메뉴 건너뛰기




Volumn 17, Issue 1 PART 1, 2008, Pages

In silico testing and in vivo experiments with closed-loop control of blood glucose in diabetes

Author keywords

Biomedical system modeling, simulation and visualization; Healthcare management, disease control, critical care; Quantification of physiological parameters for diagnosis and treatment assessment

Indexed keywords

BIOMEDICAL SYSTEM MODELING, SIMULATION AND VISUALIZATION; BLOOD GLUCOSE; CLINICAL STUDY; CLINICAL TRIAL; CLOSED-LOOP CONTROL; CONTINUOUS GLUCOSE MONITORING; CONTROL ALGORITHMS; DIABETES CARE; HEALTHCARE MANAGEMENT, DISEASE CONTROL, CRITICAL CARE; IN-SILICO; IN-VIVO; IN-VIVO EXPERIMENTS; INSULIN DELIVERY; INSULIN PUMPS; MATHEMATICAL MODELING; METABOLIC SYSTEMS; POSITIVE EFFECTS; QUANTIFICATION OF PHYSIOLOGICAL PARAMETERS FOR DIAGNOSIS AND TREATMENT ASSESSMENT;

EID: 79961019786     PISSN: 14746670     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.3182/20080706-5-KR-1001.2448     Document Type: Conference Paper
Times cited : (4)

