메뉴 건너뛰기




Volumn 31, Issue 19, 2011, Pages 122-128

Optimization design of detector for steel core broken strand faults in transmission line based on niche genetic algorithm

Author keywords

Broken strand; Magnetic flux leakage (MFL) detector; Niche genetic algorithm (NGA); Optimization design; Transmission line

Indexed keywords

ADAPTIVE ALGORITHMS; BANDPASS FILTERS; DESIGN; ELECTRIC LINES; GENETIC ALGORITHMS; INERTIAL CONFINEMENT FUSION; MAGNETIC LEAKAGE; MAGNETIC STRUCTURE; OPTIMIZATION; TRANSMISSION LINE THEORY;

EID: 79960567341     PISSN: 02588013     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (10)

References (28)
  • 1
  • 2
    • 78650616039 scopus 로고    scopus 로고
    • Chinese source. Beijing: Publishing House of Electronics Industry
    • Jiang Xingliang, Yi Hui. Icing and its defense for transmission line[M]. Beijing: Publishing House of Electronics Industry, 2002: 6-8(in Chinese).
    • (2002) Icing and Its Defense for Transmission Line , pp. 6-8
    • Jiang, X.1    Yi, H.2
  • 3
    • 78650616735 scopus 로고    scopus 로고
    • Chinese source. Beijing: Publishing House of Electronics Industry
    • Hu Yi. Analysis and defense for transmission line operation[M]. Beijing: Publishing House of Electronics Industry, 2007: 154-186(in Chinese).
    • (2007) Analysis and Defense for Transmission Line Operation , pp. 154-186
    • Hu, Y.1
  • 4
    • 34547151113 scopus 로고    scopus 로고
    • Fretting fatigue phenomena on an all aluminum alloy conductor
    • Boniardi M, Cincera S, D'Errico F, et al. Fretting fatigue phenomena on an all aluminum alloy conductor[J]. Key Engineering Materials, 2007, 348-349: 5-8.
    • (2007) Key Engineering Materials , vol.348-349 , pp. 5-8
    • Boniardi, M.1    Cincera, S.2    D'Errico, F.3
  • 5
    • 67649219313 scopus 로고    scopus 로고
    • Transmission line maintenance robots capable of crossing obstacles: stage-of-the-art review and challenges ahead
    • Toussaint K, Pouliot N, Montambault S. Transmission line maintenance robots capable of crossing obstacles: stage-of-the-art review and challenges ahead[J]. Journal of Field Robotics, 2009, 26(5): 477-499.
    • (2009) Journal of Field Robotics , vol.26 , Issue.5 , pp. 477-499
    • Toussaint, K.1    Pouliot, N.2    Montambault, S.3
  • 7
    • 33747438813 scopus 로고    scopus 로고
    • Development of a mobile inspection robot for high voltage power transmission line
    • Chinese source
    • Wu Gongping, Xiao Xiaohui, Xiao Hua, et al. Development of a mobile inspection robot for high voltage power transmission line[J]. Automation of Electric Power Systems, 2006, 30(13): 90-93, 107(in Chinese).
    • (2006) Automation of Electric Power Systems , vol.30 , Issue.13
    • Wu, G.1    Xiao, X.2    Xiao, H.3
  • 8
    • 51149083279 scopus 로고    scopus 로고
    • An on-line broken strand detection and diagnosis system for high-voltage transmission line inspection robots
    • Chinese source
    • Zhou Fengyu, Li Yibin, Li Feng, et al. An on-line broken strand detection and diagnosis system for high-voltage transmission line inspection robots[J]. Automation of Electric Power Systems, 2008, 32(14): 77-81, 107(in Chinese).
    • (2008) Automation of Electric Power Systems , vol.32 , Issue.14
    • Zhou, F.1    Li, Y.2    Li, F.3
  • 9
    • 33845757156 scopus 로고    scopus 로고
