메뉴 건너뛰기




Volumn 51, Issue 1, 2005, Pages 26-29

Comparison of pulsatile with nonpulsatile mechanical support in a porcine model of profound cardiogenic shock

Author keywords

[No Author keywords available]

Indexed keywords

BLOOD VESSELS; CENTRIFUGAL PUMPS; HEMODYNAMICS; LIVING SYSTEMS STUDIES; PHYSIOLOGICAL MODELS; PRESSURE EFFECTS; ULTRASONIC FLOWMETERS;

EID: 19944431767     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.MAT.0000150323.62708.35     Document Type: Article
Times cited : (26)

References (29)
  • 1
    • 0002855087 scopus 로고    scopus 로고
    • Device selection
    • Goldstein DJ, Oz MC (eds), Armonk, NY: Futura Publishing
    • Sun BC: Device selection, in Goldstein DJ, Oz MC (eds), Cardiac Assist Devices. Armonk, NY: Futura Publishing, 2000, pp. 27-36.
    • (2000) Cardiac Assist Devices , pp. 27-36
    • Sun, B.C.1
  • 2
    • 0038156416 scopus 로고
    • The effect of the pulse on the spread of substances through tissues
    • McMaster PD, Parsons RJ: The effect of the pulse on the spread of substances through tissues. J Exp Med 68: 377-400, 1938.
    • (1938) J Exp Med , vol.68 , pp. 377-400
    • McMaster, P.D.1    Parsons, R.J.2
  • 3
    • 0011034337 scopus 로고
    • The physiologic importance of pulsatile blood flow
    • Wilkens H, Regelson W, Hoffmeister F: The physiologic importance of pulsatile blood flow. N Engl J Med 267: 443-446, 1962.
    • (1962) N Engl J Med , vol.267 , pp. 443-446
    • Wilkens, H.1    Regelson, W.2    Hoffmeister, F.3
  • 4
    • 0017870958 scopus 로고
    • To pulse or not to pulse
    • Mavroudis C: To pulse or not to pulse. Ann Thorac Surg 25: 259-271, 1978.
    • (1978) Ann Thorac Surg , vol.25 , pp. 259-271
    • Mavroudis, C.1
  • 5
    • 0021023824 scopus 로고
    • Pulsatile and nonpulsatile cardiopulmonary bypass: Review of a counterproductive controversy
    • Hickey PR, Buckley MJ, Philbin DM: Pulsatile and nonpulsatile cardiopulmonary bypass: Review of a counterproductive controversy. Ann Thorac Surg 36: 720-737, 1983.
    • (1983) Ann Thorac Surg , vol.36 , pp. 720-737
    • Hickey, P.R.1    Buckley, M.J.2    Philbin, D.M.3
  • 6
    • 0030959954 scopus 로고    scopus 로고
    • Pulsatile and nonpulsatile perfusion: The continuing controversy
    • Hornick P, Taylor K: Pulsatile and nonpulsatile perfusion: The continuing controversy. J Cardiothorac Vasc Anesth 11: 310-315, 1997.
    • (1997) J Cardiothorac Vasc Anesth , vol.11 , pp. 310-315
    • Hornick, P.1    Taylor, K.2
  • 7
    • 0345072096 scopus 로고    scopus 로고
    • Axial flow pumps
    • Goldstein DJ, Oz MC (eds), Armonk, NY: Futura Publishing
    • DeRose J, Jarvik R: Axial flow pumps, in Goldstein DJ, Oz MC (eds), Cardiac Assist Devices. Armonk, NY: Futura Publishing, 2000, pp 359-373.
    • (2000) Cardiac Assist Devices , pp. 359-373
    • DeRose, J.1    Jarvik, R.2
  • 8
    • 12844280949 scopus 로고    scopus 로고
    • Treatment of heart failure: Assisted circulation
    • Braunwald E, Zipes D, Libby P (eds), Philadelphia, W.B. Saunders
    • Rickenbacher WE, Pierce WS: Treatment of heart failure: Assisted circulation, in Braunwald E, Zipes D, Libby P (eds), Heart Disease. Philadelphia, W.B. Saunders, 2001, pp. 600-614.
    • (2001) Heart Disease , pp. 600-614
    • Rickenbacher, W.E.1    Pierce, W.S.2
  • 9
    • 0015495957 scopus 로고
    • Pulsatile blood flow
    • Milnor WR: Pulsatile blood flow. N Engl J Med 287: 27-34, 1972.
    • (1972) N Engl J Med , vol.287 , pp. 27-34
    • Milnor, W.R.1
  • 10
    • 0036798185 scopus 로고    scopus 로고
    • End-organ function during chronic nonpulsatile circulation
    • Saito S, Westaby S, Piggot D, et al: End-organ function during chronic nonpulsatile circulation. Ann Thorac Surg 74: 1080-1085, 2002.
    • (2002) Ann Thorac Surg , vol.74 , pp. 1080-1085
    • Saito, S.1    Westaby, S.2    Piggot, D.3
  • 11
    • 13044312104 scopus 로고    scopus 로고