References (46)
  • 1
    • 0016259390 scopus 로고
    • The articial beta cell - A continuous control of blood sugar by external regulation of insulin infusion (glucose controlled insulin infusion system)
    • E. F. Pfeiffer, C. H. Thum, and A. H. Clemens. The articial beta cell - A continuous control of blood sugar by external regulation of insulin infusion (glucose controlled insulin infusion system). Horm Metab Res, 487:339-442, 1974.
    • (1974) Horm Metab Res , vol.487 , pp. 339-442
    • Pfeiffer, E.F.1    Thum, C.H.2    Clemens, A.H.3
  • 3
    • 0017338283 scopus 로고
    • The development of Biostator, a glucose-controlled insulin infusion system
    • A. H. Clemens, P. H. Chang, and R. W. Myers. The development of Biostator, a glucose-controlled insulin infusion system. Horm Metab Res Supplement, 7:23-33, 1977.
    • (1977) Horm Metab Res Supplement , vol.7 , pp. 23-33
    • Clemens, A.H.1    Chang, P.H.2    Myers, R.W.3
  • 4
  • 5
    • 0018344878 scopus 로고
    • Closed-loop and open-loop devices for blood glucose control in normal and diabetic subjects
    • J. V. Santiago, A. H. Clemens, W. L. Clarke, and D. M. Kipnis. Closed-loop and open-loop devices for blood glucose control in normal and diabetic subjects. Diabetes, 28:71-84, 1979. (Pubitemid 9103179)
    • (1979) Diabetes , vol.28 , Issue.1 , pp. 71-84
    • Santiago, J.V.1    Clemens, A.H.2    Clarke, W.L.3    Kipnis, D.M.4
  • 7
    • 0018192338 scopus 로고
    • Derivation and experimental proof of a new algorithm for the articial beta-cell based on the individual analysis of the physiological insulin- Glucose relationship
    • U. Fischer, E. Jutzi, E-J. Freyse, and E. Salzsieder. Derivation and experimental proof of a new algorithm for the articial beta-cell based on the individual analysis of the physiological insulin- glucose relationship. Endokrinologie, 71:65-75, 1978.
    • (1978) Endokrinologie , vol.71 , pp. 65-75
    • Fischer, U.1    Jutzi, E.2    Freyse, E.-J.3    Salzsieder, E.4
  • 8
    • 0018759042 scopus 로고
    • Feedback control dynamics for glucose controlled insulin infusion system
    • A. H. Clemens. Feedback control dynamics for glucose controlled insulin infusion system. MedProg Technol., 6: 91-98, 1979. (Pubitemid 9213094)
    • (1979) Medical Progress Through Technology , vol.6 , Issue.3 , pp. 91-98
    • Clemens, A.H.1
  • 9
    • 0019728673 scopus 로고
    • Comparison of algorithms for the closed-loop control of blood glucose using the articial beta cell
    • H. M. Broekhuyse, J. D. Nelson, B. Zinman, and A. M. Albisser. Comparison of algorithms for the closed-loop control of blood glucose using the articial beta cell. IEEE Trans Biomed Eng, BME-28:678-687, 1981.
    • (1981) IEEE Trans Biomed Eng , vol.BME-28 , pp. 678-687
    • Broekhuyse, H.M.1    Nelson, J.D.2    Zinman, B.3    Albisser, A.M.4
  • 10
    • 0022270359 scopus 로고
    • Kinetic modeling of the gluco-regulatory system to improve insulin therapy
    • E. Salzsieder, G. Albrecht, U. Fischer, and E-J Freyse. Kinetic modeling of the gluco-regulatory system to improve insulin therapy. IEEE Trans Biomed Eng, 32: 846-855, 1985.
    • (1985) IEEE Trans Biomed Eng , vol.32 , pp. 846-855
    • Salzsieder, E.1    Albrecht, G.2    Fischer, U.3    Freyse, E.-J.4
  • 13
    • 0024883144 scopus 로고
    • Application of optimal control theory to diabetes mellitus
    • R. L. Ollerton. Application of optimal control theory to diabetes mellitus. Int J Control, 50:2503-2522, 1989. (Pubitemid 20647118)
    • (1989) International Journal of Control , vol.50 , Issue.6 , pp. 2503-2522
    • Ollerton, R.L.1
  • 14
    • 0025980709 scopus 로고
    • A semi closed-loop algorithm for the control of blood glucose levels in diabetics
    • M. E. Fischer. A semi closed-loop algorithm for the control of blood glucose levels in diabetics. IEEE Trans Biomed Eng, 38:57-61, 1991.
    • (1991) IEEE Trans Biomed Eng , vol.38 , pp. 57-61
    • Fischer, M.E.1
  • 15
    • 0022479904 scopus 로고
    • Glycemic control with closed-loop intraperitoneal insulin in type I diabetes
    • H. Leblanc, D. Chauvet, P. Lombrail, and J. J. Robert. Glycemic control with closed-loop intraperitoneal insulin in type I diabetes. Diabetes Care, 9:124-128, 1986. (Pubitemid 16080465)
    • (1986) Diabetes Care , vol.9 , Issue.2 , pp. 124-128
    • Leblanc, H.1    Chauvet, D.2    Lombrail, P.3    Robert, J.J.4
  • 16
    • 0026659759 scopus 로고
    • Clinical trial of programmable implantable insulin pump for type I diabetes
    • J. L. Selam, P. Micossi, F. L. Dunn, and D. M. Nathan. Clinical trial of programmable implantable insulin pump for type I diabetes. Diabetes Care, 15:877-885, 1992.
    • (1992) Diabetes Care , vol.15 , pp. 877-885
    • Selam, J.L.1    Micossi, P.2    Dunn, F.L.3    Nathan, D.M.4
