Volumn , Issue , 2009, Pages 21-30

Packaging and Sterilization of UHMWPE

Author keywords

[No Author keywords available]

Indexed keywords


EID: 79960969444     PISSN: None     EISSN: None     Source Type: Book    
DOI: 10.1016/B978-0-12-374721-1.00003-1     Document Type: Chapter
Times cited : (10)

References (42)
  • 1
    • 33745727024 scopus 로고    scopus 로고
    • Oxidation and oxidation potential in contemporary packaging for polyethylene total joint replacement components
    • July
    • Costa L, Bracco P, Brach del Prever EM, Kurtz SM, Gallinaro P Oxidation and oxidation potential in contemporary packaging for polyethylene total joint replacement components. J Biomed Mater Res B Appl Biomater 2006, 78(1):20-26. July.
    • (2006) J Biomed Mater Res B Appl Biomater , vol.78 , Issue.1 , pp. 20-26
    • Costa, L.1    Bracco, P.2    Brach Del Prever, E.M.3    Kurtz, S.M.4    Gallinaro, P.5
  • 3
    • 0030331025 scopus 로고    scopus 로고
    • An investigation into the origins of time-dependent variation in penetration rates with Charnley acetabular cups-wear, creep or degradation?
    • Isaac GH, Dowson D, Wroblewski BM An investigation into the origins of time-dependent variation in penetration rates with Charnley acetabular cups-wear, creep or degradation?. Proc Inst Mech Eng 1996, 210(3):209-216.
    • (1996) Proc Inst Mech Eng , vol.210 , Issue.3 , pp. 209-216
    • Isaac, G.H.1    Dowson, D.2    Wroblewski, B.M.3
  • 4
    • 0032775639 scopus 로고    scopus 로고
    • Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty
    • Kurtz SM, Muratoglu OK, Evans M, Edidin AA Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty. Biomaterials 1999, 20(18):1659-1688.
    • (1999) Biomaterials , vol.20 , Issue.18 , pp. 1659-1688
    • Kurtz, S.M.1    Muratoglu, O.K.2    Evans, M.3    Edidin, A.A.4
  • 5
    • 0026202775 scopus 로고
    • Combined chemical and mechanical effects on free radicals in UHMWPE joints during implantation
    • Jahan MS, Wang C Combined chemical and mechanical effects on free radicals in UHMWPE joints during implantation. J Biomed Mater Res 1991, 25:1005-1017.
    • (1991) J Biomed Mater Res , vol.25 , pp. 1005-1017
    • Jahan, M.S.1    Wang, C.2
  • 7
    • 0028102058 scopus 로고
    • Post-irradiation aging of ultra-high molecular weight polyethylene
    • Rimnac CM, Klein RW, Betts F, Wright TM Post-irradiation aging of ultra-high molecular weight polyethylene. J Bone Joint Surg 1994, 76A(7):1052-1056.
    • (1994) J Bone Joint Surg , vol.76 A , Issue.7 , pp. 1052-1056
    • Rimnac, C.M.1    Klein, R.W.2    Betts, F.3    Wright, T.M.4
  • 8
    • 0028584259 scopus 로고
    • The natural history of ultra-high molecular weight polyethylene
    • Bostrom MP, Bennett AP, Rimnac CM, Wright TM The natural history of ultra-high molecular weight polyethylene. Clin Orthop 1994, 309(309):20-28.
    • (1994) Clin Orthop , vol.309 , Issue.309 , pp. 20-28
    • Bostrom, M.P.1    Bennett, A.P.2    Rimnac, C.M.3    Wright, T.M.4
  • 9
    • 0031039389 scopus 로고    scopus 로고
    • Degradation rate of ultra-high molecular weight polyethylene
    • Kurtz SM, Rimnac CM, Bartel DL Degradation rate of ultra-high molecular weight polyethylene. J Orthop Res 1997, 15(1):57-61.
    • (1997) J Orthop Res , vol.15 , Issue.1 , pp. 57-61
    • Kurtz, S.M.1    Rimnac, C.M.2    Bartel, D.L.3
  • 10
    • 0031981874 scopus 로고    scopus 로고
    • Post-irradiation aging affects the stresses and strains in UHMWPE components for total joint replacement
    • Kurtz SM, Bartel DL, Rimnac CM Post-irradiation aging affects the stresses and strains in UHMWPE components for total joint replacement. Clin Orthop 1998, 350:209-220.
    • (1998) Clin Orthop , vol.350 , pp. 209-220
    • Kurtz, S.M.1    Bartel, D.L.2    Rimnac, C.M.3
  • 11
    • 0034110406 scopus 로고    scopus 로고
    • Degradation of mechanical behavior in UHMWPE after natural and accelerated aging
    • Edidin AA, Jewett CW, Kwarteng K, Kalinowski A, Kurtz SM Degradation of mechanical behavior in UHMWPE after natural and accelerated aging. Biomaterials 2000, 21(14):1451-1460.
