메뉴 건너뛰기




Volumn 124, Issue 14, 2011, Pages 2150-2157

Early results of reverse less invasive stabilization system plating in treating elderly intertrochanteric fractures: A prospective study compared to proximal femoral nail

Author keywords

Intertrochanteric femur fracture; Less invasive stabilization system; Osteoporosis; Proximal femoral nail; Unstable fracture

Indexed keywords

AGED; ARTICLE; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; FEMALE; FEMUR INTERTROCHANTERIC FRACTURE; FOLLOW UP; FRACTURE FIXATION; FRACTURE NONUNION; HARRIS HIP SCORE; HEMOGLOBIN DETERMINATION; HIP PAIN; HUMAN; INTERMETHOD COMPARISON; INTRAMEDULLARY NAILING; LEG INEQUALITY; LESS INVASIVE STABILIZATION SYSTEM PLATING; MAJOR CLINICAL STUDY; MALE; OPERATION DURATION; PROSPECTIVE STUDY; SCORING SYSTEM; TREATMENT OUTCOME; VARUS DEFORMITY;

EID: 79960687647     PISSN: 03666999     EISSN: None     Source Type: Journal    
DOI: 10.3760/cma.j.issn.0366-6999.2011.14.013     Document Type: Article
Times cited : (14)

References (40)
  • 1
    • 1342326073 scopus 로고    scopus 로고
    • Intramedullary fixation of pertrochanteric hip fractures with the short AO-ASIF proximal femoral nail
    • Fogagnolo F, Kfuri M, Paccola CAJ. Intramedullary fixation of pertrochanteric hip fractures with the short AO-ASIF proximal femoral nail. Arch Orthop Trauma Surg 2004; 124: 31-37.
    • (2004) Arch Orthop Trauma Surg , vol.124 , pp. 31-37
    • Fogagnolo, F.1    Kfuri, M.2    Paccola, C.A.J.3
  • 3
    • 15944391459 scopus 로고    scopus 로고
    • Internal fixator of distal femur fractures with the Less Invasive Stabilizing System (LISS)
    • Schandelmaier P, Blauth M, Krettek C. Internal fixator of distal femur fractures with the Less Invasive Stabilizing System (LISS). Orthop Traumatol 2001; 9: 166-184.
    • (2001) Orthop Traumatol , vol.9 , pp. 166-184
    • Schandelmaier, P.1    Blauth, M.2    Krettek, C.3
  • 4
    • 77949264313 scopus 로고    scopus 로고
    • Reversed LISS-DF in selected cases of complex proximal femur fractures
    • Acklin YP, Bereiter H, Sommer C. Reversed LISS-DF in selected cases of complex proximal femur fractures. Injury 2009; 427-429.
    • (2009) Injury , pp. 427-429
    • Acklin, Y.P.1    Bereiter, H.2    Sommer, C.3
  • 5
    • 33845921610 scopus 로고    scopus 로고
    • Reverse LISS plating for proximal segmental femoral fractures in the polytrauma patient: A case report
    • Lewis P, Ashcroft GP. Reverse LISS plating for proximal segmental femoral fractures in the polytrauma patient: A case report. Injury 2007; 38: 235-239.
    • (2007) Injury , vol.38 , pp. 235-239
    • Lewis, P.1    Ashcroft, G.P.2
  • 6
    • 67849101112 scopus 로고    scopus 로고
    • Minimally invasive management of unstable proximal femoral extracapsular fractures using reverse LISS femoral locking plates
    • Ozkaya U, Bilgili F, Kilic A, Parmaksizoglu AS, Kabukcuoglu Y. Minimally invasive management of unstable proximal femoral extracapsular fractures using reverse LISS femoral locking plates. Hip Int 2009; 19: 141-147.
    • (2009) Hip Int , vol.19 , pp. 141-147
    • Ozkaya, U.1    Bilgili, F.2    Kilic, A.3    Parmaksizoglu, A.S.4    Kabukcuoglu, Y.5
  • 7
    • 0033034509 scopus 로고    scopus 로고
    • The AO/ASIF proximal femoral nail (PFN): A new device for the treatment of unstable proximal
    • Simmermacher RK, Bosch AM, Van der Werken CH. The AO/ASIF proximal femoral nail (PFN): a new device for the treatment of unstable proximal. Injury 1999; 30: 327-332.