  • 17
    • 0036902299 scopus 로고    scopus 로고
    • Implantable closed-loop glucose-sensing and insulin delivery: The future for insulin pump therapy
    • E. Renard. Implantable closed-loop glucose-sensing and insulin delivery: the future for insulin pump therapy. Current Opinion in Pharmacology, 2:708-716, 2002.
    • (2002) Current Opinion in Pharmacology , vol.2 , pp. 708-716
    • Renard, E.1
  • 18
    • 34248162815 scopus 로고    scopus 로고
    • The Articial Pancreas: How Sweet Engineering Will Solve Bitter Problems
    • D. C. Klono. The Articial Pancreas: How Sweet Engineering Will Solve Bitter Problems. J Diabetes Sci Technol, 1:72-81, 2007.
    • (2007) J Diabetes Sci Technol , vol.1 , pp. 72-81
    • Klono, D.C.1
  • 19
    • 33845521334 scopus 로고    scopus 로고
    • Feasibility of automating insulin delivery for the treatment of type 1 diabetes
    • DOI 10.2337/db06-0419
    • G. M. Steil, K. Rebrin, C. Darwin, F. Hariri, and M. F. Saad. Feasibility of automating insulin delivery for the treatment of type 1 diabetes. Diabetes, 55:3344-3350, 2006. (Pubitemid 44923591)
    • (2006) Diabetes , vol.55 , Issue.12 , pp. 3344-3350
    • Steil, G.M.1    Rebrin, K.2    Darwin, C.3    Hariri, F.4    Saad, M.F.5
  • 20
    • 70349388344 scopus 로고    scopus 로고
    • Closed-Loop Articial Pancreas: Feasibility Studies in Pediatric Patients with Type 1 Diabetes
    • S. Weinzimer. Closed-Loop Articial Pancreas: Feasibility Studies in Pediatric Patients with Type 1 Diabetes. Proc. 6th Diabetes Technology Meeting, S55, 2006.
    • (2006) Proc. 6th Diabetes Technology Meeting , vol.S55
    • Weinzimer, S.1
  • 23
    • 0242300707 scopus 로고    scopus 로고
    • Validation of the Archimedes Diabetes Model
    • D. M. Eddy, and L. Schlessinger. Validation of the Archimedes Diabetes Model. Diabetes Care, 26:3102-3110, 2003.
    • (2003) Diabetes Care , vol.26 , pp. 3102-3110
    • Eddy, D.M.1    Schlessinger, L.2
  • 24
    • 0242300709 scopus 로고    scopus 로고
    • Archimedes: A Trial- Validate Model of Diabetes
    • D. M. Eddy, and L. Schlessinger. Archimedes: A Trial- Validate Model of Diabetes. Diabetes Care, 26:3093-3101, 2003.
    • (2003) Diabetes Care , vol.26 , pp. 3093-3101
    • Eddy, D.M.1    Schlessinger, L.2
  • 27
    • 0033051709 scopus 로고    scopus 로고
    • Performance of subcutaneously implanted glucose sensors for continuous monitoring
    • M. Gerritsen, J. A. Jansen, and J. A. Lutterman. Performance of subcutaneously implanted glucose sensors for continuous monitoring. Neth J Med, 54:167-179, 1999.
    • (1999) Neth J Med , vol.54 , pp. 167-179
    • Gerritsen, M.1    Jansen, J.A.2    Lutterman, J.A.3
  • 29
    • 0036410402 scopus 로고    scopus 로고
    • Performance of a continuous glucose monitoring system during controlled hypoglycaemia in healthy volunteers
    • DOI 10.1089/152091502320798222
    • E. H. Cheyne, D. A. Cavan, and D. Kerr. Performance of continuous glucose monitoring system during controlled hypoglycemia in healthy volunteers. Diabetes Technol Ther, 4:607-613, 2002. (Pubitemid 35283323)
    • (2002) Diabetes Technology and Therapeutics , vol.4 , Issue.5 , pp. 607-613
    • Cheyne, E.H.1    Cavan, D.A.2    Kerr, D.3
  • 30
    • 3342981187 scopus 로고    scopus 로고
    • Evaluating the accuracy of continuous glucose monitoring sensors: Continuous Glucose Error-Grid Analysis (CG-EGA) illustrated by Therasense Freestyle Navigator data
    • B. P. Kovatchev, L. A. GonderFrederick, D. J. Cox, and W. L. Clarke. Evaluating the accuracy of continuous glucose monitoring sensors: Continuous Glucose Error-Grid Analysis (CG-EGA) illustrated by Therasense Freestyle Navigator data. Diabetes Care, 27:1922-1928, 2004.
    • (2004) Diabetes Care , vol.27 , pp. 1922-1928
    • Kovatchev, B.P.1    GonderFrederick, L.A.2    Cox, D.J.3    Clarke, W.L.4
  • 32
    • 59649095660 scopus 로고    scopus 로고
    • Continuous glucose sensors - Continuing questions about clinical accuracy
    • W. L. Clarke, and B. P. Kovatchev, Continuous glucose sensors - continuing questions about clinical accuracy. J Diabetes Sci Technol, 1:164-170, 2005.
    • (2005) J Diabetes Sci Technol , vol.1 , pp. 164-170
    • Clarke, W.L.1    Kovatchev, B.P.2
  • 34
    • 59649089217 scopus 로고    scopus 로고
    • Modeling of Calibration Eectiveness and Blood-to-Interstitial Glucose Dynamics as Potential Confounders of the Accuracy of Continuous Glucose Sensors
    • C. R. King, S. M. Anderson, M. D. Breton, W. L. Clarke, and B. P. Kovatchev. Modeling of Calibration Eectiveness and Blood-to-Interstitial Glucose Dynamics as Potential Confounders of the Accuracy of Continuous Glucose Sensors. J Diabetes Sci Technol, 1:317-322, 2007.
    • (2007) J Diabetes Sci Technol , vol.1 , pp. 317-322