    • (2000) Biomaterials , vol.21 , Issue.14 , pp. 1451-1460
    • Edidin, A.A.1    Jewett, C.W.2    Kwarteng, K.3    Kalinowski, A.4    Kurtz, S.M.5
  • 14
    • 0034114072 scopus 로고    scopus 로고
    • Contact fatigue failure of ultra-high molecular weight polyethylene bearing components of knee prostheses
    • Kennedy FE, Currier JH, Plumet S, Duda JL, Gestwick DP, Collier JP, et al. Contact fatigue failure of ultra-high molecular weight polyethylene bearing components of knee prostheses. J Tribol 2000, 122:332-339.
    • (2000) J Tribol , vol.122 , pp. 332-339
    • Kennedy, F.E.1    Currier, J.H.2    Plumet, S.3    Duda, J.L.4    Gestwick, D.P.5    Collier, J.P.6
  • 15
    • 0036599928 scopus 로고    scopus 로고
    • Rapid polyethylene failure of unicondylar tibial components sterilized with gamma irradiation in air and implanted after a long shelf life
    • June
    • McGovern TF, Ammeen DJ, Collier JP, Currier BH, Engh GA Rapid polyethylene failure of unicondylar tibial components sterilized with gamma irradiation in air and implanted after a long shelf life. J Bone Joint Surg Am 2002, 84-A(6):901-906. June.
    • (2002) J Bone Joint Surg Am , Issue.6 , pp. 901-906
    • McGovern, T.F.1    Ammeen, D.J.2    Collier, J.P.3    Currier, B.H.4    Engh, G.A.5
  • 16
    • 84882487196 scopus 로고    scopus 로고
    • Orthopaedic Products. In: Smith RC, Geier MA, Reno J, Sarasohn-Kahn J, editors. Medical & Healthcare Marketplace Guide. New York: IDD Enterprises, L.P.; 1996. p. 265-72.
    • Orthopaedic Products. In: Smith RC, Geier MA, Reno J, Sarasohn-Kahn J, editors. Medical & Healthcare Marketplace Guide. New York: IDD Enterprises, L.P.; 1996. p. 265-72.
  • 17
    • 0033065656 scopus 로고    scopus 로고
    • Effect of molecular weight, calcium stearate, and sterilization methods on the wear of ultra-high molecular weight polyethylene acetabular cups in a hip simulator
    • McKellop HA, Shen F-W, Campbell P, Ota T Effect of molecular weight, calcium stearate, and sterilization methods on the wear of ultra-high molecular weight polyethylene acetabular cups in a hip simulator. J Orthop Res 1999, 17(3):329-339.
    • (1999) J Orthop Res , vol.17 , Issue.3 , pp. 329-339
    • McKellop, H.A.1    Shen, F.-W.2    Campbell, P.3    Ota, T.4
  • 18
    • 0031594091 scopus 로고    scopus 로고
    • Lubrication and wear of ultra-high molecular weight polyethylene in total joint replacements
    • Wang A, Essner A, Polineni VK, Stark C, Dumbleton JH Lubrication and wear of ultra-high molecular weight polyethylene in total joint replacements. Tribol Int 1998, 31(1-3):17-33.
    • (1998) Tribol Int , vol.31 , Issue.1-3 , pp. 17-33
    • Wang, A.1    Essner, A.2    Polineni, V.K.3    Stark, C.4    Dumbleton, J.H.5
  • 19
    • 0037365495 scopus 로고    scopus 로고
    • Effect of terminal sterilization with gas plasma or gamma radiation on wear of polyethylene liners
    • March
    • Hopper RH, Young, AM, Orishimo KF, Engh CA Effect of terminal sterilization with gas plasma or gamma radiation on wear of polyethylene liners. J Bone Joint Surg Am 2003, 85-A(3):464-468. March.
    • (2003) J Bone Joint Surg Am , Issue.3 , pp. 464-468
    • Hopper, R.H.1    Young, A.M.2    Orishimo, K.F.3    Engh, C.A.4
  • 20
    • 2442608349 scopus 로고    scopus 로고
    • Sterilization and polyethylene wear: clinical studies to support laboratory data
    • May
    • Sychterz CJ, Orishimo KF, Engh CA Sterilization and polyethylene wear: clinical studies to support laboratory data. J Bone Joint Surg Am 2004, 86-A(5):1017-1022. May.
    • (2004) J Bone Joint Surg Am , Issue.5 , pp. 1017-1022
    • Sychterz, C.J.1    Orishimo, K.F.2    Engh, C.A.3
  • 21
    • 0023688210 scopus 로고
    • Radiation sterilization of polymeric implant materials
    • A2 SUPPL.
