메뉴 건너뛰기




Volumn 72, Issue 3, 2007, Pages 157-166

Identification and quantification of high fluorescence-stained lymphocytes as antibody synthesizing/secreting cells using the automated routine hematology analyzer XE-2100

Author keywords

Activated B lymphocytes; Antibody synthesizing cells (ASC); BD FACSCalibur ; Cellavision DIFF Master DM96; High fluorescence lymphocytes (HFL); SYSMEX XE 2100

Indexed keywords

ANALYZER; ANTIBODY PRODUCTION; B LYMPHOCYTE ACTIVATION; BLOOD SMEAR; CONTROLLED STUDY; FLUORESCENCE; HUMAN; HUMAN CELL; IMMUNOPHENOTYPING; LARGE GRANULAR LYMPHOCYTE; LYMPHOCYTE; LYMPHOCYTE COUNT; MOLECULAR MODEL; MONOCYTE; NATURAL KILLER CELL; PLASMA CELL; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; RELIABILITY; REPRODUCIBILITY; REVIEW; T LYMPHOCYTE ACTIVATION;

EID: 34247637113     PISSN: 15524949     EISSN: 15524957     Source Type: Journal    
DOI: 10.1002/cyto.b.20150     Document Type: Review
Times cited : (40)

References (18)
  • 1
    • 0036399616 scopus 로고    scopus 로고
    • Performance of the XE-2100 leucocyte differential
    • Stamminger G. Performance of the XE-2100 leucocyte differential. Clin Lab Haem 2002;24:271-280.
    • (2002) Clin Lab Haem , vol.24 , pp. 271-280
    • Stamminger, G.1
  • 2
    • 0034452663 scopus 로고    scopus 로고
    • New quantitative parameters on a recently introduced automated blood cell counter the XE-2100
    • Briggs C, Harrison P, Grant D, Staves J, MacHin SJ. New quantitative parameters on a recently introduced automated blood cell counter the XE-2100. Clin Lab Haematol 2000;22:345-350.
    • (2000) Clin Lab Haematol , vol.22 , pp. 345-350
    • Briggs, C.1    Harrison, P.2    Grant, D.3    Staves, J.4    MacHin, S.J.5
  • 3
    • 0003813056 scopus 로고    scopus 로고
    • The Immune System in Health and Disease
    • 5th ed. Heidelberg, Berlin: Spektrum Akademischer Verlag GmbH;
    • Janeway CA, Travers P, Walport M, Shlomchik M. The Immune System in Health and Disease. Immunobiology, 5th ed. Heidelberg, Berlin: Spektrum Akademischer Verlag GmbH; 2002.
    • (2002) Immunobiology
    • Janeway, C.A.1    Travers, P.2    Walport, M.3    Shlomchik, M.4
  • 4
    • 14944362858 scopus 로고    scopus 로고
    • Regulation of plasma-cell development
    • Shapiro-Shelef M, Calame K. Regulation of plasma-cell development. Nat Rev Immunol 2005;5:230-242.
    • (2005) Nat Rev Immunol , vol.5 , pp. 230-242
    • Shapiro-Shelef, M.1    Calame, K.2
  • 7
    • 0025951891 scopus 로고
    • Sites of specific B cell activation in primary and secondary responses to T cell-dependent and T cell-independent antigens
    • Liu YJ, Zhang J, Lane PJ, Chan EY, MacLennan IC. Sites of specific B cell activation in primary and secondary responses to T cell-dependent and T cell-independent antigens. Eur J Immunol 1991;21:2951-2962.
    • (1991) Eur J Immunol , vol.21 , pp. 2951-2962
    • Liu, Y.J.1    Zhang, J.2    Lane, P.J.3    Chan, E.Y.4    MacLennan, I.C.5
  • 8
    • 0028038426 scopus 로고    scopus 로고
    • MHC-dependent antigen processing and peptide presentation: Providing ligands for T-lymphocyte activation
    • Germain RN. MHC-dependent antigen processing and peptide presentation: Providing ligands for T-lymphocyte activation. Cell 1996;76:287-299.
    • (1996) Cell , vol.76 , pp. 287-299
    • Germain, R.N.1
  • 9
    • 27744498868 scopus 로고    scopus 로고
    • Follicular B helper T cells in antibody responses and autoimmunity
    • Vinuesa CG, Tangye SG, Moser B, Mackay CR. Follicular B helper T cells in antibody responses and autoimmunity. Nat Rev Immunol 2005;5:853-865.
    • (2005) Nat Rev Immunol , vol.5 , pp. 853-865
    • Vinuesa, C.G.1    Tangye, S.G.2    Moser, B.3    Mackay, C.R.4
  • 11
    • 34247574947 scopus 로고    scopus 로고
    • CLSI. H20-A2 Reference Leucocyte Differential Count (proportional) and Evaluation of Instrumental Methods. Approved Standard-2nd ed. Villanova, PA: Clinical and Laboratory Standards Institute. 19085; 2006.
    • CLSI. H20-A2 Reference Leucocyte Differential Count (proportional) and Evaluation of Instrumental Methods. Approved Standard-2nd ed. Villanova, PA: Clinical and Laboratory Standards Institute. 19085; 2006.
  • 12
    • 0038236960 scopus 로고    scopus 로고
    • Differential counting of blood leukocytes using automated microscopy and a decision support system based on artificial neural networks-evaluation of DiffMaster (DM) octavia
    • Swolin B, Simonsson P, Backman S, Lofqvist I, Bredin I, Johnsson M. Differential counting of blood leukocytes using automated microscopy and a decision support system based on artificial neural networks-evaluation of DiffMaster (DM) octavia. Clin Lab Haematol 2003;25:139-147.
    • (2003) Clin Lab Haematol , vol.25 , pp. 139-147
    • Swolin, B.1    Simonsson, P.2    Backman, S.3    Lofqvist, I.4    Bredin, I.5    Johnsson, M.6
  • 13
    • 21844440052 scopus 로고    scopus 로고
    • Tuning immune responses: Diversity and adaptation of the immunological synapse
    • Friedl P, den Boer AT, Gunzer M. Tuning immune responses: Diversity and adaptation of the immunological synapse. Nat Rev Immunol 2005;5:532-545.
    • (2005) Nat Rev Immunol , vol.5 , pp. 532-545
    • Friedl, P.1    den Boer, A.T.2    Gunzer, M.3
  • 14
    • 34247576469 scopus 로고    scopus 로고
    • Manual Mikroskopiekurs Hämatologie. A Practical Guide
    • Nora-Verlag GmbH;
    • Fuchs R. Manual Mikroskopiekurs Hämatologie. A Practical Guide. Stolberg: Nora-Verlag GmbH; 2005.
    • (2005) Stolberg
    • Fuchs, R.1
  • 15
    • 34247558862 scopus 로고
    • Blood Cells
    • Bain BJ, editor, Oxford: Blackwell;
    • Bain BJ, editor. Blood Cells. A Practical Guide. Oxford: Blackwell; 1995.
    • (1995) A Practical Guide
  • 18
    • 0016678148 scopus 로고
    • Normal values and least significant differences for differential leucocyte count
    • Rumke CL, Bezemer PD, Kuik DJ. Normal values and least significant differences for differential leucocyte count. J Chron Dis 1975;28:661-668.
    • (1975) J Chron Dis , vol.28 , pp. 661-668
    • Rumke, C.L.1    Bezemer, P.D.2    Kuik, D.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.