    • Damaged detection and fault diagnosis for high-voltage transmission line
    • Chinese source
    • Wu Gongping, Xiao Xiaohui, Shen Ruigang. Damaged detection and fault diagnosis for high-voltage transmission line[J]. Chinese Journal of Scientific Instrument, 2006, 27(10): 1204-1208(in Chinese).
    • (2006) Chinese Journal of Scientific Instrument , vol.27 , Issue.10 , pp. 1204-1208
    • Wu, G.1    Xiao, X.2    Shen, R.3
  • 10
    • 67349207135 scopus 로고    scopus 로고
    • Wave-based defect detection and inter-wire friction modeling for overhead transmission lines
    • Haag T, Beadle B M, Sprenger H, et al. Wave-based defect detection and inter-wire friction modeling for overhead transmission lines[J]. Archive of Applied Mechanics, 2009, 79(6): 517-528.
    • (2009) Archive of Applied Mechanics , vol.79 , Issue.6 , pp. 517-528
    • Haag, T.1    Beadle, B.M.2    Sprenger, H.3
  • 11
    • 79960606457 scopus 로고    scopus 로고
    • Inspection & assessment of overhead line conductors
    • Palo Alto, California, USA: EPRI
    • Lings R, Cannon D, Hill L, et al. Inspection & assessment of overhead line conductors[R]. Palo Alto, California, USA: EPRI, 2000.
    • (2000)
    • Lings, R.1    Cannon, D.2    Hill, L.3
  • 12
    • 61749096017 scopus 로고    scopus 로고
    • Study of inspection of wire breakage in aluminum transmission line using SQUID
    • Hatsukade Y, Miyazaki A, Matsuura H, et al. Study of inspection of wire breakage in aluminum transmission line using SQUID[J]. NDT&E International, 2009, 42(3), 170-173.
    • (2009) NDT&E International , vol.42 , Issue.3 , pp. 170-173
    • Hatsukade, Y.1    Miyazaki, A.2    Matsuura, H.3
  • 13
    • 68149116012 scopus 로고    scopus 로고
    • Detection of wire element breakage in power transmission line using HTS-SQUID
    • Miyazaki A, Hatsukade Y, Matsuura H, et al. Detection of wire element breakage in power transmission line using HTS-SQUID[J]. Physical C, 2009, 469(15-20): 1643-1648.
    • (2009) Physical C , vol.469 , Issue.15-20 , pp. 1643-1648
    • Miyazaki, A.1    Hatsukade, Y.2    Matsuura, H.3
  • 14
    • 77949899937 scopus 로고    scopus 로고
    • Conductor defect inspection of transmission line based on eddy current and magnetic flux leakage
    • Chinese source
    • Cai Chengliang, Ding Yigong, Kang Yihua, et al. Conductor defect inspection of transmission line based on eddy current and magnetic flux leakage[J]. Power System Technology, 2000, 24(11): 18-22(in Chinese).
    • (2000) Power System Technology , vol.24 , Issue.11 , pp. 18-22
    • Cai, C.1    Ding, Y.2    Kang, Y.3
  • 15
    • 53449098291 scopus 로고    scopus 로고
    • Use of eddy current technology to assist in the evaluation of the fatigue damage of electrical conductors
    • Dalpe C, Goudreau S, Cloutier L, et al. Use of eddy current technology to assist in the evaluation of the fatigue damage of electrical conductors[J]. Research in Nondestructive Evaluation, 2008, 19(4): 181-201.
    • (2008) Research in Nondestructive Evaluation , vol.19 , Issue.4 , pp. 181-201
    • Dalpe, C.1    Goudreau, S.2    Cloutier, L.3
  • 16
    • 0035471448 scopus 로고    scopus 로고
    • An application of solenoid sensor for inspecting deterioration of ACSR conductors due to forest fires
    • Kim S D, Morcos M M. An application of solenoid sensor for inspecting deterioration of ACSR conductors due to forest fires[J]. IEEE Power Engineering Review, 2001, 21(10): 50-53.
