Understanding the dual mobility concept for total hip arthroplasty. Investigations on a multiscale analysis-highlighting the role of arthrofibrosis

Author keywords

Dual mobility concept; Surface roughness; Total hip arthroplasty; Ultra high molecular weight polyethylene; Wear mechanism

Indexed keywords

3-D PROFILOMETRY; ARTIFICIAL JOINT; DUAL MOBILITY CONCEPT; EXTERNAL SURFACES; FEMORAL STEMS; HIP IMPLANTS; LINER WEAR; MACROSCOPIC SCALE; METAL TRANSFERS; MULTISCALES; TOTAL HIP ARTHROPLASTY; TRIBOLOGICAL BEHAVIORS; WEAR MECHANISMS; WEAR VOLUME; WEAR ZONES;

EID: 79960687900     PISSN: 00431648     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.wear.2011.02.027     Document Type: Article
Times cited : (44)

References (31)
  • 1
    • 79960663772 scopus 로고    scopus 로고
    • The history of total hip arthroplasty
    • Elsevier, Paris, L.C.J. Puget (Ed.)
    • Hernigou P., Poignard A., Manicom O. The history of total hip arthroplasty. Prothèse totale de hanche 2005, 5-9. Elsevier, Paris. L.C.J. Puget (Ed.).
    • (2005) Prothèse totale de hanche , pp. 5-9
    • Hernigou, P.1    Poignard, A.2    Manicom, O.3
  • 2
    • 0013912485 scopus 로고
    • Replacement of arthritic hips prosthesis
    • McKee G.K., Watson-Farrar J. Replacement of arthritic hips prosthesis. J. Bone Joint Surg. 1966, 48B:245-259.
    • (1966) J. Bone Joint Surg. , vol.48 B , pp. 245-259
    • McKee, G.K.1    Watson-Farrar, J.2
  • 3
    • 0015319816 scopus 로고
    • Arthroplastie totale de la hanche par prothèse en alumine frittée
    • Boutin P. Arthroplastie totale de la hanche par prothèse en alumine frittée. Rev. Chir. Orthop. 1972, 58:229.
    • (1972) Rev. Chir. Orthop. , vol.58 , pp. 229
    • Boutin, P.1
  • 11
    • 0031712391 scopus 로고    scopus 로고
    • Results with a cementless alumina-coated cup with dual mobility. A twelve-year follow-up study
    • Farizon F., de Lavison R., Azoulai J.-J., Bousquet G. Results with a cementless alumina-coated cup with dual mobility. A twelve-year follow-up study. Int. Orthopaed. 1998, 22:219-224.
    • (1998) Int. Orthopaed. , vol.22 , pp. 219-224
    • Farizon, F.1    de Lavison, R.2    Azoulai, J.-J.3    Bousquet, G.4
  • 15
    • 68349086967 scopus 로고    scopus 로고
    • The use of a dual-articulation acetabular cup system to prevent dislocation after primary total hip arthroplasty: analysis of 384 cases at a mean follow-up of 15 years
    • Philippot R., Camilleri J.-P., Boyer B., Adam P., Farizon F. The use of a dual-articulation acetabular cup system to prevent dislocation after primary total hip arthroplasty: analysis of 384 cases at a mean follow-up of 15 years. Int. Orthopaed. 2009, 33:927-932.
    • (2009) Int. Orthopaed. , vol.33 , pp. 927-932
    • Philippot, R.1    Camilleri, J.-P.2    Boyer, B.3    Adam, P.4    Farizon, F.5
  • 17
    • 0036023527 scopus 로고    scopus 로고
    • A literature review of the association between wear rate and osteolysis in total hip arthroplasty
    • Dumbleton J.H., Manley M.T., Edidin A.A. A literature review of the association between wear rate and osteolysis in total hip arthroplasty. J. Arthroplasty 2002, 17:649-661.
    • (2002) J. Arthroplasty , vol.17 , pp. 649-661
    • Dumbleton, J.H.1    Manley, M.T.2    Edidin, A.A.3
  • 18
    • 0032880179 scopus 로고    scopus 로고
    • Effect of polyethylene wear on osteolysis in cementless primary total hip arthroplasty: minimal 5-year follow-up study
    • Han C.D., Choe W.S., Yoo J.H. Effect of polyethylene wear on osteolysis in cementless primary total hip arthroplasty: minimal 5-year follow-up study. J. Arthroplasty 1999, 14:714-723.
    • (1999) J. Arthroplasty , vol.14 , pp. 714-723
    • Han, C.D.1    Choe, W.S.2    Yoo, J.H.3
  • 20
    • 34748921063 scopus 로고    scopus 로고
    • Wear particles, periprosthetic osteolysis and the immune system
    • Goodman S.B. Wear particles, periprosthetic osteolysis and the immune system. Biomaterials 2007, 28:5044-5048.
    • (2007) Biomaterials , vol.28 , pp. 5044-5048
    • Goodman, S.B.1
  • 21
    • 0031544132 scopus 로고    scopus 로고
    • Three-dimensional polyethylene wear of a press-fit titanium prosthesis
    • Devane P.A., Horne J.G., Martin K., Coldham G., Krause B. Three-dimensional polyethylene wear of a press-fit titanium prosthesis. J. Arthroplasty 1997, 12:256-266.
    • (1997) J. Arthroplasty , vol.12 , pp. 256-266