    • Bruck SD, Mueller EP Radiation sterilization of polymeric implant materials. J Biomed Mater Res 1988, 22(A2 Suppl.):133-144.
    • (1988) J Biomed Mater Res , vol.22 , pp. 133-144
    • Bruck, S.D.1    Mueller, E.P.2
  • 22
    • 0029999567 scopus 로고    scopus 로고
    • Safety and efficacy of ethylene oxide sterilized polyethylene in total knee arthroplasty
    • Ries MD, Weaver K, Beals N Safety and efficacy of ethylene oxide sterilized polyethylene in total knee arthroplasty. Clin Orthop 1996, 331:159-163.
    • (1996) Clin Orthop , vol.331 , pp. 159-163
    • Ries, M.D.1    Weaver, K.2    Beals, N.3
  • 23
    • 0032002460 scopus 로고    scopus 로고
    • A guide to AAMI's TIR for EtO-sterilized medical devices
    • Page BFJ, Cyr H A guide to AAMI's TIR for EtO-sterilized medical devices. Med Dev Diag Indust 1998, 20(2):73-78.
    • (1998) Med Dev Diag Indust , vol.20 , Issue.2 , pp. 73-78
    • Page, B.F.J.1    Cyr, H.2
  • 24
    • 0031260268 scopus 로고    scopus 로고
    • Oxidation of ultrahigh molecular weight polyethylene characterized by Fourier Transform Infrared Spectrometry
    • Goldman M, Lee M, Gronsky R, Pruitt L Oxidation of ultrahigh molecular weight polyethylene characterized by Fourier Transform Infrared Spectrometry. J Biomed Mater Res 1997, 37(1):43-50.
    • (1997) J Biomed Mater Res , vol.37 , Issue.1 , pp. 43-50
    • Goldman, M.1    Lee, M.2    Gronsky, R.3    Pruitt, L.4
  • 26
    • 0030454582 scopus 로고    scopus 로고
    • Fatigue strength of polyethylene after sterilization by gamma irradiation or ethylene oxide
    • Ries MD, Weaver K, Rose RM, Gunther J, Sauer W, Beals N Fatigue strength of polyethylene after sterilization by gamma irradiation or ethylene oxide. Clin Orthop 1996, 333:87-95.
    • (1996) Clin Orthop , vol.333 , pp. 87-95
    • Ries, M.D.1    Weaver, K.2    Rose, R.M.3    Gunther, J.4    Sauer, W.5    Beals, N.6
  • 27
    • 0006544376 scopus 로고    scopus 로고
    • Orientation softening in the deformation and wear of ultra-high molecular weight polyethylene
    • Wang A, Sun DC, Yau S-S, Edwards B, Sokol M, Essner A, et al. Orientation softening in the deformation and wear of ultra-high molecular weight polyethylene. Wear 1997, 203-204:230-241.
    • (1997) Wear , vol.203-204 , pp. 230-241
    • Wang, A.1    Sun, D.C.2    Yau, S.-S.3    Edwards, B.4    Sokol, M.5    Essner, A.6
  • 28
    • 0029859316 scopus 로고    scopus 로고
    • Effects of sterilization on wear in total knee arthroplasty
    • White SE, Paxson RD, Tanner MG, Whiteside LA Effects of sterilization on wear in total knee arthroplasty. Clin Orthop 1996, 331(331):164-171.
    • (1996) Clin Orthop , vol.331 , Issue.331 , pp. 164-171
    • White, S.E.1    Paxson, R.D.2    Tanner, M.G.3    Whiteside, L.A.4
  • 30
    • 0032486507 scopus 로고    scopus 로고
    • Comparison of the effects of gamma radiation and low temperature hydrogen peroxide gas plasma sterilization on the molecular structure, fatigue resistance, and wear behavior of UHMWPE
    • June 5
    • Goldman M, Pruitt L Comparison of the effects of gamma radiation and low temperature hydrogen peroxide gas plasma sterilization on the molecular structure, fatigue resistance, and wear behavior of UHMWPE. J Biomed Mater Res 1998, 40(3):378-384. June 5.
    • (1998) J Biomed Mater Res , vol.40 , Issue.3 , pp. 378-384
    • Goldman, M.1    Pruitt, L.2
  • 31
    • 0031352886 scopus 로고    scopus 로고
    • Compatibility of medical devices and materials with low-temperature hydrogen peroxide gas plasma
    • Feldman LA, Hui HK Compatibility of medical devices and materials with low-temperature hydrogen peroxide gas plasma. Med Dev Diag Indust 1997, 19(12):57-62.