    • (1999) Injury , vol.30 , pp. 327-332
    • Simmermacher, R.K.1    Bosch, A.M.2    van der Werken, C.H.3
  • 9
    • 36249026607 scopus 로고    scopus 로고
    • Survival and functional outcome according to hip fracture type: A one-year prospective cohort study in elderly women with an intertrochanteric or femoral neck fracture
    • Haentjens P, Autier P, Barette M, Venken K, Vanderschueren D, Boonen S. Survival and functional outcome according to hip fracture type: A one-year prospective cohort study in elderly women with an intertrochanteric or femoral neck fracture. Bone 2007; 41: 958-964.
    • (2007) Bone , vol.41 , pp. 958-964
    • Haentjens, P.1    Autier, P.2    Barette, M.3    Venken, K.4    Vanderschueren, D.5    Boonen, S.6
  • 10
    • 41849129556 scopus 로고    scopus 로고
    • Nail or plate fixation of intertrochanteric hip fractures: Changing pattern of practice: A review of the American Board of Orthopaedic Surgery Database
    • Anglen JO, Weinstein JN. Nail or plate fixation of intertrochanteric hip fractures: Changing pattern of practice: A review of the American Board of Orthopaedic Surgery Database. J Bone Joint Surg Am 2008; 90: 700-707.
    • (2008) J Bone Joint Surg Am , vol.90 , pp. 700-707
    • Anglen, J.O.1    Weinstein, J.N.2
  • 11
    • 33646114311 scopus 로고    scopus 로고
    • The trochanteric nail versus the sliding hip screw for intertrochanteric hip fractures: A review of 93 cases
    • Crawford CH, Malkani AL, Cordray S, Roberts CS, Sligar W. The trochanteric nail versus the sliding hip screw for intertrochanteric hip fractures: a review of 93 cases. J Trauma 2006; 60: 325-329.
    • (2006) J Trauma , vol.60 , pp. 325-329
    • Crawford, C.H.1    Malkani, A.L.2    Cordray, S.3    Roberts, C.S.4    Sligar, W.5
  • 12
    • 55049113315 scopus 로고    scopus 로고
    • Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults
    • Parker MJ, Handoll HH. Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults. Cochrane Database Syst Rev 2005; 4: CD000093.
    • (2005) Cochrane Database Syst Rev , vol.4
    • Parker, M.J.1    Handoll, H.H.2
  • 13
    • 34548133166 scopus 로고    scopus 로고
    • Are there advances in the treatment of extracapsular hip fractures in elderly?
    • Stern R. Are there advances in the treatment of extracapsular hip fractures in elderly? Injury 2007; 38 Suppl 3: S77-S87.
    • (2007) Injury , vol.38 , Issue.SUPPL. 3
    • Stern, R.1
  • 14
    • 17644364373 scopus 로고    scopus 로고
    • Trochanteric Gamma nail and compression hip screw for trochanteric fractures: A randomized, prospective, comparative study in 210 elderly patients with a new design of the Gamma nail
    • Utrilla AL, Reig JS, Mun FM. Trochanteric Gamma nail and compression hip screw for trochanteric fractures: A randomized, prospective, comparative study in 210 elderly patients with a new design of the Gamma nail. J Orthop Trauma 2005; 19: 229-233.
    • (2005) J Orthop Trauma , vol.19 , pp. 229-233
    • Utrilla, A.L.1    Reig, J.S.2    Mun, F.M.3
  • 15
    • 0035749514 scopus 로고    scopus 로고
    • Distal femoral fracture fixation utilizing the Less Invasive Stabilization System (L.I.S.S.): The technique and early results
    • Kregor PJ, Stannard J, Zlowodzki M, Cole PA, Alonso J. Distal femoral fracture fixation utilizing the Less Invasive Stabilization System (L.I.S.S.): the technique and early results. Injury 2001; 32 Suppl 3: SC32-SC47.
    • (2001) Injury , vol.32 , Issue.SUPPL. 3
    • Kregor, P.J.1    Stannard, J.2    Zlowodzki, M.3    Cole, P.A.4    Alonso, J.5
  • 16
    • 4444246142 scopus 로고    scopus 로고
    • Femur-LISS and distal femoral nail for fixation of distal femoral fractures
    • Markmiller M, Konrad G, Südkamp N. Femur-LISS and distal femoral nail for fixation of distal femoral fractures. Clin Orthop Relat Res 2004; 426: 252-257.
