy of the photon and electron physics in geant4 for radiotherapy applications Med. Phys. 32 1696-711
    • (2005) Med. Phys. , vol.32 , Issue.6 , pp. 1696-1711
    • Poon, E.1    Verhaegen, F.2
  • 9
    • 17144414177 scopus 로고    scopus 로고
    • Integrating a MRI scanner with a 6 MV radiotherapy accelerator: Dose increase at tissue-air interfaces in a lateral magnetic field due to returning electrons
    • Raaijmakers A J E, Raaymakers B W and Lagendijk J J W 2005 Integrating a MRI scanner with a 6 MV radiotherapy accelerator: dose increase at tissue-air interfaces in a lateral magnetic field due to returning electrons Phys. Med. Biol. 50 1363-76
    • (2005) Phys. Med. Biol. , vol.50 , Issue.7 , pp. 1363-1376
    • Raaijmakers, A.J.E.1    Raaymakers, B.W.2    Lagendijk, J.J.W.3
  • 10
    • 34247132282 scopus 로고    scopus 로고
    • Integrating a MRI scanner with a 6 MV radiotherapy accelerator: Impact of the surface orientation on the entrance and exit dose due to the transverse magnetic field
    • Raaijmakers A J E, Raaymakers B W, van der Meer S and Lagendijk J J W 2007 Integrating a MRI scanner with a 6 MV radiotherapy accelerator: impact of the surface orientation on the entrance and exit dose due to the transverse magnetic field Phys. Med. Biol. 52 929-39
    • (2007) Phys. Med. Biol. , vol.52 , Issue.4 , pp. 929-939
    • Raaijmakers, A.J.E.1    Raaymakers, B.W.2    Van Der Meer, S.3    Lagendijk, J.J.W.4
  • 12
    • 4544360914 scopus 로고    scopus 로고
    • Integrating a MRI scanner with a 6 MV radiotherapy accelerator: Dose deposition in a transverse magnetic field
    • Raaymakers B W, Raaijmakers A J E, Kotte A N T J, Jette D and Lagendijk J J W 2004b Integrating a MRI scanner with a 6 MV radiotherapy accelerator: dose deposition in a transverse magnetic field Phys. Med. Biol. 49 4109-18
    • (2004) Phys. Med. Biol. , vol.49 , Issue.17 , pp. 4109-4118
    • Raaymakers, B.W.1    Raaijmakers, A.J.E.2    Kotte, A.N.T.J.3    Jette, D.4    Lagendijk, J.J.W.5