    • (1997) Med Dev Diag Indust , vol.19 , Issue.12 , pp. 57-62
    • Feldman, L.A.1    Hui, H.K.2
  • 32
    • 0029559446 scopus 로고
    • Assessment of the efficacy of a low temperature hydrogen peroxide gas plasma sterilization system
    • Kyi MS, Holton J, Ridgway GL Assessment of the efficacy of a low temperature hydrogen peroxide gas plasma sterilization system. J Hosp Infect 1995, 31(4):275-284.
    • (1995) J Hosp Infect , vol.31 , Issue.4 , pp. 275-284
    • Kyi, M.S.1    Holton, J.2    Ridgway, G.L.3
  • 33
    • 0033642582 scopus 로고    scopus 로고
    • Comparison of gas plasma and gamma irradiation in air sterilization on the delamination wear of the ultra-high molecular weight polyethylene used in knee replacements
    • Reeves EA, Barton DC, FitzPatrick DP, Fisher J Comparison of gas plasma and gamma irradiation in air sterilization on the delamination wear of the ultra-high molecular weight polyethylene used in knee replacements. Proceedings of the Institution of Mechanical Engineers 2000, 214(3):249-255.
    • (2000) Proceedings of the Institution of Mechanical Engineers , vol.214 , Issue.3 , pp. 249-255
    • Reeves, E.A.1    Barton, D.C.2    FitzPatrick, D.P.3    Fisher, J.4
  • 34
    • 0037210094 scopus 로고    scopus 로고
    • Isothermal microcalorimetry: an analytical technique for assessing the dynamic chemical stability of UHMWPE
    • January
    • Charlebois SJ, Daniels AU, Lewis G Isothermal microcalorimetry: an analytical technique for assessing the dynamic chemical stability of UHMWPE. Biomaterials 2003, 24(2):291-296. January.
    • (2003) Biomaterials , vol.24 , Issue.2 , pp. 291-296
    • Charlebois, S.J.1    Daniels, A.U.2    Lewis, G.3
  • 35
    • 0033637708 scopus 로고    scopus 로고
    • Effect of sterilization method and other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight polyethylene. A hip-simulator study
    • December
    • McKellop H, Shen FW, Lu B, Campbell P, Salovey R Effect of sterilization method and other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight polyethylene. A hip-simulator study. J Bone Joint Surg Am 2000, 82-A(12):1708-1725. December.
    • (2000) J Bone Joint Surg Am , Issue.12 , pp. 1708-1725
    • McKellop, H.1    Shen, F.W.2    Lu, B.3    Campbell, P.4    Salovey, R.5
  • 37
    • 84882552200 scopus 로고    scopus 로고
    • Ultra-High Molecular Weight Polyethylene (UHMWPE) components of joint replacement implants. Medical Devices Agency Safety Notice MDA SN 9816; 1998.
    • Ultra-High Molecular Weight Polyethylene (UHMWPE) components of joint replacement implants. Medical Devices Agency Safety Notice MDA SN 9816; 1998.
  • 38
    • 84882539425 scopus 로고    scopus 로고
    • ASTM F 1980-02. Standard guide for accelerated aging of sterile medical device packages. West Conshohocken, PA: American Society for Testing and Materials; 2002.
    • ASTM F 1980-02. Standard guide for accelerated aging of sterile medical device packages. West Conshohocken, PA: American Society for Testing and Materials; 2002.
  • 40
    • 33745683046 scopus 로고    scopus 로고
    • A prospective study of the effects of five years shelf aging on the properties of UHMWPE following gamma sterilization in air or in a vacuum foil pouch
    • Greer K. A prospective study of the effects of five years shelf aging on the properties of UHMWPE following gamma sterilization in air or in a vacuum foil pouch. Transactions of the 28th Society for Biomaterials; 2003. p. 378.
    • (2003) Transactions of the 28th Society for Biomaterials , pp. 378
    • Greer, K.1
  • 41
    • 0024174065 scopus 로고
    • Ionizing irradiation for sterilization and modification of high molecular weight polyethylenes
    • Streicher RM Ionizing irradiation for sterilization and modification of high molecular weight polyethylenes. Plast Rubber Proc Appl 1988, 10(4):221-229.
    • (1988) Plast Rubber Proc Appl , vol.10 , Issue.4 , pp. 221-229
    • Streicher, R.M.1
  • 42
    • 0037210116 scopus 로고    scopus 로고
    • The influence of inert packaging on the shelf ageing of gamma-irradiation sterilised ultra-high molecular weight polyethylene
    • January
    • Lu S, Orr JF, Buchanan FJ The influence of inert packaging on the shelf ageing of gamma-irradiation sterilised ultra-high molecular weight polyethylene. Biomaterials 2003, 24(1):139-145. January.
    • (2003) Biomaterials , vol.24 , Issue.1 , pp. 139-145
    • Lu, S.1    Orr, J.F.2    Buchanan, F.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.