    • (2001) IEEE Power Engineering Review , vol.21 , Issue.10 , pp. 50-53
    • Kim, S.D.1    Morcos, M.M.2
  • 17
    • 33744749252 scopus 로고    scopus 로고
    • Geometrical optimization design of plate-fin heat exchanger using genetic algorithm
    • Chinese source
    • Xie Gongnan, Wang Qiuwang. Geometrical optimization design of plate-fin heat exchanger using genetic algorithm[J]. Proceedings of the CSEE, 2006, 26(7): 53-57(in Chinese).
    • (2006) Proceedings of the CSEE , vol.26 , Issue.7 , pp. 53-57
    • Xie, G.1    Wang, Q.2
  • 18
    • 16644371795 scopus 로고    scopus 로고
    • Application of modified genetic algorithm to the optimum design of traction transformer
    • Chinese source
    • Guo Hui. Application of modified genetic algorithm to the optimum design of traction transformer[J]. Proceedings of the CSEE, 2005, 25(4): 119-123(in Chinese).
    • (2005) Proceedings of the CSEE , vol.25 , Issue.4 , pp. 119-123
    • Guo, H.1
  • 19
    • 1642453917 scopus 로고    scopus 로고
    • Optimum design of dry-type air-core series reactor based on modified adaptive genetic algorith
    • Chinese source
    • Liu Zhigang, Geng Yingsan, Wang Jianhua, et al. Optimum design of dry-type air-core series reactor based on modified adaptive genetic algorithm[J]. Proceedings of the CSEE, 2003, 23(9): 103-106(in Chinese).
    • (2003) Proceedings of the CSEE , vol.23 , Issue.9 , pp. 103-106
    • Liu, Z.1    Geng, Y.2    Wang, J.3
  • 20
    • 33747426586 scopus 로고    scopus 로고
    • Optimal switching device placement based on niche genetic algorithm in distribution networks
    • Chinese source
    • Wang Yansong, Chen Guoming, Zhang Jiasheng, et al. Optimal switching device placement based on niche genetic algorithm in distribution networks[J]. Transactions of China Electrotechnical Society, 2006, 21(5): 82-86(in Chinese).
    • (2006) Transactions of China Electrotechnical Society , vol.21 , Issue.5 , pp. 82-86
    • Wang, Y.1    Chen, G.2    Zhang, J.3
  • 21
    • 2942709837 scopus 로고    scopus 로고
    • Niche genetic algorithm for optimization design of dynamic parameters of rigid multibody systems
    • Chinese source
    • Zhang Jingjun, Cui Wei, Wang Nan. Niche genetic algorithm for optimization design of dynamic parameters of rigid multibody systems[J]. Chinese Journal of Mechanical Engineering, 2004, 40(3): 66-70(in Chinese).
    • (2004) Chinese Journal of Mechanical Engineering , vol.40 , Issue.3 , pp. 66-70
    • Zhang, J.1    Cui, W.2    Wang, N.3
  • 24
    • 79960610372 scopus 로고    scopus 로고
    • Chinese source. American Society for Non-Destructive Testing. 2nd Edition. Shanghai: World Publishing Company
    • American Society for Non-Destructive Testing. Nondestructive testing handbook electromagnetic[M]. 2nd Edition. Shanghai: World Publishing Company, 1999: 922-977(in Chinese).
    • (1999) Nondestructive Testing Handbook Electromagnetic , pp. 922-977
  • 26
    • 70350471939 scopus 로고    scopus 로고
    • Chinese source. Beijing: China Electric Power Press
    • Wang Xiuhe. Permanent magnet motor[M]. Beijing: China Electric Power Press, 2008: 52-54(in Chinese).
    • (2008) Permanent Magnet Motor , pp. 52-54
    • Wang, X.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.