    • King, C.R.1    Anderson, S.M.2    Breton, M.D.3    Clarke, W.L.4    Kovatchev, B.P.5
  • 35
    • 0034032108 scopus 로고    scopus 로고
    • Models of subcutaneous insulin kinetics. A critical review
    • G. Nucci, and C. Cobelli. Models of subcutaneous insulin kinetics. A critical review. Comput Methods Programs Biomed., 62:249-257, 2000.
    • (2000) Comput Methods Programs Biomed. , vol.62 , pp. 249-257
    • Nucci, G.1    Cobelli, C.2
  • 37
    • 18144421498 scopus 로고    scopus 로고
    • Continuous glucose monitoring: Roadmap for 21st century diabetes therapy
    • D. C. Klono. Continuous glucose monitoring: Roadmap for 21st century diabetes therapy. Diabetes Care, 28: 1231-1239, 2005.
    • (2005) Diabetes Care , vol.28 , pp. 1231-1239
    • Klono, D.C.1
  • 38
    • 33644875792 scopus 로고    scopus 로고
    • Improvement in Glycemic Excursions with a Transcutaneous, Real-time Continuous Glucose Sensor
    • K. Garg, H. Zisser, S. Schwartz, T. Bailey, R. Kaplan, S. Ellis, L. Jovanovic. Improvement in Glycemic Excursions With a Transcutaneous, Real-time Continuous Glucose Sensor. Diabetes Care, 29:44-50, 2006.
    • (2006) Diabetes Care , vol.29 , pp. 44-50
    • Garg, K.1    Zisser, H.2    Schwartz, S.3    Bailey, T.4    Kaplan, R.5    Ellis, S.6    Jovanovic, L.7
  • 39
    • 33845483509 scopus 로고    scopus 로고
    • Improved Glycemic Control in Poorly Controlled Patients with Type 1 Diabetes Using Real-Time Continuous Glucose Monitoring
    • D. Deiss, J. Bolinder, J. Riveline, T. Battellino, E. Bosi, N. Tubiana-Ru, D. Kerr, M. Phillip Improved Glycemic Control in Poorly Controlled Patients with Type 1 Diabetes Using Real-Time Continuous Glucose Monitoring. Diabetes Care, 29:2730-2732, 2006.
    • (2006) Diabetes Care , vol.29 , pp. 2730-2732
    • Deiss, D.1    Bolinder, J.2    Riveline, J.3    Battellino, T.4    Bosi, E.5    Tubiana-Ru, N.6    Kerr, D.7    Phillip, M.8
  • 40
    • 44849122819 scopus 로고    scopus 로고
    • Continuous Glucose Monitoring (CGM) reduces risks for hypo- And hyperglycemia and glucose variability in T1DM and insulintreated T2DM
    • B. P. Kovatchev, W. L. Clarke. Continuous Glucose Monitoring (CGM)) reduces risks for hypo- and hyperglycemia and glucose variability in T1DM and insulintreated T2DM. Diabetes, 56(Suppl 1):A23, 2007.
    • (2007) Diabetes , vol.56 , Issue.SUPPL. 1
    • Kovatchev, B.P.1    Clarke, W.L.2
  • 41
    • 44849122819 scopus 로고    scopus 로고
    • Continuous Glucose Monitoring (CGM) Reduces Risks for Hypo- And Hyperglycemia and Glucose Variability in Diabetes
    • B. P. Kovatchev, W. L. Clarke. Continuous Glucose Monitoring (CGM) Reduces Risks for Hypo- and Hyperglycemia and Glucose Variability in Diabetes. Diabetes, 56(Suppl 1):0086OR, 2007.
    • (2007) Diabetes , vol.56 , Issue.SUPPL. 1
    • Kovatchev, B.P.1    Clarke, W.L.2
  • 42
    • 31144461926 scopus 로고    scopus 로고
    • Quantifying Temporal Glucose Variability in Diabetes via Continuous Glucose Monitoring: Mathematical Methods and Clinical Application
    • B. P. Kovatchev, W. L. Clarke, M. Breton, K. Brayman, A. McCall. Quantifying Temporal Glucose Variability in Diabetes via Continuous Glucose Monitoring: Mathematical Methods and Clinical Application. Diabetes Technology and Therapeutics, 7:849-862, 2005.
    • (2005) Diabetes Technology and Therapeutics , vol.7 , pp. 849-862
    • Kovatchev, B.P.1    Clarke, W.L.2    Breton, M.3    Brayman, K.4    McCall, A.5
  • 43
    • 33845342900 scopus 로고    scopus 로고
    • A Novel Analytical Method for Assessing Glucose Variability: Using CGMS in Type 1 Diabetes Mellitus
    • A. McCall, D. J. Cox, J. Crean, M. Gloster, and B. P. Kovatchev. A Novel Analytical Method for Assessing Glucose Variability: Using CGMS in Type 1 Diabetes Mellitus. Diabetes Technology and Therapeutics, 8:644-653, 2006.
    • (2006) Diabetes Technology and Therapeutics , vol.8 , pp. 644-653
    • McCall, A.1    Cox, D.J.2    Crean, J.3    Gloster, M.4    Kovatchev, B.P.5
  • 45
    • 33645051466 scopus 로고    scopus 로고
    • Continuous glucose monitoring and closedloop systems
    • R.Hovorka. Continuous glucose monitoring and closedloop systems. Diabetic Medicine, 23:1-12, 2005.
    • (2005) Diabetic Medicine , vol.23 , pp. 1-12
    • Hovorka, R.1
  • 46
    • 84887257430 scopus 로고    scopus 로고
    • Adaptive closed-loop control provides blood-glucose regulation using dual subcutaneous insulin and glucagon infusion in diabetic swine
    • F. H. El-Khatib, J. Jiang, E. R. Damiano. Adaptive closed-loop control provides blood-glucose regulation using dual subcutaneous insulin and glucagon infusion in diabetic swine. Diabetes Sci Tech, 1:181-192, 2007.
    • (2007) Diabetes Sci Tech , vol.1 , pp. 181-192
    • El-Khatib, F.H.1    Jiang, J.2    Damiano, E.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.