    • (2004) Clin Orthop Relat Res , vol.426 , pp. 252-257
    • Markmiller, M.1    Konrad, G.2    Südkamp, N.3
  • 17
    • 0035749814 scopus 로고    scopus 로고
    • Minimally invasive fracture stabilization of distal femoral fractures with the LISS: A prospective multicenter study. Result of a clinical study with special emphasis on difficult cases
    • Schutz M, Muller M, Krettek C, Regazzoni P, Ganz R, Haas N. Minimally invasive fracture stabilization of distal femoral fractures with the LISS: a prospective multicenter study. Result of a clinical study with special emphasis on difficult cases. Injury 2001; 32 Suppl 3: SC48-SC54.
    • (2001) Injury , vol.32 , Issue.SUPPL. 3
    • Schutz, M.1    Muller, M.2    Krettek, C.3    Regazzoni, P.4    Ganz, R.5    Haas, N.6
  • 18
    • 15944413426 scopus 로고    scopus 로고
    • Use of the Less Invasive Stabilization System (LISS) in patients with distal femoral (AO33) fractures: A prospective multicenter study
    • Schutz M, Muller M, Regazzoni P, Höntzsch D, Krettek C, Van der Werken C. Use of the Less Invasive Stabilization System (LISS) in patients with distal femoral (AO33) fractures: a prospective multicenter study. Arch Orthop Trauma Surg 2005; 125: 102-108.
    • (2005) Arch Orthop Trauma Surg , vol.125 , pp. 102-108
    • Schutz, M.1    Muller, M.2    Regazzoni, P.3    Höntzsch, D.4    Krettek, C.5    van der Werken, C.6
  • 19
    • 4644320492 scopus 로고    scopus 로고
    • Treatment of distal femur fractures using the Less Invasive Stabilization System: Surgical experience and early clinical results in 103 fractures
    • Kregor PJ, Stannard JA, Zlowodzki M, Cole PA. Treatment of distal femur fractures using the Less Invasive Stabilization System: Surgical experience and early clinical results in 103 fractures. J Orthop Trauma 2004; 18: 509-520.
    • (2004) J Orthop Trauma , vol.18 , pp. 509-520
    • Kregor, P.J.1    Stannard, J.A.2    Zlowodzki, M.3    Cole, P.A.4
  • 20
    • 0036227047 scopus 로고    scopus 로고
    • Fat embolism and related effects during reamed and unreamed intramedullary nailing in a pig model
    • Buttaro M, Mocetti E, Alfie V, Paniego G, Piñeiro L. Fat embolism and related effects during reamed and unreamed intramedullary nailing in a pig model. J Orthop Trauma 2002; 16: 239-244.
    • (2002) J Orthop Trauma , vol.16 , pp. 239-244
    • Buttaro, M.1    Mocetti, E.2    Alfie, V.3    Paniego, G.4    Piñeiro, L.5
  • 21
    • 0031109913 scopus 로고    scopus 로고
    • Fat embolism and death during prophylactic osteosynthesis of a metastatic femur using an unreamed femoral nail
    • Peter RE, Schopfer A, Le Coultre B, Hoffmeyer P. Fat embolism and death during prophylactic osteosynthesis of a metastatic femur using an unreamed femoral nail. J Orthop Trauma 1997; 11: 233-234.
    • (1997) J Orthop Trauma , vol.11 , pp. 233-234
    • Peter, R.E.1    Schopfer, A.2    le Coultre, B.3    Hoffmeyer, P.4
  • 22
    • 0034750251 scopus 로고    scopus 로고
    • Trochanteric fractures treated with a proximal femoral nail
    • Domingo LJ, Cecilia D, Herrera A, Resines C. Trochanteric fractures treated with a proximal femoral nail. Int Orthop 2001; 25: 298-301.
    • (2001) Int Orthop , vol.25 , pp. 298-301
    • Domingo, L.J.1    Cecilia, D.2    Herrera, A.3    Resines, C.4
  • 23
    • 17144467492 scopus 로고    scopus 로고
    • Reverse obliquity fractures of the intertrochanteric region of the femur
    • Haidukewych GJ, Israel A, Berry DJ. Reverse obliquity fractures of the intertrochanteric region of the femur. J Bone Joint Surg Am 2001; 83A: 643-650.
    • (2001) J Bone Joint Surg Am , vol.83 A , pp. 643-650
    • Haidukewych, G.J.1    Israel, A.2    Berry, D.J.3
  • 24
    • 14644423348 scopus 로고    scopus 로고
    • Potentially unstable intertrochanteric fractures
    • Im GI, Shin YW, Song YJ. Potentially unstable intertrochanteric fractures. J Orthop Trauma 2005; 19: 5-9.