    • Devane, P.A.1    Horne, J.G.2    Martin, K.3    Coldham, G.4    Krause, B.5
  • 22
    • 0015754154 scopus 로고
    • Ectopic ossification following total hip replacement, Incidence and a method of classification
    • Brooker A.F., Bowerman J.W., Robinson R.A., et al. Ectopic ossification following total hip replacement, Incidence and a method of classification. J. Bone Joint Surg. Am. 1973, 55:1629-1632.
    • (1973) J. Bone Joint Surg. Am. , vol.55 , pp. 1629-1632
    • Brooker, A.F.1    Bowerman, J.W.2    Robinson, R.A.3
  • 23
    • 58249141998 scopus 로고    scopus 로고
    • Heterotopic ossification after surface replacement arthroplasty and total hip arthroplasty: a randomized study
    • Boddu Siva Rama K.R., Vendittoli P.-A., Ganapathi M., Borgmann R., Roy A., Lavigne M. Heterotopic ossification after surface replacement arthroplasty and total hip arthroplasty: a randomized study. J. Arthroplasty 2009, 24:256-262.
    • (2009) J. Arthroplasty , vol.24 , pp. 256-262
    • Boddu Siva Rama, K.R.1    Vendittoli, P.-A.2    Ganapathi, M.3    Borgmann, R.4    Roy, A.5    Lavigne, M.6
  • 24
    • 0032618979 scopus 로고    scopus 로고
    • Three-dimensional surface characterization for orthopaedic joint prostheses
    • Xiang X.Q., Blunt L., Stout K.J. Three-dimensional surface characterization for orthopaedic joint prostheses. Proc. Inst. Mech. Eng. 1999, 213 Part H:49-68.
    • (1999) Proc. Inst. Mech. Eng. , vol.213 PART H , pp. 49-68
    • Xiang, X.Q.1    Blunt, L.2    Stout, K.J.3
  • 25
    • 0034069587 scopus 로고    scopus 로고
    • Three dimensional measurement of the surface topography of ceramic and metallic orthopaedic joint prostheses
    • Blunt L., Xiang X.Q. Three dimensional measurement of the surface topography of ceramic and metallic orthopaedic joint prostheses. J. Mater. Sci. Mater. Med. 2000, 11:235-246.
    • (2000) J. Mater. Sci. Mater. Med. , vol.11 , pp. 235-246
    • Blunt, L.1    Xiang, X.Q.2
  • 26
    • 33747426979 scopus 로고    scopus 로고
    • About the relevance of roughness parameters used for characterizing worn femoral heads
    • Najjar D., Bigerelle M., Migaud H., Iost A. About the relevance of roughness parameters used for characterizing worn femoral heads. Tribol. Int. 2006, 39:1527-1537.
    • (2006) Tribol. Int. , vol.39 , pp. 1527-1537
    • Najjar, D.1    Bigerelle, M.2    Migaud, H.3    Iost, A.4
  • 27
    • 8344283612 scopus 로고    scopus 로고
    • Topograpical parameters for specifying a three-dimensional surface
    • Peltonen J., Järn M., Areva S., Linden M., Rosenholm J.B. Topograpical parameters for specifying a three-dimensional surface. Langmuir 2004, 20:9428-9431.
    • (2004) Langmuir , vol.20 , pp. 9428-9431
    • Peltonen, J.1    Järn, M.2    Areva, S.3    Linden, M.4    Rosenholm, J.B.5
  • 28
    • 58149085981 scopus 로고    scopus 로고
    • The role of tribology and metrology in the latest development of bio-materials
    • Blunt L., Bills P., Jiang X., Hardaker C., Chakrabarty G. The role of tribology and metrology in the latest development of bio-materials. Wear 2009, 266:424-431.
    • (2009) Wear , vol.266 , pp. 424-431
    • Blunt, L.1    Bills, P.2    Jiang, X.3    Hardaker, C.4    Chakrabarty, G.5
  • 30
    • 0030903723 scopus 로고    scopus 로고
    • Wear of polyethylene acetabular components in total hip arthroplasty. An analysis of one hundred and twenty-eight components retrieved at autopsy or revision operations
    • Jasty M., Goetz D.D., Bragdon C.R., Lee K.R., Hanson A.E., Elder J.R., Harris W.H. Wear of polyethylene acetabular components in total hip arthroplasty. An analysis of one hundred and twenty-eight components retrieved at autopsy or revision operations. J. Bone Joint Surg. Am. 1997, 79:349-358.
    • (1997) J. Bone Joint Surg. Am. , vol.79 , pp. 349-358
    • Jasty, M.1    Goetz, D.D.2    Bragdon, C.R.3    Lee, K.R.4    Hanson, A.E.5    Elder, J.R.6    Harris, W.H.7
  • 31
    • 73149091204 scopus 로고    scopus 로고
    • Wear comparison between a dual mobility total hip prosthesis and a physical modular design using a hip joint simulator
    • Saikko V., Shen M. Wear comparison between a dual mobility total hip prosthesis and a physical modular design using a hip joint simulator. Wear 2010, 268:617-621.
    • (2010) Wear , vol.268 , pp. 617-621
    • Saikko, V.1    Shen, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.