    • Physiology of nonpulsatile circulation: Acute versus chronic support
    • Jett GK: Physiology of nonpulsatile circulation: Acute versus chronic support. ASAIO J 45: 119-122, 1999.
    • (1999) ASAIO J , vol.45 , pp. 119-122
    • Jett, G.K.1
  • 12
    • 8544234289 scopus 로고    scopus 로고
    • Long-term evaluation of a nonpulsatile mechanical circulatory support system
    • Wakisaka Y, Taenaka Y, Chikanari K, et al: Long-term evaluation of a nonpulsatile mechanical circulatory support system. Artif Organs 21: 639-644, 1997.
    • (1997) Artif Organs , vol.21 , pp. 639-644
    • Wakisaka, Y.1    Taenaka, Y.2    Chikanari, K.3
  • 13
    • 0029969366 scopus 로고    scopus 로고
    • Chronic nonpulsatile blood flow. III. Effects of pump flow rate on oxygen transport and utilization in chronic nonpulsatile biventricular bypass
    • Tominaga R, Smith W, Massiello A, et al: Chronic nonpulsatile blood flow. III. Effects of pump flow rate on oxygen transport and utilization in chronic nonpulsatile biventricular bypass. J Thorac Cardiovasc Surg 111: 863-872, 1996.
    • (1996) J Thorac Cardiovasc Surg , vol.111 , pp. 863-872
    • Tominaga, R.1    Smith, W.2    Massiello, A.3
  • 14
    • 0028835096 scopus 로고
    • End organ function with prolonged nonpulsatile circulatory support
    • Reddy RC, Goldstein AH, Pacella JJ, et al: End organ function with prolonged nonpulsatile circulatory support. ASAIO J 41: M547-551, 1995.
    • (1995) ASAIO J , vol.41
    • Reddy, R.C.1    Goldstein, A.H.2    Pacella, J.J.3
  • 15
    • 0032974674 scopus 로고    scopus 로고
    • Major organ function under mechanical support: Comparative studies of pulsatile and nonpulsatile circulation
    • Sezai A, Shiono M, Orime Y, et al: Major organ function under mechanical support: Comparative studies of pulsatile and nonpulsatile circulation. Artif Organs 23: 280-285, 1999.
    • (1999) Artif Organs , vol.23 , pp. 280-285
    • Sezai, A.1    Shiono, M.2    Orime, Y.3
  • 16
    • 0032201247 scopus 로고    scopus 로고
    • Comparative study of artificial circulation for the liver after cardiogenic shock: Pulsatile or nonpulsatile?
    • Kohjima T: Comparative study of artificial circulation for the liver after cardiogenic shock: Pulsatile or nonpulsatile? Jpn J Thorac Cardiovasc Surg 46: 1117-1125, 1998.
    • (1998) Jpn J Thorac Cardiovasc Surg , vol.46 , pp. 1117-1125
    • Kohjima, T.1
  • 17
    • 8544243482 scopus 로고    scopus 로고
    • Renal circulation and cellular metabolism during left ventricular assisted circulation: Comparison study of pulsatile and nonpulsatile assists
    • Sezai A, Shiono M, Orime Y, et al: Renal circulation and cellular metabolism during left ventricular assisted circulation: Comparison study of pulsatile and nonpulsatile assists. Artif Organs 21: 830-835, 1997.
    • (1997) Artif Organs , vol.21 , pp. 830-835
    • Sezai, A.1    Shiono, M.2    Orime, Y.3
  • 18
    • 0030018274 scopus 로고    scopus 로고
    • Effect of pulsatile and nonpulsatile assist on heart and kidney microcirculation with cardiogenic shock
    • Nakata K, Shiono M, Orime Y, et al: Effect of pulsatile and nonpulsatile assist on heart and kidney microcirculation with cardiogenic shock. Artif Organs 20: 681-684, 1996.
    • (1996) Artif Organs , vol.20 , pp. 681-684
    • Nakata, K.1    Shiono, M.2    Orime, Y.3
  • 19
    • 0029972655 scopus 로고    scopus 로고
    • Comparison studies of major organ microcirculations under pulsatile- and nonpulsatile-assisted circulations
    • Sezai A, Shiono M, Orime Y, et al: Comparison studies of major organ microcirculations under pulsatile- and nonpulsatile-assisted circulations. Artif Organs 20: 139-142, 1996.
    • (1996) Artif Organs , vol.20 , pp. 139-142
    • Sezai, A.1    Shiono, M.2    Orime, Y.3
  • 20
    • 0028222727 scopus 로고
    • Counterpulsation: Historical background, technical improvements, hemodynamic and metabolic effects