    • (2005) J Orthop Trauma , vol.19 , pp. 5-9
    • Im, G.I.1    Shin, Y.W.2    Song, Y.J.3
  • 25
    • 44449121970 scopus 로고    scopus 로고
    • Proximal femoral nail for treatment of trochanteric femoral fractures
    • Morihara T, Arai Y, Tokugawa S. Proximal femoral nail for treatment of trochanteric femoral fractures. J Orthop Surg 2007; 15: 273-277.
    • (2007) J Orthop Surg , vol.15 , pp. 273-277
    • Morihara, T.1    Arai, Y.2    Tokugawa, S.3
  • 27
    • 0023229109 scopus 로고
    • Nonunions of intertrochanteric fractures of the femur following open reduction and internal fixation
    • Mariani EM, Rand JA. Nonunions of intertrochanteric fractures of the femur following open reduction and internal fixation. Clin Orthop Relat Res 1987; 218: 81-89.
    • (1987) Clin Orthop Relat Res , vol.218 , pp. 81-89
    • Mariani, E.M.1    Rand, J.A.2
  • 28
    • 54449097173 scopus 로고    scopus 로고
    • Is a sliding hip screw or IM nail the preferred implant for intertrochanteric fracture fixation?
    • Aros B, Tosteson ANA, Gottlieb DJ, Koval KJ. Is a sliding hip screw or IM nail the preferred implant for intertrochanteric fracture fixation? Clin Orthop 2008; 466: 2827-2832.
    • (2008) Clin Orthop , vol.466 , pp. 2827-2832
    • Aros, B.1    Tosteson, A.N.A.2    Gottlieb, D.J.3    Koval, K.J.4
  • 29
    • 4043050976 scopus 로고    scopus 로고
    • The lateral trochanteric wall. A key element in the reconstruction of unstable pertrochanteric hip fractures
    • Gotfried Y. The lateral trochanteric wall. A key element in the reconstruction of unstable pertrochanteric hip fractures. Clin Orthop 2004; 425: 82-86.
    • (2004) Clin Orthop , vol.425 , pp. 82-86
    • Gotfried, Y.1
  • 30
    • 33847656750 scopus 로고    scopus 로고
    • Integrity of the lateral femoral wall intertrochanteric hip fractures: An important predictor of a reoperation
    • Palm H, Jacobsen S, Sonne-Holm S, Gebuhr P. Integrity of the lateral femoral wall intertrochanteric hip fractures: An important predictor of a reoperation. J Bone Joint Surg Am 2007; 89-A: 470-475.
    • (2007) J Bone Joint Surg Am , vol.89 A , pp. 470-475
    • Palm, H.1    Jacobsen, S.2    Sonne-Holm, S.3    Gebuhr, P.4
  • 31
    • 2042421503 scopus 로고    scopus 로고
    • Comparison of a sliding hip screw with a trochanteric lateral support plate to an intramedullary hip screw for fixation of unstable intertrochanteric hip fractures: Cadaveric study
    • Bong MR, Patel V, Iesaka K, Egol KA, Kummer FJ, Koval KJ. Comparison of a sliding hip screw with a trochanteric lateral support plate to an intramedullary hip screw for fixation of unstable intertrochanteric hip fractures: cadaveric study. J Trauma 2004; 56: 791-794.
    • (2004) J Trauma , vol.56 , pp. 791-794
    • Bong, M.R.1    Patel, V.2    Iesaka, K.3    Egol, K.A.4    Kummer, F.J.5    Koval, K.J.6
  • 32
    • 0141522794 scopus 로고    scopus 로고
    • The effect of an attachable lateral support plate on the stability of intertrochanteric fracture fixation with a sliding hip screw
    • Su ET, DeWal H, Kummer FJ, Koval KJ. The effect of an attachable lateral support plate on the stability of intertrochanteric fracture fixation with a sliding hip screw. J Trauma 2003; 55: 504-508.
    • (2003) J Trauma , vol.55 , pp. 504-508
    • Su, E.T.1    de Wal, H.2    Kummer, F.J.3    Koval, K.J.4
  • 33
    • 0034267111 scopus 로고    scopus 로고
    • Effect of plate position relative to bending direction on the rigidity of a plate osteosynthesis. A theoretical analysis
    • Gautier E, Perren SM, Cordey J. Effect of plate position relative to bending direction on the rigidity of a plate osteosynthesis. A theoretical analysis. Injury 2000; 31 Suppl 3: C14-C20.
