메뉴 건너뛰기




Volumn 17, Issue 3, 2000, Pages 287-293

Graft revision after transit time flow measurement in off-pump coronary artery bypass grafting

Author keywords

Graft; Off coronary pulmonary bypass; Revision; Transit time flow measurement

Indexed keywords

ANASTOMOSIS; ARTERY DISSECTION; ARTICLE; COMPLICATION; CORONARY ARTERY BLOOD FLOW; CORONARY ARTERY BYPASS GRAFT; CORONARY ARTERY OBSTRUCTION; CORONARY ARTERY THROMBOSIS; FLOW MEASUREMENT; GRAFT PATENCY; HUMAN; MAJOR CLINICAL STUDY; PRIORITY JOURNAL; STENOSIS; THROMBOSIS;

EID: 0034162153     PISSN: 10107940     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1010-7940(00)00332-8     Document Type: Article
Times cited : (179)

References (12)
  • 1
    • 0028135550 scopus 로고
    • Intraoperative assessment of coronary artery bypass grafts using a pulsed doppler flowmeter
    • Louagie Y.A.G., Haxhe J.P., Jamarat J., Buch M., Schoevaerdts J.C. Intraoperative assessment of coronary artery bypass grafts using a pulsed doppler flowmeter. Ann Thorac Surg. 58:1994;742-749.
    • (1994) Ann Thorac Surg , vol.58 , pp. 742-749
    • Louagie, Y.A.G.1    Haxhe, J.P.2    Jamarat, J.3    Buch, M.4    Schoevaerdts, J.C.5
  • 2
    • 0027932275 scopus 로고
    • Ultrasonic assessment of internal thoracic artery graft flow in the revascularized heart
    • Canver C.C., Dame N. Ultrasonic assessment of internal thoracic artery graft flow in the revascularized heart. Ann Thorac Surg. 58:1994;135-138.
    • (1994) Ann Thorac Surg , vol.58 , pp. 135-138
    • Canver, C.C.1    Dame, N.2
  • 3
    • 0030836465 scopus 로고    scopus 로고
    • Clinical importance of measuring coronary graft flows in the revascularized heart. Ultrasonic or electromagnetic?
    • Canver C.C., Cooler S.D., Murray E.L., et al. Clinical importance of measuring coronary graft flows in the revascularized heart. Ultrasonic or electromagnetic? J Cardiovasc Surg. 38:1997;211-215.
    • (1997) J Cardiovasc Surg , vol.38 , pp. 211-215
    • Canver, C.C.1    Cooler, S.D.2    Murray, E.L.3
  • 4
    • 0030308204 scopus 로고    scopus 로고
    • Intraoperative internal mammary artery transit-time flow measurements: Comparative evaluation of two surgical pedicle preparation techniques
    • Walpoth B.H., Mohadjer A., Gersbach P., Rogulenko R., Walpoth B.N., Althaus U. Intraoperative internal mammary artery transit-time flow measurements: comparative evaluation of two surgical pedicle preparation techniques. Eur J Cardio-thorac Surg. 10:(12):1996;1064-1070.
    • (1996) Eur J Cardio-thorac Surg , vol.10 , Issue.12 , pp. 1064-1070
    • Walpoth, B.H.1    Mohadjer, A.2    Gersbach, P.3    Rogulenko, R.4    Walpoth, B.N.5    Althaus, U.6
  • 6
    • 0032717765 scopus 로고    scopus 로고
    • Single-suture for circumflex exposure in off-pump coronary artery bypass grafting.
    • Bergsland J., Karamanoukian H.L., Soltoski P.R., Salerno T.A. Single-suture for circumflex exposure in off-pump coronary artery bypass grafting. Ann Thorac Surg. 68:(4):1999;1428-1430.
    • (1999) Ann Thorac Surg , vol.68 , Issue.4 , pp. 1428-1430
    • Bergsland, J.1    Karamanoukian, H.L.2    Soltoski, P.R.3    Salerno, T.A.4
  • 7
    • 0032794852 scopus 로고    scopus 로고
    • Neural network pattern recognition analysis of garft flow characteristics improves intra-operative anastomotic error detection in minimally invasive CABG
    • Cerrito P.B., Koenig S.C., Koenig S.C., Van Himbergen D.J., Jaber S.F., Ewert D.L., Spence P.A. Neural network pattern recognition analysis of garft flow characteristics improves intra-operative anastomotic error detection in minimally invasive CABG. Eur J Cardio-thorac Surg. 16:1999;88-93.
    • (1999) Eur J Cardio-thorac Surg , vol.16 , pp. 88-93
    • Cerrito, P.B.1    Koenig, S.C.2    Koenig, S.C.3    Van Himbergen, D.J.4    Jaber, S.F.5    Ewert, D.L.6    Spence, P.A.7
  • 8
    • 0032212765 scopus 로고    scopus 로고
    • Can visual assessment of flow waveform morphology detedt anastomotic error in off pump coronary artery bypass grafting?
    • Jaber S.F., Koenig S.C., BhaskerRao B., Van Himbergen D.J., Spence P.A. Can visual assessment of flow waveform morphology detedt anastomotic error in off pump coronary artery bypass grafting? Eur J Cardio-thorac Surg. 14:1998;476-479.
    • (1998) Eur J Cardio-thorac Surg , vol.14 , pp. 476-479
    • Jaber, S.F.1    Koenig, S.C.2    Bhaskerrao, B.3    Van Himbergen, D.J.4    Spence, P.A.5
  • 12
    • 0344348818 scopus 로고    scopus 로고
    • Evaluation of coronary bypass flow with color-Doppler and magnetic resonance imaging techniques: Comparison with intraoperative flow measurements
    • Walpoth B.H., Muller M.F., Genyk I., Aeschbacher B., Althaus U., Carrel T.P. Evaluation of coronary bypass flow with color-Doppler and magnetic resonance imaging techniques: comparison with intraoperative flow measurements. Eur J Cardio-thorac Surg. 15:1999;795-802.
    • (1999) Eur J Cardio-thorac Surg , vol.15 , pp. 795-802
    • Walpoth, B.H.1    Muller, M.F.2    Genyk, I.3    Aeschbacher, B.4    Althaus, U.5    Carrel, T.P.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.