    • Nanas JN, Moulopoulos SD: Counterpulsation: Historical background, technical improvements, hemodynamic and metabolic effects. Cardiology 84: 156-167, 1994.
    • (1994) Cardiology , vol.84 , pp. 156-167
    • Nanas, J.N.1    Moulopoulos, S.D.2
  • 21
    • 0022596454 scopus 로고
    • Comparison of an implanted abdominal aortic counterpulsation device with the intraaortic balloon pump in a heart failure model
    • Nanas JN, Mason JW, Taenaka Y, et al: Comparison of an implanted abdominal aortic counterpulsation device with the intraaortic balloon pump in a heart failure model. J Am Coll Cardiol 7: 1028-1035, 1986.
    • (1986) J Am Coll Cardiol , vol.7 , pp. 1028-1035
    • Nanas, J.N.1    Mason, J.W.2    Taenaka, Y.3
  • 22
    • 0027792029 scopus 로고
    • The limits of counterpulsation
    • Moulopoulos SD: The limits of counterpulsation. Int J Artif Organs 16: 803-805, 1993.
    • (1993) Int J Artif Organs , vol.16 , pp. 803-805
    • Moulopoulos, S.D.1
  • 23
    • 0031729439 scopus 로고    scopus 로고
    • The efficacy of the high volume counterpulsation technique at very low levels of aortic pressure
    • Charitos CE, Nanas JN, Kontoyiannis DA, et al: The efficacy of the high volume counterpulsation technique at very low levels of aortic pressure. J Cardiovasc Surg 39: 625-632, 1998.
    • (1998) J Cardiovasc Surg , vol.39 , pp. 625-632
    • Charitos, C.E.1    Nanas, J.N.2    Kontoyiannis, D.A.3
  • 24
    • 0018200958 scopus 로고
    • Mechanical properties of arteries
    • Dobrin PB: Mechanical properties of arteries. Physiol Rev 58: 397-460, 1978.
    • (1978) Physiol Rev , vol.58 , pp. 397-460
    • Dobrin, P.B.1
  • 25
    • 0021249532 scopus 로고
    • The static elastic properties of 45 human thoracic and 20 abdominal aortas in vitro and the parameters of a new model
    • Langewouters GJ, Wesseling KH, Goedhard WJ: The static elastic properties of 45 human thoracic and 20 abdominal aortas in vitro and the parameters of a new model. J Biomech 17: 425-435, 1984.
    • (1984) J Biomech , vol.17 , pp. 425-435
    • Langewouters, G.J.1    Wesseling, K.H.2    Goedhard, W.J.3
  • 26
    • 0028916513 scopus 로고
    • Nitric oxide synthesis by cultured endothelial cells is modulated by flow conditions
    • Noris M, Morigi M, Donadelli R, et al: Nitric oxide synthesis by cultured endothelial cells is modulated by flow conditions. Circ Res 76: 536-543, 1995.
    • (1995) Circ Res , vol.76 , pp. 536-543
    • Noris, M.1    Morigi, M.2    Donadelli, R.3
  • 27
    • 0034010554 scopus 로고    scopus 로고
    • Pulsatile flow enhances endothelium-derived nitric oxide release in the peripheral vasculature
    • Nakano T, Tominaga R, Nagano I, et al: Pulsatile flow enhances endothelium-derived nitric oxide release in the peripheral vasculature. Am J Physiol Heart Circ Physiol 278: H1098-1104, 2000.
    • (2000) Am J Physiol Heart Circ Physiol , vol.278
    • Nakano, T.1    Tominaga, R.2    Nagano, I.3
  • 28
    • 0013968954 scopus 로고
    • Hemodynamic effects of pulsatile and non- pulsatile flow
    • Giron F, Birtwell WC, Soroff HS, et al: Hemodynamic effects of pulsatile and non- pulsatile flow. Arch Surg 93: 802-810, 1966.
    • (1966) Arch Surg , vol.93 , pp. 802-810
    • Giron, F.1    Birtwell, W.C.2    Soroff, H.S.3
  • 29
    • 84931012864 scopus 로고
    • Effects of graded pulsatile pressure on the reflex vasomotor responses elicited by changes of mean pressure in the perfused carotid sinus-aortic arch regions of the dog
    • Angell-James J, Daly Mde B: Effects of graded pulsatile pressure on the reflex vasomotor responses elicited by changes of mean pressure in the perfused carotid sinus-aortic arch regions of the dog. J Physiol 214: 51-64, 1971.
    • (1971) J Physiol , vol.214 , pp. 51-64
    • Angell-James, J.1    Daly, M.D.B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.