    • (2000) Injury , vol.31 , Issue.SUPPL. 3
    • Gautier, E.1    Perren, S.M.2    Cordey, J.3
  • 34
    • 0034777725 scopus 로고    scopus 로고
    • Biomechanical evaluation of the Less Invasive Stabilization System for the internal fixation of distal femur fractures
    • Marti A, Fankhauser C, Frenk A, Cordey J, Gasser B. Biomechanical evaluation of the Less Invasive Stabilization System for the internal fixation of distal femur fractures. J Orthop Trauma 2001; 15: 482-487.
    • (2001) J Orthop Trauma , vol.15 , pp. 482-487
    • Marti, A.1    Fankhauser, C.2    Frenk, A.3    Cordey, J.4    Gasser, B.5
  • 35
    • 1342347901 scopus 로고    scopus 로고
    • Minimal-invasive treatment of distal femoral fractures with the LISS (Less Invasive Stabilization System): A prospective study of 30 fractures with a follow up of 20 months
    • Fankhauser F, Gruber G, Schippinger G, Boldin C, Hofer HP, Grechenig W, et al. Minimal-invasive treatment of distal femoral fractures with the LISS (Less Invasive Stabilization System): A prospective study of 30 fractures with a follow up of 20 months. Acta Orthop Scand 2004; 75: 56-60.
    • (2004) Acta Orthop Scand , vol.75 , pp. 56-60
    • Fankhauser, F.1    Gruber, G.2    Schippinger, G.3    Boldin, C.4    Hofer, H.P.5    Grechenig, W.6
  • 36
    • 33748965764 scopus 로고    scopus 로고
    • The effect of plate rotation on the stiffness of femoral LISS: A mechanical study
    • Khalafi A, Curtiss S, Hazelwood S, Wolinsky P. The effect of plate rotation on the stiffness of femoral LISS: A mechanical study. J Orthop Trauma 2006; 20: 542-546.
    • (2006) J Orthop Trauma , vol.20 , pp. 542-546
    • Khalafi, A.1    Curtiss, S.2    Hazelwood, S.3    Wolinsky, P.4
  • 37
    • 4644229321 scopus 로고    scopus 로고
    • Early results of the Less Invasive Stabilization System for mechanically unstable fractures of the distal femur (AO/OTA Types A2, A3, C2, and C3)
    • Weight M, Collinge C. Early results of the Less Invasive Stabilization System for mechanically unstable fractures of the distal femur (AO/OTA Types A2, A3, C2, and C3). J Orthop Trauma 2004; 18: 503-508.
    • (2004) J Orthop Trauma , vol.18 , pp. 503-508
    • Weight, M.1    Collinge, C.2
  • 38
    • 17644415710 scopus 로고    scopus 로고
    • Treatment of distal femoral fractures in the elderly using a less-invasive plating technique
    • Wong MK, Leung F, Chow SP. Treatment of distal femoral fractures in the elderly using a less-invasive plating technique. Int Orthop 2005; 29: 117-120.
    • (2005) Int Orthop , vol.29 , pp. 117-120
    • Wong, M.K.1    Leung, F.2    Chow, S.P.3
  • 39
    • 0035749815 scopus 로고    scopus 로고
    • Distal femoral fractures and LISS stabilization
    • Schandelmaier P, Partenheimer A, Koenemann B. Distal femoral fractures and LISS stabilization. Injury 2001; 32 Suppl 3: SC55-SC63.
    • (2001) Injury , vol.32 , Issue.SUPPL. 3
    • Schandelmaier, P.1    Partenheimer, A.2    Koenemann, B.3
  • 40
    • 0037326752 scopus 로고    scopus 로고
    • The proximal femoral nail (PFN)-a minimal invasive treatment of unstable proximal femoral fractures: A prospective study of 55 patients with a follow-up of 15 months
    • Boldin C, Seibert FJ, Fankhauser F, Peicha G, Grechenig W, Szyszkowitz R. The proximal femoral nail (PFN)-a minimal invasive treatment of unstable proximal femoral fractures: a prospective study of 55 patients with a follow-up of 15 months. Acta Orthop Scand 2003; 74: 53-58.
    • (2003) Acta Orthop Scand , vol.74 , pp. 53-58
    • Boldin, C.1    Seibert, F.J.2    Fankhauser, F.3    Peicha, G.4    Grechenig, W.5    Szyszkowitz, R.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.